Daniel Vong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Vong has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Adam James Moule
Department of Chemical Engineering
6 shared publications Luke L. Daemen
Neutron Scattering Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830, United States
4 shared publications- Eric Novak
Neutron Scattering Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, United States
3 shared publications - Farahnaz Maleki
Department of Chemical Engineering
2 shared publications - John Edward Anthony
University of Kentucky
2 shared publications - Luke L. Daemen
Neutron Scattering Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, United States
2 shared publications
Latest Publications
- 5 May 2024
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 36 (9) , 4794-4805
Design Rules to Optimize the Intermolecular and Long-Range Packing of Organic Semiconductor Crystals
- 5 May 2024
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 36 (9) , 4794-4805
Design Rules to Optimize the Intermolecular and Long-Range Packing of Organic Semiconductor Crystals
- 25 January 2024
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 15 (5) , 1188-1194
Measuring Intermolecular Excited State Geometry for Favorable Singlet Fission in Tetracene
Singlet fission (SF) is the process of converting an excited singlet to a pair of excited triplets. Harvesting two charges from a single photon has the potential to increase photovoltaic device efficiencies. Acenes, such as tetracene and pentacene, are model molecules for studying SF. Despite SF being an endoergic process for tetracene and exoergic for pentacene, both acenes exhibit near unity SF quantum efficiencies, raising questions about how tetracene can overcome the energy barrier. Here, we use recently developed instrumentation to measure inelastic neutron scattering (INS) while optically exciting the model molecules using two different excitation energies. The spectroscopic results reveal intermolecular structural relaxation due to the presence of a triplet excited state. The structural dynamics of the combined excited state molecule and surrounding tetracene molecules are further studied using time-dependent density functional theory (TD-DFT), which shows that the singlet and triplet levels shift due to the excited state geometry, reducing the uphill energy barrier for SF to within kT.
- 25 January 2024
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 15 (5) , 1188-1194
Measuring Intermolecular Excited State Geometry for Favorable Singlet Fission in Tetracene
Singlet fission (SF) is the process of converting an excited singlet to a pair of excited triplets. Harvesting two charges from a single photon has the potential to increase photovoltaic device efficiencies. Acenes, such as tetracene and pentacene, are model molecules for studying SF. Despite SF being an endoergic process for tetracene and exoergic for pentacene, both acenes exhibit near unity SF quantum efficiencies, raising questions about how tetracene can overcome the energy barrier. Here, we use recently developed instrumentation to measure inelastic neutron scattering (INS) while optically exciting the model molecules using two different excitation energies. The spectroscopic results reveal intermolecular structural relaxation due to the presence of a triplet excited state. The structural dynamics of the combined excited state molecule and surrounding tetracene molecules are further studied using time-dependent density functional theory (TD-DFT), which shows that the singlet and triplet levels shift due to the excited state geometry, reducing the uphill energy barrier for SF to within kT.
- Open Access
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators
Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. The sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
Open AccessCompact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators
Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. The sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.
- Open Access
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
Photochemistry sample sticks for inelastic neutron scattering
Every material experiences atomic and molecular motions that are generally termed vibrations in gases and liquids or phonons in solid state materials. Optical spectroscopy techniques, such as Raman, infrared absorption spectroscopy, or inelastic neutron scattering (INS), can be used to measure the vibrational/phonon spectrum of ground state materials properties. A variety of optical pump probe spectroscopies enable the measurement of excited states or elucidate photochemical reaction pathways and kinetics. So far, it has not been possible to study photoactive materials or processes in situ using INS due to the mismatch between neutron and photon penetration depths, differences between the flux density of photons and neutrons, cryogenic temperatures for INS measurements, vacuum conditions, and a lack of optical access to the sample space. These experimental hurdles have resulted in very limited photochemistry studies using INS. Here we report on the design of two different photochemistry sample sticks that overcome these experimental hurdles to enable in situ photochemical studies using INS, specifically at the VISION instrument at Oak Ridge National Laboratory. We demonstrate the use of these new measurement capabilities through (1) the in situ photodimerization of anthracene and (2) the in situ photopolymerization of a 405 nm photoresin using 405 nm excitation as simple test cases. These new measurement apparatus broaden the science enabled by INS to include photoactive materials, optically excited states, and photoinitiated reactions.
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
Open AccessPhotochemistry sample sticks for inelastic neutron scattering
Every material experiences atomic and molecular motions that are generally termed vibrations in gases and liquids or phonons in solid state materials. Optical spectroscopy techniques, such as Raman, infrared absorption spectroscopy, or inelastic neutron scattering (INS), can be used to measure the vibrational/phonon spectrum of ground state materials properties. A variety of optical pump probe spectroscopies enable the measurement of excited states or elucidate photochemical reaction pathways and kinetics. So far, it has not been possible to study photoactive materials or processes in situ using INS due to the mismatch between neutron and photon penetration depths, differences between the flux density of photons and neutrons, cryogenic temperatures for INS measurements, vacuum conditions, and a lack of optical access to the sample space. These experimental hurdles have resulted in very limited photochemistry studies using INS. Here we report on the design of two different photochemistry sample sticks that overcome these experimental hurdles to enable in situ photochemical studies using INS, specifically at the VISION instrument at Oak Ridge National Laboratory. We demonstrate the use of these new measurement capabilities through (1) the in situ photodimerization of anthracene and (2) the in situ photopolymerization of a 405 nm photoresin using 405 nm excitation as simple test cases. These new measurement apparatus broaden the science enabled by INS to include photoactive materials, optically excited states, and photoinitiated reactions.
- 13 June 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 13 (24) , 5530-5537
Quantitative Hole Mobility Simulation and Validation in Substituted Acenes
Knowledge of the full phonon spectrum is essential to accurately calculate the dynamic disorder (σ) and hole mobility (μh) in organic semiconductors (OSCs). However, most vibrational spectroscopy techniques under-measure the phonons, thus limiting the phonon validation. Here, we measure and model the full phonon spectrum using multiple spectroscopic techniques and predict μh using σ from only the Γ-point and the full Brillouin zone (FBZ). We find that only inelastic neutron scattering (INS) provides validation of all phonon modes, and that σ in a set of small molecule semiconductors can be miscalculated by up to 28% when comparing Γ-point against FBZ calculations. A subsequent mode analysis shows that many modes contribute to σ and that no single mode dominates. Our results demonstrate the importance of a thoroughly validated phonon calculation, and a need to develop design rules considering the full spectrum of phonon modes.
- 13 June 2022
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 13 (24) , 5530-5537
Quantitative Hole Mobility Simulation and Validation in Substituted Acenes
Knowledge of the full phonon spectrum is essential to accurately calculate the dynamic disorder (σ) and hole mobility (μh) in organic semiconductors (OSCs). However, most vibrational spectroscopy techniques under-measure the phonons, thus limiting the phonon validation. Here, we measure and model the full phonon spectrum using multiple spectroscopic techniques and predict μh using σ from only the Γ-point and the full Brillouin zone (FBZ). We find that only inelastic neutron scattering (INS) provides validation of all phonon modes, and that σ in a set of small molecule semiconductors can be miscalculated by up to 28% when comparing Γ-point against FBZ calculations. A subsequent mode analysis shows that many modes contribute to σ and that no single mode dominates. Our results demonstrate the importance of a thoroughly validated phonon calculation, and a need to develop design rules considering the full spectrum of phonon modes.
- Open Access
- 24 November 2021
- Published by American Chemical Society (ACS) in Journal of Chemical Theory and Computation
- Vol. 17 (12) , 7313-7320
Comparing the Expense and Accuracy of Methods to Simulate Atomic Vibrations in Rubrene
Atomic vibrations can inform about materials properties from hole transport in organic semiconductors to correlated disorder in metal–organic frameworks. Currently, there are several methods for predicting these vibrations using simulations, but the accuracy–efficiency tradeoffs have not been examined in depth. In this study, rubrene is used as a model system to predict atomic vibrational properties using six different simulation methods: density functional theory, density functional tight binding, density functional tight binding with a Chebyshev polynomial-based correction, a trained machine learning model, a pretrained machine learning model called ANI-1, and a classical forcefield model. The accuracy of each method is evaluated by comparison to the experimental inelastic neutron scattering spectrum. All methods discussed here show some accuracy across a wide energy region, though the Chebyshev-corrected tight-binding method showed the optimal combination of high accuracy with low expense. We then offer broad simulation guidelines to yield efficient, accurate results for inelastic neutron scattering spectrum prediction.
- 24 November 2021
- Published by American Chemical Society (ACS) in Journal of Chemical Theory and Computation
- Vol. 17 (12) , 7313-7320
Open AccessComparing the Expense and Accuracy of Methods to Simulate Atomic Vibrations in Rubrene
Atomic vibrations can inform about materials properties from hole transport in organic semiconductors to correlated disorder in metal–organic frameworks. Currently, there are several methods for predicting these vibrations using simulations, but the accuracy–efficiency tradeoffs have not been examined in depth. In this study, rubrene is used as a model system to predict atomic vibrational properties using six different simulation methods: density functional theory, density functional tight binding, density functional tight binding with a Chebyshev polynomial-based correction, a trained machine learning model, a pretrained machine learning model called ANI-1, and a classical forcefield model. The accuracy of each method is evaluated by comparison to the experimental inelastic neutron scattering spectrum. All methods discussed here show some accuracy across a wide energy region, though the Chebyshev-corrected tight-binding method showed the optimal combination of high accuracy with low expense. We then offer broad simulation guidelines to yield efficient, accurate results for inelastic neutron scattering spectrum prediction.
- Open Access
- 30 July 2020
- Published by Public Library of Science (PLoS) in PLOS Genetics
- Vol. 16 (7) , e1008904
PCH-2 collaborates with CMT-1 to proofread meiotic homolog interactions
The conserved ATPase, PCH-2/TRIP13, is required during both the spindle checkpoint and meiotic prophase. However, its specific role in regulating meiotic homolog pairing, synapsis and recombination has been enigmatic. Here, we report that this enzyme is required to proofread meiotic homolog interactions. We generated a mutant version of PCH-2 in C. elegans that binds ATP but cannot hydrolyze it: pch-2E253Q. In vitro, this mutant can bind a known substrate but is unable to remodel it. This mutation results in some non-homologous synapsis and impaired crossover assurance. Surprisingly, worms with a null mutation in PCH-2’s adapter protein, CMT-1, the ortholog of p31comet, localize PCH-2 to meiotic chromosomes, exhibit non-homologous synapsis and lose crossover assurance. The similarity in phenotypes between cmt-1 and pch-2E253Q mutants suggest that PCH-2 can bind its meiotic substrates in the absence of CMT-1, in contrast to its role during the spindle checkpoint, but requires its adapter to hydrolyze ATP and remodel them. The production of sperm and eggs for sexual reproduction depends on meiosis. During this specialized cell division, homologous chromosomes pair, synapse and undergo meiotic recombination so that they are linked by at least one chiasma to promote their proper segregation. How homologous chromosomes ensure that these important interactions are with the correct partner is currently unknown. Here, we show that PCH-2 and its adapter protein, CMT-1, proofread homolog interactions to promote their fidelity and proper meiotic chromosome segregation.
- 30 July 2020
- Published by Public Library of Science (PLoS) in PLOS Genetics
- Vol. 16 (7) , e1008904
Open AccessPCH-2 collaborates with CMT-1 to proofread meiotic homolog interactions
The conserved ATPase, PCH-2/TRIP13, is required during both the spindle checkpoint and meiotic prophase. However, its specific role in regulating meiotic homolog pairing, synapsis and recombination has been enigmatic. Here, we report that this enzyme is required to proofread meiotic homolog interactions. We generated a mutant version of PCH-2 in C. elegans that binds ATP but cannot hydrolyze it: pch-2E253Q. In vitro, this mutant can bind a known substrate but is unable to remodel it. This mutation results in some non-homologous synapsis and impaired crossover assurance. Surprisingly, worms with a null mutation in PCH-2’s adapter protein, CMT-1, the ortholog of p31comet, localize PCH-2 to meiotic chromosomes, exhibit non-homologous synapsis and lose crossover assurance. The similarity in phenotypes between cmt-1 and pch-2E253Q mutants suggest that PCH-2 can bind its meiotic substrates in the absence of CMT-1, in contrast to its role during the spindle checkpoint, but requires its adapter to hydrolyze ATP and remodel them. The production of sperm and eggs for sexual reproduction depends on meiosis. During this specialized cell division, homologous chromosomes pair, synapse and undergo meiotic recombination so that they are linked by at least one chiasma to promote their proper segregation. How homologous chromosomes ensure that these important interactions are with the correct partner is currently unknown. Here, we show that PCH-2 and its adapter protein, CMT-1, proofread homolog interactions to promote their fidelity and proper meiotic chromosome segregation.