SRSolaisamy Ramachandran

Solaisamy Ramachandran

*This is an algorithmically generated author record based on publicly available information.

Solaisamy Ramachandran has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Identification of operational parameter levels that optimize the production in solar stills with plain, corrugated, and compartmental basin

    by Sundararaj Joe Patrick Gnanaraj, Solaisamy Ramachandran

    Researchers integrate various operational parameters in the conventional type solar still to improve the distillate production. But maximum production can be obtained only when the optimum parameter levels which suit the solar still design are identified and incorporated. In this study, an attempt has been taken to identify the optimum level of four operational parameters—Mass of Heat Storage Material, Basin Water Depth, Basin Cover Thickness, and External Mirror Position, which suit well in plain basin, corrugated basin, and compartmental basin solar still. The parameter levels were combined as per L9 orthogonal array and the distillate production obtained under different combinations of operational parameter levels was analyzed using S/N ratio analysis, mean response method, analysis of variance, and regression analysis. The analysis revealed that the optimum mass of heat storage material was 16 kg in plain basin, 12 Kg in corrugated basin, and 10 Kg in compartmental basin still. The efficiency of corrugated basin and compartmental basin solar stills was maximum at a lower basin water depth of 15 mm and 10 mm respectively. But plain basin still efficiency was maximum at a higher basin water depth of 20 mm. The optimum basin cover thickness was 4 mm in all the solar stills, in spite of a difference in the structure of the basin. In the same way, the distillate production was maximum when the external mirrors were positioned on the two sloping sides of the solar still (east and west side). The expected production from the solar stills integrated with the optimum parameter levels was estimated using regression analysis and mean response method. The average distillate production which was 3304, 3493, and 3629 ml/m2.day in the modified (not with optimum parameter levels) plain basin, corrugated basin, and compartmental basin solar stills respectively, improved to 6414, 7153, and 7629 ml/m2.day respectively when they were modified with optimum parameter levels and the increase in production was 94 %, 105 %, and 110 % respectively.


  • Experimental Investigation of Solar based Liquid Desiccant Indirect Evaporative Cooling system

    by Anita A. Nene, Solaisamy Ramachandran

    Air conditioning by using vapor compression cycle is the most commonly used system although its operating energy cost is significantly high. Liquid desiccant dehumidifier with Indirect Evaporative Cooling (IEC) is another alternative suitable for hot and humid climatic conditions. The system works in two parts. In liquid desiccant dehumidifier section, moisture from humid air is removed and such air is passed through Indirect Evaporative Cooling system where air is cooled. An attempt was made to set up an experimental module with Scheffler solar concentrator to provide thermal energy for evaporation of liquid desiccant while a new type of polymer plate exchanger was used in evaporative cooling section instead of commonly used metal heat exchanger. The experimentation was carried using CaCl2 desiccant with varying flow rates between 2 and 4 l/min in dehumidifier section and reduction of relative humidity by 4 to 9% was achieved. As desiccant flow rate was increased, it resulted into higher carry over losses. Experimentally, it was found that for a flow rate of 3 l/min, the carry over losses are minimum. For this flow rate of desiccant, secondary-to-primary-air ratio of 0.8, water flow rate of 11 l/min, and air cooling by 4.7°C were achieved. Maximum wet bulb and dew point effectiveness were found to be 0.61 and 0.42, respectively, for secondary-to-primary-air ratio of 0.8. It could be concluded that a polymer plate heat exchanger-based system could be considered as efficient system than metal plate heat exchanger systems, because longer life, lighter weight, and low operating cost are the characteristics of polymers.


  • Integrated system of flat plate collector and Scheffler solar concentrator for enhancing thermal efficiency and steam generation rate

    by S. Ramachandran, Anita A. Nene, S. Suyambazhahan

    Scheffler concentrators are used for heating water and producing steam. Flat plate collectors are normally used for low temperature water heating. In this research work, the performances of a flat plate collector and a Scheffler solar concentrator were studied individually. After careful study of the results, an integrated system was developed to enhance the efficiency. Also, the experimental results were checked and validated through CFD. Flat plate collector shows higher efficiency in heating water upto 50∼ 600C and hence this feature is used for pre heating the water fed to the Scheffler concentrator. As a result, Scheffler concentrator’s thermal efficiency is improved significantly by about 6%. The steam generation rate of integrated system is also increased when compared to that of individual Scheffler concentrator. This study uses experimental works along with numerical methods to substantiate the results providing a good visualization of the receiver’s performance.


  • Studies on Scheffler solar concentrator to optimise thermal efficiency

    by S. Ramachandran, Anita A. Nene, S. Suyambazhahan

    Parametric analysis of Scheffler solar concentrator system is performed for improvement in thermal efficiency. Scheffler concentrator of size 2.7 m2 has been used for experimentation. In this system, receiver was installed at focus point. Cylindrical and Conical shape receivers each with 8-liter capacity was used for experimentation which serve a dual purpose of absorber as well as steam storage device. The thermal efficiencies with different receivers were calculated on the basis of parameters like shape of receiver, initial heating of inlet water, tilting angle of receiver and receiver with glass cover for steam pressures up to 3 bars. Cylindrical receiver has the maximum efficiency of 56.64% in case of initial heating of water (50oC) and conical receiver has the maximum efficiency of 76.04% in case of tilting position of receiver (45o) at 1 bar. Response surface method was used to optimize the thermal efficiency of receiver. The average solar radiation and mass flow rate of steam have significant effects on thermal efficiency. A general mathematical model for obtaining thermal efficiency has been developed for both types of receivers in terms of incident average solar radiation and mass flow rate of steam. The optimum predicted value of thermal efficiency is calculated from the general mathematical model and there is a good agreement found between the experimental and predicted results.


  • The effect of crack geometry on non-destructive fault detection of EN 8 and EN 47 cracked cantilever beam

    by V Khalkar, S Ramachandran

    Since long it has been observed that the size of the crack in structures increases with time, and finally, it may lead to its catastrophic failure. Hence, it is crucial to do the vibration study of cracked structures with regard to vibration-based crack detection and the classification of cracks. So far, vibration-based non-destructive testing method is applied to many spring steel cracked cantilever beams for its possible crack detection. However, the effect of various kinds of practical cracks, that is, V-shaped and U-shaped, on the applicability of these methods has been overlooked. To investigate this issue, artificially cracks are made on the cantilever beam. By free vibration analysis, the effect of crack geometry, crack depth, and crack location on natural frequency is investigated. The natural frequency results obtained from V-shaped and U-shaped models for the same crack configurations are compared with each other and it is revealed that the results are not much sensitive for the change of crack geometry. Hence, it is clear that free vibration-based crack detection method approximately predicts the crack parameters, that is, crack location and crack depth, in structures irrespective of the crack geometry. It is also found that for the same configuration, results of natural frequency are comparatively on the lower side for U-shaped crack models than V-shaped crack models. In this study, the natural frequency of each cracked case is computed by a theoretical method and numerical method and shows good agreement. Finally, it is also observed that structural integrity of a cracked cantilever beam is a function of crack location.


  • Open Access

    The effect of crack geometry on stiffness of spring steel cantilever beam

    by V Khalkar, S Ramachandran

    The survival of the crack in structures always keeps the structure away from performing well in applications due to significant changes in its dynamic response. It has been observed that in service the size of the crack in structures increases with time and finally it leads to its catastrophic failure. Hence it is crucial to do the vibration study of cracked beams in regard of free vibration-based crack detection and its crack classification. Until now the vibration-based nondestructive testing methods are applied to many spring steel cracked cantilever beams for its possible crack detection. However, the effect of various kinds of practical cracks, i.e. V-shaped, U-shaped and rectangular-shaped open cracks, on the applicability of these methods has been overlooked. In order to investigate this issue, artificially cracks are made on the cantilever beam. By free vibration analysis, the effect of crack geometry, crack depth, and crack location on the beam stiffness is investigated. In this study, the stiffness of each cracked case is computed by the deflection methods and vibration methods to ensure the strong validation. The stiffness results obtained from V-shaped, U-shaped and rectangular-shaped crack models for the same configuration are compared with each other and it is found that the results of the stiffness are comparatively more sensitive to U-shaped crack models. Through vibration study, it is found that spring steel structures are slightly sensitive to the change in crack geometries as long as the vibration characteristics are concerned. Hence, it is obvious that free vibration-based crack detection method can satisfactorily predict the location and depth of the crack in any spring steel structures irrespective of the crack geometries. Apart from this, it is also found that for the same configurations, EN 8 and EN 47 cracked cantilever beams give the identical structural integrity or structural stability property for all the cracked cases. Lastly, it is also found that as the crack depth increases by keeping the crack location constant, the stiffness of the beam decreases.