Sofia Taddei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sofia Taddei has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Roberto Piro
Pulmonology Unit, Azienda Unità Sanitaria Locale—IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
8 shared publications - Eleonora Casalini
Pulmonology Unit, Azienda Unità Sanitaria Locale—IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
7 shared publications - Matteo Fontana
Pulmonology Unit, Azienda Unità Sanitaria Locale—IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
7 shared publications - Nicola Facciolongo
Pulmonology Unit, Azienda Unità Sanitaria Locale—IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
5 shared publications - Bianca Beghè
Department of Medical and Surgical Sciences, Section of Respiratory Diseases, University of Modena and Reggio Emilia
3 shared publications - Nicola Facciolongo
Pulmonology Unit, Azienda Unità Sanitaria Locale - IRCCS di Reggio Emilia, Reggio Emilia, Italy
3 shared publications
Latest Publications
- Open Access
- 25 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (11) , 4084
Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration (EBUS-TBNA) in Moderate Sedation in Patients Aged 80 Years and Older
Background/Objectives: The utility and safety of EBUS-TBNA in the general population are well-documented in the scientific literature, but data on elderly patients, particularly those over 80 years old, are limited. Methods: We retrospectively investigated patients aged 80 and over who underwent EBUS-TBNA under moderate sedation, without anesthesiologic assistance, over a period of seven years at a single Italian hospital. The primary outcome was the safety of the procedure assessed by evaluating the complication rate occurring during the procedure and up to one week afterward. Secondary outcomes included the rate of procedures with successful sampling, the percentage of procedure repeated with anesthesiologic assistance, specimen adequacy, overall diagnostic yield, type of diagnosis, malignancy rate and the percentage of patients who underwent active treatment after obtaining an oncological diagnosis. Results: A total of 141 patients were enrolled in the study; the mean age was 82.6 ± 2.2 years. The incidence of complications was 11.3% (16/141); most adverse events were mild (9.9% 14/141). Two patients (1.4%) experienced major complications requiring hospitalization. Regarding the secondary endpoints, sampling was successfully performed in 99.3% of cases (140/141); in one case, it was necessary to repeat the procedure with anesthesiologic assistance (0.7% 1/141). Specimens were adequate in 96.4% of cases (135/140); the overall diagnostic rate was 85.7% (120/140); the malignancy rate was 52.9% (74/140) and among these, 78.4% (58/74) were treated. Conclusions: EBUS-TBNA performed under moderate sedation is a safe and diagnostically effective procedure in patients older than 80 years of age, supporting its use in this growing population.
- 25 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (11) , 4084
Open AccessEndobronchial Ultrasound-Guided Transbronchial Needle Aspiration (EBUS-TBNA) in Moderate Sedation in Patients Aged 80 Years and Older
Background/Objectives: The utility and safety of EBUS-TBNA in the general population are well-documented in the scientific literature, but data on elderly patients, particularly those over 80 years old, are limited. Methods: We retrospectively investigated patients aged 80 and over who underwent EBUS-TBNA under moderate sedation, without anesthesiologic assistance, over a period of seven years at a single Italian hospital. The primary outcome was the safety of the procedure assessed by evaluating the complication rate occurring during the procedure and up to one week afterward. Secondary outcomes included the rate of procedures with successful sampling, the percentage of procedure repeated with anesthesiologic assistance, specimen adequacy, overall diagnostic yield, type of diagnosis, malignancy rate and the percentage of patients who underwent active treatment after obtaining an oncological diagnosis. Results: A total of 141 patients were enrolled in the study; the mean age was 82.6 ± 2.2 years. The incidence of complications was 11.3% (16/141); most adverse events were mild (9.9% 14/141). Two patients (1.4%) experienced major complications requiring hospitalization. Regarding the secondary endpoints, sampling was successfully performed in 99.3% of cases (140/141); in one case, it was necessary to repeat the procedure with anesthesiologic assistance (0.7% 1/141). Specimens were adequate in 96.4% of cases (135/140); the overall diagnostic rate was 85.7% (120/140); the malignancy rate was 52.9% (74/140) and among these, 78.4% (58/74) were treated. Conclusions: EBUS-TBNA performed under moderate sedation is a safe and diagnostically effective procedure in patients older than 80 years of age, supporting its use in this growing population.
- Open Access
- 13 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (8) , 1405
Safety and Diagnostic Accuracy of the Transnasal Approach for Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration (EBUS-TBNA)
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a safe and accurate diagnostic procedure used for investigating mediastinal pathologies. It is usually performed using an oral approach. The nasal route has been proposed but not extensively investigated. With the aim to report the use of linear EBUS through the nasal route and compare its accuracy and safety with the oral one, we conducted a retrospective analysis of the subjects who underwent an EBUS-TBNA procedure at our center. From January 2020 to December 2021, 464 subjects underwent an EBUS-TBNA, and in 417 patients, EBUS was performed through the nose or mouth. Nasal insertion of the EBUS bronchoscope was performed in 58.5% of the patients. No difference between the two insertion routes was observed in terms of location or number of stations sampled per subject. Procedure complications were mild and similar between the two groups (10.2% for the nasal group vs. 9.8% for the oral group). Minor epistaxis occurred in five subjects in the nasal group. Comparing the two groups, the rates of adequate specimens were similar (95.1% vs. 94.8%), as were the proportions of diagnostic specimens (84% vs. 82%). In conclusion, the nasal route for EBUS-TBNA is a valid alternative to the oral one.
- 13 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (8) , 1405
Open AccessSafety and Diagnostic Accuracy of the Transnasal Approach for Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration (EBUS-TBNA)
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a safe and accurate diagnostic procedure used for investigating mediastinal pathologies. It is usually performed using an oral approach. The nasal route has been proposed but not extensively investigated. With the aim to report the use of linear EBUS through the nasal route and compare its accuracy and safety with the oral one, we conducted a retrospective analysis of the subjects who underwent an EBUS-TBNA procedure at our center. From January 2020 to December 2021, 464 subjects underwent an EBUS-TBNA, and in 417 patients, EBUS was performed through the nose or mouth. Nasal insertion of the EBUS bronchoscope was performed in 58.5% of the patients. No difference between the two insertion routes was observed in terms of location or number of stations sampled per subject. Procedure complications were mild and similar between the two groups (10.2% for the nasal group vs. 9.8% for the oral group). Minor epistaxis occurred in five subjects in the nasal group. Comparing the two groups, the rates of adequate specimens were similar (95.1% vs. 94.8%), as were the proportions of diagnostic specimens (84% vs. 82%). In conclusion, the nasal route for EBUS-TBNA is a valid alternative to the oral one.
- Open Access
- 16 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2813
Diagnosis of Organizing Pneumonia with an Ultrathin Bronchoscope and Cone-Beam CT: A Case Report
Organizing pneumonia (OP) is a pulmonary disease histopathologically characterized by plugs of loose connective tissue in distal airways. The clinical and radiological presentations are not specific and they usually require a biopsy confirmation. This paper presents the case of a patient with a pulmonary opacity sampled with a combined technique of ultrathin bronchoscopy and cone-beam CT. A 64-year-old female, a former smoker, was admitted to the hospital of Reggio Emilia (Italy) for exertional dyspnea and a dry cough without a fever. The history of the patient included primary Sjögren Syndrome interstitial lung disease (pSS-ILD) characterized by a non-specific interstitial pneumonia (NSIP) radiological pattern; this condition was successfully treated up to 18 months before the new admission. The CT scan showed the appearance of a right lower lobe pulmonary opacity of an uncertain origin that required a histological exam for the diagnosis. The lung lesion was difficult to reach with traditional bronchoscopy and a percutaneous approach was excluded. Thus, cone-beam CT, augmented fluoroscopy and ultrathin bronchoscopy were chosen to collect a tissue sample. The histopathological exam was suggestive of OP, a condition occurring in 4–11% of primary Sjögren Syndrome cases. This case showed that, in the correct clinical and radiological context, even biopsies taken with small forceps can lead to a diagnosis of OP. Moreover, it underlined that the combination of multiple advanced technologies in the same procedure can help to reach difficult target lesions, providing proper samples for a histological diagnosis.
- 16 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2813
Open AccessDiagnosis of Organizing Pneumonia with an Ultrathin Bronchoscope and Cone-Beam CT: A Case Report
Organizing pneumonia (OP) is a pulmonary disease histopathologically characterized by plugs of loose connective tissue in distal airways. The clinical and radiological presentations are not specific and they usually require a biopsy confirmation. This paper presents the case of a patient with a pulmonary opacity sampled with a combined technique of ultrathin bronchoscopy and cone-beam CT. A 64-year-old female, a former smoker, was admitted to the hospital of Reggio Emilia (Italy) for exertional dyspnea and a dry cough without a fever. The history of the patient included primary Sjögren Syndrome interstitial lung disease (pSS-ILD) characterized by a non-specific interstitial pneumonia (NSIP) radiological pattern; this condition was successfully treated up to 18 months before the new admission. The CT scan showed the appearance of a right lower lobe pulmonary opacity of an uncertain origin that required a histological exam for the diagnosis. The lung lesion was difficult to reach with traditional bronchoscopy and a percutaneous approach was excluded. Thus, cone-beam CT, augmented fluoroscopy and ultrathin bronchoscopy were chosen to collect a tissue sample. The histopathological exam was suggestive of OP, a condition occurring in 4–11% of primary Sjögren Syndrome cases. This case showed that, in the correct clinical and radiological context, even biopsies taken with small forceps can lead to a diagnosis of OP. Moreover, it underlined that the combination of multiple advanced technologies in the same procedure can help to reach difficult target lesions, providing proper samples for a histological diagnosis.
- Open Access
- 18 September 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (9) , 2254
Diagnosis and Pattern Identification of Intrathoracic Malignant Melanoma Metastasis: A Retrospective Single Center Analysis
The lung is a frequent site of secondary malignancies. Melanoma is a malignant tumor originating from melanocytes, that accounts for the majority of death related to skin cancers. In advanced stages, it can also present with intrathoracic metastasis, particularly in the lungs, but infrequent intrathoracic manifestations are possible. A retrospective analysis of the cases referred to the pulmonary endoscopy unit of the hospital of Reggio Emilia in the last 10 years (since December 2012) was carried out, discovering 17 cases of melanoma metastasis with thoracic localizations, either with or without a diagnosis of primary melanoma. Four repetitive patterns of clinical-radiological presentation have been identified and described through the same number of paradigmatic clinical cases: nodal involvement (35%), lung mass(es) (41%), diffuse pulmonary involvement (12%), and pleural involvement (12%). These different presentations imply the use of different diagnostic techniques, with an overall high diagnostic yield (87.5%). Finally, a brief analysis of survival based on the pattern of presentation has been performed, finding no statistically significant differences between the four groups at metastasis diagnosis (p-value = 0.06, median survival of respectively 54, 8, 9, and 26 months from metastasis diagnosis), while there is a significant difference considering patients with lung involvement versus nodal/pleural involvement (p = 0.01).
- 18 September 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (9) , 2254
Open AccessDiagnosis and Pattern Identification of Intrathoracic Malignant Melanoma Metastasis: A Retrospective Single Center Analysis
The lung is a frequent site of secondary malignancies. Melanoma is a malignant tumor originating from melanocytes, that accounts for the majority of death related to skin cancers. In advanced stages, it can also present with intrathoracic metastasis, particularly in the lungs, but infrequent intrathoracic manifestations are possible. A retrospective analysis of the cases referred to the pulmonary endoscopy unit of the hospital of Reggio Emilia in the last 10 years (since December 2012) was carried out, discovering 17 cases of melanoma metastasis with thoracic localizations, either with or without a diagnosis of primary melanoma. Four repetitive patterns of clinical-radiological presentation have been identified and described through the same number of paradigmatic clinical cases: nodal involvement (35%), lung mass(es) (41%), diffuse pulmonary involvement (12%), and pleural involvement (12%). These different presentations imply the use of different diagnostic techniques, with an overall high diagnostic yield (87.5%). Finally, a brief analysis of survival based on the pattern of presentation has been performed, finding no statistically significant differences between the four groups at metastasis diagnosis (p-value = 0.06, median survival of respectively 54, 8, 9, and 26 months from metastasis diagnosis), while there is a significant difference considering patients with lung involvement versus nodal/pleural involvement (p = 0.01).
- Open Access
- 20 October 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-6
Cone beam CT augmented fluoroscopy allows safe and efficient diagnosis of a difficult lung nodule
Background: Detection of small peripheral lung nodules is constantly increasing with the development of low dose computed tomography lung cancer screening programs. A tissue diagnosis is often required to confirm malignity, with endobronchial biopsies being associated with a lower pneumothorax rate than percutaneous approaches. Endoscopic diagnosis of peripheral small size lung nodules is however often challenging using traditional bronchoscopy and endobronchial ultrasound alone. New virtual bronchoscopic navigation techniques such as electromagnetic navigational bronchoscopy (ENB) have developed to improve peripheral navigation, with diagnostic yield however remaining in the 30–50% range for small lesions. Recent studies have shown the benefits of combining Cone beam computed tomography (CBCT) with ENB to improve diagnostic yield to up to 83%. The use of ENB however remains limited by disposable cost, bronchus sign dependency and inaccuracies due to CT to body divergence. Case presentation: This case report highlights the feasibility and usefulness of CBCT-guided bronchoscopy for the sampling of lung nodules difficult to reach through traditional bronchoscopy because of nodule size and peripheral position. Procedure was scheduled in a mobile robotic hybrid operating room with patient under general anaesthesia. CBCT acquisition was performed to localize the target lesion and plan the best path to reach it into bronchial tree. A dedicated software was used to segment the lesion and the bronchial path which 3D outlines were automatically fused in real time on the fluoroscopic images to augment live guidance. Navigation to the lesion was guided with bronchoscopy and augmented fluoroscopy alone. Before the sampling, CBCT imaging was repeated to confirm the proper position of the instrument into the lesion. Four transbronchial needle aspirations (TBNA) were performed and the tissue analysis showed a primary lung adenocarcinoma. Conclusions: CBCT and augmented fluoroscopy technique is a safe and effective and has potential to improve early stage peripheral lesions endobronchial diagnostic yield without ENB. Additional studies are warranted to confirm its safety, efficacy and technical benefits, both for diagnosis of oncological and non-oncological disease and for endobronchial treatment of inoperable patients.
- 20 October 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-6
Open AccessCone beam CT augmented fluoroscopy allows safe and efficient diagnosis of a difficult lung nodule
Background: Detection of small peripheral lung nodules is constantly increasing with the development of low dose computed tomography lung cancer screening programs. A tissue diagnosis is often required to confirm malignity, with endobronchial biopsies being associated with a lower pneumothorax rate than percutaneous approaches. Endoscopic diagnosis of peripheral small size lung nodules is however often challenging using traditional bronchoscopy and endobronchial ultrasound alone. New virtual bronchoscopic navigation techniques such as electromagnetic navigational bronchoscopy (ENB) have developed to improve peripheral navigation, with diagnostic yield however remaining in the 30–50% range for small lesions. Recent studies have shown the benefits of combining Cone beam computed tomography (CBCT) with ENB to improve diagnostic yield to up to 83%. The use of ENB however remains limited by disposable cost, bronchus sign dependency and inaccuracies due to CT to body divergence. Case presentation: This case report highlights the feasibility and usefulness of CBCT-guided bronchoscopy for the sampling of lung nodules difficult to reach through traditional bronchoscopy because of nodule size and peripheral position. Procedure was scheduled in a mobile robotic hybrid operating room with patient under general anaesthesia. CBCT acquisition was performed to localize the target lesion and plan the best path to reach it into bronchial tree. A dedicated software was used to segment the lesion and the bronchial path which 3D outlines were automatically fused in real time on the fluoroscopic images to augment live guidance. Navigation to the lesion was guided with bronchoscopy and augmented fluoroscopy alone. Before the sampling, CBCT imaging was repeated to confirm the proper position of the instrument into the lesion. Four transbronchial needle aspirations (TBNA) were performed and the tissue analysis showed a primary lung adenocarcinoma. Conclusions: CBCT and augmented fluoroscopy technique is a safe and effective and has potential to improve early stage peripheral lesions endobronchial diagnostic yield without ENB. Additional studies are warranted to confirm its safety, efficacy and technical benefits, both for diagnosis of oncological and non-oncological disease and for endobronchial treatment of inoperable patients.
- Open Access
- 23 August 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-3
Lung "holes" after cryobiopsy: a case report
Background: Transbronchial lung cryobiopsy is a safe technique increasingly used in the study of lung diseases. Until now, only a case of pneumatocele was described but this interesting condition is probably underestimated because CT scan is routinely not performed after transbronchial lung cryobiopsies. Case presentation: We report a case of a woman presenting two pneumatoceles after lung cryobiopsies performed for the study of an interstitial lung disease. The finding was obtained with a CT scan performed because of the appearance of hemoptysis, four days after the biopsies. Conclusions: Small cavitations could develop after cryobiopsies in the absence of an active infection. Studies that prospectively perform CT scan of the chest in patients who have undergone these samplings could be useful to know the incidence of iatrogenic lesions.
- 23 August 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-3
Open AccessLung "holes" after cryobiopsy: a case report
Background: Transbronchial lung cryobiopsy is a safe technique increasingly used in the study of lung diseases. Until now, only a case of pneumatocele was described but this interesting condition is probably underestimated because CT scan is routinely not performed after transbronchial lung cryobiopsies. Case presentation: We report a case of a woman presenting two pneumatoceles after lung cryobiopsies performed for the study of an interstitial lung disease. The finding was obtained with a CT scan performed because of the appearance of hemoptysis, four days after the biopsies. Conclusions: Small cavitations could develop after cryobiopsies in the absence of an active infection. Studies that prospectively perform CT scan of the chest in patients who have undergone these samplings could be useful to know the incidence of iatrogenic lesions.
- Open Access
- 1 June 2021
- Published by Taylor & Francis in Journal of Asthma and Allergy
- Vol. ume 14, 753-754
Profile of Anti-IL-5 mAb Mepolizumab in the Treatment of Severe Refractory Asthma and Hypereosinophilic Diseases [Corrigendum]
Corrigendum for the article Profile of anti-IL-5 mAb mepolizumab in the treatment of severe refractory asthma and hypereosinophilic diseases
- 1 June 2021
- Published by Taylor & Francis in Journal of Asthma and Allergy
- Vol. ume 14, 753-754
Open AccessProfile of Anti-IL-5 mAb Mepolizumab in the Treatment of Severe Refractory Asthma and Hypereosinophilic Diseases [Corrigendum]
Corrigendum for the article Profile of anti-IL-5 mAb mepolizumab in the treatment of severe refractory asthma and hypereosinophilic diseases
- Open Access
- 3 February 2021
- Published by Wiley in Thoracic Cancer
- Vol. 12 (6) , 981-984
Pleural mesothelioma: When echo‐endoscopy (EUS‐B‐FNA) leads to diagnosis in a minimally invasive way
Malignant pleural mesothelioma (MPM) is an asbestos‐related and locally invasive tumor with poor prognosis. The acquisition of histological material is mandatory in order to establish a diagnosis. In this situation, the sampling of tissue is generally performed via a thoracoscopic pleural biopsy, either medically or surgically. The use of endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) or transesophageal fine needle aspiration with an EBUS scope (EUS‐B‐FNA) of pleural lesions have only rarely been reported due to the theoretical limitations of tissue acquisition in such cases. We herein report a rare case of MPM successfully diagnosed via EUS‐B‐FNA in a 49‐year‐old woman with an unusual presentation characterized by solid thickening in the right mediastinal pleura.
- 3 February 2021
- Published by Wiley in Thoracic Cancer
- Vol. 12 (6) , 981-984
Open AccessPleural mesothelioma: When echo‐endoscopy (EUS‐B‐FNA) leads to diagnosis in a minimally invasive way
Malignant pleural mesothelioma (MPM) is an asbestos‐related and locally invasive tumor with poor prognosis. The acquisition of histological material is mandatory in order to establish a diagnosis. In this situation, the sampling of tissue is generally performed via a thoracoscopic pleural biopsy, either medically or surgically. The use of endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) or transesophageal fine needle aspiration with an EBUS scope (EUS‐B‐FNA) of pleural lesions have only rarely been reported due to the theoretical limitations of tissue acquisition in such cases. We herein report a rare case of MPM successfully diagnosed via EUS‐B‐FNA in a 49‐year‐old woman with an unusual presentation characterized by solid thickening in the right mediastinal pleura.