Guangyao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Guangyao Wang has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Jianping Sun
National Institute of Metrology, Beijing, China
12 shared publications - Ting Li
National Institute of Metrology (NIM), Beijing 100029, People’s Republic of China
8 shared publications Ting Li
National Institute of Metrology, Beijing, China
6 shared publications- Songkui Chen
National Institute of Metrology, Beijing, China
4 shared publications Weiwei Feng
Division of Thermophysics Metrology, National Institute of Metrology, Beijing, China
4 shared publications- Weiwei Feng
Division of Thermophysics Metrology, National Institute of Metrology, People’s Republic of China
4 shared publications
Latest Publications
- 20 October 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- p. 1-16
Rapid reproduction of miniature Ga–Sn alloy fixed points for shipborne thermometer calibration
- 20 October 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- p. 1-16
Rapid reproduction of miniature Ga–Sn alloy fixed points for shipborne thermometer calibration
- Open Access
- 15 September 2026
- Published by Elsevier in SSRN Electronic Journal
New calibration method of NTC thermistors using a pre-established population model via two-point
This study proposes a material-constant β-correction method that uses only two temperature points by establishing a functional relationship between β and the logarithm of resistance. 70 NTC thermistors were calibrated throughout the range of 268.15 K to 308.15 K, with the triple point of water (273.16 K) and the gallium melting point (302.9146 K) as the calibration points. Compared with the Basic equation, the proposed method reduced the average absolute residual from 69.1 mK to 3.6 mK over 273.15 K to 303.15 K. At the extrapolated temperatures of 5 K beyond the calibration range, the average residual decreased from 69.9 mK to 3.8 mK. Generalisation was assessed through random training-test splits and additional validation on thermistors of different types, with a separate population model established for each type. The mean absolute residuals remained below 6.2 mK at interpolated temperatures and below 11.1 mK at extrapolated temperatures. The proposed calibration method with a pre-established population model enables high-precision calibration of NTC thermistors over a 40 K temperature range using only two calibration points.
- 15 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNew calibration method of NTC thermistors using a pre-established population model via two-point
This study proposes a material-constant β-correction method that uses only two temperature points by establishing a functional relationship between β and the logarithm of resistance. 70 NTC thermistors were calibrated throughout the range of 268.15 K to 308.15 K, with the triple point of water (273.16 K) and the gallium melting point (302.9146 K) as the calibration points. Compared with the Basic equation, the proposed method reduced the average absolute residual from 69.1 mK to 3.6 mK over 273.15 K to 303.15 K. At the extrapolated temperatures of 5 K beyond the calibration range, the average residual decreased from 69.9 mK to 3.8 mK. Generalisation was assessed through random training-test splits and additional validation on thermistors of different types, with a separate population model established for each type. The mean absolute residuals remained below 6.2 mK at interpolated temperatures and below 11.1 mK at extrapolated temperatures. The proposed calibration method with a pre-established population model enables high-precision calibration of NTC thermistors over a 40 K temperature range using only two calibration points.
- 1 September 2026
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 55 (3)
Pressure Dependence of Melting Temperatures for Ga–In, Ga–Sn, and Ga–Zn Eutectic Fixed Points
This study systematically investigates the pressure dependence of the melting points of three gallium-based eutectic alloys—Ga–In, Ga–Sn, and Ga–Zn—as potential secondary temperature standards. Open-type fixed-point cells were used in conjunction with a precision temperature–pressure control system, and five independent realization cycles were performed for each alloy to ensure high reproducibility. The system exhibits exceptional stability, maintaining melting plateaus for ∼100 h with a drift of less than 0.5 mK over 25 h. The experimental results demonstrate a strictly linear negative correlation between melting temperature and applied pressure for all three alloys. The measured pressure coefficients dT/dp are −0.93 × 10−8 K Pa−1 for Ga–In, −1.15 × 10−8 K Pa−1 for Ga–Sn, and −1.38 × 10−8 K Pa−1 for Ga–Zn. The experimental standard deviations of the means for these three coefficients are all below 0.05 × 10−8 K Pa−1, confirming the high precision and statistical reliability of the determined values. These coefficients are in excellent agreement with thermodynamic (CALPHAD) calculations (deviations below 10%). Characteristic melting temperatures were determined using the tangent intersection method: 15.647 72 °C for Ga–In and 25.199 99 °C for Ga–Zn (the melting temperature of Ga–Sn is 20.481 79 °C), with combined expanded uncertainties (k = 2) of 0.37 and 0.49 mK, respectively. This work establishes a robust theoretical and experimental foundation for understanding pressure-induced phase behavior in multi-component liquid metals, providing critical thermodynamic insights for deploying Ga-based phase-change materials as highly stable thermal references in extreme or non-standard engineering environments.
- 1 September 2026
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 55 (3)
Pressure Dependence of Melting Temperatures for Ga–In, Ga–Sn, and Ga–Zn Eutectic Fixed Points
This study systematically investigates the pressure dependence of the melting points of three gallium-based eutectic alloys—Ga–In, Ga–Sn, and Ga–Zn—as potential secondary temperature standards. Open-type fixed-point cells were used in conjunction with a precision temperature–pressure control system, and five independent realization cycles were performed for each alloy to ensure high reproducibility. The system exhibits exceptional stability, maintaining melting plateaus for ∼100 h with a drift of less than 0.5 mK over 25 h. The experimental results demonstrate a strictly linear negative correlation between melting temperature and applied pressure for all three alloys. The measured pressure coefficients dT/dp are −0.93 × 10−8 K Pa−1 for Ga–In, −1.15 × 10−8 K Pa−1 for Ga–Sn, and −1.38 × 10−8 K Pa−1 for Ga–Zn. The experimental standard deviations of the means for these three coefficients are all below 0.05 × 10−8 K Pa−1, confirming the high precision and statistical reliability of the determined values. These coefficients are in excellent agreement with thermodynamic (CALPHAD) calculations (deviations below 10%). Characteristic melting temperatures were determined using the tangent intersection method: 15.647 72 °C for Ga–In and 25.199 99 °C for Ga–Zn (the melting temperature of Ga–Sn is 20.481 79 °C), with combined expanded uncertainties (k = 2) of 0.37 and 0.49 mK, respectively. This work establishes a robust theoretical and experimental foundation for understanding pressure-induced phase behavior in multi-component liquid metals, providing critical thermodynamic insights for deploying Ga-based phase-change materials as highly stable thermal references in extreme or non-standard engineering environments.
- 8 April 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (9)
High Sensitivity Wireless Passive Temperature Sensor Based on Butterfly-shaped Slot Sandwich SIW Resonator
This paper presents a novel high-sensitivity wireless passive temperature sensor featuring an innovative butterfly-shaped slot coupled with a sandwich substrate-integrated waveguide (SIW) structure. The compact 36 mm × 36 mm × 1 mm device employs the butterfly slot for efficient electromagnetic wave coupling into the SIW resonant cavity, where resonance frequency shifts are governed by temperature-dependent variations in the substrate's equivalent permittivity. By embedding a CaTiO₃ ceramic plate within the SIW structure, we achieve significantly enhanced temperature sensitivity. Measurement results show a consistent linear frequency increase from 4.785 GHz at 25°C to 4.978 GHz at 125°C, corresponding to an exceptional sensitivity of 1.993 MHz/°C. The proposed design combines the advantages of compact size, low manufacturing cost, and outstanding sensitivity, positioning it as an excellent candidate for precision temperature monitoring in demanding applications.
- 8 April 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (9)
High Sensitivity Wireless Passive Temperature Sensor Based on Butterfly-shaped Slot Sandwich SIW Resonator
This paper presents a novel high-sensitivity wireless passive temperature sensor featuring an innovative butterfly-shaped slot coupled with a sandwich substrate-integrated waveguide (SIW) structure. The compact 36 mm × 36 mm × 1 mm device employs the butterfly slot for efficient electromagnetic wave coupling into the SIW resonant cavity, where resonance frequency shifts are governed by temperature-dependent variations in the substrate's equivalent permittivity. By embedding a CaTiO₃ ceramic plate within the SIW structure, we achieve significantly enhanced temperature sensitivity. Measurement results show a consistent linear frequency increase from 4.785 GHz at 25°C to 4.978 GHz at 125°C, corresponding to an exceptional sensitivity of 1.993 MHz/°C. The proposed design combines the advantages of compact size, low manufacturing cost, and outstanding sensitivity, positioning it as an excellent candidate for precision temperature monitoring in demanding applications.
- 13 March 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (10) , 105003
Dual-parameter high-precision thermometry based on Ca₃Al₄ZnO 10 : Eu 3+ phosphor
To address the demand for high-precision monitoring of dynamic temperature fields, Eu 3+ -doped Ca₃Al₄ZnO 10 phosphors were synthesized via a high-temperature solid-state reaction. The material exhibits a phosphorescence lifetime of approximately 1.6 ms at 22 °C, demonstrating favorable rapid-response characteristics. The temperature-dependent luminescence behavior under 300 Hz modulated excitation was systematically investigated. By simultaneously acquiring two parameters—phosphorescence lifetime and the time-domain peak-to-valley ratio—a dual-parameter joint temperature calibration model was established. Experimental results indicate that the proposed joint method effectively leverages the complementary nature of the two parameters, significantly enhancing measurement accuracy and robustness through mutual cross-verification and error suppression. Evaluations at three characteristic temperatures (3 °C, 55 °C, and 97 °C) within the 0 °C–100 °C calibration range consistently demonstrated the superior performance of the dual-parameter method, achieving a minimum mean absolute error of 0.11 °C at 97 °C. This study provides a reliable and adaptable solution for high-precision phosphor thermometry, showing promising potential for applications in thermal management of electronic devices.
- 13 March 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (10) , 105003
Dual-parameter high-precision thermometry based on Ca₃Al₄ZnO 10 : Eu 3+ phosphor
To address the demand for high-precision monitoring of dynamic temperature fields, Eu 3+ -doped Ca₃Al₄ZnO 10 phosphors were synthesized via a high-temperature solid-state reaction. The material exhibits a phosphorescence lifetime of approximately 1.6 ms at 22 °C, demonstrating favorable rapid-response characteristics. The temperature-dependent luminescence behavior under 300 Hz modulated excitation was systematically investigated. By simultaneously acquiring two parameters—phosphorescence lifetime and the time-domain peak-to-valley ratio—a dual-parameter joint temperature calibration model was established. Experimental results indicate that the proposed joint method effectively leverages the complementary nature of the two parameters, significantly enhancing measurement accuracy and robustness through mutual cross-verification and error suppression. Evaluations at three characteristic temperatures (3 °C, 55 °C, and 97 °C) within the 0 °C–100 °C calibration range consistently demonstrated the superior performance of the dual-parameter method, achieving a minimum mean absolute error of 0.11 °C at 97 °C. This study provides a reliable and adaptable solution for high-precision phosphor thermometry, showing promising potential for applications in thermal management of electronic devices.
- 22 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 105115
Novel high-resolution wireless temperature sensor based on sandwich complementary split-ring resonator substrate-integrated waveguide structure
This paper presents a novel high-resolution wireless temperature sensor based on microwave backscattering principles. The proposed design features a sandwich substrate-integrated waveguide (SIW) structure that incorporates a complementary split-ring resonator etched on the upper conductive layer of a printed circuit board (PCB) stack. This sandwich configuration integrates a temperature-sensitive CaTiO 3 dielectric core between two FR4 substrates ( ϵ r = 4.2), enabling enhanced electromagnetic field confinement and thermal frequency transduction. The sensor was fabricated using standard PCB processing techniques. For experimental characterization, the fabricated device was placed on a heating plate and interrogated wirelessly through a rectangular waveguide antenna connected to a vector network analyzer via a coaxial-to-waveguide converter. The compact sensor (36 mm × 36 mm × 3 mm) demonstrates stable operation over 25 °C–125 °C with 1.6 MHz °C −1 temperature-to-frequency resolution. The experimental results validate the design’s immunity to metallic interference while maintaining quadratic response characteristics ( R 2 = 0.999935) across the operational range. This study demonstrates the feasibility of the sandwich SIW sensor and its broad application prospects for wireless temperature measuring.
- 22 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 105115
Novel high-resolution wireless temperature sensor based on sandwich complementary split-ring resonator substrate-integrated waveguide structure
This paper presents a novel high-resolution wireless temperature sensor based on microwave backscattering principles. The proposed design features a sandwich substrate-integrated waveguide (SIW) structure that incorporates a complementary split-ring resonator etched on the upper conductive layer of a printed circuit board (PCB) stack. This sandwich configuration integrates a temperature-sensitive CaTiO 3 dielectric core between two FR4 substrates ( ϵ r = 4.2), enabling enhanced electromagnetic field confinement and thermal frequency transduction. The sensor was fabricated using standard PCB processing techniques. For experimental characterization, the fabricated device was placed on a heating plate and interrogated wirelessly through a rectangular waveguide antenna connected to a vector network analyzer via a coaxial-to-waveguide converter. The compact sensor (36 mm × 36 mm × 3 mm) demonstrates stable operation over 25 °C–125 °C with 1.6 MHz °C −1 temperature-to-frequency resolution. The experimental results validate the design’s immunity to metallic interference while maintaining quadratic response characteristics ( R 2 = 0.999935) across the operational range. This study demonstrates the feasibility of the sandwich SIW sensor and its broad application prospects for wireless temperature measuring.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 14688-14695
A Study of Self-Heating Effect Correction Methods for NTC Thermistors
Correcting for self-heating effects is crucial for minimizing uncertainties in negative temperature coefficient (NTC) thermistor thermometer measurements. This study examined a self-heating effect correction method for NTC thermistors at the triple point of water (TPW) and a water bath under varying currents. The resistance–temperature characteristics of the thermistors over a temperature range of -5 to 35 °C were determined. Both two-current and multi-current methods were applied to correct the self-heating effects in the thermistors. The results showed that excessive excitation current hindered accurate self-heating correction, while a minimal current would result in a high signal-to-noise ratio, with a recommended test current below 20 μA. Moreover, optimizing the current ratio in the two-current method significantly reduced the measurement uncertainty. The multi-current method further reduced the uncertainty, even though this reduction diminished as the number of excitation currents increased. The multi-current method increased the measurement time and experimental complexity. The self-heating effect and its uncertainty reduced with increasing temperature. Considering both measurement uncertainty and ease of implementation, an improved two-current method with a current ratio of 1:2 is suggested for the accurate measurement and correction of self-heating effects in thermistor thermometers. The self-heating effect from the measured resistance value across all temperature ranges should be corrected to ensure accurate and precise temperature measurements.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 14688-14695
A Study of Self-Heating Effect Correction Methods for NTC Thermistors
Correcting for self-heating effects is crucial for minimizing uncertainties in negative temperature coefficient (NTC) thermistor thermometer measurements. This study examined a self-heating effect correction method for NTC thermistors at the triple point of water (TPW) and a water bath under varying currents. The resistance–temperature characteristics of the thermistors over a temperature range of -5 to 35 °C were determined. Both two-current and multi-current methods were applied to correct the self-heating effects in the thermistors. The results showed that excessive excitation current hindered accurate self-heating correction, while a minimal current would result in a high signal-to-noise ratio, with a recommended test current below 20 μA. Moreover, optimizing the current ratio in the two-current method significantly reduced the measurement uncertainty. The multi-current method further reduced the uncertainty, even though this reduction diminished as the number of excitation currents increased. The multi-current method increased the measurement time and experimental complexity. The self-heating effect and its uncertainty reduced with increasing temperature. Considering both measurement uncertainty and ease of implementation, an improved two-current method with a current ratio of 1:2 is suggested for the accurate measurement and correction of self-heating effects in thermistor thermometers. The self-heating effect from the measured resistance value across all temperature ranges should be corrected to ensure accurate and precise temperature measurements.