WWWen-Li Wu

Wen-Li Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wen-Li Wu has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The intensity enhancement of transmission small angle x-ray scattering from nanostructures with a high aspect ratio

    by W E Fu, B C He, W L Wu

    Transmission small angle x-ray scattering (tSAXS) has been developed as a metrology for the critical dimension (CD) measurements to facilitate integrated circuit (IC) chip fabrications. Synchrotron x-ray sources were used for their high brilliance and a wavelength less than one tenth of a nanometer was chosen for its high penetration power to enable transmission measurements through a silicon wafer with a nominal thickness of 0.7 mm. A major hold back preventing tSAXS from reaching wide applications in IC fabrication is the lack of high brilliance laboratory-based x-ray sources. Within the last few years, even without any major breakthrough in x-ray source technology, this tSAXS metrology has finally been used for 3D NAND and DRAM, i.e., memory chips with tall or high aspect ratio (HAR) architectures. The scattering intensities from HAR structures will be discussed quantitatively in terms of the sample height and the effective longitudinal coherence length of the incident x-ray.


  • Open Access

    Review of the key milestones in the development of critical dimension small angle x-ray scattering at National Institute of Standards and Technology

    by Wen-Li Wu, R. Joseph Kline, Ronald L. Jones, Hae-Jeong Lee, Eric K. Lin, Daniel F. Sunday, Chengqing Wang, Tengjiao Hu, Christopher L. Soles

    An x-ray scattering based metrology was conceived over 20 years ago as part of a collaboration between National Institute of Standards and Technology (NIST) and International Business Machines Corporation (IBM) to evaluate the performance of lithographic patterning materials for the semiconductor industry. This methodology treated a periodic array of lithographic structures as a diffraction grating and focused on extracting the physical dimensions of the structures in the grating by analyzing the diffraction patterns. In the early stages of the work the focus was on developing the transmission small-angle x-ray scattering (tSAXS) as a metrology tool to measure the critical dimensions (CD) of the lithographic features vital to the integrated circuit chip fabrication. Later, the focus shifted to include grazing incident small-angle x-ray scattering and x-ray reflectivity as parts of the CD metrology tool due to their unique capabilities. Frequently the term critical dimension small-angle x-ray scattering (CDSAXS) has been used as a synonym for the metrology of using tSAXS for CD measurements without mentioning transmission. Various milestones in the CDSAXS development are reviewed in this article together with some prospects regarding the future growth of x-ray-based metrology for complex three-dimensional nanostructures important to semiconductor industries.


  • Open Access

    Measurements of an Effective Longitudinal Coherence Length in Transmission Small Angle X-ray Scatterings

    by Chun-Ting Liu, Bo-Ching He, Guo-Dung Chen, Alice Chinghsuan Chang, Wen-Li Wu, Wei-En Fu

    The notion of an effective longitudinal coherence length with its value much greater than λ2/(2Δλ) has been adopted in small-angle X-ray scattering communities for years, where λ and Δλ denote the incident wavelength and its spread, respectively. Often the implications of the effective longitudinal coherence length do not even enter considerations in the designing and data treatment of small-angle scattering experiments. In this work, conventional transmission small-angle X-ray scattering (tSAXS) was performed to reveal a clear angular dependence on effective longitudinal coherence length. The measured values of effective longitudinal coherence length can be as high as one millimeter, whereas the value of calculated λ2/(2Δλ) is in nanometers.


  • Directed Self-Assembly of Lamellar Copolymers: Effects of Interfacial Interactions on Domain Shape

    by Ginusha M. Perera, Chengqing Wang, Manolis Doxastakis, R. Joseph Kline, Wen-Li Wu, August W. Bosse, Gila E. Stein

    The depth-dependent structure of a poly(styrene-b-methylmethacrylate) (PS-PMMA) line grating (46 nm pitch) was calculated from quantitative analysis of small-angle X-ray scattering profiles. These data demonstrate that domain shapes are significantly deformed near the substrate interface, where the local PS domain shape resembles an hourglass. The bulk equilibrium dimension is recovered near the center of a 64 nm thick film. Simulations based on self-consistent field theory suggest that deformations near the substrate are caused by extensive penetration of the copolymer domains into the underlying substrate coating (a PS-brush). These findings suggest that new coatings for block copolymer directed self-assembly should consider copolymer penetration lengths in addition to tailoring surface energetics. Furthermore, given the resolution and ensemble-averaging features of synchrotron X-ray scattering, we argue that it has the potential to emerge as a “gold-standard” or “benchmark” dimensional metrology and library validation tool for high density, sub-10 nm features.


  • Linewidth Roughness and Cross-sectional Measurements of Sub-50 nm Structures Using CD-SAXS and CD-SEM

    by Chengqing Wang, Kwang-Woo Choi, Wei-En Fu, Ronald L. Jones, Derek L. Ho, Christopher Soles, Eric K. Lin, Wen-Li Wu, James S. Clarke, John S. Villarrubia, et al.

    Critical dimension small angle X-ray scattering (CD- SAXS) is a metrology platform that is capable of measuring the average cross section and linewidth roughness (LWR) in test patterns with pitches ranging from 10 to 500 nm with sub-nm precision. These capabilities are obtained by measuring and modeling the scattering intensities of a collimated X-ray beam with sub-nm wavelength from a periodic pattern, such as those found in optical scatterometry targets. In this work, we evaluated the capability of both synchrotron-based and laboratory-scale CD-SAXS for characterizing LWR from measurements of periodic line/space patterns fabricated with extreme ultraviolet (EUV) lithography with sub-50 nm linewidths and designed with programmed roughness amplitude and frequency. For these patterns, CD-SAXS can provide high precision data on cross section dimension, including sidewall angle, line height, linewidth and pitch, as well as the amplitude of LWR. We will also discuss the status of ongoing efforts to compare quantitatively the CD- SAXS data with top-down scanning electron microscopy (CD- SEM) measurements.


  • X-ray and neutron porosimetry as powerful methodologies for determining structural characteristics of porous low-k thin films

    by Hae-Jeong Lee, B.D. Vogt, C.L. Soles, Da-Wei Liu, B.J. Bauer, Wen-Li Wu, E.K. Lin, Gwi-Gwon Kang, Min-Jin Ko

    Methylsilsesquioxane based porous low-k dielectric films with varying porogen loading have been characterized using X-ray and neuron porosimetry to determine their pore size distribution, average density, wall density, porosity, density profiles, and porosity profiles. The porosity and the average pore size of the sample with 45% porogen were 52% and 23 /spl Aring/ in radius, respectively. Pore size, was consistent with that from small angle neutron scattering measurements. The wall density was found to be independent of the porogen content and it appeared that the porogen was 100% effective in generating pores.

  • X-ray absorption spectroscopy to probe interfacial issues in photolithography

    by Joseph L. Lenhart, Daniel A. Fischer, Sharadha Sambasivan, Eric K. Lin, Ronald L. Jones, Christopher L. Soles, Wen-Li Wu, Dario L. Goldfarb, Marie Angelopoulos

    We utilize near edge X-ray absorption fine structure spectroscopy (NEXASFS) to provide detailed chemical insight into two interfacial problems facing sub-100 nm patterning. First, chemically amplified photo-resists are sensitive to surface phenomenon, which causes deviations in the pattern profile near the interface. Striking examples include T-topping, closure, footing, and undercutting. NEXAFS was used to examine surface segregation of a photo-acid generator at the resist/air interface and to illustrate that the surface extent of deprotection in a model resist film can be different than the bulk extent of deprotection. Second, line edge roughness becomes increasingly critical with shrinking patterns, and may be intimately related to the line edge deprotection profile. A NEXAFS technique to surface depth profile for compositional gradients is described with the potential to provide chemical information about the resist line edge.


  • Probing surface and bulk chemistry in resist films using near edge x-ray absorption fine structure

    by Joseph L. Lenhart, Ronald L. Jones, Eric K. Lin, Christopher L. Soles, Wen-Li Wu, Daniel A. Fischer, Sharadha Sambasivan, Dario L. Goldfarb, Marie Angelopoulos

    The performance of chemically amplified photoresists is extremely sensitive to interfacial and surface phenomena, which cause deviations in the pattern profile near an interface. Striking examples include T-topping or closure near the air/resist interface and footing or undercutting near the resist/substrate interface. One focus of our research is to identify mechanisms that cause lithographic patterns to deviate near interfaces. Near edge x-ray absorption fine structure (NEXAFS) is a powerful tool that can be developed and adapted to probe for detailed chemical information near lithographically relevant interfaces. NEXAFS showed that our model resist films exhibited significant surface segregation of the photo acid generator (PAG) at the air interface. The PAG surface mole fraction was 20–70 times greater than the bulk mole fraction and the amount of surface segregation was dependent on the polarity of the polymer. NEXAFS also revealed that the PAG surface fraction was reduced after a postexposure bake. In the absence of delay times between processing steps, the PAG surface enhancement led to a faster deprotection reaction rate near the air interface relative to the bulk. However, when significant postexposure delay times were incorporated into the processing, NEXAFS showed that the surface deprotection reaction was incomplete after postexposure baking. Comparison of carbon K-edge, and oxygen K-edge NEXAFS spectra showed that the incomplete surface reaction was localized at the air interface. While delay effects have previously been linked to deterioration of resist performance, NEXAFS proved to be a valuable tool for providing detailed chemical specificity about the resist surface composition and deprotection kinetics.