Luca Barion
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luca Barion has a total of 411 co-authors. Here are the top co-authors by number of shared publications:
- Marco Contalbrigo
University of Ferrara and Istituto Nazionale di Fisica Nucleare
10 shared publications - S. Vallarino
INFN Sezione di Genova, Genova
10 shared publications - A. De Caro
Dipartimento di Fisica ‘E.R. Caianiello’ dell’Università and Gruppo Collegato INFN
9 shared publications - B Rajesh Achari
INFN Sezione di Bologna, Bologna
9 shared publications C. Baldanza
9 shared publications- Cristina Ripoli
Dipartimento di Fisica ‘E.R. Caianiello’ dell’Università and Gruppo Collegato INFN
9 shared publications
Latest Publications
- Open Access
- 16 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (24) , 241801
First Experimental Limit on the Permanent Electric Dipole Moment of the Deuteron
Permanent electric dipole moments (EDMs) provide a sensitive probe of physics beyond the standard model and are directly linked to additional sources of C P violation that could explain the matter-antimatter asymmetry of the Universe. EDM measurements of charged particles in storage rings rely on detecting a small tilt of the invariant spin axis with respect to the ring plane. In this Letter, we present the experimental determination of the invariant spin axis of an ensemble of deuterons in the Cooler Synchrotron (COSY), a conventional magnetic storage ring, using a combination of a radio-frequency Wien filter, a superconducting Siberian snake, and an electron-cooler solenoid. The measurements reveal tilts of a few milliradians, which are dominated by systematic effects. From the observed tilts, we derive the first experimental limit on the deuteron EDM, | d d | < 2.5 × 10 − 17 e cm ( 95 % C . L . ) . This result demonstrates the feasibility of using storage rings to search for EDMs of charged stable hadrons and provides a foundation for future dedicated facilities.
- 16 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (24) , 241801
Open AccessFirst Experimental Limit on the Permanent Electric Dipole Moment of the Deuteron
Permanent electric dipole moments (EDMs) provide a sensitive probe of physics beyond the standard model and are directly linked to additional sources of C P violation that could explain the matter-antimatter asymmetry of the Universe. EDM measurements of charged particles in storage rings rely on detecting a small tilt of the invariant spin axis with respect to the ring plane. In this Letter, we present the experimental determination of the invariant spin axis of an ensemble of deuterons in the Cooler Synchrotron (COSY), a conventional magnetic storage ring, using a combination of a radio-frequency Wien filter, a superconducting Siberian snake, and an electron-cooler solenoid. The measurements reveal tilts of a few milliradians, which are dominated by systematic effects. From the observed tilts, we derive the first experimental limit on the deuteron EDM, | d d | < 2.5 × 10 − 17 e cm ( 95 % C . L . ) . This result demonstrates the feasibility of using storage rings to search for EDMs of charged stable hadrons and provides a foundation for future dedicated facilities.
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , C06003
ALCOR, a mixed-signal ASIC for SiPM readout of the ePIC-dRICH detector at the EIC
ALCOR is a mixed-signal ASIC developed for the readout of silicon photomultiplier (SiPM) sensors in the ePIC dual-radiator RICH (dRICH) detector at the future Electron-Ion Collider (EIC). The current design integrates 32 channels in an 8×4 pixel array, providing high-precision timestamping with single-photon sensitivity, data-push architecture and fully digital output. Each channel features an analog front-end compatible with both signal polarities, comprising a low-impedance input stage, four selectable gain settings, and two leading-edge discriminators with independent 6-bit DAC thresholds. Precise timing is achieved by quad-buffered, low-power TDCs with analog interpolation and 20–40 ps time bin. Additional operating modes, including time-over-threshold and slew-rate, provide indirect amplitude measurements and effective time-walk correction. The power consumption of the full channel is 12 mW with default settings. Fabricated in 110 nm CMOS technology, ALCOR has been thoroughly validated in standalone operation and coupled with multiple SiPM models. Laboratory tests using single-photon laser pulses and HPK S13360 devices demonstrated an overall time resolution below 150 ps RMS. Two beam test campaigns at CERN-PS in 2023 and 2024, employing a dRICH prototype instrumented with 2048 3×3 mm 2 SiPMs read out by ALCOR, confirmed its suitability for ring-imaging and particle-identification. A new version of the ASIC, named ALCOR-64, was designed and submitted for fabrication in April 2025. This version doubles the channel count to 64, integrates the ASIC in a ball grid array package and addresses specific EIC-driven requirements, including a programmable-width hardware shutter to inhibit events digitization and thus suppress the SiPM out-of-time DCR-induced background.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , C06003
Open AccessALCOR, a mixed-signal ASIC for SiPM readout of the ePIC-dRICH detector at the EIC
ALCOR is a mixed-signal ASIC developed for the readout of silicon photomultiplier (SiPM) sensors in the ePIC dual-radiator RICH (dRICH) detector at the future Electron-Ion Collider (EIC). The current design integrates 32 channels in an 8×4 pixel array, providing high-precision timestamping with single-photon sensitivity, data-push architecture and fully digital output. Each channel features an analog front-end compatible with both signal polarities, comprising a low-impedance input stage, four selectable gain settings, and two leading-edge discriminators with independent 6-bit DAC thresholds. Precise timing is achieved by quad-buffered, low-power TDCs with analog interpolation and 20–40 ps time bin. Additional operating modes, including time-over-threshold and slew-rate, provide indirect amplitude measurements and effective time-walk correction. The power consumption of the full channel is 12 mW with default settings. Fabricated in 110 nm CMOS technology, ALCOR has been thoroughly validated in standalone operation and coupled with multiple SiPM models. Laboratory tests using single-photon laser pulses and HPK S13360 devices demonstrated an overall time resolution below 150 ps RMS. Two beam test campaigns at CERN-PS in 2023 and 2024, employing a dRICH prototype instrumented with 2048 3×3 mm 2 SiPMs read out by ALCOR, confirmed its suitability for ring-imaging and particle-identification. A new version of the ASIC, named ALCOR-64, was designed and submitted for fabrication in April 2025. This version doubles the channel count to 64, integrates the ASIC in a ball grid array package and addresses specific EIC-driven requirements, including a programmable-width hardware shutter to inhibit events digitization and thus suppress the SiPM out-of-time DCR-induced background.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04039
Radiation tolerance tests on key components of the ePIC-dRICH readout card
The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5 × 5 × 12 cm 3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04039
Open AccessRadiation tolerance tests on key components of the ePIC-dRICH readout card
The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5 × 5 × 12 cm 3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.
- 18 March 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1088
The CLAS12 RICH detector
- 18 March 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1088
The CLAS12 RICH detector
- Open Access
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01031
The SiPM readout plane for the ePIC-dRICH photo-detector at the EIC: overview and beam test results
The dual-radiator (dRICH) detector of the ePIC experiment at the future Electron-Ion Collider (EIC) will make use of SiPM sensors for the detection of the emitted Cherenkov light. The photo-detector will cover ∼3 m 2 with 3×3 mm 2 pixels, for a total of more than 300000 readout channels, and will be the first application of SiPMs for single-photon detection in a collider experiment. SiPMs are chosen for their low cost and high photon detection efficiency, which remains unaffected even in the presence of a high magnetic field. However, since they are not radiation-hard, careful attention is required to preserve their single-photon counting capabilities and to keep the dark count rate (DCR) under control throughout the years of operation of the ePIC experiment. DCR control can be achieved by operating SiPMs at low temperatures and by recovering radiation damage through high-temperature annealing cycles. We present an overview of the ePIC-dRICH photo-detector system. Special focus is given to development and beam test results of a large-area prototype SiPM readout plane consisting of a total of up to 2048 3×3 mm 2 sensors. The photo-detector prototype is modular and based on a novel EIC-driven photo-detection unit (PDU) developed by INFN, which integrates 256 SiPM pixel sensors, cooling and TDC electronics in a volume of ∼5×5×14 cm 3 . The prototype has been successfully tested with particle beams at CERN-PS in October 2023 and in May 2024. Results on ring images reconstructed, beam momentum scan and particle identification using the dual radiator configuration are presented. In addition, studies on radiation-induced defects using emission microscopy, and on annealing cycles used to recover radiation damage, are shown.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01031
Open AccessThe SiPM readout plane for the ePIC-dRICH photo-detector at the EIC: overview and beam test results
The dual-radiator (dRICH) detector of the ePIC experiment at the future Electron-Ion Collider (EIC) will make use of SiPM sensors for the detection of the emitted Cherenkov light. The photo-detector will cover ∼3 m 2 with 3×3 mm 2 pixels, for a total of more than 300000 readout channels, and will be the first application of SiPMs for single-photon detection in a collider experiment. SiPMs are chosen for their low cost and high photon detection efficiency, which remains unaffected even in the presence of a high magnetic field. However, since they are not radiation-hard, careful attention is required to preserve their single-photon counting capabilities and to keep the dark count rate (DCR) under control throughout the years of operation of the ePIC experiment. DCR control can be achieved by operating SiPMs at low temperatures and by recovering radiation damage through high-temperature annealing cycles. We present an overview of the ePIC-dRICH photo-detector system. Special focus is given to development and beam test results of a large-area prototype SiPM readout plane consisting of a total of up to 2048 3×3 mm 2 sensors. The photo-detector prototype is modular and based on a novel EIC-driven photo-detection unit (PDU) developed by INFN, which integrates 256 SiPM pixel sensors, cooling and TDC electronics in a volume of ∼5×5×14 cm 3 . The prototype has been successfully tested with particle beams at CERN-PS in October 2023 and in May 2024. Results on ring images reconstructed, beam momentum scan and particle identification using the dual radiator configuration are presented. In addition, studies on radiation-induced defects using emission microscopy, and on annealing cycles used to recover radiation damage, are shown.
- Open Access
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , C07005
Beam test results of the SiPM photodetector prototype for the ePIC-dRICH detector at the EIC
Recent beam test results are presented for the prototype detector of the ePIC-dRICH forward particle-identification system at the EIC. A large-area prototype SiPM readout plane consisting of a total of up to 2048 3×3 mm2 sensors has been constructed. The photodetector prototype is modular and based on a novel EIC-driven photodetection unit developed by INFN, which integrates 256 SiPM pixel sensors, cooling and TDC electronics in a volume of ∼5 × 5 × 14 cm3. Several modules have been built and successfully tested with particle beams at CERN-PS in October 2023 and in May 2024. The data have been collected with a complete chain of front-end and readout electronics based on the ALCOR chip, developed by INFN Torino.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , C07005
Open AccessBeam test results of the SiPM photodetector prototype for the ePIC-dRICH detector at the EIC
Recent beam test results are presented for the prototype detector of the ePIC-dRICH forward particle-identification system at the EIC. A large-area prototype SiPM readout plane consisting of a total of up to 2048 3×3 mm2 sensors has been constructed. The photodetector prototype is modular and based on a novel EIC-driven photodetection unit developed by INFN, which integrates 256 SiPM pixel sensors, cooling and TDC electronics in a volume of ∼5 × 5 × 14 cm3. Several modules have been built and successfully tested with particle beams at CERN-PS in October 2023 and in May 2024. The data have been collected with a complete chain of front-end and readout electronics based on the ALCOR chip, developed by INFN Torino.
- Open Access
- 13 June 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (2)
Proof-of-principle demonstration of a pilot bunch comagnetometer in a stored beam
In polarization experiments at storage rings, one of the challenges is to maintain the spin-resonance condition of a radio-frequency spin rotator with the spin precessions of the orbiting particles. Time-dependent variations of the magnetic fields of ring elements lead to unwanted variations of the spin-precession frequency. We report here on a solution to this problem by shielding (or masking) one of the bunches stored in the ring from the high-frequency fields of the spin rotator, so that the masked pilot bunch acts as a comagnetometer for the other signal bunch, tracking fluctuations in the ring on a time scale of about one second. While the new method was developed primarily for searches of electric dipole moments of charged particles, it may have far-reaching implications for future spin physics facilities, such as the EIC and NICA. Published by the American Physical Society 2025
- 13 June 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (2)
Open AccessProof-of-principle demonstration of a pilot bunch comagnetometer in a stored beam
In polarization experiments at storage rings, one of the challenges is to maintain the spin-resonance condition of a radio-frequency spin rotator with the spin precessions of the orbiting particles. Time-dependent variations of the magnetic fields of ring elements lead to unwanted variations of the spin-precession frequency. We report here on a solution to this problem by shielding (or masking) one of the bunches stored in the ring from the high-frequency fields of the spin rotator, so that the masked pilot bunch acts as a comagnetometer for the other signal bunch, tracking fluctuations in the ring on a time scale of about one second. While the new method was developed primarily for searches of electric dipole moments of charged particles, it may have far-reaching implications for future spin physics facilities, such as the EIC and NICA. Published by the American Physical Society 2025