Geert Geleijnse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Geert Geleijnse has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Bernd Rieger
Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
2 shared publications - Benjamin Yael Gravesteijn
Department of Obstetrics & Gynaecology, Amsterdam University Medical Center, Amsterdam, the Netherlands and Amsterdam Reproduction & Development, Amsterdam, Netherlands (the); Department of Public Health, Erasmus MC, University Medical Center Rotterdam, Rotterdam, Netherlands (the)
1 shared publication Bernd Rieger
Delft University of Technology, Department of Imaging Physics, Faculty of Applied Sciences, Delft, The Netherlands
1 shared publicationCollaborators
1 shared publication- Cornelis Verhoef
Department of Surgery, Erasmus Medical Centre, Rotterdam, The Netherlands
1 shared publication - Céline van Lint
Department of Quality and Patient Care, Erasmus MC University Medical Center, Rotterdam, the Netherlands
1 shared publication
Latest Publications
- Open Access
- 4 November 2026
- Published by Elsevier in Hearing Research
- Vol. 483
Exploring the effect of attention on the acoustic change complex: cross-condition reliability and between-subject variability
- 4 November 2026
- Published by Elsevier in Hearing Research
- Vol. 483
Open AccessExploring the effect of attention on the acoustic change complex: cross-condition reliability and between-subject variability
- Open Access
- 17 August 2023
- Published by Wiley in The Laryngoscope
- Vol. 134 (2) , 842-847
Edge Enhancement Optimization in Flexible Endoscopic Images to the Perception of Ear, Nose and Throat Professionals
Objectives: Digital endoscopes are connected to a video processor that applies various operations to process the image. One of those operations is edge enhancement that sharpens the image. The purpose of this study was to (1) quantify the level of edge enhancement, (2) measure the effect on sharpness and image noise, and (3) study the influence of edge enhancement on image quality perceived by ENT professionals.Methods: Three digital flexible endoscopic systems were included. The level of edge enhancement and the influence on sharpness and noise were measured in vitro, while systematically varying the levels of edge enhancement. In vivo images were captured at identical levels of one healthy larynx. Each series of in vivo images was presented to 39 ENT professionals according to a forced pairwise comparison test, to select the image with the best image quality for diagnostic purposes. The numbers of votes were converted to a psychometric scale of just noticeable differences (JND) according to the Thurstone V model.Results: The maximum level of edge enhancement varied per endoscopic system and ranged from 0.8 to 1.2. Edge enhancement increased sharpness and noise. Images with edge enhancement were unanimously preferred to images without edge enhancement. The quality difference with respect to zero edge enhancement reaches an optimum at levels between 0.7 and 0.9.Conclusion: Edge enhancement has a major impact on sharpness, noise, and the resulting perceived image quality. We conclude that ENT professionals benefit from this video processing and should verify if their equipment is optimally configured.Level of Evidence: NA Laryngoscope, 134:842–847, 2024
- 17 August 2023
- Published by Wiley in The Laryngoscope
- Vol. 134 (2) , 842-847
Open AccessEdge Enhancement Optimization in Flexible Endoscopic Images to the Perception of Ear, Nose and Throat Professionals
Objectives: Digital endoscopes are connected to a video processor that applies various operations to process the image. One of those operations is edge enhancement that sharpens the image. The purpose of this study was to (1) quantify the level of edge enhancement, (2) measure the effect on sharpness and image noise, and (3) study the influence of edge enhancement on image quality perceived by ENT professionals.Methods: Three digital flexible endoscopic systems were included. The level of edge enhancement and the influence on sharpness and noise were measured in vitro, while systematically varying the levels of edge enhancement. In vivo images were captured at identical levels of one healthy larynx. Each series of in vivo images was presented to 39 ENT professionals according to a forced pairwise comparison test, to select the image with the best image quality for diagnostic purposes. The numbers of votes were converted to a psychometric scale of just noticeable differences (JND) according to the Thurstone V model.Results: The maximum level of edge enhancement varied per endoscopic system and ranged from 0.8 to 1.2. Edge enhancement increased sharpness and noise. Images with edge enhancement were unanimously preferred to images without edge enhancement. The quality difference with respect to zero edge enhancement reaches an optimum at levels between 0.7 and 0.9.Conclusion: Edge enhancement has a major impact on sharpness, noise, and the resulting perceived image quality. We conclude that ENT professionals benefit from this video processing and should verify if their equipment is optimally configured.Level of Evidence: NA Laryngoscope, 134:842–847, 2024
- Open Access
- 1 July 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (07) , 079801-1
Influence of edge enhancement applied in endoscopic systems on sharpness and noise (Erratum)
The erratum corrects a typo in Eq. (4) of the published article.
- 1 July 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (07) , 079801-1
Open AccessInfluence of edge enhancement applied in endoscopic systems on sharpness and noise (Erratum)
The erratum corrects a typo in Eq. (4) of the published article.
- Open Access
- 6 October 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (10) , 106001-15
Influence of edge enhancement applied in endoscopic systems on sharpness and noise
SignificanceFlexible endoscopes are essential for medical internal examinations. Digital endoscopes are connected to a video processor that can apply various operations to enhance the image. One of those operations is edge enhancement, which has a major impact on the perceived image quality by medical professionals. However, the specific methods and parameters of this operation are undisclosed and the arbitrary units to express the level of edge enhancement differ per video processor.AimObjectively quantify the level of edge enhancement from the recorded images alone, and measure the effect on sharpness and noise.ApproachEdge enhancement was studied in four types of flexible digital ear nose and throat endoscopes. Measurements were performed using slanted edges and gray patches. The level of edge enhancement was determined by subtracting the step response of an image without edge enhancement from images with selected settings of edge enhancement and measuring the resulting peak-to-peak differences. These values were then normalized by the step size. Sharpness was characterized by observing the normalized modulation transfer function (MTF) and computing the spatial frequency at 50% MTF. The noise was measured on the gray patches and computed as a weighted sum of variances from the luminance and two chrominance channels of the pixel values.ResultsThe measured levels were consistent with the level set via the user interface on the video processor and varied typically from 0 to 1.3. Both sharpness and noise increase with larger levels of edge enhancement with factors of 3 and 4 respectively.ConclusionsThe presented method overcomes the issue of vendors expressing the level of edge enhancement each differently in arbitrary units. This allows us to compare the effects, and we can start exploring the relationship with the subjectively perceived image quality by medical professionals to find substantiated optimal settings.
- 6 October 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (10) , 106001-15
Open AccessInfluence of edge enhancement applied in endoscopic systems on sharpness and noise
SignificanceFlexible endoscopes are essential for medical internal examinations. Digital endoscopes are connected to a video processor that can apply various operations to enhance the image. One of those operations is edge enhancement, which has a major impact on the perceived image quality by medical professionals. However, the specific methods and parameters of this operation are undisclosed and the arbitrary units to express the level of edge enhancement differ per video processor.AimObjectively quantify the level of edge enhancement from the recorded images alone, and measure the effect on sharpness and noise.ApproachEdge enhancement was studied in four types of flexible digital ear nose and throat endoscopes. Measurements were performed using slanted edges and gray patches. The level of edge enhancement was determined by subtracting the step response of an image without edge enhancement from images with selected settings of edge enhancement and measuring the resulting peak-to-peak differences. These values were then normalized by the step size. Sharpness was characterized by observing the normalized modulation transfer function (MTF) and computing the spatial frequency at 50% MTF. The noise was measured on the gray patches and computed as a weighted sum of variances from the luminance and two chrominance channels of the pixel values.ResultsThe measured levels were consistent with the level set via the user interface on the video processor and varied typically from 0 to 1.3. Both sharpness and noise increase with larger levels of edge enhancement with factors of 3 and 4 respectively.ConclusionsThe presented method overcomes the issue of vendors expressing the level of edge enhancement each differently in arbitrary units. This allows us to compare the effects, and we can start exploring the relationship with the subjectively perceived image quality by medical professionals to find substantiated optimal settings.
- Open Access
Minimizing Population Health Loss in Times of Scarce Surgical Capacity
Background: COVID-19 has put unprecedented pressure on healthcare systems worldwide, leading to a reduction of the available healthcare capacity. Our objective was to develop a decision model that supports prioritization of care from a utilitarian perspective, which is to minimize population health loss. Methods: A cohort state-transition model was developed and applied to 43 semi-elective non-paediatric surgeries commonly performed in academic hospitals. Scenarios of delaying surgery from two weeks were compared with delaying up to one year, and no surgery at all. Model parameters were based on registries, scientific literature, and the World Health Organization global burden of disease study. For each surgery, the urgency was estimated as the average expected loss of Quality-Adjusted Life-Years (QALYs) per month. Results: Given the best available evidence, the two most urgent surgeries were bypass surgery for Fontaine III/IV peripheral arterial disease (0.23 QALY loss/month, 95%-CI: 0.09-0.24) and transaortic valve implantation (0.15 QALY loss/month, 95%-CI: 0.09-0.24). The two least urgent surgeries were placing a shunt for dialysis (0.01, 95%-CI: 0.005-0.01) and thyroid carcinoma resection (0.01, 95%-CI: 0.01-0.02): these surgeries were associated with a limited amount of health lost on the waiting list. Conclusion: Expected health loss due to surgical delay can be objectively calculated with our decision model based on best available evidence, which can guide prioritization of surgeries to minimize population health loss in times of scarcity. This tool should yet be placed in the context of different ethical perspectives and combined with capacity management tools to facilitate large-scale implementation. Summary box: What is already known on this topic: The perspective of maximizing population health, a utilitarian ethical perspective, has been described to be most defendable in times of scarcity. To prioritize surgical patients, literature mainly discusses approaches which are intra-disciplinary (e.g. within gynecological or oncological surgery) and mostly existed of narrative reviews of the literature. Some decision tools were developed, which rely on the consensus of experts on various measures of urgency (e.g. health benefit, or time until inoperable). No approach was found which transparently weighs objective factors in order to quantify a clinically relevant measure of urgency. What this study adds: In contrast to previously developed approaches, our approach transparently and consistently aggregates best available objective evidence across disciplines. This novel aggregated urgency measure can be easily linked with capacity management tools. Our approach can help to minimize health losses when trying to overcome delay in surgeries in times of surgical scarcity, during the COVID-19 pandemic and beyond.
Open AccessMinimizing Population Health Loss in Times of Scarce Surgical Capacity
Background: COVID-19 has put unprecedented pressure on healthcare systems worldwide, leading to a reduction of the available healthcare capacity. Our objective was to develop a decision model that supports prioritization of care from a utilitarian perspective, which is to minimize population health loss. Methods: A cohort state-transition model was developed and applied to 43 semi-elective non-paediatric surgeries commonly performed in academic hospitals. Scenarios of delaying surgery from two weeks were compared with delaying up to one year, and no surgery at all. Model parameters were based on registries, scientific literature, and the World Health Organization global burden of disease study. For each surgery, the urgency was estimated as the average expected loss of Quality-Adjusted Life-Years (QALYs) per month. Results: Given the best available evidence, the two most urgent surgeries were bypass surgery for Fontaine III/IV peripheral arterial disease (0.23 QALY loss/month, 95%-CI: 0.09-0.24) and transaortic valve implantation (0.15 QALY loss/month, 95%-CI: 0.09-0.24). The two least urgent surgeries were placing a shunt for dialysis (0.01, 95%-CI: 0.005-0.01) and thyroid carcinoma resection (0.01, 95%-CI: 0.01-0.02): these surgeries were associated with a limited amount of health lost on the waiting list. Conclusion: Expected health loss due to surgical delay can be objectively calculated with our decision model based on best available evidence, which can guide prioritization of surgeries to minimize population health loss in times of scarcity. This tool should yet be placed in the context of different ethical perspectives and combined with capacity management tools to facilitate large-scale implementation. Summary box: What is already known on this topic: The perspective of maximizing population health, a utilitarian ethical perspective, has been described to be most defendable in times of scarcity. To prioritize surgical patients, literature mainly discusses approaches which are intra-disciplinary (e.g. within gynecological or oncological surgery) and mostly existed of narrative reviews of the literature. Some decision tools were developed, which rely on the consensus of experts on various measures of urgency (e.g. health benefit, or time until inoperable). No approach was found which transparently weighs objective factors in order to quantify a clinically relevant measure of urgency. What this study adds: In contrast to previously developed approaches, our approach transparently and consistently aggregates best available objective evidence across disciplines. This novel aggregated urgency measure can be easily linked with capacity management tools. Our approach can help to minimize health losses when trying to overcome delay in surgeries in times of surgical scarcity, during the COVID-19 pandemic and beyond.