Claudia Santiviago
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Claudia Santiviago has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Elena Castelló
Biotechnological Processes for the Environment Group, Faculty of Engineering, Universidad de la República, CP: 11300, Montevideo, Uruguay
2 shared publications - Florencia Caro
Biotechnological Processes for the Environment Group, Faculty of Engineering, Universidad de la República, CP: 11300, Montevideo, Uruguay
2 shared publications Agustina Yelpo
Biotechnological Processes for the Environment Group, Faculty of Engineering, Universidad de la República, CP: 11300, Montevideo, Uruguay
1 shared publication- Axel Ríos
Biotechnological Processes for the Environment Group, Faculty of Engineering, Universidad de la República, CP: 11300, Montevideo, Uruguay
1 shared publication - Diego Rossit
Universidad Nacional del Sur
1 shared publication Elena Castelló
Biotechnological Processes for the Environment Group, Faculty of Engineering Universidad de la República Montevideo Uruguay
1 shared publication
Latest Publications
- 7 January 2026
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 104 (7) , 3369-3389
Reparameterization of the Monod equation for optimum experimental design and enhanced estimation of model parameters: Application to the nitrification kinetics
The Monod equation is frequently used for modelling of the microbial growth kinetics. Traditionally, the estimation of the Monod parameters is conducted through sampling at arbitrary times, which can lead to unnecessary experimental workload and high parameter uncertainties. In this context, the present manuscript originally applies a nonlinear reparameterized form of the Monod equation that allows the optimal experimental design for the Monod reparameterized equation (OED‐R) and improve the statistical quality of parameter estimation, which can lead to estimation of more precise and uncorrelated transformed model parameters with smaller number of experiments. Using nitrification as a case study, it is shown that OED‐R can be used to strategically select sampling times during critical phases of the kinetic trajectory, where the system sensitivity to parameter changes is at its peak. This approach can simultaneously enhance the precision and efficiency of experiments by reducing the number of required samples and minimizing parameter uncertainties and correlation during estimation.
- 7 January 2026
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 104 (7) , 3369-3389
Reparameterization of the Monod equation for optimum experimental design and enhanced estimation of model parameters: Application to the nitrification kinetics
The Monod equation is frequently used for modelling of the microbial growth kinetics. Traditionally, the estimation of the Monod parameters is conducted through sampling at arbitrary times, which can lead to unnecessary experimental workload and high parameter uncertainties. In this context, the present manuscript originally applies a nonlinear reparameterized form of the Monod equation that allows the optimal experimental design for the Monod reparameterized equation (OED‐R) and improve the statistical quality of parameter estimation, which can lead to estimation of more precise and uncorrelated transformed model parameters with smaller number of experiments. Using nitrification as a case study, it is shown that OED‐R can be used to strategically select sampling times during critical phases of the kinetic trajectory, where the system sensitivity to parameter changes is at its peak. This approach can simultaneously enhance the precision and efficiency of experiments by reducing the number of required samples and minimizing parameter uncertainties and correlation during estimation.
- 23 May 2025
- Published by Elsevier in Journal of Environmental Management
- Vol. 387, 125891
Phosphorus recovery from EBPR sludges: influence of sludge source and measurement challenges after thermal hydrolysis
- 23 May 2025
- Published by Elsevier in Journal of Environmental Management
- Vol. 387, 125891
Phosphorus recovery from EBPR sludges: influence of sludge source and measurement challenges after thermal hydrolysis
- 26 March 2025
- Published by Springer Nature
- p. 176-189
Multi-objective Optimization for the Operation of a Physicochemical Phosphorus Removal System
- 26 March 2025
- Published by Springer Nature
- p. 176-189
Multi-objective Optimization for the Operation of a Physicochemical Phosphorus Removal System
- 21 March 2025
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 13 (3)
Data-driven models for phosphorus forecasting in wastewater treatment plants: A tool to enhance operation
- 21 March 2025
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 13 (3)
Data-driven models for phosphorus forecasting in wastewater treatment plants: A tool to enhance operation
- 2 March 2020
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 102 (5) , 1141-1151
A simple spectrophotometric method to determine phytic acid in poultry wastewater without acid digestion
Frequently, wastewater from treatment plants associated with animal husbandry, mainly animal feeding operations, are used to irrigate near agricultural lands based on nitrogen requirements. To avoid soil phosphorus accumulation owing to its long-term application, it is necessary to achieve lower levels of total phosphorus; one of the methods involve eliminating dissolved organic phosphorus (DOP) in treatment systems. The DOP in effluents and manure wastewater streams is commonly quantified without the identification of individual phosphorus species. Nevertheless, characterisation of the DOP is particularly important, because removal techniques, as well as soil sorption capacity and phosphorus transfer in the runoff to water bodies, differ for different DOP compounds. Particularly, phytic acid (PA), the main DOP compound in animal wastes, can strongly bind to soils making it unavailable for plant uptake. This work evaluates the application of a simple analytical procedure to the determination of the PA concentration in manure wastewater. The method does not require a prior acid digestion stage; in addition, sample colour removal, as well as the removal of potentially interfering compounds are not required. The results are in agreement with results obtained using 31P NMR. PA recoveries ranged between 87% and 97%, relative standard deviation was −1 and 0.55 mg·L−1 respectively.
- 2 March 2020
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 102 (5) , 1141-1151
A simple spectrophotometric method to determine phytic acid in poultry wastewater without acid digestion
Frequently, wastewater from treatment plants associated with animal husbandry, mainly animal feeding operations, are used to irrigate near agricultural lands based on nitrogen requirements. To avoid soil phosphorus accumulation owing to its long-term application, it is necessary to achieve lower levels of total phosphorus; one of the methods involve eliminating dissolved organic phosphorus (DOP) in treatment systems. The DOP in effluents and manure wastewater streams is commonly quantified without the identification of individual phosphorus species. Nevertheless, characterisation of the DOP is particularly important, because removal techniques, as well as soil sorption capacity and phosphorus transfer in the runoff to water bodies, differ for different DOP compounds. Particularly, phytic acid (PA), the main DOP compound in animal wastes, can strongly bind to soils making it unavailable for plant uptake. This work evaluates the application of a simple analytical procedure to the determination of the PA concentration in manure wastewater. The method does not require a prior acid digestion stage; in addition, sample colour removal, as well as the removal of potentially interfering compounds are not required. The results are in agreement with results obtained using 31P NMR. PA recoveries ranged between 87% and 97%, relative standard deviation was −1 and 0.55 mg·L−1 respectively.