Haiyan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haiyan Li has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chunya Li
Key Laboratory of Catalysis and Energy Materials Chemistry of Ministry of Education & Hubei Key Laboratory of Catalysis and Materials Science & Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, South-Central Minzu University, Wuhan, 430074, China
2 shared publications Yanying Wang
Key Laboratory of Catalysis and Energy Materials Chemistry of Ministry of Education & Hubei Key Laboratory of Catalysis and Materials Science & Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, South-Central Minzu University, Wuhan 430074, China
2 shared publicationsLi Chai
Key Laboratory of Catalysis and Energy Materials Chemistry of Ministry of Education & Hubei Key Laboratory of Catalysis and Materials Science & Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, South-Central Minzu University, Wuhan 430074, China
1 shared publicationRenxi Liu
Key Laboratory of Catalysis and Energy Materials Chemistry of Ministry of Education & Hubei Key Laboratory of Catalysis and Materials Science & Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, South-Central University for Nationalities, Wuhan, China
1 shared publication- Tao Liang
Key Laboratory for the Synthesis and Application of Organic Functional Molecules (Ministry of Education), Hubei Province Key Laboratory of Biotechnology of Chinese Traditional Medicine, College of Health Science and Engineering
1 shared publication Wei Hu
College of Bioresources and Materials Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Shaanxi University of Science & Technology, Xi'an 710021, China
1 shared publication
Latest Publications
- 6 June 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 58 (52) , 7301-7304
A fast responsive and cell membrane-targetable near-infrared H 2 S fluorescent probe for drug resistance bioassays in chemotherapy
A fast responsive and cell membrane-targetable near-infrared H 2 S fluorescent probe was fabricated. Based on this probe, the close relationship between the overexpression of NFS1 and drug resistance in chemotherapy was further verified.
- 6 June 2022
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 58 (52) , 7301-7304
A fast responsive and cell membrane-targetable near-infrared H 2 S fluorescent probe for drug resistance bioassays in chemotherapy
A fast responsive and cell membrane-targetable near-infrared H 2 S fluorescent probe was fabricated. Based on this probe, the close relationship between the overexpression of NFS1 and drug resistance in chemotherapy was further verified.
- 2 August 2020
- Published by Springer Nature in Microchimica Acta
- Vol. 187 (8) , 1-9
Photoelectrochemical immunoassay platform based on MoS2 nanosheets integrated with gold nanostars for neuron-specific enolase assay
MoS2 nanosheets were prepared by exfoliating MoS2 bulk crystals with ultrasonication in N-methylpyrrolidone and were integrated with gold nanostars (AuNS) to fabricate an AuNS/MoS2 nanocomposite. All nanomaterials were characterized by transmission electron microscope, scanning electron microscope, ultraviolet-visible spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. AuNS/MoS2 nanocomposites were coated onto a glassy carbon electrode (GCE) surface to construct a nanointerface for immobilizing neuron-specific enolase antibody (anti-NSE) thus forming a photoelectrochemical immunoassay system. AuNS can significantly promote the photoelectric conversion of MoS2 nanosheets improving the performance for a photoelectrochemical assay. Being illuminated with white light LED and controlling the potential at 0.05 V (vs. SCE), the photocurrent generated from anti-NSE(BSA)/AuNS/MoS2/GCE using 0.15 mol L−1 ascorbic acid as electron donor can be recorded with amperometry and used as an output signal for NSE quantitative assay. Under optimized experimental conditions, the photocurrent variation for the affinity-binding NSE is proportional to the logarithm of NSE concentration in the range 5.0 pg mL-1 to 1.5 ng mL−1 with a detection limit of 3.5 pg mL−1 (S/N = 3). The practicability of the PEC immunoassay system was evaluated by determining NSE in clinical serum samples. The recoveries ranged from 93.0 to 103% for the determination of NSE in serum samples with a standard addition method. The PEC immunoassay system possesses good accuracy for determining NSE in real samples. Graphical abstract
- 2 August 2020
- Published by Springer Nature in Microchimica Acta
- Vol. 187 (8) , 1-9
Photoelectrochemical immunoassay platform based on MoS2 nanosheets integrated with gold nanostars for neuron-specific enolase assay
MoS2 nanosheets were prepared by exfoliating MoS2 bulk crystals with ultrasonication in N-methylpyrrolidone and were integrated with gold nanostars (AuNS) to fabricate an AuNS/MoS2 nanocomposite. All nanomaterials were characterized by transmission electron microscope, scanning electron microscope, ultraviolet-visible spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. AuNS/MoS2 nanocomposites were coated onto a glassy carbon electrode (GCE) surface to construct a nanointerface for immobilizing neuron-specific enolase antibody (anti-NSE) thus forming a photoelectrochemical immunoassay system. AuNS can significantly promote the photoelectric conversion of MoS2 nanosheets improving the performance for a photoelectrochemical assay. Being illuminated with white light LED and controlling the potential at 0.05 V (vs. SCE), the photocurrent generated from anti-NSE(BSA)/AuNS/MoS2/GCE using 0.15 mol L−1 ascorbic acid as electron donor can be recorded with amperometry and used as an output signal for NSE quantitative assay. Under optimized experimental conditions, the photocurrent variation for the affinity-binding NSE is proportional to the logarithm of NSE concentration in the range 5.0 pg mL-1 to 1.5 ng mL−1 with a detection limit of 3.5 pg mL−1 (S/N = 3). The practicability of the PEC immunoassay system was evaluated by determining NSE in clinical serum samples. The recoveries ranged from 93.0 to 103% for the determination of NSE in serum samples with a standard addition method. The PEC immunoassay system possesses good accuracy for determining NSE in real samples. Graphical abstract