TQTong Qiao

Tong Qiao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tong Qiao has a total of 78 co-authors. Here are the top co-authors by number of shared publications:

  • Haiyun Ye

    Department of Ophthalmology, Shanghai Children's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China

    9 shared publications
  • Siying Wang

    Department of Ophthalmology, Shanghai Children’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China

    6 shared publications
  • Wangyi Fang

    Department of Ophthalmology, Shanghai Children's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China

    6 shared publications
  • Ce Zheng

    Department of Ophthalmology, XinHua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China

    5 shared publications
  • Han Ye

    Department of Ophthalmology, Shanghai Children’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China

    5 shared publications
  • Yidan Zhang

    Department of Ophthalmology, Shanghai Children’s Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China

    5 shared publications

Latest Publications

  • Open Access

    Ophthalmic phenotype and strabismus surgery in Angelman syndrome: genotype-specific risks and uniform surgical efficacy

    by Kai Xu, Xin Chen, Xinyue Li, Zupeng Lu, Xiaoting Zhou, Wangyi Fang, Xiaodong Du, Kourosh Shahraki, Donny W. Suh, Tong Qiao

  • Open Access

    Home-based perceptual learning augments high-frequency contrast sensitivity and stereopsis after esotropia surgery: A retrospective cohort study

    by Kai Xu, Wenting Luo, Haiyun Ye, Xiaodong Du, Wen Li, Yue Di, Ce Zheng, Kourosh Shahraki, Donny W. Suh, Tong Qiao


  • Open Access

    Bilateral superior oblique suture extension in pediatric A-pattern esotropia

    by Ye Haiyun, Fang Wangyi, Cheng Chi, Liu Qingyu, Zhang Yidan, Li Yuan, Kourosh Shahraki, Donny W Suh, Qiao Tong

    Background: A-pattern esotropia is defined as an increase of more than 10 prism diopters (PD) divergence in down-gaze than in up-gaze. The long-term outcomes of bilateral superior oblique tendon suture extension (SOSE), a hardware-free technique, were evaluated in pediatric A-pattern esotropia with bilateral superior oblique overaction (bi-SOOA), addressing complications associated with traditional silicone spacers and tenotomy. Methods: In this retrospective cohort study, all participants with A-pattern esotropia and bi-SOOA underwent bilateral SOSE using nonabsorbable polypropylene sutures combined with medial rectus recession. Preoperative and postoperative assessments included prism cover testing in nine gazes, fundus photography for objective torsion quantification, and grading of superior oblique overaction (SOOA). Results: This study included 64 eyes from 32 children with a mean (SD) age of 7.0 (3.1) years and a mean (SD) postoperative follow-up of 35.2 (15.6) months (range: 8–55). The mean (SD) A-pattern esodeviation collapsed from 23.4 (7.7) PD preoperatively to 2.4 (2.3) PD postoperatively (P < 0.001), representing an 88.3% reduction. The mean (SD) horizontal esodeviation improved from 37.5 (10.9) PD to 1.7 (1.8) PD in primary gaze (P < 0.001). The mean (SD) objective fundus torsion decreased from 10.9 (2.5) degrees to 1.1 (1.4) degrees (P < 0.001), with no cases of torsional diplopia or vertical deviation. SOOA grades normalized from 2.8 (0.7) to 0.2 (0.4) (P < 0.001). No suture-related complications were observed, and alignment stability was maintained through to the final follow-up visit. Conclusions: In pediatric A-pattern esodeviation surgery, SOSE provided biomechanical precision, anatomical preservation, and elimination of hardware-related risks. Its effectiveness in collapsing A-pattern esotropia, normalizing torsion, and achieving durable outcomes establishes it as a first-line surgical intervention for bi-SOOA. This study addresses a significant gap in pediatric ophthalmology, offering extended follow-up data and highlighting the value of minimally invasive, growth-compatible techniques in protecting visual development. Larger randomized trials with extended follow-up are needed to confirm the efficacy and safety of this procedure for A-pattern esotropia.

  • Open Access

    Surgical treatment and levator muscle protein analysis of congenital ptosis in craniosynostosis: A case-control study

    by Qingyu Liu, Wen Li, Yidan Zhang, Kai Xu, Tong Qiao

    In this study, we compared the differences between children with craniosynostosis and those diagnosed with severe congenital ptosis who received conjoint fascial sheath suspension surgery. This study included 39 children, 19 craniosynostosis children (23 eyes, 10 males, and 9 females), and 20 children (23 eyes, 10 males, and 10 females) in the control group. All the patients were diagnosed with congenital ptosis and underwent conjoint fascial sheath suspension surgery. The levator muscle was analyzed using proteomics. There were no differences in age, margin-to-reflex distance 1, or levator function between the craniosynostosis and control groups. In the craniosynostosis group, there were 2 children (3 eyes) with exposed keratitis at 1 week follow-up. In total, 2133 proteins were identified. To characterize the molecular features, gene oncology and Kyoto Encyclopedia of Genes and Genomes pathway were investigated. Eighteen proteins in the craniosynostosis group were found to be significantly different from those in the control group, including 12 upregulated and 6 downregulated proteins. There were no differences in age, margin-to-reflex distance 1, or levator function between the craniosynostosis and control groups. Protein analysis of the levator muscle revealed differences in gene oncology and molecular functions. Due to exophthalmos in children with craniosynostosis, the suspension should not overcorrect too much to avoid the occurrence of exposed keratitis after surgery.

  • Open Access

    Binocular Visual Performance Improvement in Children Following Overnight Orthokeratology Lens Wearing

    by Wen-Ting Luo, Yue Di, Ying Huang, Xiao-Dong M.R. Du, Tong Qiao

    Background: Orthokeratology (OK) lenses are used to control myopia progression in children. Few studies have described the changes in stereoacuity scores and fusion ranges in OK-treated children. Objectives: This study sought to investigate the effects of short-term OK lens wearing on binocular visual function, including fusion and stereoacuity, in children successfully fit with OK lenses. Methods: This prospective study included 36 children with ideal lens fitting (treatment zone decentration P0.05). Conclusions: The CS and AC/A ratio remained unchanged after OK lens wear, while the stereoacuity score and fusion range improved in the pediatric population. These findings suggest that OK lens wearing improves or maintains binocular vision function in myopic children who achieve good visual performance with OK lenses (ChiCTR2000038600, registered September 24, 2020).September 24, 2020).


  • Open Access

    Clinical outcomes of posterior scleral reinforcement in Chinese high myopia children

    by Haiyun Ye, Ruizhi Tang, Wangyi Fang, Yue Di, Tong Qiao

    We aim to observe the posterior scleral reinforcement (PSR) clinical outcomes of children with high myopia and analyze the retinal vessel alteration before and after PSR by using angiography optical coherence tomography (angio-OCT). Fifty-six pediatric participants (112 eyes) clinically diagnosed high myopia were recruited and were treated by PSR in Shanghai Children’s Hospital from June 1, 2021 to May 1, 2023. The average age ranged from 5.42 to 14.83 years (mean 8.83 years) and mean follow up duration was 8.7 months (3–24 months). The axial length (AL) was significantly shortened after PSR (p < 0.05). The spherical equivalent (SE) and the best-corrected visual acuity (BCVA) were also improved without severe rejection in the follow-up. Compared with baseline, angio-OCT parafoveal vessel indices including vascular area density (VAD) and vascular skeleton density (VSD) on the superficial capillary plexus layer (SCPL), as well as VAD and vessel perimeter index (VPI) on the deep capillary plexus layer (DCPL), were significantly increased after PSR surgery (p < 0.05). VPI on the SCPL, vascular diameter index (VDI) and VSD on the DCPL were also improved without statistical difference after PSR. The VSD on SCPL, VAD on DCPL of the right eyes and the VPI on SCPL of the left eyes were significantly increased after PSR (p < 0.05). PSR surgery can shorten the AL and can stable BCVA and SE in high myopia children. The angio-OCT parameters indicated that the retinal microcirculation supply was significantly improved after PSR.


  • Open Access

    Automated detection of steps in videos of strabismus surgery using deep learning

    by Ce Zheng, Wen Li, Siying Wang, Haiyun Ye, Kai Xu, Wangyi Fang, Yanli Dong, Zilei Wang, Tong Qiao

    Background: Learning to perform strabismus surgery is an essential aspect of ophthalmologists’ surgical training. Automated classification strategy for surgical steps can improve the effectiveness of training curricula and the efficient evaluation of residents’ performance. To this end, we aimed to develop and validate a deep learning (DL) model for automated detecting strabismus surgery steps in the videos. Methods: In this study, we gathered 479 strabismus surgery videos from Shanghai Children’s Hospital, affiliated to Shanghai Jiao Tong University School of Medicine, spanning July 2017 to October 2021. The videos were manually cut into 3345 clips of the eight strabismus surgical steps based on the International Council of Ophthalmology’s Ophthalmology Surgical Competency Assessment Rubrics (ICO-OSCAR: strabismus). The videos dataset was randomly split by eye-level into a training (60%), validation (20%) and testing dataset (20%). We evaluated two hybrid DL algorithms: a Recurrent Neural Network (RNN) based and a Transformer-based model. The evaluation metrics included: accuracy, area under the receiver operating characteristic curve, precision, recall and F1-score. Results: DL models identified the steps in video clips of strabismus surgery achieved macro-average AUC of 1.00 (95% CI 1.00–1.00) with Transformer-based model and 0.98 (95% CI 0.97-1.00) with RNN-based model, respectively. The Transformer-based model yielded a higher accuracy compared with RNN-based models (0.96 vs. 0.83, p < 0.001). In detecting different steps of strabismus surgery, the predictive ability of the Transformer-based model was better than that of the RNN. Precision ranged between 0.90 and 1 for the Transformer-based model and 0.75 to 0.94 for the RNN-based model. The f1-score ranged between 0.93 and 1 for the Transformer-based model and 0.78 to 0.92 for the RNN-based model. Conclusion: The DL models can automate identify video steps of strabismus surgery with high accuracy and Transformer-based algorithms show excellent performance when modeling spatiotemporal features of video frames.


  • Open Access

    Microvasculature evaluation of anisometropic amblyopia children by Angio-OCT

    by Haiyun Ye, Siying Wang, Yidan Zhang, Wangyi Fang, Han Ye, Luya Chen, Tong Qiao

    To compare and assess the choroidal and retinal microstructural vascularity in amblyopic eyes with the fellow eyes in anisometropic amblyopic children using angiography optical coherence tomography (Angio-OCT). Twenty-seven children (54 eyes; 5.59 ± 1.08 years old; 59.3% girls) were enrolled in this study. Choroidal thickness (CT) was measured with the use of the enhanced depth imaging mode in Angio-OCT. Parafoveal/peripapillary vascular density indices and the foveal avascular zone (FAZ) size were analyzed by MATLAB code programming on Angio-OCT images. The mean FAZ size of the amblyopic eyes were larger both in superficial and deep capillary plexus layer (SCPL/DCPL). Compared with the contralateral eyes (BCVA were normal), all the vascular density indices of SCPL and DCPL in the parafoveal and peripapillary zones were lower in the amblyopic eyes, however, the difference was insignificant (p > 0.05). No significant decrease was observed in four quadrants analyses of the amblyopic eyes (p > 0.05). Except for the measurement at 2000 µm and 1500 µm from the fovea in temple, CT in amblyopic eyes were significantly thicken than the fellow eyes (p < 0.05). Compared with the fellow eyes, the CT of certain areas were thicker in the amblyopic eyes. Though the FAZ size of the amblyopic eyes was larger in SCPL/DCPL layers, the retinal vascular density indices in SCPL/DCPL were lower in amblyopia eyes without statistical difference. Angio-OCT may be an effective way to evaluate the status of the choroidal and retinal vascular system in amblyopic children.


  • Development and Validation of a Simple Nomogram for Predicting Rapid Myopia Progression in Children with Orthokeratology Management

    by Ying Huang, Xinyue Li, Wangyi Fang, Wenting Luo, Han Ye, Xiaodong Du, Yue Di, Tong Qiao

    To develop and validate an ideal nomogram and an online calculator for predicting rapid myopia progression risk in children managed with orthokeratology (ortho-k).Data of children undergoing ortho-...


  • Open Access

    Microvasculature evaluation of monocular anisometropic amblyopia children by Angio-OCT

    by Haiyun Ye, Siying Wang, Yidan Zhang, Wangyi Fang, Han Ye, Luya Chen, Tong Qiao

    Background To compare and assess the choroidal and retinal microstructural vascularity in amblyopic eyes with the fellow eyes in monocular anisometropic amblyopic children using angiography optical coherence tomography (Angio-OCT). Methods Twenty-seven children (54 eyes; 5.59 ± 1.08 years old; 59.3% girls) were enrolled in this study. Choroidal thickness (CT) was measured with the use of the enhanced depth imaging mode in Angio-OCT. Parafoveal/peripapillary vascular density indices and the foveal avascular zone (FAZ) size were analyzed by Matlab code programming on Angio-OCT images. Results The mean FAZ size of the amblyopic eyes were larger both in superficial and deep capillary plexus layer (SCPL/DCPL). Compared with the contralateral eyes (which were emmetropia), all the vascular density indices of SCPL and DCPL in the parafoveal and peripapillary zones were lower in the amblyopic eyes, however, the difference were insignificant (p > 0.05). No significant decrease was observed in four quadrants analyses of the amblyopic eyes (p > 0.05). Except for the measurement at 2000µm and 1500µm from the fovea in temple, CT in amblyopic eyes were significantly thicken than the fellow eyes (p < 0.05). Conclusion Compared with the fellow eyes, the CT of certain areas were thicker in the amblyopic eyes. Though the FAZ size of the amblyopic eyes were obvious larger in SCPL/DCPL layers, the retinal vascular density indices in SCPL/DCPL were lower in amblyopia eyes without statistically difference. Angio-OCT may be an effective way to evaluate the status of the choroidal and retinal vascular system in amblyopic children.