Joan M. Nunez Do Rio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Joan M. Nunez Do Rio has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Christos Bergeles
School of Biomedical Engineering & Imaging Sciences, King’s College London, London, UK
4 shared publications - Paul Nderitu
King's Ophthalmology Research Unit (KORU), Section of Ophthalmology, Faculty of Life Sciences and Medicine King's College London London UK
2 shared publications - Sobha Sivaprasad
UCL Institute of Ophthalmology, UCL, London, UK
2 shared publications - Adam Michael Dubis
Institute of Ophthalmology, University College London, London EC1V 9EL, UK
1 shared publication - Akanksha Bagchi
NIHR Moorfields Biomedical Research Centre, Moorfields Eye Hospital, London EC1V 2PD, UK
1 shared publication - Charalampos Komninos
School of Biomedical Engineering & Imaging Sciences, King's College London, SE1 7EU, London, UK
1 shared publication
Latest Publications
- Open Access
- 20 December 2025
- Published by Springer Nature in Communications Medicine
- Vol. 6 (1)
Augmenting a prognostic deep learning system for referable diabetic retinopathy and maculopathy with synthetic retinal images
Background: Labelled data scarcity and class imbalance are common deep learning system (DLS) development challenges. We investigated if synthetic retinal images from a conditional cascaded diffusion model (CCDM) improves prognostic DLS (pDLS) performance for 2-year incident referable diabetic retinopathy or maculopathy (rDR/rM) prediction. Methods: Macula images from 72,559 eyes (September 2013 to December 2019) from the UK South-East London Diabetic Eye Screening Programme (SEL-DESP) formed the development dataset, whilst 9,071 eyes were used for internal testing. Images from 2,842 eyes from Birmingham DESP were used for external testing. Prognostic DLS were augmented with ×1, ×2, and ×4 additional synthetic positive cases (pDLS-G) and compared to unaugmented (pDLS-N) and ×1 positive-case resampled pDLS (pDLS-R) using the Area-Under-the Receiver Operating Characteristic curve (AUROC). Results: Here we show that CCDM generate realistic synthetic retinal images that are comparable to real images and demonstrate the utility of synthetic retinal images in augmenting the development of a pDLS. The internal and external test AUROC for the pDLS are 0.827 (95% CI: 0.794–0.861) and 0.756 (0.680–0.831), respectively. Augmentation with ×2 additional synthetic positive cases (pDLS-G ×2) significantly improves the internal test AUROC to 0.845 (95% CI: 0.812–0.877, p = 0.044) but does not improve the external test AUROC 0.717 (0.633–0.828, p = 0.243). Resampling positive real cases alone does not improve pDLS-R performance. Conclusions: Augmenting pDLS with synthetic retinal images significantly improves pDLS performance on internal testing but not external testing suggesting further research is required to enhance the generalisability of synthetic retinal image augmentation.
- 20 December 2025
- Published by Springer Nature in Communications Medicine
- Vol. 6 (1)
Open AccessAugmenting a prognostic deep learning system for referable diabetic retinopathy and maculopathy with synthetic retinal images
Background: Labelled data scarcity and class imbalance are common deep learning system (DLS) development challenges. We investigated if synthetic retinal images from a conditional cascaded diffusion model (CCDM) improves prognostic DLS (pDLS) performance for 2-year incident referable diabetic retinopathy or maculopathy (rDR/rM) prediction. Methods: Macula images from 72,559 eyes (September 2013 to December 2019) from the UK South-East London Diabetic Eye Screening Programme (SEL-DESP) formed the development dataset, whilst 9,071 eyes were used for internal testing. Images from 2,842 eyes from Birmingham DESP were used for external testing. Prognostic DLS were augmented with ×1, ×2, and ×4 additional synthetic positive cases (pDLS-G) and compared to unaugmented (pDLS-N) and ×1 positive-case resampled pDLS (pDLS-R) using the Area-Under-the Receiver Operating Characteristic curve (AUROC). Results: Here we show that CCDM generate realistic synthetic retinal images that are comparable to real images and demonstrate the utility of synthetic retinal images in augmenting the development of a pDLS. The internal and external test AUROC for the pDLS are 0.827 (95% CI: 0.794–0.861) and 0.756 (0.680–0.831), respectively. Augmentation with ×2 additional synthetic positive cases (pDLS-G ×2) significantly improves the internal test AUROC to 0.845 (95% CI: 0.812–0.877, p = 0.044) but does not improve the external test AUROC 0.717 (0.633–0.828, p = 0.243). Resampling positive real cases alone does not improve pDLS-R performance. Conclusions: Augmenting pDLS with synthetic retinal images significantly improves pDLS performance on internal testing but not external testing suggesting further research is required to enhance the generalisability of synthetic retinal image augmentation.
- Open Access
- 10 September 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 197 (Pt B) , 111030
RetiGen: Framework leveraging domain generalization and test-time adaptation for multi-view retinal diagnostics
- 10 September 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 197 (Pt B) , 111030
Open AccessRetiGen: Framework leveraging domain generalization and test-time adaptation for multi-view retinal diagnostics
- Open Access
- 26 January 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (3) , 614
Evaluating a Deep Learning Diabetic Retinopathy Grading System Developed on Mydriatic Retinal Images When Applied to Non-Mydriatic Community Screening
Artificial Intelligence has showcased clear capabilities to automatically grade diabetic retinopathy (DR) on mydriatic retinal images captured by clinical experts on fixed table-top retinal cameras within hospital settings. However, in many low- and middle-income countries, screening for DR revolves around minimally trained field workers using handheld non-mydriatic cameras in community settings. This prospective study evaluated the diagnostic accuracy of a deep learning algorithm developed using mydriatic retinal images by the Singapore Eye Research Institute, commercially available as Zeiss VISUHEALTH-AI DR, on images captured by field workers on a Zeiss Visuscout® 100 non-mydriatic handheld camera from people with diabetes in a house-to-house cross-sectional study across 20 regions in India. A total of 20,489 patient eyes from 11,199 patients were used to evaluate algorithm performance in identifying referable DR, non-referable DR, and gradability. For each category, the algorithm achieved precision values of 29.60 (95% CI 27.40, 31.88), 92.56 (92.13, 92.97), and 58.58 (56.97, 60.19), recall values of 62.69 (59.17, 66.12), 85.65 (85.11, 86.18), and 65.06 (63.40, 66.69), and F-score values of 40.22 (38.25, 42.21), 88.97 (88.62, 89.31), and 61.65 (60.50, 62.80), respectively. Model performance reached 91.22 (90.79, 91.64) sensitivity and 65.06 (63.40, 66.69) specificity at detecting gradability and 72.08 (70.68, 73.46) sensitivity and 85.65 (85.11, 86.18) specificity for the detection of all referable eyes. Algorithm accuracy is dependent on the quality of acquired retinal images, and this is a major limiting step for its global implementation in community non-mydriatic DR screening using handheld cameras. This study highlights the need to develop and train deep learning-based screening tools in such conditions before implementation.
- 26 January 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (3) , 614
Open AccessEvaluating a Deep Learning Diabetic Retinopathy Grading System Developed on Mydriatic Retinal Images When Applied to Non-Mydriatic Community Screening
Artificial Intelligence has showcased clear capabilities to automatically grade diabetic retinopathy (DR) on mydriatic retinal images captured by clinical experts on fixed table-top retinal cameras within hospital settings. However, in many low- and middle-income countries, screening for DR revolves around minimally trained field workers using handheld non-mydriatic cameras in community settings. This prospective study evaluated the diagnostic accuracy of a deep learning algorithm developed using mydriatic retinal images by the Singapore Eye Research Institute, commercially available as Zeiss VISUHEALTH-AI DR, on images captured by field workers on a Zeiss Visuscout® 100 non-mydriatic handheld camera from people with diabetes in a house-to-house cross-sectional study across 20 regions in India. A total of 20,489 patient eyes from 11,199 patients were used to evaluate algorithm performance in identifying referable DR, non-referable DR, and gradability. For each category, the algorithm achieved precision values of 29.60 (95% CI 27.40, 31.88), 92.56 (92.13, 92.97), and 58.58 (56.97, 60.19), recall values of 62.69 (59.17, 66.12), 85.65 (85.11, 86.18), and 65.06 (63.40, 66.69), and F-score values of 40.22 (38.25, 42.21), 88.97 (88.62, 89.31), and 61.65 (60.50, 62.80), respectively. Model performance reached 91.22 (90.79, 91.64) sensitivity and 65.06 (63.40, 66.69) specificity at detecting gradability and 72.08 (70.68, 73.46) sensitivity and 85.65 (85.11, 86.18) specificity for the detection of all referable eyes. Algorithm accuracy is dependent on the quality of acquired retinal images, and this is a major limiting step for its global implementation in community non-mydriatic DR screening using handheld cameras. This study highlights the need to develop and train deep learning-based screening tools in such conditions before implementation.
- Open Access
- 6 August 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (8) , 2537
Deep Learning-Based Segmentation and Quantification of Retinal Capillary Non-Perfusion on Ultra-Wide-Field Retinal Fluorescein Angiography
Reliable outcome measures are required for clinical trials investigating novel agents for preventing progression of capillary non-perfusion (CNP) in retinal vascular diseases. Currently, accurate quantification of topographical distribution of CNP on ultrawide field fluorescein angiography (UWF-FA) by retinal experts is subjective and lack standardisation. A U-net style network was trained to extract a dense segmentation of CNP from a newly created dataset of 75 UWF-FA images. A subset of 20 images was also segmented by a second expert grader for inter-grader reliability evaluation. Further, a circular grid centred on the FAZ was used to provide standardised CNP distribution analysis. The model for dense segmentation was five-fold cross-validated achieving area under the receiving operating characteristic of 0.82 (0.03) and area under precision-recall curve 0.73 (0.05). Inter-grader assessment on the 20 image subset achieves: precision 59.34 (10.92), recall 76.99 (12.5), and dice similarity coefficient (DSC) 65.51 (4.91), and the centred operating point of the automated model reached: precision 64.41 (13.66), recall 70.02 (16.2), and DSC 66.09 (13.32). Agreement of CNP grid assessment reached: Kappa 0.55 (0.03), perfused intraclass correlation (ICC) 0.89 (0.77, 0.93), non-perfused ICC 0.86 (0.73, 0.92), inter-grader agreement of CNP grid assessment values are Kappa 0.43 (0.03), perfused ICC 0.70 (0.48, 0.83), non-perfused ICC 0.71 (0.48, 0.83). Automated dense segmentation of CNP in UWF-FA images achieves performance levels comparable to inter-grader agreement values. A grid placed on the deep learning-based automatic segmentation of CNP generates a reliable and quantifiable method of measurement of CNP, to overcome the subjectivity of human graders.
- 6 August 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (8) , 2537
Open AccessDeep Learning-Based Segmentation and Quantification of Retinal Capillary Non-Perfusion on Ultra-Wide-Field Retinal Fluorescein Angiography
Reliable outcome measures are required for clinical trials investigating novel agents for preventing progression of capillary non-perfusion (CNP) in retinal vascular diseases. Currently, accurate quantification of topographical distribution of CNP on ultrawide field fluorescein angiography (UWF-FA) by retinal experts is subjective and lack standardisation. A U-net style network was trained to extract a dense segmentation of CNP from a newly created dataset of 75 UWF-FA images. A subset of 20 images was also segmented by a second expert grader for inter-grader reliability evaluation. Further, a circular grid centred on the FAZ was used to provide standardised CNP distribution analysis. The model for dense segmentation was five-fold cross-validated achieving area under the receiving operating characteristic of 0.82 (0.03) and area under precision-recall curve 0.73 (0.05). Inter-grader assessment on the 20 image subset achieves: precision 59.34 (10.92), recall 76.99 (12.5), and dice similarity coefficient (DSC) 65.51 (4.91), and the centred operating point of the automated model reached: precision 64.41 (13.66), recall 70.02 (16.2), and DSC 66.09 (13.32). Agreement of CNP grid assessment reached: Kappa 0.55 (0.03), perfused intraclass correlation (ICC) 0.89 (0.77, 0.93), non-perfused ICC 0.86 (0.73, 0.92), inter-grader agreement of CNP grid assessment values are Kappa 0.43 (0.03), perfused ICC 0.70 (0.48, 0.83), non-perfused ICC 0.71 (0.48, 0.83). Automated dense segmentation of CNP in UWF-FA images achieves performance levels comparable to inter-grader agreement values. A grid placed on the deep learning-based automatic segmentation of CNP generates a reliable and quantifiable method of measurement of CNP, to overcome the subjectivity of human graders.