James F. Antaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James F. Antaki has a total of 111 co-authors. Here are the top co-authors by number of shared publications:
- Mansur Zhussupbekov
Meinig School of Biomedical Engineering Cornell University Ithaca New York USA
10 shared publications - Abhishek Karmakar
Meinig School of Biomedical Engineering, Cornell University, Ithaca, 14850, NY, USA
7 shared publications - Greg W. Burgreen
Center for Advanced Vehicular Systems, Mississippi State University, Starkville, 39759, MS, USA
5 shared publications - Jonathan Talbot Butcher
Meinig School of Biomedical Engineering, Cornell University, Ithaca, USA
5 shared publications - Mehrdad Massoudi
U. S. Department of Energy, National Energy Technology Laboratory (NETL), 626 Cochrans Mill Road, Pittsburgh, PA 15236, USA
5 shared publications - Aminat M. Ibrahim
The Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14850, USA
4 shared publications
Latest Publications
- 16 September 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 225, 498-511
Geometry–encoded microtrenches stabilize endothelium on high shear biomaterial surfaces
- 16 September 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 225, 498-511
Geometry–encoded microtrenches stabilize endothelium on high shear biomaterial surfaces
- Open Access
Geometry–Encoded Microtrenches Stabilize Endothelium on High Shear Biomaterial Surfaces
Maintaining a confluent, antithrombotic endothelium on cardiovascular biomaterial surfaces remains a major barrier to long-term hemocompatibility, as endothelial cells (ECs) rapidly denude under supraphysiological shear in prosthetic devices. Here, we hypothesized that mesoscale surface geometry (∼100–200 µm) could reorganize near-wall hemodynamics, preserving endothelial coverage and function under extreme shear. Engineered microtrenches were introduced onto an implant biomaterial to generate spatially defined shear environments. Under supraphysiological near-wall shear (∼250 dyn/cm²), microtrenched geometries created attenuated shear and vorticity gradients. Endothelial monolayers were sustained in these flow domains for 120 hours, whereas flat controls rapidly denuded. Endothelial retention in 22.5° angled trenches increased dramatically, from an EC₅₀ of 33 to 101 dyn/cm². 45° angled trenches further increased endothelial shear resistance to an EC₅₀ of 207 dyn/cm². Endothelial monolayers demonstrated collective mechano-adaptation to ultra-high shear through VE-cadherin junction thickening and coordinated cytoskeletal and nuclear alignment. Mechanoadapted monolayers exhibited increased eNOS expression correlated with local shear and elevated nitrite production (45°: 50.4 ± 6.1 µM; 22.5°: 35.7 ± 3.3 µM; 0°: 28.4 ± 6.8 µM). In contrast, interfaces with abrupt shear transitions or elevated rotational flow exhibited reduced coverage, junctional thinning, and re-emergence of VCAM-1 and PAI-1, indicating inflammatory and pro-thrombotic activation. Structural, functional, and inflammatory readouts exhibited peak responses within a shared shear–vorticity regime. Multivariate regression identified shear–vorticity coupling as the dominant predictor of endothelial persistence, with optima clustering within a mechanical range (≈0.8–2.9 × 10⁶ dyn·cm⁻²·s⁻¹). These findings establish geometry-driven modulation of near-wall flow as a predictive, material-agnostic strategy for endothelialization and vasoprotection of high-shear cardiovascular implants.
Open AccessGeometry–Encoded Microtrenches Stabilize Endothelium on High Shear Biomaterial Surfaces
Maintaining a confluent, antithrombotic endothelium on cardiovascular biomaterial surfaces remains a major barrier to long-term hemocompatibility, as endothelial cells (ECs) rapidly denude under supraphysiological shear in prosthetic devices. Here, we hypothesized that mesoscale surface geometry (∼100–200 µm) could reorganize near-wall hemodynamics, preserving endothelial coverage and function under extreme shear. Engineered microtrenches were introduced onto an implant biomaterial to generate spatially defined shear environments. Under supraphysiological near-wall shear (∼250 dyn/cm²), microtrenched geometries created attenuated shear and vorticity gradients. Endothelial monolayers were sustained in these flow domains for 120 hours, whereas flat controls rapidly denuded. Endothelial retention in 22.5° angled trenches increased dramatically, from an EC₅₀ of 33 to 101 dyn/cm². 45° angled trenches further increased endothelial shear resistance to an EC₅₀ of 207 dyn/cm². Endothelial monolayers demonstrated collective mechano-adaptation to ultra-high shear through VE-cadherin junction thickening and coordinated cytoskeletal and nuclear alignment. Mechanoadapted monolayers exhibited increased eNOS expression correlated with local shear and elevated nitrite production (45°: 50.4 ± 6.1 µM; 22.5°: 35.7 ± 3.3 µM; 0°: 28.4 ± 6.8 µM). In contrast, interfaces with abrupt shear transitions or elevated rotational flow exhibited reduced coverage, junctional thinning, and re-emergence of VCAM-1 and PAI-1, indicating inflammatory and pro-thrombotic activation. Structural, functional, and inflammatory readouts exhibited peak responses within a shared shear–vorticity regime. Multivariate regression identified shear–vorticity coupling as the dominant predictor of endothelial persistence, with optima clustering within a mechanical range (≈0.8–2.9 × 10⁶ dyn·cm⁻²·s⁻¹). These findings establish geometry-driven modulation of near-wall flow as a predictive, material-agnostic strategy for endothelialization and vasoprotection of high-shear cardiovascular implants.
- Open Access
- 11 March 2026
- Published by Elsevier in SSRN Electronic Journal
A Comprehensive Numerical Model of Thrombus Embolization: Fluid-Thrombus Interactions Through a Coupled Computational Fluid Dynamics - Peridynamics Framework
Thromboembolic diseases, which account for approximately one-third of global deaths, are characterized by thrombus embolization—the process whereby blood clots undergo cohesive/adhesive fracture under fluid-induced forces. Comprehensive numerical modeling of this multiphysics phenomenon has remained challenging, and robust computational frameworks are scarce. This work substantially advances the state-of-the-art of numerical models of thrombus embolization by presenting a framework that couples Lagrangian non-ordinary state-based peridynamics with Eulerian computational fluid dynamics. The formulation can (i) incorporate complex macroscale constitutive laws for a thrombus, (ii) capture delamination physics between a thrombus and a contacting surface, and (iii) couple thrombus structural dynamics with fluid flow discretized on arbitrary unstructured meshes. The latter capability is achieved through the development of a robust interpolation scheme for fast bi-directional data transfer between polyhedral meshes and peridynamic particle clouds. This also advances the literature of peridynamic coupled fluid numerical models, which are mostly limited to bond-based peridynamics and Cartesian meshes. The framework undergoes rigorous validation through five computationally unique benchmarks. The validated framework is then applied to reproduce reported experimental results of embolization of preformed thrombus within a polycarbonate cylindrical tube under varying flow rates. To demonstrate that the numerical framework can support spatially heterogeneous material properties (a capability absent in other approaches), a synthetic test case is reported. Unlike homogeneous assumptions that always predict leading-edge detachment, heterogeneous material properties enable trailing-edge detachment, thus elucidating this previously unexplained experimental observation.
- 11 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Comprehensive Numerical Model of Thrombus Embolization: Fluid-Thrombus Interactions Through a Coupled Computational Fluid Dynamics - Peridynamics Framework
Thromboembolic diseases, which account for approximately one-third of global deaths, are characterized by thrombus embolization—the process whereby blood clots undergo cohesive/adhesive fracture under fluid-induced forces. Comprehensive numerical modeling of this multiphysics phenomenon has remained challenging, and robust computational frameworks are scarce. This work substantially advances the state-of-the-art of numerical models of thrombus embolization by presenting a framework that couples Lagrangian non-ordinary state-based peridynamics with Eulerian computational fluid dynamics. The formulation can (i) incorporate complex macroscale constitutive laws for a thrombus, (ii) capture delamination physics between a thrombus and a contacting surface, and (iii) couple thrombus structural dynamics with fluid flow discretized on arbitrary unstructured meshes. The latter capability is achieved through the development of a robust interpolation scheme for fast bi-directional data transfer between polyhedral meshes and peridynamic particle clouds. This also advances the literature of peridynamic coupled fluid numerical models, which are mostly limited to bond-based peridynamics and Cartesian meshes. The framework undergoes rigorous validation through five computationally unique benchmarks. The validated framework is then applied to reproduce reported experimental results of embolization of preformed thrombus within a polycarbonate cylindrical tube under varying flow rates. To demonstrate that the numerical framework can support spatially heterogeneous material properties (a capability absent in other approaches), a synthetic test case is reported. Unlike homogeneous assumptions that always predict leading-edge detachment, heterogeneous material properties enable trailing-edge detachment, thus elucidating this previously unexplained experimental observation.
- 18 February 2026
- Published by Springer Nature in Journal of Cardiovascular Translational Research
- Vol. 19 (1) , 25
Computational Fluid Dynamics Simulation of Endothelium-Modulated Thrombosis
The development of blood-wetted artificial organs is limited by thrombosis on synthetic biomaterial surfaces. In contrast, the endothelium of the vasculature creates a natural barrier to both thrombosis and pannus growth. Consequently, efforts have been made to endothelialize synthetic biomaterials used in blood-wetted devices. Therefore, this study was undertaken to provide a numerical model to simulate the inhibitory effects of EC-derived nitric oxide (NO) on platelet deposition. An existing multi-constituent continuum model of thrombosis was amended to incorporate shear-dependent generation of NO as an anticoagulant. A simulation was performed of blood flow through a bipartite parallel plate channel having an endothelialized upstream layer followed by a pro-coagulant collagen surface downstream. The simulation showed that endothelial-derived NO inhibited downstream platelet deposition, reducing thrombus growth and creating a thrombus-free zone immediately downstream. This enhanced simulation model of thrombosis provides insights into factors that may guide future endothelialization of artificial organs and other blood-wetted devices.
- 18 February 2026
- Published by Springer Nature in Journal of Cardiovascular Translational Research
- Vol. 19 (1) , 25
Computational Fluid Dynamics Simulation of Endothelium-Modulated Thrombosis
The development of blood-wetted artificial organs is limited by thrombosis on synthetic biomaterial surfaces. In contrast, the endothelium of the vasculature creates a natural barrier to both thrombosis and pannus growth. Consequently, efforts have been made to endothelialize synthetic biomaterials used in blood-wetted devices. Therefore, this study was undertaken to provide a numerical model to simulate the inhibitory effects of EC-derived nitric oxide (NO) on platelet deposition. An existing multi-constituent continuum model of thrombosis was amended to incorporate shear-dependent generation of NO as an anticoagulant. A simulation was performed of blood flow through a bipartite parallel plate channel having an endothelialized upstream layer followed by a pro-coagulant collagen surface downstream. The simulation showed that endothelial-derived NO inhibited downstream platelet deposition, reducing thrombus growth and creating a thrombus-free zone immediately downstream. This enhanced simulation model of thrombosis provides insights into factors that may guide future endothelialization of artificial organs and other blood-wetted devices.
- 17 November 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (11) , e70118
Towards a Model of Thrombus Embolization: Structural Response and Failure of Blood Clots Through Peridynamics
Despite the high mortality rates associated with thromboembolic diseases, computational modeling of the physics of thromboembolism remains underdeveloped in the literature due to the inadequacy of classical finite element methods to accommodate the growth, large deformation, and fracture of blood clots, especially under the influence of fluid dynamic forces. Accordingly, we present a meshless numerical framework, employing peridynamics (PD) that readily captures the constitutive response, damage progression, and eventual failure of a blood clot. The PD framework was validated against three benchmark test cases: tensile loading of a plate with a hole, torsional loading of a column, and tensile loading of thin structural plates both with and without notches. Comparative quantitative and qualitative analysis demonstrated excellent agreement with finite element solutions generated using the commercial software ANSYS. The validated framework was then used to calibrate the peridynamic parameters to accurately reproduce the mechanical response, the cohesive bulk fracture of blood clots under tensile loading, and the debonding of blood clots from artificial surfaces, including titanium (Ti), polyurethane (PU), and polytetrafluoroethylene (PTFE). Force–displacement curves obtained using these calibrated parameters demonstrated a strong correlation with experimental data.
- 17 November 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (11) , e70118
Towards a Model of Thrombus Embolization: Structural Response and Failure of Blood Clots Through Peridynamics
Despite the high mortality rates associated with thromboembolic diseases, computational modeling of the physics of thromboembolism remains underdeveloped in the literature due to the inadequacy of classical finite element methods to accommodate the growth, large deformation, and fracture of blood clots, especially under the influence of fluid dynamic forces. Accordingly, we present a meshless numerical framework, employing peridynamics (PD) that readily captures the constitutive response, damage progression, and eventual failure of a blood clot. The PD framework was validated against three benchmark test cases: tensile loading of a plate with a hole, torsional loading of a column, and tensile loading of thin structural plates both with and without notches. Comparative quantitative and qualitative analysis demonstrated excellent agreement with finite element solutions generated using the commercial software ANSYS. The validated framework was then used to calibrate the peridynamic parameters to accurately reproduce the mechanical response, the cohesive bulk fracture of blood clots under tensile loading, and the debonding of blood clots from artificial surfaces, including titanium (Ti), polyurethane (PU), and polytetrafluoroethylene (PTFE). Force–displacement curves obtained using these calibrated parameters demonstrated a strong correlation with experimental data.
- 14 August 2025
- Published by Wiley in Artificial Organs
- Vol. 50 (2) , 209-220
Multi‐Objective CFD Optimization of an Intermediate Diffuser Stage for PediaFlow Pediatric Ventricular Assist Device
Background: Computational fluid dynamics (CFD) has become an essential design tool for ventricular assist devices (VADs), where the goal of maximizing performance often conflicts with biocompatibility. This tradeoff becomes even more pronounced in pediatric applications due to the stringent size constraints imposed by the smaller patient population. This study presents an automated CFD‐driven shape optimization of a new intermediate diffuser stage for the PediaFlow pediatric VAD, positioned immediately downstream of the impeller to improve pressure recovery. Methods: We adopted a multi‐objective optimization approach to maximize pressure recovery while minimizing hemolysis. The proposed diffuser stage was isolated from the rest of the flow domain, enabling efficient evaluation of over 450 design variants using Sobol sequence, which yielded a Pareto front of nondominated solutions. The selected best candidate was further refined using a local T‐search algorithm. We then incorporated the optimized front diffuser into the full pump for CFD verification and in vitro validation. Results: We identified critical dependencies where longer blades increased pressure recovery but also hemolysis, while the wrap angle showed a strong parabolic relationship with pressure recovery but a monotonic relationship with hemolysis. Counterintuitively, configurations with fewer blades (2, 3) consistently outperformed those with more blades (4, 5) in both metrics. The optimized two‐blade design enabled operation at lower pump speeds (14 000 vs. 16 000 RPM), improving hydraulic efficiency from 26.3% to 32.5% and reducing hemolysis by 31%. Conclusion: This approach demonstrates that multi‐objective CFD optimization can systematically explore complex design spaces while balancing competing priorities of performance and hemocompatibility for pediatric VADs.
- 14 August 2025
- Published by Wiley in Artificial Organs
- Vol. 50 (2) , 209-220
Multi‐Objective CFD Optimization of an Intermediate Diffuser Stage for PediaFlow Pediatric Ventricular Assist Device
Background: Computational fluid dynamics (CFD) has become an essential design tool for ventricular assist devices (VADs), where the goal of maximizing performance often conflicts with biocompatibility. This tradeoff becomes even more pronounced in pediatric applications due to the stringent size constraints imposed by the smaller patient population. This study presents an automated CFD‐driven shape optimization of a new intermediate diffuser stage for the PediaFlow pediatric VAD, positioned immediately downstream of the impeller to improve pressure recovery. Methods: We adopted a multi‐objective optimization approach to maximize pressure recovery while minimizing hemolysis. The proposed diffuser stage was isolated from the rest of the flow domain, enabling efficient evaluation of over 450 design variants using Sobol sequence, which yielded a Pareto front of nondominated solutions. The selected best candidate was further refined using a local T‐search algorithm. We then incorporated the optimized front diffuser into the full pump for CFD verification and in vitro validation. Results: We identified critical dependencies where longer blades increased pressure recovery but also hemolysis, while the wrap angle showed a strong parabolic relationship with pressure recovery but a monotonic relationship with hemolysis. Counterintuitively, configurations with fewer blades (2, 3) consistently outperformed those with more blades (4, 5) in both metrics. The optimized two‐blade design enabled operation at lower pump speeds (14 000 vs. 16 000 RPM), improving hydraulic efficiency from 26.3% to 32.5% and reducing hemolysis by 31%. Conclusion: This approach demonstrates that multi‐objective CFD optimization can systematically explore complex design spaces while balancing competing priorities of performance and hemocompatibility for pediatric VADs.
- Open Access
- 19 July 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 271, 108947
Multi-scale simulation of red blood cell trauma in large-scale high-shear flows after Norwood operation
- 19 July 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 271, 108947
Open AccessMulti-scale simulation of red blood cell trauma in large-scale high-shear flows after Norwood operation
- Open Access
Multi-objective CFD optimization of an intermediate diffuser stage for PediaFlow pediatric ventricular assist device
Background: Computational fluid dynamics (CFD) has become an essential design tool for ventricular assist devices (VADs), where the goal of maximizing performance often conflicts with biocompatibility. This tradeoff becomes even more pronounced in pediatric applications due to the stringent size constraints imposed by the smaller patient population. This study presents an automated CFD-driven shape optimization of a new intermediate diffuser stage for the PediaFlow pediatric VAD, positioned immediately downstream of the impeller to improve pressure recovery. Methods: We adopted a multi-objective optimization approach to maximize pressure recovery while minimizing hemolysis. The proposed diffuser stage was isolated from the rest of the flow domain, enabling efficient evaluation of over 450 design variants using Sobol sequence, which yielded a Pareto front of non-dominated solutions. The selected best candidate was further refined using local T-search algorithm. We then incorporated the optimized front diffuser into the full pump for CFD verification and in vitro validation. Results: We identified critical dependencies where longer blades increased pressure recovery but also hemolysis, while the wrap angle showed a strong parabolic relationship with pressure recovery but a monotonic relationship with hemolysis. Counterintuitively, configurations with fewer blades (2-3) consistently outperformed those with more blades (4-5) in both metrics. The optimized two-blade design enabled operation at lower pump speeds (14,000 vs 16,000 RPM), improving hydraulic efficiency from 26.3% to 32.5% and reducing hemolysis by 31%. Conclusion: This approach demonstrates that multi-objective CFD optimization can systematically explore complex design spaces while balancing competing priorities of performance and hemocompatibility for pediatric VADs.
Open AccessMulti-objective CFD optimization of an intermediate diffuser stage for PediaFlow pediatric ventricular assist device
Background: Computational fluid dynamics (CFD) has become an essential design tool for ventricular assist devices (VADs), where the goal of maximizing performance often conflicts with biocompatibility. This tradeoff becomes even more pronounced in pediatric applications due to the stringent size constraints imposed by the smaller patient population. This study presents an automated CFD-driven shape optimization of a new intermediate diffuser stage for the PediaFlow pediatric VAD, positioned immediately downstream of the impeller to improve pressure recovery. Methods: We adopted a multi-objective optimization approach to maximize pressure recovery while minimizing hemolysis. The proposed diffuser stage was isolated from the rest of the flow domain, enabling efficient evaluation of over 450 design variants using Sobol sequence, which yielded a Pareto front of non-dominated solutions. The selected best candidate was further refined using local T-search algorithm. We then incorporated the optimized front diffuser into the full pump for CFD verification and in vitro validation. Results: We identified critical dependencies where longer blades increased pressure recovery but also hemolysis, while the wrap angle showed a strong parabolic relationship with pressure recovery but a monotonic relationship with hemolysis. Counterintuitively, configurations with fewer blades (2-3) consistently outperformed those with more blades (4-5) in both metrics. The optimized two-blade design enabled operation at lower pump speeds (14,000 vs 16,000 RPM), improving hydraulic efficiency from 26.3% to 32.5% and reducing hemolysis by 31%. Conclusion: This approach demonstrates that multi-objective CFD optimization can systematically explore complex design spaces while balancing competing priorities of performance and hemocompatibility for pediatric VADs.
- 25 June 2025
- Published by Springer Nature in Cardiovascular Engineering and Technology
- p. 1-12
Hybrid Biophysics Co-Simulation of a Percutaneous Catheter VAD within a Contractile Left Heart
Purpose Ventricular assist devices (VADs) are most often computationally evaluated as isolated devices subjected to idealized steady-state blood flow conditions. In clinical practice, these devices are connected to, or within, diseased pulsatile ventricles of the heart, which can dramatically affect the hemodynamics, hence hemocompatibility-related adverse events such as hemolysis, bleeding, and thrombosis. Therefore, improved simulations are needed to more realistically represent the coupling of devices to the assisted ventricle. Methods To address this need, we present a hybrid biophysics co-simulation strategy to evaluate the blood flow dynamics of a percutaneous catheter VAD in-situ within a pulsatile ventricle coupled to the circulation. Our hybrid strategy utilizes a computationally inexpensive lumped parameter network (LPN) to compute cardiac dynamics and provide one-way coupled physiologically-realistic boundary conditions to a high-fidelity computational fluid dynamics (CFD) model to simulate detailed hemodynamics of the VAD and the VAD-assisted left heart. Results Numerical simulation of a high-speed rotodynamic catheter pump configured as a left ventricular assist device (LVAD) generated a realistic reproduction of the unsteady blood velocity field over one complete cardiac cycle. The biophysics co-simulation strategy resulted in approximately one order of magnitude speed-up compared to a bidirectionally coupled CFD co-simulation. The simulated flow fields revealed persistent swirling blood flow within the ventricle, unsteady flow discharged to aorta by the pump, and significant variations of surface washing around the pump housing during the cardiac cycle. Conclusions This study represents a stepping stone toward physiologically and anatomically realistic evaluation of mechanical circulatory support devices that directly complements and reduces extensive in-vivo studies to mitigates risk of adverse events in the clinical setting.
- 25 June 2025
- Published by Springer Nature in Cardiovascular Engineering and Technology
- p. 1-12
Hybrid Biophysics Co-Simulation of a Percutaneous Catheter VAD within a Contractile Left Heart
Purpose Ventricular assist devices (VADs) are most often computationally evaluated as isolated devices subjected to idealized steady-state blood flow conditions. In clinical practice, these devices are connected to, or within, diseased pulsatile ventricles of the heart, which can dramatically affect the hemodynamics, hence hemocompatibility-related adverse events such as hemolysis, bleeding, and thrombosis. Therefore, improved simulations are needed to more realistically represent the coupling of devices to the assisted ventricle. Methods To address this need, we present a hybrid biophysics co-simulation strategy to evaluate the blood flow dynamics of a percutaneous catheter VAD in-situ within a pulsatile ventricle coupled to the circulation. Our hybrid strategy utilizes a computationally inexpensive lumped parameter network (LPN) to compute cardiac dynamics and provide one-way coupled physiologically-realistic boundary conditions to a high-fidelity computational fluid dynamics (CFD) model to simulate detailed hemodynamics of the VAD and the VAD-assisted left heart. Results Numerical simulation of a high-speed rotodynamic catheter pump configured as a left ventricular assist device (LVAD) generated a realistic reproduction of the unsteady blood velocity field over one complete cardiac cycle. The biophysics co-simulation strategy resulted in approximately one order of magnitude speed-up compared to a bidirectionally coupled CFD co-simulation. The simulated flow fields revealed persistent swirling blood flow within the ventricle, unsteady flow discharged to aorta by the pump, and significant variations of surface washing around the pump housing during the cardiac cycle. Conclusions This study represents a stepping stone toward physiologically and anatomically realistic evaluation of mechanical circulatory support devices that directly complements and reduces extensive in-vivo studies to mitigates risk of adverse events in the clinical setting.