Serdar Sanli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Serdar Sanli has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Suna Timur
Ege University
9 shared publications - Hichem Moulahoum
Biochemistry Department, Faculty of Science, Ege University, Izmir, Türkiye
7 shared publications - Dilek Odaci Demirkol
Ege University
3 shared publications - Emine Guler
Department of Bioengineering, Faculty of Engineering, Ege University, 35100 Izmir, Turkey
3 shared publications - Faezeh Ghorbanizamani
Biochemistry Department, Faculty of Science, Ege University, Izmir, Türkiye
3 shared publications Hakan Coskunol
Faculty of Medicine, Ege University, 35100, Bornova, Izmir, Turkey
3 shared publications
Latest Publications
- 1 September 2026
- Published by Elsevier in Materials Today Nano
- Vol. 35
Laser-induced graphene electrodes/Nd-MOF hybrid platform for selective electrochemical detection of cancer cells
- 1 September 2026
- Published by Elsevier in Materials Today Nano
- Vol. 35
Laser-induced graphene electrodes/Nd-MOF hybrid platform for selective electrochemical detection of cancer cells
- Open Access
- 5 June 2026
- Published by Springer Nature in Microchimica Acta
- Vol. 193 (7)
A truncated aptamer-based electrochemical sensor for sensitive Ara h 1 determination on gold nanoparticle-modified screen-printed electrodes
The online version contains supplementary material available at 10.1007/s00604-026-08153-w.
- 5 June 2026
- Published by Springer Nature in Microchimica Acta
- Vol. 193 (7)
Open AccessA truncated aptamer-based electrochemical sensor for sensitive Ara h 1 determination on gold nanoparticle-modified screen-printed electrodes
The online version contains supplementary material available at 10.1007/s00604-026-08153-w.
- Open Access
- 31 December 2023
- Published by Erzincan Universitesi Fen Bilimleri Ensitusu Dergisi in Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 16 (3) , 840-853
Design of a Novel Electrochemical Immunosensor for Toxoplasma gondii Detection Based on Gold Nanoparticle/Chitosan Decorated Screen Printed Electrode
Toxoplasma gondii is an intracellular parasite that primarily utilizes cats as its definitive host. This parasite, which is spread through cat feces, can be transmitted to other animals and, from there, to humans through various routes. In healthy individuals, this parasite may not cause severe illness, but it can be fatal, especially in individuals with weakened immune systems due to factors like chemotherapy or organ transplantation, as well as in fetuses developing in the womb. Given its relatively common occurrence worldwide, controlling the spread of this parasite is imperative. In this study, an antibody-based electrochemical biosensor was developed to directly detect Toxoplasma, offering potential applications in disease surveillance and management. The biosensor was designed using screen-printed electrodes, and the electrode surface was modified with chitosan and gold nanoparticles. Anti-Toxoplasma gondii antibodies were immobilized onto the modified electrode surface using glutaraldehyde as a cross-linking agent. Changes in surface properties were investigated using various techniques, including differential pulse voltammetry, cyclic voltammetry, and electrochemical impedance spectroscopy. The surface morphology of the developed immunosensor was visualized using scanning electron microscopy. Subsequently, the biosensor's linear working range and detection limit were determined, followed by its application in the detection of Toxoplasma gondii in synthetic serum samples. This innovative approach holds promise for the development of sensitive and specific diagnostic tools for Toxoplasma gondii infection, which is crucial for effective disease management and prevention, particularly in vulnerable populations.
- 31 December 2023
- Published by Erzincan Universitesi Fen Bilimleri Ensitusu Dergisi in Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
- Vol. 16 (3) , 840-853
Open AccessDesign of a Novel Electrochemical Immunosensor for Toxoplasma gondii Detection Based on Gold Nanoparticle/Chitosan Decorated Screen Printed Electrode
Toxoplasma gondii is an intracellular parasite that primarily utilizes cats as its definitive host. This parasite, which is spread through cat feces, can be transmitted to other animals and, from there, to humans through various routes. In healthy individuals, this parasite may not cause severe illness, but it can be fatal, especially in individuals with weakened immune systems due to factors like chemotherapy or organ transplantation, as well as in fetuses developing in the womb. Given its relatively common occurrence worldwide, controlling the spread of this parasite is imperative. In this study, an antibody-based electrochemical biosensor was developed to directly detect Toxoplasma, offering potential applications in disease surveillance and management. The biosensor was designed using screen-printed electrodes, and the electrode surface was modified with chitosan and gold nanoparticles. Anti-Toxoplasma gondii antibodies were immobilized onto the modified electrode surface using glutaraldehyde as a cross-linking agent. Changes in surface properties were investigated using various techniques, including differential pulse voltammetry, cyclic voltammetry, and electrochemical impedance spectroscopy. The surface morphology of the developed immunosensor was visualized using scanning electron microscopy. Subsequently, the biosensor's linear working range and detection limit were determined, followed by its application in the detection of Toxoplasma gondii in synthetic serum samples. This innovative approach holds promise for the development of sensitive and specific diagnostic tools for Toxoplasma gondii infection, which is crucial for effective disease management and prevention, particularly in vulnerable populations.
- 20 October 2023
- Published by Elsevier in Food Chemistry
- Vol. 437 (Pt 1) , 137823
Single-drop electrochemical immunosensor with 3D-printed magnetic attachment for onsite smartphone detection of amoxicillin in raw milk
- 20 October 2023
- Published by Elsevier in Food Chemistry
- Vol. 437 (Pt 1) , 137823
Single-drop electrochemical immunosensor with 3D-printed magnetic attachment for onsite smartphone detection of amoxicillin in raw milk
- Open Access
- 7 September 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (9) , 736
Magnetic Nanoparticle-Based Electrochemical Sensing Platform Using Ferrocene-Labelled Peptide Nucleic Acid for the Early Diagnosis of Colorectal Cancer
Diagnostic biomarkers based on epigenetic changes such as DNA methylation are promising tools for early cancer diagnosis. However, there are significant difficulties in directly and specifically detecting methylated DNA regions. Here, we report an electrochemical sensing system based on magnetic nanoparticles that enable a quantitative and selective analysis of the methylated septin9 (mSEPT9) gene, which is considered a diagnostic marker in early stage colorectal cancer (CRC). Methylation levels of SEPT9 in CRC samples were successfully followed by the selective recognition ability of a related peptide nucleic acid (PNA) after hybridization with DNA fragments in human patients’ serums and plasma (n = 10). Moreover, this system was also adapted into a point-of-care (POC) device for a one-step detection platform. The detection of mSEPT9 demonstrated a limit of detection (LOD) value of 0.37% and interference-free measurement in the presence of branched-chain amino acid transaminase 1 (BCAT1) and SRY box transcription factor 21 antisense divergent transcript 1 (SOX21-AS1). The currently proposed functional platform has substantial prospects in translational applications of early CRC detection.
- 7 September 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (9) , 736
Open AccessMagnetic Nanoparticle-Based Electrochemical Sensing Platform Using Ferrocene-Labelled Peptide Nucleic Acid for the Early Diagnosis of Colorectal Cancer
Diagnostic biomarkers based on epigenetic changes such as DNA methylation are promising tools for early cancer diagnosis. However, there are significant difficulties in directly and specifically detecting methylated DNA regions. Here, we report an electrochemical sensing system based on magnetic nanoparticles that enable a quantitative and selective analysis of the methylated septin9 (mSEPT9) gene, which is considered a diagnostic marker in early stage colorectal cancer (CRC). Methylation levels of SEPT9 in CRC samples were successfully followed by the selective recognition ability of a related peptide nucleic acid (PNA) after hybridization with DNA fragments in human patients’ serums and plasma (n = 10). Moreover, this system was also adapted into a point-of-care (POC) device for a one-step detection platform. The detection of mSEPT9 demonstrated a limit of detection (LOD) value of 0.37% and interference-free measurement in the presence of branched-chain amino acid transaminase 1 (BCAT1) and SRY box transcription factor 21 antisense divergent transcript 1 (SOX21-AS1). The currently proposed functional platform has substantial prospects in translational applications of early CRC detection.
- Open Access
- 1 January 2022
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 46 (4) , 1210-1225
Selective nanosensor based on folic acid imprinted nanostructures
Folic acid, which provides the transfer of single carbon atoms in synthesis reactions and metabolic cycles in metabolism, is very important for metabolism. Folic acid also plays an important role in nucleotide synthesis and methylation reactions. There are many disorders caused by defective folic acid metabolism and lack of folic acid. Today, innovative, cost-effective methods are needed to develop folic acid determination methods. The main objective of this study is the development of surface-printed carbon electrodes (SPCE) modified with folic acid imprinted nanostructures (FA-Imp-poly(MPTS-rGO-co-NAT), which will be used for the first time for folic acid determination in commercially human blood serum. For this purpose, the synthesis of nanostructures has been carried out and characterized by FTIR, SEM-EDS, and AFM. Then, a new chemically modified nanosensor was fabricated for the determination of folic acid using folic acid imprinted nanostructures. Differential pulse voltammetry (DPV) and circular voltammetry (CV) methods were used as electrochemical methods in the FA-imprinted-nanosensor studies. Measurements in differential pulse voltammetry were performed at an application speed of 0.005 volts per second in the potential range of ?0.4 to 0.6 volts. As a result of the circular voltammetric method, an idea about the surface was obtained with the voltammograms obtained. The detection limit (LOD) of the developed FA-imprinted-nanosensor was 7.54 ng/mL and the determination limit (LOQ) was 25.14 ng/mL. FA analytical (10 and 20 ng/mL) was added to commercial synthetic serum samples by the standard adding method and RSD values of 0.092% and 0.734% were found in the DPV technique and measurements respectively. This manuscript demonstrated a novel, simple, selective, and rapid FAimprinted- nanosensor for determining the FA in the biological samples.
- 1 January 2022
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 46 (4) , 1210-1225
Open AccessSelective nanosensor based on folic acid imprinted nanostructures
Folic acid, which provides the transfer of single carbon atoms in synthesis reactions and metabolic cycles in metabolism, is very important for metabolism. Folic acid also plays an important role in nucleotide synthesis and methylation reactions. There are many disorders caused by defective folic acid metabolism and lack of folic acid. Today, innovative, cost-effective methods are needed to develop folic acid determination methods. The main objective of this study is the development of surface-printed carbon electrodes (SPCE) modified with folic acid imprinted nanostructures (FA-Imp-poly(MPTS-rGO-co-NAT), which will be used for the first time for folic acid determination in commercially human blood serum. For this purpose, the synthesis of nanostructures has been carried out and characterized by FTIR, SEM-EDS, and AFM. Then, a new chemically modified nanosensor was fabricated for the determination of folic acid using folic acid imprinted nanostructures. Differential pulse voltammetry (DPV) and circular voltammetry (CV) methods were used as electrochemical methods in the FA-imprinted-nanosensor studies. Measurements in differential pulse voltammetry were performed at an application speed of 0.005 volts per second in the potential range of ?0.4 to 0.6 volts. As a result of the circular voltammetric method, an idea about the surface was obtained with the voltammograms obtained. The detection limit (LOD) of the developed FA-imprinted-nanosensor was 7.54 ng/mL and the determination limit (LOQ) was 25.14 ng/mL. FA analytical (10 and 20 ng/mL) was added to commercial synthetic serum samples by the standard adding method and RSD values of 0.092% and 0.734% were found in the DPV technique and measurements respectively. This manuscript demonstrated a novel, simple, selective, and rapid FAimprinted- nanosensor for determining the FA in the biological samples.
- 1 November 2020
- Published by Elsevier in Archives of Biochemistry and Biophysics
- Vol. 695, 108643
pH-bioresponsive poly(ε-caprolactone)-based polymersome for effective drug delivery in cancer and protein glycoxidation prevention
- 1 November 2020
- Published by Elsevier in Archives of Biochemistry and Biophysics
- Vol. 695, 108643
pH-bioresponsive poly(ε-caprolactone)-based polymersome for effective drug delivery in cancer and protein glycoxidation prevention
- 3 August 2020
- Published by Springer Nature in Biomedical Microdevices
- Vol. 22 (3) , 1-8
Ultrasensitive covalently-linked Aptasensor for cocaine detection based on electrolytes-induced repulsion/attraction of colloids
A quick and easy colorimetric sensor based on gold nanoparticles (GNPs) and aptamers for the detection of cocaine was developed. The sensor was named as ‘GAPTA’ and showed extremely interesting results regarding cocaine detection with a sensitivity to doses of 0.2 nM. The experimental approach consisted of creating a conjugate between GNPs (10 nm size) and aptamers as a sensing base with the addition of an electrolyte (NaCl) that plays the role of aggregation inducer. In the absence of the aptamer, the electrolyte was able to induce aggregation of the GNPs turning the color of the solution from red to blue while the presence of the aptamer is able to hinder the charges attraction and protects the GNPs from aggregating. The optimization of the aptamer and electrolyte concentration was determined to be 118 nM and 55 mM, respectively, and the resultant GAPTA sensor had a detection limit of 0.97 nM. Furthermore, the selectivity of the platform was tested in the presence of different interferents and showed a specific response towards cocaine while interference ranged between 20 and 40%. The applicability of the GAPTA biosensor was tested on synthetic saliva and demonstrated a sensitivity range between 0.2 and 25 nM. These results suggest the potential of the current colorimetric sensor in abuse drugs screening and creates a stable base for new routine platforms for biomedical and toxicology applications. Graphical abstract
- 3 August 2020
- Published by Springer Nature in Biomedical Microdevices
- Vol. 22 (3) , 1-8
Ultrasensitive covalently-linked Aptasensor for cocaine detection based on electrolytes-induced repulsion/attraction of colloids
A quick and easy colorimetric sensor based on gold nanoparticles (GNPs) and aptamers for the detection of cocaine was developed. The sensor was named as ‘GAPTA’ and showed extremely interesting results regarding cocaine detection with a sensitivity to doses of 0.2 nM. The experimental approach consisted of creating a conjugate between GNPs (10 nm size) and aptamers as a sensing base with the addition of an electrolyte (NaCl) that plays the role of aggregation inducer. In the absence of the aptamer, the electrolyte was able to induce aggregation of the GNPs turning the color of the solution from red to blue while the presence of the aptamer is able to hinder the charges attraction and protects the GNPs from aggregating. The optimization of the aptamer and electrolyte concentration was determined to be 118 nM and 55 mM, respectively, and the resultant GAPTA sensor had a detection limit of 0.97 nM. Furthermore, the selectivity of the platform was tested in the presence of different interferents and showed a specific response towards cocaine while interference ranged between 20 and 40%. The applicability of the GAPTA biosensor was tested on synthetic saliva and demonstrated a sensitivity range between 0.2 and 25 nM. These results suggest the potential of the current colorimetric sensor in abuse drugs screening and creates a stable base for new routine platforms for biomedical and toxicology applications. Graphical abstract