Latest Publications
- Open Access
Diagnostic Simplexes for Dissolved-Gas Analysis
A Duval triangle is a diagram used for fault type identification in dissolved-gas analysis of oil-filled high-voltage transformers and other electrical apparatus. The proportional concentrations of three fault gases (such as methane, ethylene, and acetylene) are used as coordinates to plot a point in an equilateral triangle and identify the fault zone in which it is located. Each point in the triangle corresponds to a unique combination of gas proportions. Diagnostic pentagons published by Duval and others seek to emulate the triangles while incorporating five fault gases instead of three. Unfortunately the mapping of five gas proportions to a point inside a two-dimensional pentagon is many-to-one; consequently, dissimilar combinations of gas proportions are mapped to the same point in the pentagon, resulting in mis-diagnosis. One solution is to replace the pentagon with a four-dimensional simplex, a direct generalization of the Duval triangle. In a comparison using cases confirmed by inspection, the simplex outperformed three ratio methods, Duval triangle 1, and two pentagons.
Open AccessDiagnostic Simplexes for Dissolved-Gas Analysis
A Duval triangle is a diagram used for fault type identification in dissolved-gas analysis of oil-filled high-voltage transformers and other electrical apparatus. The proportional concentrations of three fault gases (such as methane, ethylene, and acetylene) are used as coordinates to plot a point in an equilateral triangle and identify the fault zone in which it is located. Each point in the triangle corresponds to a unique combination of gas proportions. Diagnostic pentagons published by Duval and others seek to emulate the triangles while incorporating five fault gases instead of three. Unfortunately the mapping of five gas proportions to a point inside a two-dimensional pentagon is many-to-one; consequently, dissimilar combinations of gas proportions are mapped to the same point in the pentagon, resulting in mis-diagnosis. One solution is to replace the pentagon with a four-dimensional simplex, a direct generalization of the Duval triangle. In a comparison using cases confirmed by inspection, the simplex outperformed three ratio methods, Duval triangle 1, and two pentagons.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Thermodynamic estimation of transformer fault severity
Summary form only given. Conventional practice for transformer dissolved-gas analysis (DGA) is to use concentrations of several fault gases, with or without total dissolved combustible gas (TDCG), for evaluating apparent fault severity. We suggest a simpler approach based on the normalized energy intensity (NEI), a quantity related directly to fault energy dissipated within the transformer. DGA fault severity scoring based on NEI is shown to be sensitive to all IEC fault types and to be more responsive to shifts in the relative concentrations of the fault gases than scoring based on fault gas concentrations. Instead of eight or more gas concentration limits, NEI scoring requires only two or three limits that can be empirically derived to suit local requirements for any population of mineral-oil-filled power transformers.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Thermodynamic estimation of transformer fault severity
Summary form only given. Conventional practice for transformer dissolved-gas analysis (DGA) is to use concentrations of several fault gases, with or without total dissolved combustible gas (TDCG), for evaluating apparent fault severity. We suggest a simpler approach based on the normalized energy intensity (NEI), a quantity related directly to fault energy dissipated within the transformer. DGA fault severity scoring based on NEI is shown to be sensitive to all IEC fault types and to be more responsive to shifts in the relative concentrations of the fault gases than scoring based on fault gas concentrations. Instead of eight or more gas concentration limits, NEI scoring requires only two or three limits that can be empirically derived to suit local requirements for any population of mineral-oil-filled power transformers.
- Open Access
- 23 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 30 (4) , 1941-1948
Thermodynamic Estimation of Transformer Fault Severity
Conventional practice for transformer dissolved gas analysis (DGA) is to use concentrations of several fault gases, with or without total dissolved combustible gas, for evaluating apparent fault severity. We suggest a simpler approach based on the normalized energy intensity (NEI), a quantity related directly to fault energy dissipated within the transformer. DGA fault severity scoring based on NEI is shown to be sensitive to all IEC fault types and to be more responsive to shifts in the relative concentrations of the fault gases than scoring based on fault gas concentrations. Instead of eight or more gas concentration limits, NEI scoring requires only two or three limits that can be empirically derived to suit local requirements for any population of mineral-oil-filled power transformers.
- 23 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 30 (4) , 1941-1948
Open AccessThermodynamic Estimation of Transformer Fault Severity
Conventional practice for transformer dissolved gas analysis (DGA) is to use concentrations of several fault gases, with or without total dissolved combustible gas, for evaluating apparent fault severity. We suggest a simpler approach based on the normalized energy intensity (NEI), a quantity related directly to fault energy dissipated within the transformer. DGA fault severity scoring based on NEI is shown to be sensitive to all IEC fault types and to be more responsive to shifts in the relative concentrations of the fault gases than scoring based on fault gas concentrations. Instead of eight or more gas concentration limits, NEI scoring requires only two or three limits that can be empirically derived to suit local requirements for any population of mineral-oil-filled power transformers.
- 20 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 27 (2) , 554-559
A Thermodynamic Approach to Evaluation of the Severity of Transformer Faults
Dissolved gas analysis (DGA) has been used to classify the type and severity of faults in transformers. The method commonly used to identify severity is to measure the total fault gas concentration and its rate of change, without regard to the relative concentrations of individual gases. Thermodynamic analysis indicates that the energy required to form gases increases in the order CH4 <; C2H6 ≤ CO ≤ C2H4 <; H2 ≪ C2H2. Based on these results, an energy-weighted dissolved gas analysis (EWDGA) is proposed, where concentrations of individual gases are multiplied by a weighting factor that is proportional to the energy required to produce each gas. Statistical calculations are used to show that EWDGA is more sensitive to high-energy faults than simple DGA, hence minimizing the damage caused by those faults.
- 20 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 27 (2) , 554-559
A Thermodynamic Approach to Evaluation of the Severity of Transformer Faults
Dissolved gas analysis (DGA) has been used to classify the type and severity of faults in transformers. The method commonly used to identify severity is to measure the total fault gas concentration and its rate of change, without regard to the relative concentrations of individual gases. Thermodynamic analysis indicates that the energy required to form gases increases in the order CH4 <; C2H6 ≤ CO ≤ C2H4 <; H2 ≪ C2H2. Based on these results, an energy-weighted dissolved gas analysis (EWDGA) is proposed, where concentrations of individual gases are multiplied by a weighting factor that is proportional to the energy required to produce each gas. Statistical calculations are used to show that EWDGA is more sensitive to high-energy faults than simple DGA, hence minimizing the damage caused by those faults.
- 1 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 21 (4) , 21-27
Improving the reliability of transformer gas-in-oil diagnosis
Dissolved gas analysis (DGA) is widely used to detect incipient faults in oil-filled electrical equipment. There is always some degree of inaccuracy in laboratory dissolved-gas measurements, especially at low gas concentrations, which affects gas ratios and other diagnostic calculations. This paper examines the measurement inaccuracy problem in detail using recent CIGRE data. It shows how proper allowance for this inaccuracy can improve transformer condition assessment and diagnosis by DGA.
- 1 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 21 (4) , 21-27
Improving the reliability of transformer gas-in-oil diagnosis
Dissolved gas analysis (DGA) is widely used to detect incipient faults in oil-filled electrical equipment. There is always some degree of inaccuracy in laboratory dissolved-gas measurements, especially at low gas concentrations, which affects gas ratios and other diagnostic calculations. This paper examines the measurement inaccuracy problem in detail using recent CIGRE data. It shows how proper allowance for this inaccuracy can improve transformer condition assessment and diagnosis by DGA.
- 30 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 329-332 vol.1
Transformer oil diagnosis using fuzzy logic and neural networks
Dissolved-gas analysis (DGA) is widely used for detection and diagnosis of incipient faults in large oil-filled transformers. Many factors contribute to extreme "noisiness" in the data and make early fault detection and diagnosis difficult. This paper shows how fuzzy logic and neural networks are being used to automate standard DGA methods and improve their usefulness for power transformer fault diagnosis. The use of neural networks for DGA-with or without fuzzy logic-is discussed, and some related work is described briefly.
- 30 December 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 329-332 vol.1
Transformer oil diagnosis using fuzzy logic and neural networks
Dissolved-gas analysis (DGA) is widely used for detection and diagnosis of incipient faults in large oil-filled transformers. Many factors contribute to extreme "noisiness" in the data and make early fault detection and diagnosis difficult. This paper shows how fuzzy logic and neural networks are being used to automate standard DGA methods and improve their usefulness for power transformer fault diagnosis. The use of neural networks for DGA-with or without fuzzy logic-is discussed, and some related work is described briefly.
- Open Access
- 1 January 1987
- Published by Institute of Mathematics, Polish Academy of Sciences in Colloquium Mathematicum
- Vol. 55 (1) , 11-17
Morita equivalence of algebraic theories
- 1 January 1987
- Published by Institute of Mathematics, Polish Academy of Sciences in Colloquium Mathematicum
- Vol. 55 (1) , 11-17
Open AccessMorita equivalence of algebraic theories
- Open Access
- 1 January 1980
- Published by Institute of Mathematics, Polish Academy of Sciences in Fundamenta Mathematicae
- Vol. 110 (2) , 75-90
Weakly monadic Boolean extension functors
- 1 January 1980
- Published by Institute of Mathematics, Polish Academy of Sciences in Fundamenta Mathematicae
- Vol. 110 (2) , 75-90
Open AccessWeakly monadic Boolean extension functors