Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mihai Iovea has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simulation imaging process of laser-induced multi-MeV photon emission

    by L. Nita, A. C. Berceanu, J. F. Ong, G. Suliman, E. Hermann, M. Iovea

    A complete simulation chain for the laser-based generation of a microfocus-size gamma ray beam of multi-MeV energy range able to produce radiographic images has been developed. The major interactions needed to obtain such a beam are treated individually. Particle-in-cell is used to study the generation of the electron beam through laser wake-field acceleration (LWFA), and Geant4 is employed for the Bremsstrahlung photon emission and for testing the imaging capabilities of the generated gamma beam. The paper presents detailed discussions about the implementation of each simulation, along with the results obtained. The structure of the article walks through the LWFA of up to 100 MeV electron beam, followed by its attenuation through a tantalum foil generating a 300μm spot size photon beam, later used for imaging of a thick lead test-object, assessing a 100μm resolution, and confirming the simulated imaging setup suitability for non-destructive testing applications of thick high-density objects. An analysis of the quality control parameters for the generated image along with discussions of possible improvements is also included.


  • Open Access

    Material classification using basis material decomposition from spectral X-ray CT

    by Doniyor Jumanazarov, Asalkhon Alimova, Azamat Abdikarimov, Jakeoung Koo, Henning F. Poulsen, Ulrik L. Olsen, Mihai Iovea


  • Open Access

    Multi-Energy and Fast-Convergence Iterative Reconstruction Algorithm for Organic Material Identification Using X-ray Computed Tomography

    by Mihai Iovea, Andrei Stanciulescu, Edward Hermann, Marian Neagu, Octavian G. Duliu

    In order to significantly reduce the computing time while, at the same time, keeping the accuracy and precision when determining the local values of the density and effective atomic number necessary for identifying various organic material, including explosives and narcotics, a specialized multi-stage procedure based on a multi-energy computed tomography investigation within the 20–160 keV domain was elaborated. It consisted of a compensation for beam hardening and other non-linear effects that affect the energy dependency of the linear attenuation coefficient (LAC) in the chosen energy domain, followed by a 3D fast reconstruction algorithm capable of reconstructing the local LAC values for 64 energy values from 19.8 to 158.4 keV, and, finally, the creation of a set of algorithms permitting the simultaneous determination of the density and effective atomic number of the investigated materials. This enabled determining both the density and effective atomic number of complex objects in approximately 24 s, with an accuracy and precision of less than 3%, which is a significantly better performance with respect to the reported literature values.

  • Significance of the spectral correction of photon counting detector response in material classification from spectral x-ray CT

    by Doniyor Jumanazarov, Jakeoung Koo, Henning F. Poulsen, Ulrik L. Olsen, Mihai Iovea

    Purpose: Photon counting imaging detectors (PCD) has paved the way for spectral x-ray computed tomography (spectral CT), which simultaneously measures a sample’s linear attenuation coefficient (LAC) at multiple energies. However, cadmium telluride (CdTe)-based PCDs working under high flux suffer from detector effects, such as charge sharing and photon pileup. These effects result in the severe spectral distortions of the measured spectra and significant deviation of the extracted LACs from the reference attenuation curve. We analyze the influence of the spectral distortion correction on material classification performance. Approach: We employ a spectral correction algorithm to reduce the primary spectral distortions. We use a method for material classification that measures system-independent material properties, such as electron density, ρe, and effective atomic number, Zeff. These parameters are extracted from the LACs using attenuation decomposition and are independent of the scanner specification. The classification performance with the raw and corrected data is tested on different numbers of energy bins and projections and different radiation dose levels. We use experimental data with a broad range of materials in the range of 6 ≤ Zeff ≤ 15, acquired with a custom laboratory instrument for spectral CT. Results: We show that using the spectral correction leads to an accuracy increase of 1.6 and 3.8 times in estimating ρe and Zeff, respectively, when the image reconstruction is performed from only 12 projections and the 15 energy bins approach is used. Conclusions: The correction algorithm accurately reconstructs the measured attenuation curve and thus gives better classification performance.


  • System-independent material classification through X-ray attenuation decomposition from spectral X-ray CT

    by Doniyor Jumanazarov, Jakeoung Koo, Matteo Busi, Henning F. Poulsen, Ulrik L. Olsen, Mihai Iovea


  • Archimedean Spiral Antenna with Coplanar Waveguide Feed

    by A.C. Bunea, D. Neculoiu, A. Avram, M. Iovea

    This paper presents a wideband, membrane supported spiral antenna for millimeter wave applications. The slots of a coplanar waveguide transmission line are used to obtain the two winding arms of the spiral antenna A compact 5.3x5.3 mm 2 antenna is obtained with a measured input matching bandwidth larger than the 65 -110 GHz frequency range and a measured gain of 10.6 dBi. A 3D full wave electromagnetic model was developed and the simulated results are in good agreement with measurements.