Vibhor Kumar Bhardwaj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vibhor Kumar Bhardwaj has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Surita Maini
Sant Longowal Institute of Engineering and Technology
7 shared publicationsAmita Thakur
Dr. K. N. Modi Institute of Engineering & Technology
3 shared publications- Surita Maini
Department of Electrical and Instrumentation engineering, Sant Longowal Institute of Engineering and Technology, Longowal, Sangrur, India
2 shared publications Aanchal Agarwal
1 shared publication- Abhinav Sharma
Department of Electrical and Instrumentation engineering, Sant Longowal Institute of Engineering and Technology, Longowal, Sangrur, India
1 shared publication - Ajat Shatru Arora
Department of Electrical and Instrumentation Engineering, Sant Longowal Institute of Engineering and Technology, Punjab, 148106, India
1 shared publication
Latest Publications
- 8 February 2026
- Published by MECS Publisher in International Journal of Intelligent Systems and Applications
- Vol. 18 (1) , 75-89
Depth-guided Hybrid Attention Swin Transformer for Physics-guided Self-supervised Image Dehazing
Image dehazing is a critical preprocessing step in computer vision, enhancing visibility in degraded conditions. Conventional supervised methods often struggle with generalization and computational efficiency. This paper introduces a self-supervised image dehazing framework leveraging a depth-guided Swin Transformer with hybrid attention. The proposed hybrid attention explicitly integrates CNN-style channel and spatial attention with Swin Transformer window-based self-attention, enabling simultaneous local feature recalibration and global context aggregation. By integrating a pre-trained monocular depth estimation model and a Swin Transformer architecture with shifted window attention, our method efficiently models global context and preserves fine details. Here, depth is used as a relative structural prior rather than a metric quantity, enabling robust guidance without requiring haze-invariant depth estimation. Experimental results on synthetic and real-world benchmarks demonstrate superior performance, with a PSNR of 23.01 dB and SSIM of 0.879 on the RESIDE SOTS-indoor dataset, outperforming classical physics-based dehazing (DCP) and recent self-supervised approaches such as SLAD, achieving a PSNR gain of 2.52 dB over SLAD and 6.39 dB over DCP. Our approach also significantly improves object detection accuracy by 0.15 mAP@0.5 (+32.6%) under hazy conditions, and achieves near real-time inference (≈35 FPS at 256x256 resolution on a single GPU), confirming the practical utility of depth-guided features. Here, we show that our method achieves an SSIM of 0.879 on SOTS-Indoor, indicating strong structural and color fidelity for a self-supervised dehazing framework.
- 8 February 2026
- Published by MECS Publisher in International Journal of Intelligent Systems and Applications
- Vol. 18 (1) , 75-89
Depth-guided Hybrid Attention Swin Transformer for Physics-guided Self-supervised Image Dehazing
Image dehazing is a critical preprocessing step in computer vision, enhancing visibility in degraded conditions. Conventional supervised methods often struggle with generalization and computational efficiency. This paper introduces a self-supervised image dehazing framework leveraging a depth-guided Swin Transformer with hybrid attention. The proposed hybrid attention explicitly integrates CNN-style channel and spatial attention with Swin Transformer window-based self-attention, enabling simultaneous local feature recalibration and global context aggregation. By integrating a pre-trained monocular depth estimation model and a Swin Transformer architecture with shifted window attention, our method efficiently models global context and preserves fine details. Here, depth is used as a relative structural prior rather than a metric quantity, enabling robust guidance without requiring haze-invariant depth estimation. Experimental results on synthetic and real-world benchmarks demonstrate superior performance, with a PSNR of 23.01 dB and SSIM of 0.879 on the RESIDE SOTS-indoor dataset, outperforming classical physics-based dehazing (DCP) and recent self-supervised approaches such as SLAD, achieving a PSNR gain of 2.52 dB over SLAD and 6.39 dB over DCP. Our approach also significantly improves object detection accuracy by 0.15 mAP@0.5 (+32.6%) under hazy conditions, and achieves near real-time inference (≈35 FPS at 256x256 resolution on a single GPU), confirming the practical utility of depth-guided features. Here, we show that our method achieves an SSIM of 0.879 on SOTS-Indoor, indicating strong structural and color fidelity for a self-supervised dehazing framework.
- 30 October 2025
- Published by Springer Nature
- p. 205-214
Measurement of Refractive Index and Concentration of Liquid Sample Using Dual-Path SM-OFI
- 30 October 2025
- Published by Springer Nature
- p. 205-214
Measurement of Refractive Index and Concentration of Liquid Sample Using Dual-Path SM-OFI
- 15 June 2025
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 57 (6) , 1-19
Point-of-use refractometer using self-mixing optical feedback interferometry with predictive measurement for flowmetry applications
- 15 June 2025
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 57 (6) , 1-19
Point-of-use refractometer using self-mixing optical feedback interferometry with predictive measurement for flowmetry applications
- 1 April 2025
- Published by Springer Nature
- p. 335-344
Design of a Transimpedance Amplifier for Self-Mixing Optical Feedback System
- 1 April 2025
- Published by Springer Nature
- p. 335-344
Design of a Transimpedance Amplifier for Self-Mixing Optical Feedback System
- Top Cited Papers
- 15 March 2025
- Published by Springer Nature in Archives of Computational Methods in Engineering
- Vol. 32 (7) , 4303-4329
A Systematic Review on Machine Learning Intelligent Systems for Heart Disease Diagnosis
- 15 March 2025
- Published by Springer Nature in Archives of Computational Methods in Engineering
- Vol. 32 (7) , 4303-4329
Top Cited PapersA Systematic Review on Machine Learning Intelligent Systems for Heart Disease Diagnosis
- 9 August 2021
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 53 (8) , 1-17
Impact analysis of different trade-off parameters on coherent sensing applications of single-mode self-mixing optical feedback interferometry
- 9 August 2021
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 53 (8) , 1-17
Impact analysis of different trade-off parameters on coherent sensing applications of single-mode self-mixing optical feedback interferometry
- 1 December 2020
- Published by Elsevier in Optics Communications
- Vol. 476, 126330
Measurement of micro-harmonic vibration from optical feedback interferometry using wavelet trend analysis
- 1 December 2020
- Published by Elsevier in Optics Communications
- Vol. 476, 126330
Measurement of micro-harmonic vibration from optical feedback interferometry using wavelet trend analysis
- 25 March 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (10) , 3064-3072
Compact and self-aligned fluid refractometer based on the Doppler-induced self-mixing effect
The refractive index is one of the key parameters in non-invasive and label-free sensing applications. The past decade has witnessed various miniature optofluidic devices that offer several analytical functions with minuscule samples (picoliter or nanoliter) through the fusion of optics and microfluidic sciences. However, the realization of a compact, wide-range, and less-expensive refractometer is still a great challenge. In this paper, the authors have proposed a novel, to the best of our knowledge, self-mixing optical feedback interferometry (SM-OFI)-based refractometer that correlates the refractive index of a flowing liquid to the induced Doppler frequency shift. The proposed method was experimentally tested on the saline water and benzyl chloride and found close agreement with the literature results. The refractive indices of the saline water and benzyl chloride were measured to be 1.3346 and 1.54079, respectively, with a standard deviation of the order of 10 − 5 . The induced Doppler shift was linearly increased with the concentration of the liquid during the concentration profiling. Hence, the proposed method was also capable to profile the liquid concentration. The well-known compatibility and cost-effectiveness of the SM-OFI setup also support the proposed method for miniature applications. The compactness and the portability of the experimental setup also make it compatible in areas of application where the size of the analytical section is a decisive parameter, such as biosensors, particle manipulators, chemically active devices, lab-on-chip instruments, etc.
- 25 March 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (10) , 3064-3072
Compact and self-aligned fluid refractometer based on the Doppler-induced self-mixing effect
The refractive index is one of the key parameters in non-invasive and label-free sensing applications. The past decade has witnessed various miniature optofluidic devices that offer several analytical functions with minuscule samples (picoliter or nanoliter) through the fusion of optics and microfluidic sciences. However, the realization of a compact, wide-range, and less-expensive refractometer is still a great challenge. In this paper, the authors have proposed a novel, to the best of our knowledge, self-mixing optical feedback interferometry (SM-OFI)-based refractometer that correlates the refractive index of a flowing liquid to the induced Doppler frequency shift. The proposed method was experimentally tested on the saline water and benzyl chloride and found close agreement with the literature results. The refractive indices of the saline water and benzyl chloride were measured to be 1.3346 and 1.54079, respectively, with a standard deviation of the order of 10 − 5 . The induced Doppler shift was linearly increased with the concentration of the liquid during the concentration profiling. Hence, the proposed method was also capable to profile the liquid concentration. The well-known compatibility and cost-effectiveness of the SM-OFI setup also support the proposed method for miniature applications. The compactness and the portability of the experimental setup also make it compatible in areas of application where the size of the analytical section is a decisive parameter, such as biosensors, particle manipulators, chemically active devices, lab-on-chip instruments, etc.