Kriston Brooks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kriston Brooks has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Dionissios D. Papadias
Argonne National Laboratory, Lemont, IL 60439, USA
2 shared publications - Rajesh K. Ahluwalia
Argonne National Laboratory, Lemont, IL 60439, USA
2 shared publications - Tom Autrey
Pacific Northwest National Laboratory
2 shared publications - Ahmad Tbaileh
Pacific Northwest National Laboratory, Richland, WA 99354, USA
1 shared publication - Austin Acosta
Sandia National Laboratories California
1 shared publication - Brandon C. Wood
Lawrence Livermore National Laboratory
1 shared publication
Latest Publications
- Open Access
Hydrogen Carriers for Renewable Microgrid System Applications
Utility-scale energy storage can help improve grid reliability, reduce costs, and promote faster adoption of intermittent sources such as solar and wind. This paper analyzes the technical aspects and economics of standalone microgrids operating on intermittent power combined with hydrogen energy storage. It explores the feasibility of using dibenzyltoluene (DBT) as a liquid organic hydrogen carrier to absorb excess energy during periods of high supply and polymer electrolyte fuel cells to generate electrical energy during periods of low supply. A comparative analysis is conducted on three power demand scenarios (industrial, residential, and office), in conjunction with three alternative energy sources: solar, wind and wind–solar mix. A mixed system of solar and wind energy can maintain an annual average efficiency above 70%, except for residential power demand, which lowered the efficiency to 67%. A balanced combination of wind and solar power was the most cost-effective option. The current levelized cost of electricity (LCOE) for industrial power demand was estimated to 15 ¢/kWh, and it is projected to decrease to 9 ¢/kWh in the future. For residential power demand, the LCOE was 45% higher due to the demand profile. In comparison, battery storage is significantly more expensive than hydrogen storage, even with future cost projections, increasing the LCOE between 60 and 120 ¢/kWh.
Open AccessHydrogen Carriers for Renewable Microgrid System Applications
Utility-scale energy storage can help improve grid reliability, reduce costs, and promote faster adoption of intermittent sources such as solar and wind. This paper analyzes the technical aspects and economics of standalone microgrids operating on intermittent power combined with hydrogen energy storage. It explores the feasibility of using dibenzyltoluene (DBT) as a liquid organic hydrogen carrier to absorb excess energy during periods of high supply and polymer electrolyte fuel cells to generate electrical energy during periods of low supply. A comparative analysis is conducted on three power demand scenarios (industrial, residential, and office), in conjunction with three alternative energy sources: solar, wind and wind–solar mix. A mixed system of solar and wind energy can maintain an annual average efficiency above 70%, except for residential power demand, which lowered the efficiency to 67%. A balanced combination of wind and solar power was the most cost-effective option. The current levelized cost of electricity (LCOE) for industrial power demand was estimated to 15 ¢/kWh, and it is projected to decrease to 9 ¢/kWh in the future. For residential power demand, the LCOE was 45% higher due to the demand profile. In comparison, battery storage is significantly more expensive than hydrogen storage, even with future cost projections, increasing the LCOE between 60 and 120 ¢/kWh.
- Open Access
- 22 July 2024
- Published by American Chemical Society (ACS) in ChemRxiv
A Bulk vs. Nanoscale Hydrogen Storage Paradox Revealed by Material-System Co- Design
Metal hydrides are serious contenders for materials-based hydrogen storage to overcome constraints associated with compressed or liquefied H2. Their ultimate performance is usually evaluated using intrinsic material properties without considering a systems design perspective. An illustrative case with startling implications is (LiNH2+2LiH). Using models that simulate the storage system and associated fuel cell of a light-duty vehicle (LDV), we compared performance of the bulk hydrides with a nanoscaled version in porous carbon, (LiNH2+2LiH)@(6-nm PC). Using experimental material properties, the simulations show that (LiNH2+2LiH)@(6-nm PC) counterintuitively has higher usable gravimetric and volumetric capacities than the bulk counterpart on a system basis despite having lower capacities on a materials-only basis. Nanoscaling increases the thermal conductivity and lowers the desorption enthalpy, which consequently increases heat management efficiency. In a simulated drive cycle for fuel cell- powered LDV, the fuel cell is inoperable using bulk (LiNH2+2LiH) as the storage material but completes the drive cycle using the nanoscale material. These results challenge the notion that nanoscaling incurs mass and volume penalties. Instead, the synergistic nanoporous host-hydride interaction can favorably modulate chemical and heat transfer properties. Moreover, a co-design approach considering application- specific tradeoffs is essential to accurately assess a material’s potential for real-world hydrogen storage.
- 22 July 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA Bulk vs. Nanoscale Hydrogen Storage Paradox Revealed by Material-System Co- Design
Metal hydrides are serious contenders for materials-based hydrogen storage to overcome constraints associated with compressed or liquefied H2. Their ultimate performance is usually evaluated using intrinsic material properties without considering a systems design perspective. An illustrative case with startling implications is (LiNH2+2LiH). Using models that simulate the storage system and associated fuel cell of a light-duty vehicle (LDV), we compared performance of the bulk hydrides with a nanoscaled version in porous carbon, (LiNH2+2LiH)@(6-nm PC). Using experimental material properties, the simulations show that (LiNH2+2LiH)@(6-nm PC) counterintuitively has higher usable gravimetric and volumetric capacities than the bulk counterpart on a system basis despite having lower capacities on a materials-only basis. Nanoscaling increases the thermal conductivity and lowers the desorption enthalpy, which consequently increases heat management efficiency. In a simulated drive cycle for fuel cell- powered LDV, the fuel cell is inoperable using bulk (LiNH2+2LiH) as the storage material but completes the drive cycle using the nanoscale material. These results challenge the notion that nanoscaling incurs mass and volume penalties. Instead, the synergistic nanoporous host-hydride interaction can favorably modulate chemical and heat transfer properties. Moreover, a co-design approach considering application- specific tradeoffs is essential to accurately assess a material’s potential for real-world hydrogen storage.
- Open Access
- 22 November 2023
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 146 (1) , 1-51
Methods for Estimating Hydrogen Fuel Tank Characteristics
The pressure vessels needed to store hydrogen for next-generation hydrogen fuel cell vehicles are expected to be a substantial portion of the total system mass, volume, and cost. Gravimetric capacity, volumetric capacity, and cost per kilogram of usable hydrogen are key performance metrics that the U.S. Department of Energy (DOE) uses to determine the viability of hydrogen fuel cell systems. Research and development related to hydrogen storage systems covers a wide range of potential operating conditions, from cryogenic temperatures to high temperatures (above ambient) and low pressure to high pressure. Researchers at PNNL have developed methods for estimating these key pressure vessel characteristics to support on-board hydrogen storage system design and performance evaluation and to support decision-making about DOE hydrogen storage system research investments. This article describes the pressure tank estimation methodology that has been used as a stand-alone calculation and has been incorporated into larger system evaluation tools. The methodology estimates the geometry, mass, and material cost of type I, type III, and type IV pressure vessels based on operating pressure and material strength at the system's operating temperature, using classical thin-wall and thick-wall pressure vessel stress calculations. The geometry, mass, and material cost requirements of the pressure vessel have significant impacts on the total system performance. For example, hydrogen storage materials that can separately achieve a very high hydrogen density can be deemed impractical for use in fuel cell vehicle hydrogen storage systems because the pressure tank containing them is too large, heavy, or expensive. This article describes the design philosophy and analytical process of the tank characteristic estimation methodology, which has been implemented in spreadsheet calculation tools and system-level analysis tools used by DOE researchers. Each of the three tank types (type I, type III, and type IV) uses a different analysis methodology with some common elements. This article also provides examples of implementing the methodology to perform parametric studies of all three pressure vessel types. The goal of this article is to present the methodology in sufficient detail so it can be implemented in other hydrogen fuel cell vehicle design and analysis tools.
- 22 November 2023
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 146 (1) , 1-51
Open AccessMethods for Estimating Hydrogen Fuel Tank Characteristics
The pressure vessels needed to store hydrogen for next-generation hydrogen fuel cell vehicles are expected to be a substantial portion of the total system mass, volume, and cost. Gravimetric capacity, volumetric capacity, and cost per kilogram of usable hydrogen are key performance metrics that the U.S. Department of Energy (DOE) uses to determine the viability of hydrogen fuel cell systems. Research and development related to hydrogen storage systems covers a wide range of potential operating conditions, from cryogenic temperatures to high temperatures (above ambient) and low pressure to high pressure. Researchers at PNNL have developed methods for estimating these key pressure vessel characteristics to support on-board hydrogen storage system design and performance evaluation and to support decision-making about DOE hydrogen storage system research investments. This article describes the pressure tank estimation methodology that has been used as a stand-alone calculation and has been incorporated into larger system evaluation tools. The methodology estimates the geometry, mass, and material cost of type I, type III, and type IV pressure vessels based on operating pressure and material strength at the system's operating temperature, using classical thin-wall and thick-wall pressure vessel stress calculations. The geometry, mass, and material cost requirements of the pressure vessel have significant impacts on the total system performance. For example, hydrogen storage materials that can separately achieve a very high hydrogen density can be deemed impractical for use in fuel cell vehicle hydrogen storage systems because the pressure tank containing them is too large, heavy, or expensive. This article describes the design philosophy and analytical process of the tank characteristic estimation methodology, which has been implemented in spreadsheet calculation tools and system-level analysis tools used by DOE researchers. Each of the three tank types (type I, type III, and type IV) uses a different analysis methodology with some common elements. This article also provides examples of implementing the methodology to perform parametric studies of all three pressure vessel types. The goal of this article is to present the methodology in sufficient detail so it can be implemented in other hydrogen fuel cell vehicle design and analysis tools.
- Open Access
- 27 March 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Green steel: design and cost analysis of hydrogen-based direct iron reduction
Hydrogen-based direct reduced iron (H2-DRI) is an alternative pathway for low-carbon steel production. Yet, the lack of established process and business models defining “green steel” make it difficult to understand what the respective H2 price has to be in order to be competitive with commercial state-of-the-art natural gas DRI. Given the importance of establishing break-even H2 prices and CO2 emission reduction potentials of H2-DRI, this study conducted techno-economic analyses of several design and operation scenarios for DRI systems. Results show that renewable H2 use in integrated DRI steel mills for both heating and the reduction of iron ore can reduce direct CO2 emissions by as much as 85%, but would require an H2 procurement cost of $1.63 per kg H2 or less. When using H2 only for iron ore reduction, economic viability is reached at an H2 procurement cost of $1.70 per kg, while achieving a CO2 emission reduction of 76% at the plant site. System design optimization strategies around excess H2 ratios in the DRI top gas and the H2 recycle pressurization can further improve performance and economics. Low H2 excess ratios are particularly attractive as they reduce pre-heating energy requirements and offer integration opportunities with static recycle ejectors if H2 is supplied at sufficiently high pressure. The potential of utilizing the EAF off-gas is shown to be much more synergistic with H2 DRI than NG DRI and can increase the break-even H2 procurement cost by up to 7¢ per kg H2. Such findings are critical for setting technical performance criteria for H2 supply and storage in the iron and steel sector.
- 27 March 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessGreen steel: design and cost analysis of hydrogen-based direct iron reduction
Hydrogen-based direct reduced iron (H2-DRI) is an alternative pathway for low-carbon steel production. Yet, the lack of established process and business models defining “green steel” make it difficult to understand what the respective H2 price has to be in order to be competitive with commercial state-of-the-art natural gas DRI. Given the importance of establishing break-even H2 prices and CO2 emission reduction potentials of H2-DRI, this study conducted techno-economic analyses of several design and operation scenarios for DRI systems. Results show that renewable H2 use in integrated DRI steel mills for both heating and the reduction of iron ore can reduce direct CO2 emissions by as much as 85%, but would require an H2 procurement cost of $1.63 per kg H2 or less. When using H2 only for iron ore reduction, economic viability is reached at an H2 procurement cost of $1.70 per kg, while achieving a CO2 emission reduction of 76% at the plant site. System design optimization strategies around excess H2 ratios in the DRI top gas and the H2 recycle pressurization can further improve performance and economics. Low H2 excess ratios are particularly attractive as they reduce pre-heating energy requirements and offer integration opportunities with static recycle ejectors if H2 is supplied at sufficiently high pressure. The potential of utilizing the EAF off-gas is shown to be much more synergistic with H2 DRI than NG DRI and can increase the break-even H2 procurement cost by up to 7¢ per kg H2. Such findings are critical for setting technical performance criteria for H2 supply and storage in the iron and steel sector.
- Open Access
- 23 November 2020
- Published by LIDSEN Publishing Inc in Journal of Energy and Power Technology
- Vol. 02 (04) , 1-21
Research Requirements to Move the Bar forward Using Aqueous Formate Salts as H2 Carriers for Energy Storage Applications
In this perspective on hydrogen carriers, we focus on the needs for the development of robust active catalysts for the release of H2 from aqueous formate solutions, which are non-flammable, non-toxic, thermally stable, and readily available at large scales at reasonable cost. Formate salts can be stockpiled in the solid state or dissolved in water for long term storage and transport using existing infrastructure. Furthermore, formate salts are readily regenerated at moderate pressures using the same catalyst as for the H2 release. There have been several studies focused on increasing the activity of catalysts to release H2 at moderate temperatures, i.e., < 80 °C, below the operating temperature of a proton exchange membrane (PEM) fuel cell. One significant challenge to enable the use of aqueous formate salts as hydrogen carriers is the deactivation of the catalyst under operating conditions. In this work we provide a review of the most efficient heterogeneous catalysts that have been described in the literature, their proposed modes of deactivation, and the strategies reported to reactivate them. We discuss potential pathways that may lead to deactivation and strategies to mitigate it in a variety of H2 carrier applications. We also provide an example of a potential use case employing formate salts solutions using a fixed bed reactor for seasonal storage of energy for a microgrid application.
- 23 November 2020
- Published by LIDSEN Publishing Inc in Journal of Energy and Power Technology
- Vol. 02 (04) , 1-21
Open AccessResearch Requirements to Move the Bar forward Using Aqueous Formate Salts as H2 Carriers for Energy Storage Applications
In this perspective on hydrogen carriers, we focus on the needs for the development of robust active catalysts for the release of H2 from aqueous formate solutions, which are non-flammable, non-toxic, thermally stable, and readily available at large scales at reasonable cost. Formate salts can be stockpiled in the solid state or dissolved in water for long term storage and transport using existing infrastructure. Furthermore, formate salts are readily regenerated at moderate pressures using the same catalyst as for the H2 release. There have been several studies focused on increasing the activity of catalysts to release H2 at moderate temperatures, i.e., < 80 °C, below the operating temperature of a proton exchange membrane (PEM) fuel cell. One significant challenge to enable the use of aqueous formate salts as hydrogen carriers is the deactivation of the catalyst under operating conditions. In this work we provide a review of the most efficient heterogeneous catalysts that have been described in the literature, their proposed modes of deactivation, and the strategies reported to reactivate them. We discuss potential pathways that may lead to deactivation and strategies to mitigate it in a variety of H2 carrier applications. We also provide an example of a potential use case employing formate salts solutions using a fixed bed reactor for seasonal storage of energy for a microgrid application.