David Reiser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Reiser has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jürgen Knapp
University Hospital of Bern
1 shared publication - Lorenz Meuli
Department of Vascular Surgery, University Hospital Zürich, University of Zürich, 8091 Zürich, Switzerland
1 shared publication - Lorenz Theiler
Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
1 shared publication - Mario Tissi
Swiss Air-Ambulance, Rega (Rettungsflugwacht / Guarde Aérienne), Swiss Air-Rescue, Zurich, Switzerland
1 shared publication - Roland Albrecht
Division of Perioperative Intensive Care Medicine, Cantonal Hospital St. Gallen, St. Gallen, Switzerland
1 shared publication - Simon Rauch
Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy
1 shared publication
Latest Publications
- Open Access
- 25 July 2020
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 28 (1) , 1-9
Mechanical chest compression devices in the helicopter emergency medical service in Switzerland
Background: Over the past years, several emergency medical service providers have introduced mechanical chest compression devices (MCDs) in their protocols for cardiopulmonary resuscitation (CPR). Especially in helicopter emergency medical systems (HEMS), which have limitations regarding loading weight and space and typically operate in rural and remote areas, whether MCDs have benefits for patients is still unknown. The aim of this study was to evaluate the use of MCDs in a large Swiss HEMS system.Materials and methods: We conducted a retrospective observational study of all HEMS missions of Swiss Air rescue Rega between January 2014 and June 2016 with the use of an MCD (Autopulse®). Details of MCD use and patient outcome are reported from the medical operation journals and the hospitals’ discharge letters.Results: MCDs were used in 626 HEMS missions, and 590 patients (94%) could be included. 478 (81%) were primary missions and 112 (19%) were interhospital transfers. Forty-nine of the patients in primary missions were loaded under ongoing CPR with MCDs. Of the patients loaded after return of spontaneous circulation (ROSC), 20 (7%) experienced a second CA during the flight. In interhospital transfers, 102 (91%) only needed standby use of the MCD. Five (5%) patients were loaded into the helicopter with ongoing CPR. Five (5%) patients went into CA during flight and the MCD had to be activated. A shockable cardiac arrhythmia was the only factor significantly associated with better survival in resuscitation missions using MCD (OR 0.176, 95% confidence interval 0.084 to 0.372,p < 0.001).Conclusion: We conclude that equipping HEMS with MCDs may be beneficial, with non-trauma patients potentially benefitting more than trauma patients.
- 25 July 2020
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 28 (1) , 1-9
Open AccessMechanical chest compression devices in the helicopter emergency medical service in Switzerland
Background: Over the past years, several emergency medical service providers have introduced mechanical chest compression devices (MCDs) in their protocols for cardiopulmonary resuscitation (CPR). Especially in helicopter emergency medical systems (HEMS), which have limitations regarding loading weight and space and typically operate in rural and remote areas, whether MCDs have benefits for patients is still unknown. The aim of this study was to evaluate the use of MCDs in a large Swiss HEMS system.Materials and methods: We conducted a retrospective observational study of all HEMS missions of Swiss Air rescue Rega between January 2014 and June 2016 with the use of an MCD (Autopulse®). Details of MCD use and patient outcome are reported from the medical operation journals and the hospitals’ discharge letters.Results: MCDs were used in 626 HEMS missions, and 590 patients (94%) could be included. 478 (81%) were primary missions and 112 (19%) were interhospital transfers. Forty-nine of the patients in primary missions were loaded under ongoing CPR with MCDs. Of the patients loaded after return of spontaneous circulation (ROSC), 20 (7%) experienced a second CA during the flight. In interhospital transfers, 102 (91%) only needed standby use of the MCD. Five (5%) patients were loaded into the helicopter with ongoing CPR. Five (5%) patients went into CA during flight and the MCD had to be activated. A shockable cardiac arrhythmia was the only factor significantly associated with better survival in resuscitation missions using MCD (OR 0.176, 95% confidence interval 0.084 to 0.372,p < 0.001).Conclusion: We conclude that equipping HEMS with MCDs may be beneficial, with non-trauma patients potentially benefitting more than trauma patients.