MTMohammad Mehdi Tehranchi

Mohammad Mehdi Tehranchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohammad Mehdi Tehranchi has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction: Design and manufacture of miniaturized fractal heater for optically pumped magnetometers

    by M. Soraya, Maliheh Ranjbaran, S. M. H. Khalkhali, M. M. Tehranchi

  • Design and manufacture of miniaturized fractal heater for optically pumped magnetometers

    by M. Soraya, Maliheh Ranjbaran, S. M. H. Khalkhali, M. M. Tehranchi

  • Induced in-plane magnetic anisotropy in Co/WS2 bilayer

    by Saeid Jannati, Ali Aftabi, Ali Rafiei, Mohammad Mehdi Tehranchi


  • Open Access

    Photo-induced anomalous Hall effect in ferromagnetic (Co)/transition metal dichalcogenide (WS 2 ) heterostructure

    by Saeid Jannati, Ali Aftabi, Ali Rafiei, Mohammad Mehdi Tehranchi

    The photo-induced Hall effect is shown in the Co/WS2 heterostructure. This heterostructure consists of a ferromagnetic metal layer that forms a Schottky junction to a transition metal dichalcogenide semiconductor layer. In this effect, under the magnetic field and light irradiation, the excited charge carriers from the WS2 layer diffuse into the Co layer and are driven by Lorentz forces, then creates a transverse voltage in the open circuit. This open circuit voltage is a function of light and magnetic field intensity. The photo-induced voltage is nonlinear and hysteretic with the applied magnetic field and is in good agreement with magneto-optical Kerr's hysteresis loops. The observed results can provide a new technique for optical and magnetic sensing applications. In addition, it proposed a new technique to reconstruct the in-plane magnetic hysteresis loop for metallic thin films.

  • Open Access

    Induced Magnetic Anisotropy in Co/WS 2 Bilayer

    by S. Jannati, A. Aftabi, A. Rafiei, M. M. Tehranchi

    Magnetic anisotropy plays an important role in ultrathin structures and two-dimensional materials and influences their magnetoresistance (MR) response. Here, the effects of the two-dimensional WS2 layer on the structural and magnetic properties of cobalt (Co) thin film are investigated in a Co/WS2 bilayer fabricated on Si (100) substrates. The Co layer grown on the WS2 layer formed a crystal structure whereas that individual Co isolated layer is amorphous. Both prepared samples show an out-of-plane easy axis while their in-plane anisotropy is different. The magnetic hysteresis loop and MR measurements show that there is an in-plane easy axis in the Co/WS2 bilayer due to the crystallinity formation of Co grown on WS2 which is not observed in Co isolated layer. Our results represent an interface control of anisotropy in two dimensional structures.


  • Open Access

    Ultrasensitive Magneto electric Sensor based on Galfenol/ AlN structure

    by M. Haghparast, M. M. Tehranchi, S. M. Hamidi

    Ultrasensitive magnetic field sensors based on magnetoelectric (ME) structures have many applications in bio-magnetic sensors and magnetoencephalography (MEG) scanners. Enhance the sensitivity, limit of detection and main frequency of these sensors need simulation process by accurate methods such as finite element method (FEM). To get good sensitivity and efficient benefit, we use a cantilever-type composite structures including galfenol alloy as a magnetostrictive layer and AlN as a piezoelectric layer. Galfenol is an alloy of iron and gallium and its \({\text{Fe}}_{\text{0.83}}{\text{Ga}}_{\text{0.17}}\) structure has a high magnetostriction coefficient and can be used as a thin film. According to the cantilever structure, the maximum bending of the structure is 20 \(\text{μm}\). The simulated sensor has a limit of detections of 1 \(\raisebox{1ex}{$\text{pT}$}\!\left/ \!\raisebox{-1ex}{$\sqrt{\text{Hz}}$}\right.\) and can measure an AC magnetic field of 1 pT. This sensor has the best performance in the bias DC magnetic field of 2.3 mT and resonance frequency of 2521.8 Hz and has a magnetoelectric coefficient of 4865 (\(\raisebox{1ex}{$\text{V}$}\!\left/ \!\raisebox{-1ex}{$\text{cm.Oe}$}\right.\)).

  • Open Access

    Myocardial Ischemia Detection by a Sensitive Pump-Probe Atomic Magnetometer

    by Amin Zamani, Maliheh Ranjbaran, Mohammad Mehdi Tehranchi, Seyedeh Mehri Hamidi, Seyed Mohammad Hosein Khalkhali

    Introduction: Magnetocardiography (MCG) based on optical atomic magnetometers has shown promise for detecting heart diseases accurately. Different methods were introduced to improve the sensitivity of detecting magnetic fields during cardiac activity. Methods: In this paper, an optical pump-probe magnetometer operated on the ground-state Hanle effect based on the zero-field level crossing technique was developed and the laser output signal was optimized in an unshielded environment. Then, the optical magnetometer was utilized to record the simulated MCG trace of different stages of myocardial ischemia. Results: The probe output light intensity followed the variation of cardiac magnetic field (MCG trace) generated by Helmholtz coil accurately. Conclusion: Based on the results, the feasibility of our highly sensitive optical magnetometer in tracing showed no change in the P-QRS-T waveform associated with ischemic heart disease (IHD), where P indicates atrial depolarization, QRS is responsible for ventricular depolarization, and T represents ventricular repolarization.


  • Open Access

    Magnetic generation of normal pseudo-spin polarization in disordered graphene

    by R. Baghran, M. M. Tehranchi, A. Phirouznia

    Spin to pseudo-spin conversion by which the non-equilibrium normal sublattice pseudo-spin polarization could be achieved by magnetic field has been proposed in graphene. Calculations have been performed within the Kubo approach for both pure and disordered graphene including vertex corrections of impurities. Results indicate that the normal magnetic field $$B_z$$ B z produces pseudo-spin polarization in graphene regardless of whether the contribution of vertex corrections has been taken into account or not. This is because of non-vanishing correlation between the $$\sigma _z$$ σ z and $$\tau _z$$ τ z provided by the co-existence of extrinsic Rashba and intrinsic spin–orbit interactions which combines normal spin and pseudo-spin. For the case of pure graphene, valley-symmetric spin to pseudo-spin response function is obtained. Meanwhile, by taking into account the vertex corrections of impurities the obtained response function is weakened by several orders of magnitude with non-identical contributions of different valleys. This valley-asymmetry originates from the inversion symmetry breaking generated by the scattering matrix. Finally, spin to pseudo-spin conversion in graphene could be realized as a practical technique for both generation and manipulation of normal sublattice pseudo-spin polarization by an accessible magnetic field in a easy way. This novel proposed effect not only offers the opportunity to selective manipulation of carrier densities on different sublattice but also could be employed in data transfer technology. The normal pseudo-spin polarization which manifests it self as electron population imbalance of different sublattices can be detected by optical spectroscopy measurements.


  • Pseudo-Edelstein effect in disordered silicene

    by Roham Baghran, Mohammad Mehdi Tehranchi, Arash Phirouznia

    The ‘ pseudo-Edelstein ’ effect by which charge current J x converts to pseudo-spin polarization, τ z , has been investigated theoretically for an infinite sheet of silicene. Calculations have been performed for conductor phase of silicene within the Dirac point approximation and in the presence of normally applied electric field. The latter conversion as an outcome of voltage-texture correlation in buckled silicene has been considered as ‘ pseudo-Edelstein ’response function. This response function have been calculated in the context of Kubo formalism in the presence of vertex corrections. It has been verified that the charge current results in normal pseudo-spin polarization i.e. sublattice population imbalance. According to obtained results in the presence of vertex corrections, ‘ pseudo-Edelstein ’ response function is weakened by several orders of magnitude with non-identical different valley contributions. In addition, extra small oscillations of obtained response function have been observed. Nevertheless, when the vertex corrections is off, the ‘ pseudo-Edelstein ’ response function is strengthened by several orders of magnitudes with the same different valleys contributions and the extra small oscillations of obtained response function are disappeared. These findings show that ‘ pseudo-Edelstein ’ response function is weakened by the intrinsic Rashba spin–orbit interaction which originally arises from buckling in silicene. As silicene has the lowest buckling among the graphene-like Dirac materials so it can be expected that ‘ pseudo-Edelstein ’ effect could be realized in a more pronounced manner in silicene. Obviously, this novel type of conversion not only can be employed in the future data transfer technology but also opens a sensible way to control of electrons populations electrically in realistic disordered silicene samples. The optical absorption spectroscopy could be taken as an efficient experimental plan of action by which the results of present work can be checked out.


  • Open Access

    Detection of magnetic tracers with Mx atomic magnetometer for application to blood velocimetry

    by Asieh Soheilian, Mohammad Mehdi Tehranchi, Maliheh Ranjbaran

    In the new generation of blood velocimeter systems, considerable attention has been paid to atomic magnetometers due to their high resolution and high sensitivity for detection of magnetic tracers. Passing the magnetic tracers adjacent to the atomic magnetometer produces a spike-like signal, the shape of which depends on the position of the tracer, as well as its velocity and orientation. The present study aimed to evaluate the effect of abrupt variations in the instantaneous velocity of the magnetic tracer on the magnetometer response compare to constant velocity. Modeling the magnetic tracer as a dipole moment indicated that the velocity dependence of the magnetic field and local magnetic field gradient associated with moving magnetic tracer cause the spike-like signal to go out of symmetry in the case of variable velocity. Based on the experimental results, any instantaneous variation in tracer velocity leads to shrinkage in the signal width. The behavior has been studied for both magnetic microwire with variable instantaneous velocity and magnetic droplets in stenosis artery phantom. In addition, the position of the tracer could be detected by following the shrinkage behavior which may occur on the peak, valley, or both. These advantageous outcomes can be applied for high sensitivity diagnosis of arterial stenosis.