Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vicente Vanaclocha has a total of 126 co-authors. Here are the top co-authors by number of shared publications:

  • Nieves Saiz-Sapena

    Hospital General Universitario de Valencia, 46014 Valencia, Spain

    20 shared publications
  • Leyre Vanaclocha

    Medius Klinik, Ostfildern-Ruit Klinik, Hedelfinger Str. 166, 73760 Ostfildern, Germany

    18 shared publications
  • Leyre Vanaclocha

    Medius Klinik, Ostfildern-Ruit Klinik für Urologie, Hedelfinger Strasse 166, 73760 Ostfildern, Germany

    13 shared publications
  • Nieves Saiz-Sapena

    Department of Anesthesiology, General University Hospital of Valencia, Avda. de los Tres Cruces 2, 46014 Valencia, Spain

    10 shared publications
  • Juan Manuel Herrera

    A Department of Neurosurgery, Hospital General Universitario de Valencia , Valencia , Spain

    9 shared publications
  • José María Ortiz-Criado

    Instituto de Medicina Legal de Valencia (IMLV) and Department of Anatomy, Faculty of Medicine, Catholic University St. Vincent Martyr of Valencia, Valencia, Spain

    8 shared publications

Latest Publications

  • Clinical and radiological outcomes of ACDF using titanium-screw PEEK cages: A retrospective series

    by Francisco Verdú López, Vicente Vanaclocha, Alejandra Hernández-Valido, David Aliaga, José-María Gallego-Sánchez, Ana-María Morales-Codina

  • Shredded vs. pledget teflon in microvascular decompression for trigeminal neuralgia: a retrospective comparative study

    by V. Vanaclocha, J. M. Gallego-Sanchez, N. Saiz-Sapena, L. Vanaclocha

    Trigeminal neuralgia (TN) is a debilitating craniofacial pain disorder that often necessitates surgical intervention when medical therapy fails. This study evaluates the impact of two Teflon implantation techniques - pledget interposition and shredded Teflon - on clinical outcomes following microvascular decompression (MVD). A retrospective analysis was conducted on 121 patients with classical trigeminal neuralgia (TN) who underwent microvascular decompression (MVD) between 2001 and 2020. Patients were grouped based on the Teflon technique used: pledget interposition (n = 55) or shredded Teflon (n = 66). Outcomes were assessed using the Barrow Neurological Institute (BNI) pain scale, Modified Rankin Scale (mRS), and postoperative MRI. Statistical comparisons included Fisher's exact test, chi-square test, and t-tests. Shredded Teflon was associated with significantly lower recurrence (4.54% vs. 16.36%) and complication rates (9.09% vs. 14.55%) compared to pledget interposition. Reoperation was required in 12.72% of pledget cases, primarily due to implant displacement and arachnoid adhesions; no reoperations were needed in the shredded group. MRI-confirmed recurrent neurovascular compression correlated with clinical recurrence (p = 0.033). Patient satisfaction was significantly higher in the shredded group (87.87% vs. 69.09%, p = 0.001). MVD using shredded Teflon yields superior long-term outcomes with fewer complications and recurrences compared to pledget interposition. Avoiding direct nerve contact and minimizing implant volume may reduce inflammatory risks. Postoperative MRI is crucial for detecting recurrence and guiding subsequent interventions.


  • Open Access

    Long-term outcomes of total lumbar disc prosthesis: Sustained pain relief

    by Vicente Vanaclocha, Pablo Jordá-Gómez, Nieves Saiz-Sapena, Juan Martínez-Leon, Leyre Vanaclocha


  • Reducing facet joint overload with a Kevlar-augmented lumbar disc replacement: An ex vivo investigation

    by V. Vanaclocha, C. Atienza, A. Vanaclocha, P. Jorda-Gomez, A. Peñuelas, E. Medina-Ripoll, A. Gómez-Pérez, N. Saiz-Sapena, L. Vanaclocha

  • Facet joint loading after Kevlar-reinforced disc replacement vs. lumbar fusion. A cadaveric model study

    by Amparo Vanaclocha, Vicente Vanaclocha, Carlos Atienza, Pablo Jorda-Gomez, Andres Peñuelas, David Gomez-Lopez

  • Open Access

    Effect of Ti6Al4V Alloy Surface and Porosity on Bone Osseointegration: In Vivo Pilot Study in Rabbits

    by Amparo Vanaclocha, Vicente Vanaclocha, Carlos M. Atienza, Pablo Jordá-Gómez, Víctor Primo-Capella, Jose R. Blasco, Luis Portolés, Nieves Saiz-Sapena, Leyre Vanaclocha

    Unmodified Ti6Al4V can osseointegrate, but sometimes this capacity needs to be improved. This study aimed to see how much porosity improves osseointegration in a Ti6Al4V implant. Three types of Ti6Al4V cylindrical-shaped implants (13.00 mm length × 5.00 mm diameter) were evaluated: solid sandblasted acid-etched, sintered, and porous 3D-printed (681.00 µm average pore size). Fifteen 20-week-old nullipara female parasite-free New Zealand California white rabbits were used, employing the femoral condyle defect model and undertaking µ-CT analysis and pull-out testing eight weeks later. On µ-CT densitometric analysis, the solid sandblasted rod showed the highest new bone growth around the implant. Bone growth was higher inside the implants for the porous 3D-printed (54.00 ± 5.00 mm3) than for the sintered (1.00 ± 0.05 mm3) and zero for the sandblasted implants. In the pull-out test, there were no statistically significant differences in the ANOVA analysis between the sintered (900.00 N ± 310.00 N) and porous 3D-printed (700.00 N ± 220.00 N) implants. Such differences did exist between the sandblasted material (220.00 N ± 50.00 N) and the two other materials (sintered p 0.002, porous p 0.034). The porous 3D-printed and sintered implant pull-out strength were significantly better than that of the solid rod sandblasted implant. Still, there were no statistically significant differences between the first two.


  • Open Access

    Dental Implant with Porous Structure and Anchorage: Design and Bench Testing in a Calf Rib Model Study

    by Keila Lovera, Vicente Vanaclocha, Carlos M. Atienza, Amparo Vanaclocha, Pablo Jordá-Gómez, Nieves Saiz-Sapena, Leyre Vanaclocha

    Primary dental implant stability is critical to enable osseointegration. We assessed the primary stability of our newly designed dental implant. We used the calf rib bone animal model. Our implant has an outside tapered screw with two inside barrettes that deploy with a second screw situated at the implant’s crown. We used ten calf ribs with III/IV bone density and inserted ten implants per rib. We deployed the barrettes in the calf rib’s transversal direction to support against the nearby cortical bone. We measured the primary implant’s stability with resonance frequency analysis and collected the Implant Stability Quota (ISQ) in the transverse and longitudinal calf rib planes before (PRE) and after (POS) deploying the barrette. The mean ISQ was PRE 84.00 ± 3.56 and POS 84.73 ± 4.53 (p = 0.84) in the longitudinal plane and PRE 81.80 ± 2.74 and POS 83.53 ± 4.53 (0.27) in the transverse plane. The barrettes’ insertion increases our dental implant primary stability by 11% in the transverse plane and 2% in the longitudinal plane. Our dental implant ISQ values are in the higher range than those reported in the literature and reflect high primary stability after insertion. The barrette deployment improves the dental implant’s primary stability, particularly in the direction in which it deploys (transverse plane).


  • Open Access

    New Subperiosteal Dental Implant Design with Finite Element Analysis and Mechanical Validation: A Design Validation Study

    by Vicente Vanaclocha, Carlos Atienza, Amparo Vanaclocha, Andrés Peñuelas, Juan Gómez-Herrero, Francisco Pérez-Carrió, José Antonio Diego-Leyda, Nieves Sáiz-Sapena, Leyre Vanaclocha

    New subperiosteal dental implants were designed to offer new options to edentulous patients with severe bone resorption for whom endosseous dental implants are not advisable. In our study, we aimed to design and manufacture subperiosteal dental implants with a minimum volume to facilitate surgical maneuvers and metal coverage by mucosa while ensuring maximal long-term implant strength and functionality. With cone-beam CT-scan data obtained from an edentulous patient, a maxilla and mandible recreation were created, and subperiosteal implants were designed and analyzed with FEA (250 MPa infinite-life limit stress). We redesigned them until they stood the infinite-life limit loads mentioned above. Then, they were manufactured with Ti6Al4V alloy and laser-powder bed fusion technology. All implants withstood mechanical tests (450 N static and 150 N loads for five-million cycle 150 N fatigue tests) with no failures. The first design resulted in maxillary and mandibular implant failures. Through the redesign process, the implant volume was reduced, and the number and placement of bone fixation screws were optimized while maintaining resistance to chewing. Once manufactured, these new implants withstood the loads mentioned above without failure. Our subperiosteal dental implants are an option for edentulous patients with severe maxilla and mandibular bone resorption. Manufactured with Ti6Al4V alloy and laser-powder bed fusion technology, they withstood the above-mentioned mechanical tests without failure.


  • Open Access

    Can a single basal cistern urokinase bolus help to prevent subarachnoid hemorrhage consequences?

    by Vicente Vanaclocha, Juan-Manuel Herrera, Marlon Rivera-Paz, Nieves Saiz-Sapena, Leyre Vanaclocha


  • Open Access

    Prevertebral Anchored Kevlar Band to Recover Intact Spine Movement Ranges in Lumbar Disc Arthroplasty

    by Amparo Vanaclocha, Vicente Vanaclocha, Carlos M. Atienza, Pablo Jordá-Gómez, Andres Peñuelas, Nieves Saiz-Sapena, Leyre Vanaclocha

    Anterior longitudinal ligament and annulus fibrosus removal in total disc replacement induces excessive spinal mobility with zygapophyseal joint overload and osteoarthritic changes causing chronic back pain. To control disc arthroplasty-induced hypermobility with a Kevlar® band. A 3 × 3 cm Kevlar® band implanted in twelve human lumbar cadaveric spines substituted the anterior longitudinal ligament and annulus in disc arthroplasty. Biomechanical studies compared the intact spine, after discectomy, post-disc arthroplasty, and with the Kevlar® band inserted. The Kevlar® band recovered the extension and axial rotation movement ranges without regaining the intact status. Improvement was moderate in lateral bending. The Instantaneous Axis of Rotation improved the discectomy and total disc prosthesis conditions without recovering the initial state. The disc above the operated one also showed increased mobility, particularly in extension and axial rotation, improved by Kevlar® band insertion without recovering the intact spine values. The Kevlar® band improves excess mobility ranges induced by anterior longitudinal ligament and anterior annulus removal in disc arthroplasty in the operated and supra-adjacent discs without recovering the baseline status.