MBMark Henrik Bonnichsen

Mark Henrik Bonnichsen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mark Henrik Bonnichsen has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Endoscopic ultrasound-directed transgastric ERCP for disconnected pancreatic duct syndrome: finding the edge to bridge the gap

    by Mark Henrik Bonnichsen, Prima Bianca Gaffud Chua, Clement Chun-Ho Wu, Ravishankar Asokkumar, Christopher J. Khor, Damien M.Y. Tan

    Altered anatomy from Roux-en-Y gastric bypass makes access to the papilla difficult. Solutions such as balloon-assisted and laparoscopy-assisted endoscopic retrograde cholangiopancreatography (ERCP) are complicated by sub-optimal technical success and adverse event rates [1]. EUS-directed transgastric ERCP (EDGE) is a promising solution with high technical and clinical success rates [2] and provides ease of access if multiple procedures are required. A 60-year-old woman with a previous Roux-en-Y gastric bypass for obesity 8 years before admission presented with severe necrotizing acute pancreatitis. She developed infected pancreatic fluid collections and septic shock secondary to disconnected pancreatic duct syndrome. She underwent multiple percutaneous drainages and laparotomies with washouts over a period of 3 months. She was deemed unsuitable for a distal pancreatectomy. Given the Roux-en-Y anatomy, she was offered EDGE to bridge the disconnected duct. A linear echoendoscope (EG38-J10UT; Pentax Medical, Tokyo, Japan) was advanced to the Roux anastomosis ([Video 1]). Assessment at the 49-cm mark from the incisors in the remnant stomach pouch showed a collapsed structure and 19G needle was used to distend this structure to reveal the excluded stomach on fluoroscopy. Direct puncture was performed into the excluded stomach, and a gastro-gastric anastomosis was created using a 20×10-mm lumen-apposing stent system (Axios; Boston Scientific, Marlborough, Massachusetts, USA). We dilated the stent further using a 20-mm balloon dilator. To facilitate successful ERCP and prevent stent migration during the procedure, we sutured the proximal stent to the bowel wall at two sites using the OverStitch device (Apollo Endosurgery, Austin, Texas, USA). We advanced a duodenoscope (ED34-i10T2; Pentax Medical) through the stent, and the pancreatogram showed partial disruption of the duct at the tail of the pancreas leading into a collection ([Fig. 1] a). We performed a pancreatic sphincterotomy, and our attempts to pass a wire across the disconnected duct were unsuccessful ([Fig. 1] b). We then deployed a 5Fr×12-cm single-pigtail pancreatic stent with its tip located within the collection. A follow-up pancreatogram at 6 weeks showed healing of the disconnected duct, allowing passage of a guidewire ([Fig. 1] c). We deployed a 5Fr×15-cm single-pigtail stent across the disconnected duct. Further imaging showed resolution of the collection and improvement in patient status. The pancreatic stent was removed 22 weeks later, and it showed no further leak ([Fig. 1] d). A progress computed tomography scan shows resolution of the collection. To our knowledge this is the first case of EDGE for disconnected pancreatic duct syndrome. This syndrome occurs in about 50% of patients with acute necrotizing pancreatitis, and pancreatic stenting has been utilized to bridge the disrupted duct to the viable pancreas upstream [3]. Given the complex clinical presentation, ease of access for multiple procedures and stent insertion permitted healing of the disconnected duct. A particular adverse event of EDGE has been demonstrated to be stent migration [4]. This has been addressed by utilization of a larger lumen-apposing metal stent (LAMS), i.e., 20-mm stent and fixation with endoscopic sutures, which we utilized in this patient. In contrast to established techniques, EDGE provided a solution to a complex clinical problem that required multiple interventions to achieve clinical resolution. Endoscopy_UCTN_Code_TTT_1AS_2AD Article published online: 23 April 2024 © 2024. The Author(s). This article was originally published by Thieme in Endoscopy 2024; 56: E41–E42 as an open access article under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Biodegradable stent causing pancreatitis after papillectomy

    by Mark Henrik Bonnichsen, Prima Bianca Chua, Christopher Khor, Damien M.Y. Tan


  • Open Access

    Endoscopic ultrasound-directed transgastric ERCP for disconnected pancreatic duct syndrome: finding the edge to bridge the gap

    by Mark Henrik Bonnichsen, Prima Bianca Gaffud Chua, Clement Chun-Ho Wu, Ravishankar Asokkumar, Christopher J. Khor, Damien M.Y. Tan

    Altered anatomy from Roux-en-Y gastric bypass makes access to the papilla difficult. Solutions such as balloon-assisted and laparoscopy-assisted endoscopic retrograde cholangiopancreatography (ERCP) are complicated by sub-optimal technical success and adverse event rates [1]. EUS-directed transgastric ERCP (EDGE) is a promising solution with high technical and clinical success rates [2] and provides ease of access if multiple procedures are required. A 60-year-old woman with a previous Roux-en-Y gastric bypass for obesity 8 years before admission presented with severe necrotizing acute pancreatitis. She developed infected pancreatic fluid collections and septic shock secondary to disconnected pancreatic duct syndrome. She underwent multiple percutaneous drainages and laparotomies with washouts over a period of 3 months. She was deemed unsuitable for a distal pancreatectomy. Given the Roux-en-Y anatomy, she was offered EDGE to bridge the disconnected duct. A linear echoendoscope (EG38-J10UT; Pentax Medical, Tokyo, Japan) was advanced to the Roux anastomosis ([Video 1]). Assessment at the 49-cm mark from the incisors in the remnant stomach pouch showed a collapsed structure and 19G needle was used to distend this structure to reveal the excluded stomach on fluoroscopy. Direct puncture was performed into the excluded stomach, and a gastro-gastric anastomosis was created using a 20×10-mm lumen-apposing stent system (Axios; Boston Scientific, Marlborough, Massachusetts, USA). We dilated the stent further using a 20-mm balloon dilator. To facilitate successful ERCP and prevent stent migration during the procedure, we sutured the proximal stent to the bowel wall at two sites using the OverStitch device (Apollo Endosurgery, Austin, Texas, USA). We advanced a duodenoscope (ED34-i10T2; Pentax Medical) through the stent, and the pancreatogram showed partial disruption of the duct at the tail of the pancreas leading into a collection ([Fig. 1] a). We performed a pancreatic sphincterotomy, and our attempts to pass a wire across the disconnected duct were unsuccessful ([Fig. 1] b). We then deployed a 5Fr×12-cm single-pigtail pancreatic stent with its tip located within the collection. A follow-up pancreatogram at 6 weeks showed healing of the disconnected duct, allowing passage of a guidewire ([Fig. 1] c). We deployed a 5Fr×15-cm single-pigtail stent across the disconnected duct. Further imaging showed resolution of the collection and improvement in patient status. The pancreatic stent was removed 22 weeks later, and it showed no further leak ([Fig. 1] d). A progress computed tomography scan shows resolution of the collection. To our knowledge this is the first case of EDGE for disconnected pancreatic duct syndrome. This syndrome occurs in about 50% of patients with acute necrotizing pancreatitis, and pancreatic stenting has been utilized to bridge the disrupted duct to the viable pancreas upstream [3]. Given the complex clinical presentation, ease of access for multiple procedures and stent insertion permitted healing of the disconnected duct. A particular adverse event of EDGE has been demonstrated to be stent migration [4]. This has been addressed by utilization of a larger lumen-apposing metal stent (LAMS), i.e., 20-mm stent and fixation with endoscopic sutures, which we utilized in this patient. In contrast to established techniques, EDGE provided a solution to a complex clinical problem that required multiple interventions to achieve clinical resolution. Endoscopy_UCTN_Code_TTT_1AS_2AD Article published online: 09 January 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    Clip-and-line traction method for difficult ERCP cannulation due to choledochocoele

    by Mark Henrik Bonnichsen, Angela Djajakusuma, Clement C.H. Wu, Christopher J.L. Khor, Damien M.Y. Tan


  • Open Access

    Endoscopic Management of Bouveret Syndrome With Electrohydraulic Lithotripsy

    by Hunter Wang, Conner Blackmore, Mark Bonnichsen, George Ermerak, Milan Bassan


  • Open Access

    Metal stenting for caustic esophageal injury with bronchoesophageal fistula

    by Mark H. Bonnichsen, Jack McNamara, Goktug Ermerak, Yasser Farooque, Milan Bassan

    A 68-year-old woman presented after intentional ingestion of a pH 11 caustic solution (sodium hypochlorite and sodium hydroxide). Urgent gastroscopy showed severe distal esophageal stricturing with Zargar IIA injury [1] that could not be traversed with a standard gastroscope ([Fig. 1]). A computed tomography (CT) scan did not show evidence of esophageal perforation. She required a long period in intensive care complicated by deconditioning and pneumonia. Repeat gastroscopy showed fibrotic stricturing with a 4-mm lumen. Sequential dilatation was performed to 6–8 mm with a dilating balloon over guidewire under fluoroscopic control. A small locule of extraluminal gas was noted on a CT to investigate post-procedure pain. This was managed nonoperatively. The clinical course was complicated by difficulty managing oral secretions. A progress gastroscopy 2 months later showed persistent stricturing with pus seen in the lumen ([Video 1]). Acute hypercapnia was noted on capnography. Intraprocedural contrast injection demonstrated a bronchoesophageal fistula into the left main bronchus ([Fig. 2]). Video 1 Metal stenting for caustic esophageal injury with bronchoesophageal fistula. A multidisciplinary team meeting decision was made for delayed esophagectomy once sepsis and nutritional status were optimized. To attempt to seal the fistula as a bridge to surgery and given the severity of the stricture, a decision was made to place a 10-mm × 80-mm partially covered biliary stent (WallFlex, Boston Scientific, Massachusetts, USA) as the narrow lumen would reduce the risk of perforation or airway compression on stent expansion and the partially covered ends would reduce the risk of migration and leakage around the stent flanges. This was deployed under endoscopic and fluoroscopic guidance. Contrast injection confirmed no further contrast leakage into the bronchus. Following stent placement there was improvement in respiratory sepsis. Owing to the ongoing inability to swallow secretions, a second partially covered biliary stent (10 mm × 60 mm) was placed distally to cross the gastroesophageal junction ([Fig. 3]). After insertion of the second self-expanding metal stent (SEMS), there was clinical improvement to the point where the surgical risk was deemed acceptable. However, the patient declined esophagectomy. At the 6-month follow-up, the patient’s clinical condition was stable. Intentional caustic injuries are increasing in adults [2]. Bronchoesophageal fistulae are a recognized but rare complication [3] [4]. Fully and partially covered SEMSs have been utilized for post-operative leaks and fistulae in the upper gastrointestinal tract [5], but the use of a partially covered biliary SEMS to manage a bronchoesophageal fistula after caustic injury has not been previously described. Esophagectomy, especially in the setting of a bronchoesophageal fistula, is a high-risk surgical intervention. Optimization of patient factors such as sepsis and malnutrition are critical to achieve a good outcome. In this case of a high grade esophageal stricture and bronchoesophageal fistula, the use of two partially covered biliary SEMSs to improve esophageal patency and seal the fistula proved effective in allowing the patient’s condition to improve sufficiently to allow definitive surgery. A narrow-caliber stent was used due to concerns of potential esophageal perforation or airway compression on stent expansion owing to severe esophageal stenosis and airway involvement. A narrow-caliber SEMS may be useful to manage esophageal strictures with fistulae, at least as a bridge to operative management in the setting of complex esophageal caustic injuries, and their use should be considered in these difficult clinical situations. Endoscopy_UCTN_Code_TTT_1AO_2AZ Article published online: 10 October 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    Outcomes of patients with hepaticojejunostomy anastomotic strictures undergoing endoscopic and percutaneous treatment

    by Kevin Kyung Ho Choi, Mark Henrik Bonnichsen, Ken Liu, Saniya Massey, Dominic Andre Staudenmann, Payal Saxena, Arthur John Kaffes

    Background and study aims The increase in hepaticojejunostomies has led to an increase in benign strictures of the anastomosis. Double balloon enteroscopy-assisted ERCP (DBE-ERCP) and percutaneous transhepatic biliary drainage (PTBD) are treatment options; however, there is lack of long-term outcomes, with no consensus on management. We performed a retrospective study assessing the outcomes of patients referred for endoscopic management of hepaticojejunostomy anastomotic strictures (HJAS).Patients and methods All consecutive patients at a tertiary institution underwent endoscopic intervention for suspected HJAS between 2009 and 2021 were enrolled.Results Eighty-two subjects underwent DBE-ERCP for suspected HJAS. The technical success rate was 77 % (63/82). HJAS was confirmed in 41 patients. The clinical success rate for DBE-ERCP ± PTBD was 71 % (29/41). DBE-ERCP alone achieved clinical success in 49 % of patients (20/41). PTBD was required in 49 % (20/41). Dual therapy was required in 22 % (9/41). Those with liver transplant had less technical success compared to other surgeries (72.1 % vs 82.1 % P = 0.29), less clinical success with DBE-ERCP alone (40 % vs 62.5 % P = 0.16) and required more PTBD (56 % vs 37.5 % P = 0.25). All those with ischemic biliopathy (n = 9) required PTBD for clinical success, required more DBE-ERCP (4.4 vs 2.0, P = 0.004), more PTBD (4.7 vs 0.3, P < 0.0001), longer treatment duration (181.6 vs 99.5 days P = 0.12), and had higher rates of recurrence (55.6 % vs 30.3 % P = 0.18) compared to those with HJAS alone. Liver transplant was the leading cause of ischemic biliopathy (89 %). The overall adverse event rate was 7 %.Conclusions DBE-ERCP is an effective diagnostic and therapeutic tool in those with altered gastrointestinal anatomy and is associated with low complication rates.


  • Pill related oesophagitis due to tenofovir disproxil fumarate/emtricitabine (Truvada) HIV pre‐exposure prophylaxis

    by Mark H. Bonnichsen, Mark Tschuchnigg, Jeffrey J. Post, William Bye


  • Safety first, a harmful interaction between rivaroxaban and berberine

    by Mark Bonnichsen, Ted Stoklosa, David Bowen, Avik Majumdar