Yu Xing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yu Xing has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Xinxia Cai
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
3 shared publications - Guihua Xiao
Beijing National Research Center for Information Science and Technology, Tsinghua University, Beijing, China.
2 shared publications - Shengwei Xu
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Yilin Song
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
2 shared publications - Deyong Chen
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
1 shared publication - Duli Yu
College of Information Science and Technology, Beijing University of Chemical and Technology, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 30 March 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (7) , 1223
Reduced Graphene Oxide and Gold Nanoparticles-Modified Electrochemical Aptasensor for Highly Sensitive Detection of Doxorubicin
Doxorubicin (DOX) is the most clinically important antibiotic in cancer treatment, but its severe cardiotoxicity and other side effects limit its clinical use. Therefore, monitoring DOX concentrations during therapy is essential to improve efficacy and reduce adverse effects. Here, we fabricated a sensitive electrochemical aptasensor for DOX detection. The sensor used gold wire as the working electrode and was modified with reduced graphene oxide (rGO)/gold nanoparticles (AuNPs) to improve the sensitivity. An aptamer was used as the recognition element for the DOX. The 5′ end of the aptamer was modified with a thiol group, and thus immobilized to the AuNPs, and the 3′ end was modified with methylene blue, which acts as the electron mediator. The combination between the aptamer and DOX would produce a binding-induced conformation, which changes the electron transfer rate, yielding a current change that correlates with the concentration of DOX. The aptasensor exhibited good linearity in the DOX concentration range of 0.3 μM to 6 μM, with a detection limit of 0.1 μM. In addition, the aptasensor was used for DOX detection in real samples and results, and showed good recovery. The proposed electrochemical aptasensor will provide a sensitive, fast, simple, and reliable new platform for detecting DOX.
- 30 March 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (7) , 1223
Open AccessReduced Graphene Oxide and Gold Nanoparticles-Modified Electrochemical Aptasensor for Highly Sensitive Detection of Doxorubicin
Doxorubicin (DOX) is the most clinically important antibiotic in cancer treatment, but its severe cardiotoxicity and other side effects limit its clinical use. Therefore, monitoring DOX concentrations during therapy is essential to improve efficacy and reduce adverse effects. Here, we fabricated a sensitive electrochemical aptasensor for DOX detection. The sensor used gold wire as the working electrode and was modified with reduced graphene oxide (rGO)/gold nanoparticles (AuNPs) to improve the sensitivity. An aptamer was used as the recognition element for the DOX. The 5′ end of the aptamer was modified with a thiol group, and thus immobilized to the AuNPs, and the 3′ end was modified with methylene blue, which acts as the electron mediator. The combination between the aptamer and DOX would produce a binding-induced conformation, which changes the electron transfer rate, yielding a current change that correlates with the concentration of DOX. The aptasensor exhibited good linearity in the DOX concentration range of 0.3 μM to 6 μM, with a detection limit of 0.1 μM. In addition, the aptasensor was used for DOX detection in real samples and results, and showed good recovery. The proposed electrochemical aptasensor will provide a sensitive, fast, simple, and reliable new platform for detecting DOX.
- Open Access
- 28 September 2020
- Published by MDPI AG in Biosensors
- Vol. 10 (10) , 136
Dopamine and Striatal Neuron Firing Respond to Frequency-Dependent DBS Detected by Microelectrode Arrays in the Rat Model of Parkinson’s Disease
(1) Background: Deep brain stimulation (DBS) is considered as an efficient treatment method for alleviating motor symptoms in Parkinson’s disease (PD), while different stimulation frequency effects on the specific neuron patterns at the cellular level remain unknown. (2) Methods: In this work, nanocomposites-modified implantable microelectrode arrays (MEAs) were fabricated to synchronously record changes of dopamine (DA) concentration and striatal neuron firing in the striatum during subthalamic nucleus DBS, and different responses of medium spiny projecting neurons (MSNs) and fast spiking interneurons (FSIs) to DBS were analyzed. (3) Results: DA concentration and striatal neuron spike firing rate showed a similar change as DBS frequency changed from 10 to 350 Hz. Note that the increases in DA concentration (3.11 ± 0.67 μM) and neural spike firing rate (15.24 ± 2.71 Hz) were maximal after the stimulation at 100 Hz. The MSNs firing response to DBS was significant, especially at 100 Hz, while the FSIs remained stable after various stimulations. (4) Conclusions: DBS shows the greatest regulatory effect on DA concentration and MSNs firing rate at 100 Hz stimulation. This implantable MEA in the recording of the neurotransmitter and neural spike pattern response to DBS provides a new insight to understand the mechanism of PD at the cellular level.
- 28 September 2020
- Published by MDPI AG in Biosensors
- Vol. 10 (10) , 136
Open AccessDopamine and Striatal Neuron Firing Respond to Frequency-Dependent DBS Detected by Microelectrode Arrays in the Rat Model of Parkinson’s Disease
(1) Background: Deep brain stimulation (DBS) is considered as an efficient treatment method for alleviating motor symptoms in Parkinson’s disease (PD), while different stimulation frequency effects on the specific neuron patterns at the cellular level remain unknown. (2) Methods: In this work, nanocomposites-modified implantable microelectrode arrays (MEAs) were fabricated to synchronously record changes of dopamine (DA) concentration and striatal neuron firing in the striatum during subthalamic nucleus DBS, and different responses of medium spiny projecting neurons (MSNs) and fast spiking interneurons (FSIs) to DBS were analyzed. (3) Results: DA concentration and striatal neuron spike firing rate showed a similar change as DBS frequency changed from 10 to 350 Hz. Note that the increases in DA concentration (3.11 ± 0.67 μM) and neural spike firing rate (15.24 ± 2.71 Hz) were maximal after the stimulation at 100 Hz. The MSNs firing response to DBS was significant, especially at 100 Hz, while the FSIs remained stable after various stimulations. (4) Conclusions: DBS shows the greatest regulatory effect on DA concentration and MSNs firing rate at 100 Hz stimulation. This implantable MEA in the recording of the neurotransmitter and neural spike pattern response to DBS provides a new insight to understand the mechanism of PD at the cellular level.
- Open Access
- 29 July 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (8) , 732
Flexible Electrocorticography Electrode Array for Epileptiform Electrical Activity Recording under Glutamate and GABA Modulation on the Primary Somatosensory Cortex of Rats
Epilepsy is a common neurological disorder. There is still a lack of methods to accurately detect cortical activity and locate lesions. In this work, a flexible electrocorticography (ECoG) electrode array based on polydimethylsiloxane (PDMS)-parylene was fabricated to detect epileptiform activity under glutamate (Glu) and gamma-aminobutyric acid (GABA) modulation on primary somatosensory cortex of rats. The electrode with a thickness of 20 μm has good flexibility to establish reliable contact with the cortex. Fourteen recording sites with a diameter of 60 μm are modified by electroplating platinum black nanoparticles, which effectively improve the performance with lower impedance, obtaining a sensitive sensing interface. The electrode enables real-time capturing changes in neural activity under drug modulation. Under Glu modulation, neuronal populations showed abnormal excitability, manifested as hypsarrhythmia rhythm and continuous or periodic spike wave epileptiform activity, with power increasing significantly. Under GABA modulation, the excitement was inhibited, with amplitude and power reduced to normal. The flexible ECoG electrode array could monitor cortical activity, providing us with an effective tool for further studying epilepsy and locating lesions.
- 29 July 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (8) , 732
Open AccessFlexible Electrocorticography Electrode Array for Epileptiform Electrical Activity Recording under Glutamate and GABA Modulation on the Primary Somatosensory Cortex of Rats
Epilepsy is a common neurological disorder. There is still a lack of methods to accurately detect cortical activity and locate lesions. In this work, a flexible electrocorticography (ECoG) electrode array based on polydimethylsiloxane (PDMS)-parylene was fabricated to detect epileptiform activity under glutamate (Glu) and gamma-aminobutyric acid (GABA) modulation on primary somatosensory cortex of rats. The electrode with a thickness of 20 μm has good flexibility to establish reliable contact with the cortex. Fourteen recording sites with a diameter of 60 μm are modified by electroplating platinum black nanoparticles, which effectively improve the performance with lower impedance, obtaining a sensitive sensing interface. The electrode enables real-time capturing changes in neural activity under drug modulation. Under Glu modulation, neuronal populations showed abnormal excitability, manifested as hypsarrhythmia rhythm and continuous or periodic spike wave epileptiform activity, with power increasing significantly. Under GABA modulation, the excitement was inhibited, with amplitude and power reduced to normal. The flexible ECoG electrode array could monitor cortical activity, providing us with an effective tool for further studying epilepsy and locating lesions.