Una Molnar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Una Molnar has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jovana Nikolov
Faculty of Sciences, University of Novi Sad, Novi Sad, Serbia
2 shared publications - Olivera Nikolić
Faculty of Medicine, University of Novi Sad, Novi Sad, Serbia.
2 shared publications Viktor Till
2 shared publications- Viktor Till
Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia; Center for Radiology, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia
2 shared publications Aleksandar M. Miladinović
Medical Physics Department, University Clinical Center Kragujevac, Kragujevac, Serbia
1 shared publicationDejana Hornjak
1 shared publication
Latest Publications
- 17 January 2025
- Published by Elsevier in Physica Medica
- Vol. 130, 104899
Compressed SENSE acceleration factor influence on magnetic resonance image quality in patients with endometrial cancer
- 17 January 2025
- Published by Elsevier in Physica Medica
- Vol. 130, 104899
Compressed SENSE acceleration factor influence on magnetic resonance image quality in patients with endometrial cancer
- Open Access
- 1 January 2022
- Published by RAD Centre
Implementation of a new IAEA remote and automated quality control program for radiography equipment
- 1 January 2022
- Published by RAD Centre
Open AccessImplementation of a new IAEA remote and automated quality control program for radiography equipment
- Open Access
- 1 January 2022
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 37 (1) , 78-83
Absorbed dose distribution in human eye simulated by FOTELP-VOX code and verified by volumetric modulated arc therapy treatment plan
This paper illustrates the potential of the FOTELP-VOX code, a modification of the general-purpose FOTELP code, combining Monte Carlo techniques to simulate particle transportation from an external source through the internal organs, resulting in a 3-D absorbed dose distribution. The study shows the comparison of results obtained by FOTELP software and the volumetric modulated arc therapy technique. This planning technique with two full arcs was applied, and the plan was created to destroy the diseased tissue in the eye tumor bed and avoid damage to surrounding healthy tissue, for one patient. The dose coverage, homogeneity index, conformity index of the target, and the dose volumes of critical structures were calculated. Good agreement of the results for absorbed dose in the human eye was obtained using these two techniques.
- 1 January 2022
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 37 (1) , 78-83
Open AccessAbsorbed dose distribution in human eye simulated by FOTELP-VOX code and verified by volumetric modulated arc therapy treatment plan
This paper illustrates the potential of the FOTELP-VOX code, a modification of the general-purpose FOTELP code, combining Monte Carlo techniques to simulate particle transportation from an external source through the internal organs, resulting in a 3-D absorbed dose distribution. The study shows the comparison of results obtained by FOTELP software and the volumetric modulated arc therapy technique. This planning technique with two full arcs was applied, and the plan was created to destroy the diseased tissue in the eye tumor bed and avoid damage to surrounding healthy tissue, for one patient. The dose coverage, homogeneity index, conformity index of the target, and the dose volumes of critical structures were calculated. Good agreement of the results for absorbed dose in the human eye was obtained using these two techniques.
- 1 August 2021
- Published by Elsevier in Physica Medica
- Vol. 88, 158-166
Diagnostic quality assessment of compressed SENSE accelerated magnetic resonance images in standard neuroimaging protocol: Choosing the right acceleration
- 1 August 2021
- Published by Elsevier in Physica Medica
- Vol. 88, 158-166
Diagnostic quality assessment of compressed SENSE accelerated magnetic resonance images in standard neuroimaging protocol: Choosing the right acceleration
- 30 July 2020
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 34 (2) , 273-283
Diffusion-weighted imaging in the assessment of renal function in patients with diabetes mellitus type 2
Objective Investigation of functional magnetic resonance (MR) imaging role in early diagnosis of diabetic nephropathy (DN) in patients with diabetes mellitus (DM) type 2, by quantification of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values. Material and methods 10 healthy volunteers and 91 DM type 2 patients were scanned using diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) sequences. Patients were divided into four groups based on the estimated glomerular filtration value (eGFR). ADC and FA values, calculated in six regions of interest in each kidney (cortex and medulla), were compared to eGFR and laboratory parameters of renal function. Results ADC values of DM patients were higher in the cortex than in the medulla (p < 0.01), while FA values were higher in the medulla (p = 0.284). Creatinine, cystatin C negatively correlated with ADC (cortex, medulla, parenchyma). Medullary FA were lower in DM patients and positively correlated with the eGFR (p = 0.049). Tractography showed disturbed structure in patients with impaired renal function. Discussion Medullary FA value is a more sensitive parameter than parenchymal ADC in the early detection of renal damage in DM patients. ADC and FA values are significant in the diagnosis of DN; further research is needed for the update and refinement of the established recommendations.
- 30 July 2020
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 34 (2) , 273-283
Diffusion-weighted imaging in the assessment of renal function in patients with diabetes mellitus type 2
Objective Investigation of functional magnetic resonance (MR) imaging role in early diagnosis of diabetic nephropathy (DN) in patients with diabetes mellitus (DM) type 2, by quantification of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values. Material and methods 10 healthy volunteers and 91 DM type 2 patients were scanned using diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) sequences. Patients were divided into four groups based on the estimated glomerular filtration value (eGFR). ADC and FA values, calculated in six regions of interest in each kidney (cortex and medulla), were compared to eGFR and laboratory parameters of renal function. Results ADC values of DM patients were higher in the cortex than in the medulla (p < 0.01), while FA values were higher in the medulla (p = 0.284). Creatinine, cystatin C negatively correlated with ADC (cortex, medulla, parenchyma). Medullary FA were lower in DM patients and positively correlated with the eGFR (p = 0.049). Tractography showed disturbed structure in patients with impaired renal function. Discussion Medullary FA value is a more sensitive parameter than parenchymal ADC in the early detection of renal damage in DM patients. ADC and FA values are significant in the diagnosis of DN; further research is needed for the update and refinement of the established recommendations.