Brenton Keller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brenton Keller has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Mark Draelos
University of Michigan
3 shared publications Anthony N. Kuo
Department of Ophthalmology, Duke University Medical Center, Durham, USA
2 shared publicationsJoseph A. Izatt
Department of Ophthalmology, Duke University Medical Center, Durham NC 27710, USA
2 shared publications- Joseph A. Izatt
Department of Biomedical Engineering, Duke University, Durham, NC, USA
2 shared publications - Kris Hauser
School of Computing and Data Science, University of Illinois at Urbana-Champaign, Urbana, IL, USA
2 shared publications - Sina Farsiu
Duke University
2 shared publications
Latest Publications
- Open Access
- 16 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 36 (4) , 1207-1218
Optical Coherence Tomography-Guided Robotic Ophthalmic Microsurgery via Reinforcement Learning from Demonstration
Ophthalmic microsurgery is technically difficult because the scale of required surgical tool manipulations challenge the limits of the surgeon's visual acuity, sensory perception, and physical dexterity. Intraoperative optical coherence tomography (OCT) imaging with micrometer-scale resolution is increasingly being used to monitor and provide enhanced real-time visualization of ophthalmic surgical maneuvers, but surgeons still face physical limitations when manipulating instruments inside the eye. Autonomously controlled robots are one avenue for overcoming these physical limitations. In this article, we demonstrate the feasibility of using learning from demonstration and reinforcement learning with an industrial robot to perform OCT-guided corneal needle insertions in an ex vivo model of deep anterior lamellar keratoplasty (DALK) surgery. Our reinforcement learning agent trained on ex vivo human corneas, then outperformed surgical fellows in reaching a target needle insertion depth in mock corneal surgery trials. This article shows the combination of learning from demonstration and reinforcement learning is a viable option for performing OCT-guided robotic ophthalmic surgery.
- 16 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 36 (4) , 1207-1218
Open AccessOptical Coherence Tomography-Guided Robotic Ophthalmic Microsurgery via Reinforcement Learning from Demonstration
Ophthalmic microsurgery is technically difficult because the scale of required surgical tool manipulations challenge the limits of the surgeon's visual acuity, sensory perception, and physical dexterity. Intraoperative optical coherence tomography (OCT) imaging with micrometer-scale resolution is increasingly being used to monitor and provide enhanced real-time visualization of ophthalmic surgical maneuvers, but surgeons still face physical limitations when manipulating instruments inside the eye. Autonomously controlled robots are one avenue for overcoming these physical limitations. In this article, we demonstrate the feasibility of using learning from demonstration and reinforcement learning with an industrial robot to perform OCT-guided corneal needle insertions in an ex vivo model of deep anterior lamellar keratoplasty (DALK) surgery. Our reinforcement learning agent trained on ex vivo human corneas, then outperformed surgical fellows in reaching a target needle insertion depth in mock corneal surgery trials. This article shows the combination of learning from demonstration and reinforcement learning is a viable option for performing OCT-guided robotic ophthalmic surgery.
- 20 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (00189294) , 1
Optical Coherence Tomography Guided Robotic Needle Insertion for Deep Anterior Lamellar Keratoplasty
Objective: Deep anterior lamellar keratoplasty (DALK) significantly reduces the post-transplantation morbidity in patients eligible for partial-thickness cornea grafts. The popular “big bubble” technique for DALK is so challenging, however, that a significant fraction of corneal pneumodissection attempts fail for surgeons without extensive DALK-specific experience, even with previous-generation cross-sectional optical coherence tomography (OCT) guidance. We seek to develop robotic, volumetric OCT-guided technology capable of facilitating or automating the difficult needle insertion step in DALK. Methods: Our system provides for real-time volumetric corneal imaging, segmentation, and tracking of the needle insertion to display feedback for surgeons and to generate needle insertion plans for robotic execution. We include a non-automatic mode for cooperative needle control for stabilization and tremor attenuation, and an automatic mode in which needle insertion plans are generated based on OCT tracking results and executed under surgeon hold-to-run control by the robot arm. We evaluated and compared freehand, volumetric OCT-guided, cooperative, and automatic needle insertion approaches in terms of perforation rate and final needle depth in an ex vivo human cornea model. Results: Volumetric OCT visualization reduces cornea perforations and beneficially increases final needle depth in manual insertions by clinically significant amounts. Our automatic robotic needle insertion techniques meet or exceed surgeon performance in both needle placement and perforation rate. Conclusion: Volumetric OCT is a key enabler for surgeons, although robotic techniques can reliably replicate their performance. Significance: Robotic needle control and volumetric OCT promise to improve outcomes in DALK.
- 20 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (00189294) , 1
Optical Coherence Tomography Guided Robotic Needle Insertion for Deep Anterior Lamellar Keratoplasty
Objective: Deep anterior lamellar keratoplasty (DALK) significantly reduces the post-transplantation morbidity in patients eligible for partial-thickness cornea grafts. The popular “big bubble” technique for DALK is so challenging, however, that a significant fraction of corneal pneumodissection attempts fail for surgeons without extensive DALK-specific experience, even with previous-generation cross-sectional optical coherence tomography (OCT) guidance. We seek to develop robotic, volumetric OCT-guided technology capable of facilitating or automating the difficult needle insertion step in DALK. Methods: Our system provides for real-time volumetric corneal imaging, segmentation, and tracking of the needle insertion to display feedback for surgeons and to generate needle insertion plans for robotic execution. We include a non-automatic mode for cooperative needle control for stabilization and tremor attenuation, and an automatic mode in which needle insertion plans are generated based on OCT tracking results and executed under surgeon hold-to-run control by the robot arm. We evaluated and compared freehand, volumetric OCT-guided, cooperative, and automatic needle insertion approaches in terms of perforation rate and final needle depth in an ex vivo human cornea model. Results: Volumetric OCT visualization reduces cornea perforations and beneficially increases final needle depth in manual insertions by clinically significant amounts. Our automatic robotic needle insertion techniques meet or exceed surgeon performance in both needle placement and perforation rate. Conclusion: Volumetric OCT is a key enabler for surgeons, although robotic techniques can reliably replicate their performance. Significance: Robotic needle control and volumetric OCT promise to improve outcomes in DALK.
- Open Access
- 21 May 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (6) , 2716-2732
Real-time corneal segmentation and 3D needle tracking in intrasurgical OCT
Ophthalmic procedures demand precise surgical instrument control in depth, yet standard operating microscopes supply limited depth perception. Current commercial microscope-integrated optical coherence tomography partially meets this need with manually-positioned cross-sectional images that offer qualitative estimates of depth. In this work, we present methods for automatic quantitative depth measurement using real-time, two-surface corneal segmentation and needle tracking in OCT volumes. We then demonstrate these methods for guidance of ex vivo deep anterior lamellar keratoplasty (DALK) needle insertions. Surgeons using the output of these methods improved their ability to reach a target depth, and decreased their incidence of corneal perforations, both with statistical significance. We believe these methods could increase the success rate of DALK and thereby improve patient outcomes.
- 21 May 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (6) , 2716-2732
Open AccessReal-time corneal segmentation and 3D needle tracking in intrasurgical OCT
Ophthalmic procedures demand precise surgical instrument control in depth, yet standard operating microscopes supply limited depth perception. Current commercial microscope-integrated optical coherence tomography partially meets this need with manually-positioned cross-sectional images that offer qualitative estimates of depth. In this work, we present methods for automatic quantitative depth measurement using real-time, two-surface corneal segmentation and needle tracking in OCT volumes. We then demonstrate these methods for guidance of ex vivo deep anterior lamellar keratoplasty (DALK) needle insertions. Surgeons using the output of these methods improved their ability to reach a target depth, and decreased their incidence of corneal perforations, both with statistical significance. We believe these methods could increase the success rate of DALK and thereby improve patient outcomes.
- 1 July 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (7) , 076015
Length-adaptive graph search for automatic segmentation of pathological features in optical coherence tomography images
We introduce a metric in graph search and demonstrate its application for segmenting retinal optical coherence tomography (OCT) images of macular pathology. Our proposed “adjusted mean arc length” (AMAL) metric is an adaptation of the lowest mean arc length search technique for automated OCT segmentation. We compare this method to Dijkstra’s shortest path algorithm, which we utilized previously in our popular graph theory and dynamic programming segmentation technique. As an illustrative example, we show that AMAL-based length-adaptive segmentation outperforms the shortest path in delineating the retina/vitreous boundary of patients with full-thickness macular holes when compared with expert manual grading.
- 1 July 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (7) , 076015
Length-adaptive graph search for automatic segmentation of pathological features in optical coherence tomography images
We introduce a metric in graph search and demonstrate its application for segmenting retinal optical coherence tomography (OCT) images of macular pathology. Our proposed “adjusted mean arc length” (AMAL) metric is an adaptation of the lowest mean arc length search technique for automated OCT segmentation. We compare this method to Dijkstra’s shortest path algorithm, which we utilized previously in our popular graph theory and dynamic programming segmentation technique. As an illustrative example, we show that AMAL-based length-adaptive segmentation outperforms the shortest path in delineating the retina/vitreous boundary of patients with full-thickness macular holes when compared with expert manual grading.