Rushan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rushan Liu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Deyuan Tian
Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration, Harbin 150080, China
3 shared publications Jinlong Liu
China Earthquake Administration
2 shared publicationsMingpan Xiong
Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration, Harbin 150080, China
2 shared publicationsRongxing Shu
2 shared publicationsYixiang Hong
China Earthquake Administration
2 shared publicationsZhenhui Wang
China Earthquake Administration
2 shared publications
Latest Publications
- 14 October 2025
- Published by Springer Nature
- p. 317-328
Seismic Vulnerability of Onshore Wind Turbine Towers Under Various Site Conditions
- 14 October 2025
- Published by Springer Nature
- p. 317-328
Seismic Vulnerability of Onshore Wind Turbine Towers Under Various Site Conditions
- Open Access
- 29 June 2024
- Published by Atlantis Press SARL
- p. 812-825
Seismic Vulnerability of Onshore Wind Farms
- 29 June 2024
- Published by Atlantis Press SARL
- p. 812-825
Open AccessSeismic Vulnerability of Onshore Wind Farms
- Open Access
- 13 April 2022
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2022, 1-10
Seismic Vulnerability Assessment of Thermal Power Plants Based on Beta Function
The study on seismic vulnerability of thermal power plants is of great significance for seismic damage prevention of the electrical power system and risk analysis of seismic economic loss. This paper presented a study method for obtaining the seismic vulnerability matrix and vulnerability curve of thermal power plants based on beta function. Firstly, according to the study results of thermal power plants in American ATC-25 report, the expected values of seismic damage indexes of thermal power plants under different seismic intensities were calculated. It was assumed that the expected values of seismic damage indexes of substation and thermal power plant were the same, and the dispersion of distribution of seismic damage indexes was the same. Then, based on the actual seismic vulnerability matrix of substations obtained from statistics in Wenchuan earthquake, the seismic vulnerability matrix of thermal power plants under different seismic intensities was fitted by using the probability density function of beta distribution. Finally, the seismic vulnerability curve of the thermal power plant based on peak ground acceleration (PGA) was obtained by using the cumulative function curve of standard lognormal distribution. The calculation results show that the seismic damage ratio calculated from the seismic vulnerability matrix of thermal power plants is basically consistent with the seismic damage ratio in ATC-25 report.
- 13 April 2022
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2022, 1-10
Open AccessSeismic Vulnerability Assessment of Thermal Power Plants Based on Beta Function
The study on seismic vulnerability of thermal power plants is of great significance for seismic damage prevention of the electrical power system and risk analysis of seismic economic loss. This paper presented a study method for obtaining the seismic vulnerability matrix and vulnerability curve of thermal power plants based on beta function. Firstly, according to the study results of thermal power plants in American ATC-25 report, the expected values of seismic damage indexes of thermal power plants under different seismic intensities were calculated. It was assumed that the expected values of seismic damage indexes of substation and thermal power plant were the same, and the dispersion of distribution of seismic damage indexes was the same. Then, based on the actual seismic vulnerability matrix of substations obtained from statistics in Wenchuan earthquake, the seismic vulnerability matrix of thermal power plants under different seismic intensities was fitted by using the probability density function of beta distribution. Finally, the seismic vulnerability curve of the thermal power plant based on peak ground acceleration (PGA) was obtained by using the cumulative function curve of standard lognormal distribution. The calculation results show that the seismic damage ratio calculated from the seismic vulnerability matrix of thermal power plants is basically consistent with the seismic damage ratio in ATC-25 report.
- Open Access
- 9 January 2021
- Published by Wiley in Advances in Civil Engineering
- Vol. 2021 (1)
Relationship between Damage Rate of High‐Voltage Electrical Equipment and Instrumental Seismic Intensity
Based on the actual damage data of high‐voltage electrical equipment in electric substations in the Wenchuan earthquake, this paper uses the cumulative Gaussian distribution function to describe the relationship between the damage rate of high‐voltage electrical equipment and the instrumental seismic intensity. The instrumental seismic intensity at strong motion observation stations in the Wenchuan earthquake is calculated, and the Kriging interpolation method is used to estimate the instrumental seismic intensity at 110 kV and above voltage level substations in Mianyang, Deyang, Guangyuan, and Chengdu of Sichuan Province. A cumulative Gaussian distribution function is then used to fit the damage rate‐instrumental seismic intensity relationship curve for six types of high‐voltage electrical equipment such as the transformer, circuit breaker, voltage mutual inductor, current mutual inductor, isolating switch, and lightning arrester. The results show that transformers have the highest vulnerability during earthquakes, and they suffered a certain level of damage even under low instrumental intensity. The second most vulnerable equipment is the circuit breaker, followed by the lightning arrester, transformer, and isolating switch, which share a similar vulnerability curve.
- 9 January 2021
- Published by Wiley in Advances in Civil Engineering
- Vol. 2021 (1)
Open AccessRelationship between Damage Rate of High‐Voltage Electrical Equipment and Instrumental Seismic Intensity
Based on the actual damage data of high‐voltage electrical equipment in electric substations in the Wenchuan earthquake, this paper uses the cumulative Gaussian distribution function to describe the relationship between the damage rate of high‐voltage electrical equipment and the instrumental seismic intensity. The instrumental seismic intensity at strong motion observation stations in the Wenchuan earthquake is calculated, and the Kriging interpolation method is used to estimate the instrumental seismic intensity at 110 kV and above voltage level substations in Mianyang, Deyang, Guangyuan, and Chengdu of Sichuan Province. A cumulative Gaussian distribution function is then used to fit the damage rate‐instrumental seismic intensity relationship curve for six types of high‐voltage electrical equipment such as the transformer, circuit breaker, voltage mutual inductor, current mutual inductor, isolating switch, and lightning arrester. The results show that transformers have the highest vulnerability during earthquakes, and they suffered a certain level of damage even under low instrumental intensity. The second most vulnerable equipment is the circuit breaker, followed by the lightning arrester, transformer, and isolating switch, which share a similar vulnerability curve.
- Open Access
- 27 July 2020
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2020, 1-10
Study on Analogy Calculation Method for Seismic Vulnerability of Earth-Wood Structure Houses
Earth-wood structure houses often cause large casualties and economic losses in historical earthquakes. Therefore, it is estimated that the seismic vulnerability of civil structures in areas that have not experienced earthquakes is of great significance for earthquake prevention and disaster reduction. In this paper, an analogy calculation method was proposed for calculating the seismic vulnerability of earth-wood structure houses in unknown regions from the seismic vulnerability of earth-wood structure houses in known regions. Firstly, the main factors affecting the seismic capacity of earth-wood structure houses were determined, and the weights of influence of influencing factors on the overall seismic capacities of buildings under different seismic intensities were determined by using the fuzzy analytical hierarchy approach; secondly, the relative seismic capacities of the main influencing factors are analogically scored by considering the differences in influencing factors in different regions. Finally, based on the vulnerability matrix of earth-wood structure houses in existing regions and comprehensive evaluation of relative seismic capacities of earth-wood structures, the vulnerability matrix of unknown earth-wood structures was calculated by analogy. The results of trial calculation showed that this method has higher reliability and effectiveness. At the end of the article, the vulnerability analysis of earth-wood structure houses in Shigatse, Tibet, was carried out using this method, and the vulnerability curve was initially given.
- 27 July 2020
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2020, 1-10
Open AccessStudy on Analogy Calculation Method for Seismic Vulnerability of Earth-Wood Structure Houses
Earth-wood structure houses often cause large casualties and economic losses in historical earthquakes. Therefore, it is estimated that the seismic vulnerability of civil structures in areas that have not experienced earthquakes is of great significance for earthquake prevention and disaster reduction. In this paper, an analogy calculation method was proposed for calculating the seismic vulnerability of earth-wood structure houses in unknown regions from the seismic vulnerability of earth-wood structure houses in known regions. Firstly, the main factors affecting the seismic capacity of earth-wood structure houses were determined, and the weights of influence of influencing factors on the overall seismic capacities of buildings under different seismic intensities were determined by using the fuzzy analytical hierarchy approach; secondly, the relative seismic capacities of the main influencing factors are analogically scored by considering the differences in influencing factors in different regions. Finally, based on the vulnerability matrix of earth-wood structure houses in existing regions and comprehensive evaluation of relative seismic capacities of earth-wood structures, the vulnerability matrix of unknown earth-wood structures was calculated by analogy. The results of trial calculation showed that this method has higher reliability and effectiveness. At the end of the article, the vulnerability analysis of earth-wood structure houses in Shigatse, Tibet, was carried out using this method, and the vulnerability curve was initially given.
- Open Access
- 31 August 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 397 (1) , 012027
Research on assessment method of cascading hazard to substation by earthquake damage
- 31 August 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 397 (1) , 012027
Open AccessResearch on assessment method of cascading hazard to substation by earthquake damage
- Open Access
- 1 January 2017
- Published by Atlantis Press SARL
Study on Damage Probability of High Voltage Electrical Equipment under Different Seismic Intensity
- 1 January 2017
- Published by Atlantis Press SARL
Open AccessStudy on Damage Probability of High Voltage Electrical Equipment under Different Seismic Intensity
- 1 December 2006
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 5 (2) , 189-193
An improved pseudo-static method for seismic resistant design of underground structures
- 1 December 2006
- Published by Springer Nature in Earthquake Engineering and Engineering Vibration
- Vol. 5 (2) , 189-193
An improved pseudo-static method for seismic resistant design of underground structures
- 1 March 2006
- Published by Springer Nature in Acta Seismologica Sinica
- Vol. 19 (2) , 207-216
Study on financial loss and its adjustment in earthquake insurance
- 1 March 2006
- Published by Springer Nature in Acta Seismologica Sinica
- Vol. 19 (2) , 207-216
Study on financial loss and its adjustment in earthquake insurance