FNFadi Najem

Fadi Najem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fadi Najem has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Abdullah M Jamos

    Department of Hearing and Speech, University of Kansas Medical Center, Kansas City, Kansas

    1 shared publication
  • Art Mallinson

    Division of Otolaryngology, Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z4, Canada

    1 shared publication
  • Basem Marie

    Department of Audiology and Speech Pathology, Al-Ahliyya Amman University, Amman, Jordan

    1 shared publication
  • Clifford Franklin

    Department of Audiology and Speech Pathology, University of Arkansas at Little Rock, Little Rock, Arkansas

    1 shared publication
  • Georges Dumas

    EA 3450 DevAH, Development, Adaptation and Handicap, Faculty of Medicine and UFR STAPS, University of Lorraine, Villers-lès-Nancy, France

    1 shared publication
  • Georges Dumas

    Research Unit DevAH—Development, Adaptation and Handicap, Faculty of Medicine, University of Lorraine, 54500 Vandoeuvre-lès-Nancy, France

    1 shared publication

Latest Publications

  • Effect of Abstract Phonemic Complexity on Mismatch Negativity (MMN) Amplitude

    by Fadi Najem, Letitia White-Minnis, Saravanan Elangovan, Clifford Franklin, Abdullah M Jamos

    Purpose Mismatch negativity (MMN) reflects a preperceptual neurophysiological response that is generated subconsciously due to the interruption of a memory trace of ongoing sensory events in the environment. It has been widely used by researchers to understand complex perceptual mechanisms. Furthermore, it has been recommended as an objective tool to investigate disorders related to auditory cognition in hearing aid and cochlear implant users. Many researchers suggest that utilizing a larger acoustic difference between standard and deviant stimuli within the oddball paradigm will lead to a more robust MMN response. The purpose of the present study is to examine if increasing the abstract phonemic contrast between standard and deviant stimuli in the oddball paradigm leads to a more robust MMN response. Methods Fourteen young female adults participated in the present study. To ensure that the MMN response was elicited by phonemic and not acoustic differences in the stimuli, a one-to-many ratio was created for the abstract phonemic features while controlling the acoustic features when designing the oddball paradigm as described by Phillips et al. (2000). MMN amplitude was measured at the Cz and Fz electrodes in two conditions, with two trials in each condition. In condition 1, the standards and deviants differed by one distinctive feature: voicing in trial 1 (/t/ was standard and /d/ was deviant) and place of articulation in trial 2 (/b/ was standard and /d/ was deviant). In condition 2, the standards and deviants differed across two distinctive features: voicing and place of articulation. In trial 1, /p/ was standard and /d/ was deviant; in trial 2, /d/ was standard and /p/ was deviant. Results MMN amplitudes elicited by two distinctive features were significantly larger than MMN amplitudes elicited by one distinctive feature (p < 0.001). Trials 1 and 2 in each condition showed no statistical difference, and they were repeatable and highly correlated. Recordings from the Cz and Fz electrodes showed no statistical difference and were highly correlated and similar in morphology. Conclusion It is known in the literature that increasing acoustic complexity elicits a more robust MMN. The present study showed that this assumption can be extended to abstract phonemic complexity. Increasing the phonemic complexity by utilizing more distinctive features in the oddball paradigm increased the amplitude and robustness of the MMN.


  • Investigating the Utility of a Compact Loudspeaker Array for Audiometric Testing

    by Patrick M. Zurek, Richard L. Freyman, Fadi Najem

    Purpose: This project addressed the uses of a loudspeaker array for audiometric measurements. It sought to evaluate a prototype compact array in terms of the reliability of test results across sound booths. Method: A seven-loudspeaker array was developed to deliver sounds from −60° to +60° on an arc with a radius of 0.5 m. The system was equipped with a head position sensing system to maintain the listener's head near the optimal test position. Three array systems were distributed to each of the two test sites for within-subject assessments of booth equivalence on tests of sound localization, speech reception in noise, and threshold detection. A total of 36 subjects participated, 18 at each test site. Results: Results showed excellent interbooth consistency on tests of sound localization using speech and noise signals, including conditions in which one or both ears were covered with a muff. Booth consistency was also excellent on sound field threshold measurements for detecting quasi-diffuse noise bands. Nonequivalence was observed in some cases of speech-in-noise tests, particularly with a small one-person booth. Acoustic analyses of in situ loudspeaker responses indicated that some of the nonequivalent comparisons on speech-in-noise tests could be traced to the effects of reflections. Conclusions: Overall, the results demonstrate the utility and reliability of a compact array for the assessment of localization ability, speech reception in noise, and sound field thresholds. However, the results indicate that researchers and clinicians should be aware of the reflection effects that can influence the results of sound field tests in which signal and noise levels from separate loudspeakers are critical.


  • Open Access

    Correlation of SVINT and Sensory Organization Test in Children with Hearing Loss

    by Solara Sinno, Fadi Najem, Georges Dumas, Kim Smith Abouchacra, Art Mallinson, Philippe Perrin

    Objective: The skull vibration-induced-nystagmus test (SVINT) is a noninvasive and effective screening tool for the function of the otolith and canal structures in children. It can instantaneously assess vestibular asymmetry. This study aimed to analyze the SVINT results of healthy children vs. children with hearing loss (HL) and to correlate it with sensory organization test (SOT) results as a functional balance evaluation tool. Design: This case-controlled study compared the results of SVINT to the results of the SOT of the computerized dynamic posturography (CDP) in a control group of 120 healthy normal-hearing children (i.e., NH group) vs. hearing loss (HL) group of 60 children, including 30 children with hearing aids (HAs) and 30 children with a unilateral cochlear implant (CI). The SVINT results were compared to the caloric test (CaT) and video head impulse test (vHIT) and associated with SOT scores. Results: Thirty-one children in the HL group had normal SVINT and normal SOT results. A total of 21 children in the HL group had SVINT-negative and abnormal results in the SOT (possibly due to bilateral vestibular loss (BVL)). Eight children in the HL group had positive SVINT and abnormal SOT results. However, none of the children had only positive SVINT with normal SOT findings. Moreover, 52% of children had a normal result on both the SOT and CaT, whereas 27% had abnormal results on both tests (17% bilateral weakness and 10% unilateral), and 22% had the only result of the SOT suggesting a functional abnormality. Similarly, when associating the result to vHIT, 51% had normal results on both tests, and 25% had abnormal results (13% bilateral and 12% unilateral weakness). Conclusions: SVINT findings can be correlated with SOT findings in the case of the unilateral vestibular lesion (UVL), which adds a diagnostic value in these pediatric cases but may differ in the case of the bilateral vestibular lesion (BVL). However, SVINT findings need to be cautiously interpreted in light of other test findings such as the SOT, CaT, and vHIT.


  • Phonemically Balanced Arabic Monosyllabic Word Lists for Speech Audiometry Testing in Jordan

    by Fadi Jamil Najem, Basem Marie

    Background Many of the Arabic monosyllabic word lists that are currently available in the literature have some limitations and drawbacks. Some of these available lists include word structures that are not consonant-nucleus-consonant (CNC) such as cluster and disyllabic word structures. Other lists have poor phonetic or phonemic distribution balance and do not represent some phoneme appropriately in each list. Purpose The purpose of the present study is to create and validate eight digitally recorded lists of phonemically balanced CNC words that represent all Arabic phonemes, to be used in the evaluation of word recognition score (WRS) of Jordanian Arabic-speaking adults. These lists should be easily adapted by other Arab countries because of the simplicity of the words, and the balanced inclusion of all the Arabic phonemes. Research Design The present study is a prospective cross-sectional study. Study Sample Thirty-one (23 females, 8 males) normal hearing and healthy young adults (18‐29 years old) participated in the present study. All participants were native speakers of Jordanian Arabic and had no history of ear disease or surgery. Lists The authors created all possible combinations of Arabic CNC words, and then created eight phonemically balanced lists with 26 words in each list. Each consonant was presented only once at the beginning of a word and once at the end of a word in each list. The lists were recorded using a Jordanian male voice and the intensity of each word was digitally calibrated. Data Collection and Analysis The pure tone average (PTA) of 0.5, 1, 2, 4 kHz was calculated for each participant, and the WRS was obtained for each intensity level in the range of ‐10 to 55 dB SL (ref. PTA) in 5 dB steps. Results No significant difference between right and left ear WRS was found at any intensity level. The WRSs from both ears were averaged and used in the repeated measure analysis of variance. Performance-intensity functions for all the lists showed some small but statistically significant differences between lists. However, none of these differences were clinically significant (Conclusion The present study provides eight lists of recorded and calibrated CNC word lists. The obtained PI functions showed that these lists are suitable for Jordanian Arabic speaking adults. These lists can be easily generalized to other Arab countries after conducting the required follow-up research.


  • Normative Values of Saccades and Smooth Pursuit in Children Aged 5 to 17 Years

    by Solara Sinno, Fadi Najem, Kim Smith Abouchacra, Philippe Perrin, Georges Dumas

    Background Pediatric oculomotor function can be evaluated via videonystagmography. Adult normative data for saccades and smooth pursuit tests cannot be used as a benchmark for pediatric patients because children's peripheral and central systems continue to mature throughout adolescence. Purpose The purpose of this study was to establish normative data for saccade and smooth pursuit tests that can be used clinically in the assessment of vestibular and neurological disorders in children, and to investigate the effect of age and eye movement direction (left/right) on tests parameters. Research Design The present study is prospective cross-sectional study. Study Sample A total of 120 healthy children were recruited and equally distributed according to age and gender to each of the following groups: 5-8, 9-11, 12-14, and 15-17 years old. Participants had to pass a comprehensive otological and neurological assessment prior to inclusion in the study. Each subject underwent saccade and smooth pursuit testing. Data Collection and Analysis Saccade latency, velocity and accuracy/precision, and smooth pursuit gain were analyzed across groups using a two-way repeated measure multivariate analysis of variance (MANOVA). Results Saccadic latency was longer in the youngest group aged 5-8 years old (305 ± 48 msec) in comparison to children aged 9-11 years old (276 ± 22 msec) (P = 0.017), 12-14 years old (252 ± 34 msec) (P = 0.001) adolescents 15-17 years (256 ± 33 msec) (P = 0.001). Age did not affect the results of saccadic velocity and accuracy/precision. Saccade parameters (latency, velocity, accuracy/ precision) were not affected by oculomotor direction (left vs. right). Smooth pursuit gain increased from 0.63 in children aged 5-8 years old to 0.85 in children aged 15-17 years (P = 0.0001). The percentage of gain asymmetry was significantly different in the youngest two groups. Conclusion Saccade latency decreased as age increased. Smooth pursuit gains increased with increased age. Saccade velocity and accuracy/precision did not change significantly from ages 5-8 to 15-17 years of age. These data provide normative values for pediatric oculomotor evaluation and suggest that saccade and pursuit pathways may mature at different rates.