Kenneth R. Mead
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenneth R. Mead has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- William G. Lindsley
Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
4 shared publications - Francoise M. Blachere
Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
3 shared publications - Jayme P. Coyle
Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention
2 shared publications - John D. Noti
Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
2 shared publications - Raymond C. Derk
Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
2 shared publications - Stephen B. Martin
Respiratory Health Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
2 shared publications
Latest Publications
- 1 September 2025
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 178 (9) , 1314-1325
Engineering Infection Controls to Reduce Indoor Transmission of Respiratory Infections
Engineering infection controls include a wide range of interventions used indoors to reduce occupants' exposure to respiratory pathogens. To identify and describe primary studies evaluating the effects of engineering infection control interventions designed to reduce the spread of respiratory infections transmitted through indoor air. MEDLINE, Embase, Global Health, Cochrane Central Register of Controlled Trials, CINAHL, Scopus, and Environmental Science Collection from database inception to 12 December 2023. English-language primary research articles evaluating engineering infection control interventions. Publication information, population characteristics, intervention details, and all relevant outcomes were abstracted by a reviewer and verified by a second, senior reviewer. A total of 672 studies published between 1929 and 2024 were identified. Most (n = 606) evaluated environmental samples only, 57 included human participants, and 9 included sentinel animal subjects. About half of the studies included at least 1 intervention classified as pathogen inactivation (n = 405), with fewer involving pathogen removal (n = 200) or air exchange or dilution (n = 143). Across all studies, about half (n = 332) measured the quantity of viable nonpathogenic organisms from air samples, followed by the quantity of nonbiological particulates (n = 197) or viable pathogenic organisms (n = 149). Harms, such as toxic byproducts, were rarely measured. Exclusion of non-English-language publications and gray literature. There is substantial heterogeneity in the available evidence. Gaps in evidence include studies measuring efficacy outcomes that are highly relevant for human infection transmission or harms. Refinements in classification of interventions and outcomes could strengthen reporting of these evaluations. National Institute for Occupational Safety and Health at the Centers for Disease Control and Prevention. (Registered on Open Science Framework [https://osf.io/5zmhd]).
- 1 September 2025
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 178 (9) , 1314-1325
Engineering Infection Controls to Reduce Indoor Transmission of Respiratory Infections
Engineering infection controls include a wide range of interventions used indoors to reduce occupants' exposure to respiratory pathogens. To identify and describe primary studies evaluating the effects of engineering infection control interventions designed to reduce the spread of respiratory infections transmitted through indoor air. MEDLINE, Embase, Global Health, Cochrane Central Register of Controlled Trials, CINAHL, Scopus, and Environmental Science Collection from database inception to 12 December 2023. English-language primary research articles evaluating engineering infection control interventions. Publication information, population characteristics, intervention details, and all relevant outcomes were abstracted by a reviewer and verified by a second, senior reviewer. A total of 672 studies published between 1929 and 2024 were identified. Most (n = 606) evaluated environmental samples only, 57 included human participants, and 9 included sentinel animal subjects. About half of the studies included at least 1 intervention classified as pathogen inactivation (n = 405), with fewer involving pathogen removal (n = 200) or air exchange or dilution (n = 143). Across all studies, about half (n = 332) measured the quantity of viable nonpathogenic organisms from air samples, followed by the quantity of nonbiological particulates (n = 197) or viable pathogenic organisms (n = 149). Harms, such as toxic byproducts, were rarely measured. Exclusion of non-English-language publications and gray literature. There is substantial heterogeneity in the available evidence. Gaps in evidence include studies measuring efficacy outcomes that are highly relevant for human infection transmission or harms. Refinements in classification of interventions and outcomes could strengthen reporting of these evaluations. National Institute for Occupational Safety and Health at the Centers for Disease Control and Prevention. (Registered on Open Science Framework [https://osf.io/5zmhd]).
- 27 January 2025
- Published by Elsevier in Building and Environment
- Vol. 271
Reductions in exposures to simulated respiratory aerosols by a ceiling-mounted HEPA air filtration unit
- 27 January 2025
- Published by Elsevier in Building and Environment
- Vol. 271
Reductions in exposures to simulated respiratory aerosols by a ceiling-mounted HEPA air filtration unit
- 22 December 2021
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 43 (12) , 1987-1989
Virus decay rates should not be used to reduce recommended room air clearance times
- 22 December 2021
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 43 (12) , 1987-1989
Virus decay rates should not be used to reduce recommended room air clearance times
- Open Access
Efficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room
There is strong evidence associating the indoor environment with transmission of SARS-CoV-2, the virus that causes COVID-19. SARS-CoV-2 can spread by exposure to droplets and very fine aerosol particles from respiratory fluids that are released by infected persons. Layered mitigation strategies, including but not limited to maintaining physical distancing, adequate ventilation, universal masking, avoiding overcrowding, and vaccination, have shown to be effective in reducing the spread of SARS-CoV-2 within the indoor environment. Here, we examine the effect of mitigation strategies on reducing the risk of exposure to simulated respiratory aerosol particles within a classroom-style meeting room. To quantify exposure of uninfected individuals (Recipients), surrogate respiratory aerosol particles were generated by a breathing simulator with a headform (Source) that mimicked breath exhalations. Recipients, represented by three breathing simulators with manikin headforms, were placed in a meeting room and affixed with optical particle counters to measure 0.3–3 µm aerosol particles. Universal masking of all breathing simulators with a 3-ply cotton mask reduced aerosol exposure by 50% or more compared to scenarios with simulators unmasked. While evaluating the effect of Source placement, Recipients had the highest exposure at 0.9 m in a face-to-face orientation. Ventilation reduced exposure by approximately 5% per unit increase in air change per hour (ACH), irrespective of whether increases in ACH were by the HVAC system or portable HEPA air cleaners. The results demonstrate that mitigation strategies, such as universal masking and increasing ventilation, reduce personal exposure to respiratory aerosols within a meeting room. While universal masking remains a key component of a layered mitigation strategy of exposure reduction, increasing ventilation via system HVAC or portable HEPA air cleaners further reduces exposure.
Open AccessEfficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room
There is strong evidence associating the indoor environment with transmission of SARS-CoV-2, the virus that causes COVID-19. SARS-CoV-2 can spread by exposure to droplets and very fine aerosol particles from respiratory fluids that are released by infected persons. Layered mitigation strategies, including but not limited to maintaining physical distancing, adequate ventilation, universal masking, avoiding overcrowding, and vaccination, have shown to be effective in reducing the spread of SARS-CoV-2 within the indoor environment. Here, we examine the effect of mitigation strategies on reducing the risk of exposure to simulated respiratory aerosol particles within a classroom-style meeting room. To quantify exposure of uninfected individuals (Recipients), surrogate respiratory aerosol particles were generated by a breathing simulator with a headform (Source) that mimicked breath exhalations. Recipients, represented by three breathing simulators with manikin headforms, were placed in a meeting room and affixed with optical particle counters to measure 0.3–3 µm aerosol particles. Universal masking of all breathing simulators with a 3-ply cotton mask reduced aerosol exposure by 50% or more compared to scenarios with simulators unmasked. While evaluating the effect of Source placement, Recipients had the highest exposure at 0.9 m in a face-to-face orientation. Ventilation reduced exposure by approximately 5% per unit increase in air change per hour (ACH), irrespective of whether increases in ACH were by the HVAC system or portable HEPA air cleaners. The results demonstrate that mitigation strategies, such as universal masking and increasing ventilation, reduce personal exposure to respiratory aerosols within a meeting room. While universal masking remains a key component of a layered mitigation strategy of exposure reduction, increasing ventilation via system HVAC or portable HEPA air cleaners further reduces exposure.
- 8 March 2021
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 6 (3) , L031601
Aerosol agitation: Quantifying the hydrodynamic stressors on particulates encapsulated in small droplets
Lower respiratory tract infections originate from multiple aerosol sources, varying from droplets erupting from bursting bubbles in a toilet or those produced by human speech. A key component of the aerosol-based infection pathway—from source to potential host—is the survival of the pathogen during aerosolization. Due to their finite-time instability, pinch-off processes occurring during aerosolization have the potential to rapidly accelerate the fluid into focused regions of these droplets, stress objects therein, and if powerful enough, disrupt biological life. However, the extent that a pathogen will be exposed to damaging hydrodynamic stressors during the aerosolization process is unknown. Here we compute the probability that particulates will be exposed to a hydrodynamic stressor during the generation of droplets that range in size from one to 100 microns. For example, particulates in water droplets less than 5 have a 50% chance of being subjected to an energy dissipation rate in excess of , hydrodynamic stresses in excess of Pa, and strain rates in excess of , values known to damage certain biological cells. Using a combination of numerical simulations and self-similar dynamics, we show how the exposure within a droplet can be generally predicted from its size, surface tension, and density, even across different aerosolization mechanisms. Collectively, these results introduce aerosol agitation as a potential factor in pathogen transmission and implicate the pinch-off singularity flow as setting the distribution of hydrodynamic stressors experienced within the droplet.- 8 March 2021
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 6 (3) , L031601
Aerosol agitation: Quantifying the hydrodynamic stressors on particulates encapsulated in small droplets
Lower respiratory tract infections originate from multiple aerosol sources, varying from droplets erupting from bursting bubbles in a toilet or those produced by human speech. A key component of the aerosol-based infection pathway—from source to potential host—is the survival of the pathogen during aerosolization. Due to their finite-time instability, pinch-off processes occurring during aerosolization have the potential to rapidly accelerate the fluid into focused regions of these droplets, stress objects therein, and if powerful enough, disrupt biological life. However, the extent that a pathogen will be exposed to damaging hydrodynamic stressors during the aerosolization process is unknown. Here we compute the probability that particulates will be exposed to a hydrodynamic stressor during the generation of droplets that range in size from one to 100 microns. For example, particulates in water droplets less than 5 have a 50% chance of being subjected to an energy dissipation rate in excess of , hydrodynamic stresses in excess of Pa, and strain rates in excess of , values known to damage certain biological cells. Using a combination of numerical simulations and self-similar dynamics, we show how the exposure within a droplet can be generally predicted from its size, surface tension, and density, even across different aerosolization mechanisms. Collectively, these results introduce aerosol agitation as a potential factor in pathogen transmission and implicate the pinch-off singularity flow as setting the distribution of hydrodynamic stressors experienced within the droplet.- 31 July 2020
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 54 (10) , 1117-1123
COVID-19 and the workplace: Research questions for the aerosol science community
(2020). COVID-19 and the workplace: Research questions for the aerosol science community. Aerosol Science and Technology. Ahead of Print.
- 31 July 2020
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 54 (10) , 1117-1123
COVID-19 and the workplace: Research questions for the aerosol science community
(2020). COVID-19 and the workplace: Research questions for the aerosol science community. Aerosol Science and Technology. Ahead of Print.