Arnd Steinbrück
Arnd Steinbrück has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Grimberg
German Arthroplasty Registry (EPRD Deutsche Endoprothesenregister GmbH), Berlin, Germany
3 shared publications Alexander Grimberg
EPRD Deutsche Endoprothesenregister gGmbH, Berlin, Deutschland
2 shared publicationsCarsten Perka
Centrum für Muskuloskeletale Chirurgie (CMSC), Charité – Universitätsmedizin Berlin, Berlin, Deutschland
2 shared publications- Dominik Szymski
Department of Trauma Surgery University Medical Centre Regensburg Regensburg Germany
2 shared publications - Markus Rupp
Department of Trauma, Hand and Reconstructive Surgery, University Hospital Giessen, Justus Liebig University of Giessen, 35385 Giessen, Germany
2 shared publications - Nike Walter
Department for Psychosomatic Medicine, University Hospital Regensburg, Regensburg, Germany
2 shared publications
Latest Publications
- Open Access
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (3)
Antibiotic-Loaded Bone Cement and Risk of Infection After Knee Arthroplasty in High-Risk Patients
Background: The use of antibiotic-loaded bone cement (ALBC) in primary total knee arthroplasty (TKA) is debated. Some argue that ALBC might only be justified in high-risk patients. This study assessed the effectiveness of ALBC vs. plain bone cement (PBC) in reducing risk of revision for periprosthetic joint infection (PJI) in TKA patients considered to have a high risk of infection. Methods: Cohort study of primary TKAs in 11 national or regional arthroplasty registries from 2010 to 2020. The 1-year risk of revision for PJI in TKAs with ALBC vs. PBC among patients with high American Society of Anesthesiologists (ASA) classification, body mass index (BMI), and/or diabetes was compared. Cumulative percent revision (1 minus Kaplan-Meier) based on 685,818 TKAs and Cox regression analyses (adjusted Hazard Rate Ratios [aHRRs]) were performed for TKAs with ALBC (reference) vs. PBC restricted to the following high-risk subgroups of patients: (1) ASA ≥3 (n = 335,612 vs. 35,997), (2) BMI ≥35 (n = 278,927 vs. 24,737), (3) ASA ≥3 and BMI ≥35 (n = 99,407 vs. 11,407), (4) diabetes (n = 38,341 vs. 21,838), and (5) ASA ≥3, BMI ≥35, and diabetes (n = 3,347 vs. 4,261). Advanced distributed meta-analyses were performed to combine all aggregate data and assess 1-year risk of revision for PJI. Results: Each registry reported a 1-year cumulative percent revision of ≤1.6% for PJI following TKAs both for ALBC and PBC in all high-risk subgroups. Similar 1-year risks of revision for PJI were found in TKAs with ALBC (reference) and PBC among patients with ASA ≥3 (aHRR: 1.09; 95% CI, 0.90-1.31); BMI ≥35 (1.06; 0.54-2.12); ASA ≥3 and BMI ≥35 (1.12; 0.83-1.50); diabetes (0.95; 0.74-1.20); and ASA ≥3, BMI ≥35, and diabetes (1.40; 0.86-2.29). Conclusions and Relevance: Similar 1-year revision risk of PJI was found for TKAs with ALBC vs. PBC in high-risk patients. Confirmation of the efficacy of ALBC in high-risk TKA patients needs to be evaluated in clinical trials. Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (3)
Open AccessAntibiotic-Loaded Bone Cement and Risk of Infection After Knee Arthroplasty in High-Risk Patients
Background: The use of antibiotic-loaded bone cement (ALBC) in primary total knee arthroplasty (TKA) is debated. Some argue that ALBC might only be justified in high-risk patients. This study assessed the effectiveness of ALBC vs. plain bone cement (PBC) in reducing risk of revision for periprosthetic joint infection (PJI) in TKA patients considered to have a high risk of infection. Methods: Cohort study of primary TKAs in 11 national or regional arthroplasty registries from 2010 to 2020. The 1-year risk of revision for PJI in TKAs with ALBC vs. PBC among patients with high American Society of Anesthesiologists (ASA) classification, body mass index (BMI), and/or diabetes was compared. Cumulative percent revision (1 minus Kaplan-Meier) based on 685,818 TKAs and Cox regression analyses (adjusted Hazard Rate Ratios [aHRRs]) were performed for TKAs with ALBC (reference) vs. PBC restricted to the following high-risk subgroups of patients: (1) ASA ≥3 (n = 335,612 vs. 35,997), (2) BMI ≥35 (n = 278,927 vs. 24,737), (3) ASA ≥3 and BMI ≥35 (n = 99,407 vs. 11,407), (4) diabetes (n = 38,341 vs. 21,838), and (5) ASA ≥3, BMI ≥35, and diabetes (n = 3,347 vs. 4,261). Advanced distributed meta-analyses were performed to combine all aggregate data and assess 1-year risk of revision for PJI. Results: Each registry reported a 1-year cumulative percent revision of ≤1.6% for PJI following TKAs both for ALBC and PBC in all high-risk subgroups. Similar 1-year risks of revision for PJI were found in TKAs with ALBC (reference) and PBC among patients with ASA ≥3 (aHRR: 1.09; 95% CI, 0.90-1.31); BMI ≥35 (1.06; 0.54-2.12); ASA ≥3 and BMI ≥35 (1.12; 0.83-1.50); diabetes (0.95; 0.74-1.20); and ASA ≥3, BMI ≥35, and diabetes (1.40; 0.86-2.29). Conclusions and Relevance: Similar 1-year revision risk of PJI was found for TKAs with ALBC vs. PBC in high-risk patients. Confirmation of the efficacy of ALBC in high-risk TKA patients needs to be evaluated in clinical trials. Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.
- 13 February 2025
- Published by Springer Nature in Die Orthopädie
- Vol. 54 (3) , 185-189
EPRD aktuell – wissenschaftliche Entwicklung und gesundheitspolitische Einordnung
Zusammenfassung Hintergrund Das Endoprothesenregister Deutschland (EPRD) hat sich nach seiner Gründung 2010 durch die Deutsche Gesellschaft für Orthopädie und Orthopädische Chirurgie (DGOOC) und dem Aufbau gemeinsam mit der Vertretung der Industrie (Bundesverband Medizintechnologie e. V. [BVMed]) und der Krankenkassen (AOK-Bundesverband eGbR, Verband der Ersatzkassen e. V. [vdek]) rasant bezüglich Größe und Qualität der Ergebnisse weiterentwickelt. Inzwischen ist es mit über 3 Mio. erfassten Datensätzen von Hüft- und Knieprothesen das weltweit drittgrößte Register für Endoprothetik. Die Produktdatenbank des EPRD und National Joint Registry (NJR) wird zum weltweiten Standard. 2023 war ein Rekordjahr bezüglich erfasster Operationen und wissenschaftlicher Publikationen. Die Ergebnisse des EPRD analysieren und beeinflussen zunehmend den klinischen Alltag in der Hüft- und Knieendoprothetik in Deutschland. Ausblick Ab 2025 können alle EPRD-Kliniken den Oxford Hip und Oxford Knee Score kostenfrei für ihre Patienten als „patient reported outcome measures“ (PROM) nutzen. 2025 werden die Erfassungsparameter um die operativen Zugänge an der Hüfte, die Navigation und Robotik am Kniegelenk sowie ein optionales Infektionsmodul erweitert. 2026 wird die freiwillige Erfassung des Operateurs möglich sein. Das EPRD und das Implantateregister Deutschland (IRD) werden ab 2025 voraussichtlich parallel bestehen, eine Kooperation wird unverändert angestrebt. Die Datenerfassung soll möglichst schlank ohne doppelte Dateneingabe ermöglicht werden. Das EPRD wird jedoch unabhängig vom IRD mit seiner über 12-jährigen Erfahrung und über 3 Mio. Datensätzen weiterarbeiten und die Kliniken und Fachkreise auch zukünftig mit seinen Analysen und Publikationen versorgen.
- 13 February 2025
- Published by Springer Nature in Die Orthopädie
- Vol. 54 (3) , 185-189
EPRD aktuell – wissenschaftliche Entwicklung und gesundheitspolitische Einordnung
Zusammenfassung Hintergrund Das Endoprothesenregister Deutschland (EPRD) hat sich nach seiner Gründung 2010 durch die Deutsche Gesellschaft für Orthopädie und Orthopädische Chirurgie (DGOOC) und dem Aufbau gemeinsam mit der Vertretung der Industrie (Bundesverband Medizintechnologie e. V. [BVMed]) und der Krankenkassen (AOK-Bundesverband eGbR, Verband der Ersatzkassen e. V. [vdek]) rasant bezüglich Größe und Qualität der Ergebnisse weiterentwickelt. Inzwischen ist es mit über 3 Mio. erfassten Datensätzen von Hüft- und Knieprothesen das weltweit drittgrößte Register für Endoprothetik. Die Produktdatenbank des EPRD und National Joint Registry (NJR) wird zum weltweiten Standard. 2023 war ein Rekordjahr bezüglich erfasster Operationen und wissenschaftlicher Publikationen. Die Ergebnisse des EPRD analysieren und beeinflussen zunehmend den klinischen Alltag in der Hüft- und Knieendoprothetik in Deutschland. Ausblick Ab 2025 können alle EPRD-Kliniken den Oxford Hip und Oxford Knee Score kostenfrei für ihre Patienten als „patient reported outcome measures“ (PROM) nutzen. 2025 werden die Erfassungsparameter um die operativen Zugänge an der Hüfte, die Navigation und Robotik am Kniegelenk sowie ein optionales Infektionsmodul erweitert. 2026 wird die freiwillige Erfassung des Operateurs möglich sein. Das EPRD und das Implantateregister Deutschland (IRD) werden ab 2025 voraussichtlich parallel bestehen, eine Kooperation wird unverändert angestrebt. Die Datenerfassung soll möglichst schlank ohne doppelte Dateneingabe ermöglicht werden. Das EPRD wird jedoch unabhängig vom IRD mit seiner über 12-jährigen Erfahrung und über 3 Mio. Datensätzen weiterarbeiten und die Kliniken und Fachkreise auch zukünftig mit seinen Analysen und Publikationen versorgen.
- Open Access
- 16 May 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 12 (5) , 331-338
Infection after intracapsular femoral neck fracture – does antibiotic-loaded bone cement reduce infection risk after hemiarthroplasty and total hip arthroplasty?
Aims: The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture.Methods: Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching.Results: Overall in 13,612 cases of intracapsular femoral neck fracture, 9,110 (66.9%) HAs and 4,502 (33.1%) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared with uncemented fixated prosthesis (p = 0.013). In patients with THA no statistical difference between cemented and uncemented prosthesis was registered, however after one year 2.4% of infections were detected in uncemented and 2.1% in cemented THA. In the subpopulation of HA after one year, 1.9% of infections were registered in cemented and 2.8% in uncemented HA. BMI (p = 0.001) and Elixhauser Comorbidity Index (p < 0.003) were identified as risk factors of periprosthetic joint infection (PJI), while in THA cemented prosthesis also demonstrated an increased risk within the first 30 days (hazard ratio (HR) = 2.73; p = 0.010).Conclusion: The rate of infection after intracapsular femoral neck fracture was statistically significantly reduced in patients treated by antibiotic-loaded cemented HA. Particularly for patients with multiple risk factors for the development of a PJI, the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection.Cite this article: Bone Joint Res 2023;12(5):331–338.
- 16 May 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 12 (5) , 331-338
Open AccessInfection after intracapsular femoral neck fracture – does antibiotic-loaded bone cement reduce infection risk after hemiarthroplasty and total hip arthroplasty?
Aims: The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture.Methods: Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching.Results: Overall in 13,612 cases of intracapsular femoral neck fracture, 9,110 (66.9%) HAs and 4,502 (33.1%) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared with uncemented fixated prosthesis (p = 0.013). In patients with THA no statistical difference between cemented and uncemented prosthesis was registered, however after one year 2.4% of infections were detected in uncemented and 2.1% in cemented THA. In the subpopulation of HA after one year, 1.9% of infections were registered in cemented and 2.8% in uncemented HA. BMI (p = 0.001) and Elixhauser Comorbidity Index (p < 0.003) were identified as risk factors of periprosthetic joint infection (PJI), while in THA cemented prosthesis also demonstrated an increased risk within the first 30 days (hazard ratio (HR) = 2.73; p = 0.010).Conclusion: The rate of infection after intracapsular femoral neck fracture was statistically significantly reduced in patients treated by antibiotic-loaded cemented HA. Particularly for patients with multiple risk factors for the development of a PJI, the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection.Cite this article: Bone Joint Res 2023;12(5):331–338.
- Open Access
- 8 April 2023
- Published by MDPI AG in Antibiotics
- Vol. 12 (4) , 732
The Prophylactic Effect of Single vs. Dual Antibiotic-Loaded Bone Cement against Periprosthetic Joint Infection Following Hip Arthroplasty for Femoral Neck Fracture: An Analysis of the German Arthroplasty Registry
Background: Antibiotic-loaded bone cement in arthroplasties is currently experiencing increased usage. Therefore, single and double antibiotic-loaded bone cements are commercially available and used in orthopedic surgery. The aim of this investigation was to compare the clinical use of single compared to dual antibiotic-loaded bone cement for implant fixation after femoral neck fracture. Further infection rates were to be compared in (partial) arthroplasty for the treatment of femoral neck fracture for both treatment options. Methods: On the basis of the German Arthroplasty Registry (EPRD), all cases of femoral neck fracture treated with hemiarthroplasty (HA), or total hip arthroplasty (THA) with single and dual antibiotic-loaded bone cement, were included into the data analysis. The infection risk was compared using Kaplan-Meier estimates. Results: In total, 26,845 cases (HA 76.3%–THA: 23.7%) with femoral neck fracture were included. Within recent years, an increasing usage of dual antibiotic-loaded cement in Germany, with a current proportion of 7.30% in arthroplasty procedures for femoral neck fracture treatment, has been observed. In patients treated with HA, the proportion of dual antibiotic-loaded cement was 7.86%, while in those treated with THA, 5.46% of all prostheses were fixated with a two antibiotic component cement. For all arthroplasty procedures using single antibiotic-loaded bone cement after six months 1.8%, after one year 1.9%, and after five years 2.3%, of the cases failed due to periprosthetic joint infection (PJI), while in the same time period, in cases with dual antibiotic-loaded bone cement 1.5%, 1.5% and 1.5% suffered from infection (p = 0.34). A infection rate of 1.1% after HA with dual antibiotic-loaded bone cement was reported, compared to a 2.1% infection rate whilst using single antibiotic-loaded bone cement after five years (p = 0.098). The number required for treatment when using HA was 91. Conclusions: The use of dual antibiotic-loaded bone cement is increasingly used in arthroplasty procedures after femoral neck fractures. It demonstrates a reduction of PJI after HA and seems, therefore, to be a useful method for the prevention of infection, especially in patients with increased risk factors for PJI.
- 8 April 2023
- Published by MDPI AG in Antibiotics
- Vol. 12 (4) , 732
Open AccessThe Prophylactic Effect of Single vs. Dual Antibiotic-Loaded Bone Cement against Periprosthetic Joint Infection Following Hip Arthroplasty for Femoral Neck Fracture: An Analysis of the German Arthroplasty Registry
Background: Antibiotic-loaded bone cement in arthroplasties is currently experiencing increased usage. Therefore, single and double antibiotic-loaded bone cements are commercially available and used in orthopedic surgery. The aim of this investigation was to compare the clinical use of single compared to dual antibiotic-loaded bone cement for implant fixation after femoral neck fracture. Further infection rates were to be compared in (partial) arthroplasty for the treatment of femoral neck fracture for both treatment options. Methods: On the basis of the German Arthroplasty Registry (EPRD), all cases of femoral neck fracture treated with hemiarthroplasty (HA), or total hip arthroplasty (THA) with single and dual antibiotic-loaded bone cement, were included into the data analysis. The infection risk was compared using Kaplan-Meier estimates. Results: In total, 26,845 cases (HA 76.3%–THA: 23.7%) with femoral neck fracture were included. Within recent years, an increasing usage of dual antibiotic-loaded cement in Germany, with a current proportion of 7.30% in arthroplasty procedures for femoral neck fracture treatment, has been observed. In patients treated with HA, the proportion of dual antibiotic-loaded cement was 7.86%, while in those treated with THA, 5.46% of all prostheses were fixated with a two antibiotic component cement. For all arthroplasty procedures using single antibiotic-loaded bone cement after six months 1.8%, after one year 1.9%, and after five years 2.3%, of the cases failed due to periprosthetic joint infection (PJI), while in the same time period, in cases with dual antibiotic-loaded bone cement 1.5%, 1.5% and 1.5% suffered from infection (p = 0.34). A infection rate of 1.1% after HA with dual antibiotic-loaded bone cement was reported, compared to a 2.1% infection rate whilst using single antibiotic-loaded bone cement after five years (p = 0.098). The number required for treatment when using HA was 91. Conclusions: The use of dual antibiotic-loaded bone cement is increasingly used in arthroplasty procedures after femoral neck fractures. It demonstrates a reduction of PJI after HA and seems, therefore, to be a useful method for the prevention of infection, especially in patients with increased risk factors for PJI.
- 4 August 2022
- Published by Georg Thieme Verlag KG in Orthopädie und Unfallchirurgie up2date
- Vol. 17 (04) , 381-395
Endoprothesenregister Deutschland (EPRD)
Bis 2010 fehlte eine systematische Erfassung der Implantationen von Hüft- und Knieendoprothesen in Deutschland. Durch Gründung und Aufbau des Endoprothesenregisters Deutschland (EPRD) kann zusammen mit den Mitgliedern aus Industrie und den Krankenkassen eine effiziente Aufarbeitung und Analyse der Daten gewährleistet werden. Im Gegensatz zum freiwilligen EPRD wird im geplanten Implantateregister Deutschland (IRD) die Erfassung von Implantationen im IRD für alle Beteiligten verpflichtend werden. Article published online: 04 August 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 4 August 2022
- Published by Georg Thieme Verlag KG in Orthopädie und Unfallchirurgie up2date
- Vol. 17 (04) , 381-395
Endoprothesenregister Deutschland (EPRD)
Bis 2010 fehlte eine systematische Erfassung der Implantationen von Hüft- und Knieendoprothesen in Deutschland. Durch Gründung und Aufbau des Endoprothesenregisters Deutschland (EPRD) kann zusammen mit den Mitgliedern aus Industrie und den Krankenkassen eine effiziente Aufarbeitung und Analyse der Daten gewährleistet werden. Im Gegensatz zum freiwilligen EPRD wird im geplanten Implantateregister Deutschland (IRD) die Erfassung von Implantationen im IRD für alle Beteiligten verpflichtend werden. Article published online: 04 August 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 6 August 2020
- Published by Springer Nature in Knie Journal
- Vol. 2 (4) , 267-274
Warum versagen unikondyläre Knieendoprothesen in Deutschland?
- 6 August 2020
- Published by Springer Nature in Knie Journal
- Vol. 2 (4) , 267-274
Warum versagen unikondyläre Knieendoprothesen in Deutschland?
- Open Access
- 1 June 2019
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 4 (6) , 401-408
Orthopaedic registries: the German experience
National joint registries are gaining more and more importance in the fields of implant monitoring/outlier detection and quality of care. The German Arthroplasty Registry (EPRD) was established in 2010 for the purpose of observing the impact of primary hip and knee arthroplasty on the German population. Having now over one million documentations, we introduce the structure of the EPRD and detail the process of data collection. We report on some preliminary trends and contrast these with findings from other joint registries. We introduce the overhauled Arthroplasty Library, that resulted from an international collaboration with National Joint Registry of England, Wales and Northern Ireland. Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180064
- 1 June 2019
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 4 (6) , 401-408
Open AccessOrthopaedic registries: the German experience
National joint registries are gaining more and more importance in the fields of implant monitoring/outlier detection and quality of care. The German Arthroplasty Registry (EPRD) was established in 2010 for the purpose of observing the impact of primary hip and knee arthroplasty on the German population. Having now over one million documentations, we introduce the structure of the EPRD and detail the process of data collection. We report on some preliminary trends and contrast these with findings from other joint registries. We introduce the overhauled Arthroplasty Library, that resulted from an international collaboration with National Joint Registry of England, Wales and Northern Ireland. Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180064