Bryann Bromley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bryann Bromley has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Thomas D. Shipp
6 shared publicationsBeryl R. Benacerraf
4 shared publicationsYvette Groszmann
Diagnostic Ultrasound Associates, PC, Boston, Massachusetts USA (B.R.B., Y.G., B.B.); and Departments of Radiology (B.R.B., B.B.) and Obstetrics and Gynecology (B.R.B., Y.G., M.D.H., B.B.), Brigham and Women's Hospital, and Department of Obstetrics and Gynecology, Massachusetts General Hospital (B.R.B., B.B.), Harvard Medical School, Boston, Massachusetts USA
3 shared publicationsB R Benacerraf
2 shared publicationsBryann Bromley
Diagnostic Ultrasound Associates, PC, Boston, Massachusetts USA (B.R.B., Y.G., B.B.); and Departments of Radiology (B.R.B., B.B.) and Obstetrics and Gynecology (B.R.B., Y.G., M.D.H., B.B.), Brigham and Women's Hospital, and Department of Obstetrics and Gynecology, Massachusetts General Hospital (B.R.B., B.B.), Harvard Medical School, Boston, Massachusetts USA
2 shared publicationsJennifer Lyons
2 shared publications
Latest Publications
- 1 March 2015
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 34 (3) , 537-542
Deep Infiltrating Endometriosis of the Bowel Wall
The purpose of this study was to evaluate the appearance of deep infiltrating endometriosis of the bowel wall in the cul‐de‐sac and determine the characteristic appearance of these lesions. We searched our database between January 1, 2011, and December 31, 2013, for all patients who had sonographic findings of suspected deep infiltrating endometriosis of the bowel with obliteration of the cul‐de‐sac. The medical record of each patient was examined retrospectively for evidence of surgical confirmation of disease. The sonographic appearance, shape, and size of the bowel wall lesions were evaluated to develop criteria for deep infiltrating endometriosis of the rectosigmoid and cul‐de‐sac. The search of our database revealed 35 patients with sonographic findings of pelvic bowel wall endometriosis associated with obliteration of the cul‐de‐sac. Ten of these patients had surgical confirmation of bowel wall endometriosis after the scan, and another 4 patients had surgical evidence of endometriosis from prior surgery. All of the patients who underwent surgery subsequent to sonography had confirmation of their bowel wall infiltrative endometriosis. Sonographically, the bowel lesions were solid, focal, and tubular with slightly irregular margins and in most cases a thinner section or a “tail” at one end, resembling a comet. This study confirms that bowel wall implants have a very characteristic appearance, and extending the transvaginal examination to include an evaluation of the rectosigmoid seeking these bowel lesions is valuable, especially in any patient presenting with a history of pelvic pain.
- 1 March 2015
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 34 (3) , 537-542
Deep Infiltrating Endometriosis of the Bowel Wall
The purpose of this study was to evaluate the appearance of deep infiltrating endometriosis of the bowel wall in the cul‐de‐sac and determine the characteristic appearance of these lesions. We searched our database between January 1, 2011, and December 31, 2013, for all patients who had sonographic findings of suspected deep infiltrating endometriosis of the bowel with obliteration of the cul‐de‐sac. The medical record of each patient was examined retrospectively for evidence of surgical confirmation of disease. The sonographic appearance, shape, and size of the bowel wall lesions were evaluated to develop criteria for deep infiltrating endometriosis of the rectosigmoid and cul‐de‐sac. The search of our database revealed 35 patients with sonographic findings of pelvic bowel wall endometriosis associated with obliteration of the cul‐de‐sac. Ten of these patients had surgical confirmation of bowel wall endometriosis after the scan, and another 4 patients had surgical evidence of endometriosis from prior surgery. All of the patients who underwent surgery subsequent to sonography had confirmation of their bowel wall infiltrative endometriosis. Sonographically, the bowel lesions were solid, focal, and tubular with slightly irregular margins and in most cases a thinner section or a “tail” at one end, resembling a comet. This study confirms that bowel wall implants have a very characteristic appearance, and extending the transvaginal examination to include an evaluation of the rectosigmoid seeking these bowel lesions is valuable, especially in any patient presenting with a history of pelvic pain.
- 1 October 2014
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 33 (10) , 1747-1752
What Is the Importance of Second‐Trimester “Soft Markers” for Trisomy 21 After an 11‐ to 14‐Week Aneuploidy Screening Scan?
Objectives—The purpose of this study was to evaluate the importance of second-trimester “soft markers” for trisomy 21 after an 11- to 14-week aneuploidy screening scan. Methods—We conducted a retrospective cohort study of consecutive patients referred for measurement of the nuchal translucency (NT) as part of a screening protocol for aneuploidy. Patients who returned for an anatomic survey between 16 and 20 weeks’ gestation were evaluated. The sonographic markers and anomalies associated with the detection of trisomy 21 in the second trimester were analyzed. Results—There were 42 fetuses (0.4%) with trisomy 21 identified in the study cohort of 9692 patients. Trisomy 21 was suspected at the NT scan in 28 fetuses (67%) and at the second-trimester anatomic survey in 14 (33%). In fetuses first suspected of having trisomy 21 in the second trimester, 9 of 14 had normal anatomic survey results, and 5 of 14 had congenital malformations. All 14 fetuses had soft markers for aneuploidy. A thickened nuchal fold was identified in 5 of 9 fetuses with trisomy 21 and normal anatomic survey results, all of whom had an NT of less than 3.0 mm at the initial screening scan. Conclusions—Second-trimester soft markers, especially a thickened nuchal fold, remain important observations in the detection of trisomy 21 by sonography among fetuses who have had first-trimester sonographic screening for aneuploidy.
- 1 October 2014
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 33 (10) , 1747-1752
What Is the Importance of Second‐Trimester “Soft Markers” for Trisomy 21 After an 11‐ to 14‐Week Aneuploidy Screening Scan?
Objectives—The purpose of this study was to evaluate the importance of second-trimester “soft markers” for trisomy 21 after an 11- to 14-week aneuploidy screening scan. Methods—We conducted a retrospective cohort study of consecutive patients referred for measurement of the nuchal translucency (NT) as part of a screening protocol for aneuploidy. Patients who returned for an anatomic survey between 16 and 20 weeks’ gestation were evaluated. The sonographic markers and anomalies associated with the detection of trisomy 21 in the second trimester were analyzed. Results—There were 42 fetuses (0.4%) with trisomy 21 identified in the study cohort of 9692 patients. Trisomy 21 was suspected at the NT scan in 28 fetuses (67%) and at the second-trimester anatomic survey in 14 (33%). In fetuses first suspected of having trisomy 21 in the second trimester, 9 of 14 had normal anatomic survey results, and 5 of 14 had congenital malformations. All 14 fetuses had soft markers for aneuploidy. A thickened nuchal fold was identified in 5 of 9 fetuses with trisomy 21 and normal anatomic survey results, all of whom had an NT of less than 3.0 mm at the initial screening scan. Conclusions—Second-trimester soft markers, especially a thickened nuchal fold, remain important observations in the detection of trisomy 21 by sonography among fetuses who have had first-trimester sonographic screening for aneuploidy.
- 1 October 2014
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 33 (10) , 1737-1745
Detection of Fetal Structural Anomalies in a Basic First‐Trimester Screening Program for Aneuploidy
Objectives—The purpose of this study was to determine whether first-trimester aneuploidy screening sonography initially performed by credentialed sonographers was useful for detecting fetal anomalies between 11 and 14 weeks’ gestation. Methods—We conducted a retrospective cohort study of consecutive patients referred to a private ultrasound facility between January 1, 2008, and June 30, 2012, for measurement of the nuchal translucency (NT) and crown-rump length as part of a screening protocol for aneuploidy. Patients were included if there was at least 1 live fetus with a crown-rump length between 34 and 84 mm. No specific anatomic imaging protocol was followed. The presence of anomalies was based on the sonographic report and review of the medical record. The absence of anomalies was based on the report from the anatomic survey. Anomalies were categorized as lethal, major, and minor. The anomaly category and gestational age at diagnosis (≤14 versus >14 weeks) were compared. Results—An NT scan was performed on 9692 fetuses. Anatomic surveys were done on 9077 (93.7%) of these fetuses at a mean of 18 weeks’ gestation. Anomalies were detected in 180 fetuses (1.8%): 50 (0.5%) at the NT scan and 130 (1.3%) at the anatomic scan. Overall, 46 of 111 fetuses (41.4%) with major or lethal anomalies were detected at the NT scan. Two suspected abnormalities at the NT scan were not present at the anatomic scan. Conclusions—First-trimester aneuploidy screening sonography initially performed by credentialed sonographers can identify a substantial proportion of major and lethal anomalies.
- 1 October 2014
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 33 (10) , 1737-1745
Detection of Fetal Structural Anomalies in a Basic First‐Trimester Screening Program for Aneuploidy
Objectives—The purpose of this study was to determine whether first-trimester aneuploidy screening sonography initially performed by credentialed sonographers was useful for detecting fetal anomalies between 11 and 14 weeks’ gestation. Methods—We conducted a retrospective cohort study of consecutive patients referred to a private ultrasound facility between January 1, 2008, and June 30, 2012, for measurement of the nuchal translucency (NT) and crown-rump length as part of a screening protocol for aneuploidy. Patients were included if there was at least 1 live fetus with a crown-rump length between 34 and 84 mm. No specific anatomic imaging protocol was followed. The presence of anomalies was based on the sonographic report and review of the medical record. The absence of anomalies was based on the report from the anatomic survey. Anomalies were categorized as lethal, major, and minor. The anomaly category and gestational age at diagnosis (≤14 versus >14 weeks) were compared. Results—An NT scan was performed on 9692 fetuses. Anatomic surveys were done on 9077 (93.7%) of these fetuses at a mean of 18 weeks’ gestation. Anomalies were detected in 180 fetuses (1.8%): 50 (0.5%) at the NT scan and 130 (1.3%) at the anatomic scan. Overall, 46 of 111 fetuses (41.4%) with major or lethal anomalies were detected at the NT scan. Two suspected abnormalities at the NT scan were not present at the anatomic scan. Conclusions—First-trimester aneuploidy screening sonography initially performed by credentialed sonographers can identify a substantial proportion of major and lethal anomalies.
- Open Access
- 1 July 2014
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 33 (7) , 1209-1214
Do Clinical Practitioners Seeking Credentialing for Nuchal Translucency Measurement Demonstrate Compliance With Biosafety Recommendations?
- 1 July 2014
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 33 (7) , 1209-1214
Open AccessDo Clinical Practitioners Seeking Credentialing for Nuchal Translucency Measurement Demonstrate Compliance With Biosafety Recommendations?
- 1 October 2013
- Published by Elsevier in Seminars in Perinatology
- Vol. 37 (5) , 345-347
The use of obstetrical ultrasound in the obese gravida
- 1 October 2013
- Published by Elsevier in Seminars in Perinatology
- Vol. 37 (5) , 345-347
The use of obstetrical ultrasound in the obese gravida
- Open Access
- 1 August 2010
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 29 (8) , 1261-1264
Tricks for obtaining a nuchal translucency measurement on the fetus in a difficult position.
- 1 August 2010
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 29 (8) , 1261-1264
Open AccessTricks for obtaining a nuchal translucency measurement on the fetus in a difficult position.
- 22 June 2010
- Published by Wiley in Prenatal Diagnosis
- Vol. 30 (7) , 644-652
The history of the second‐trimester sonographic markers for detecting fetal Down syndrome, and their current role in obstetric practice
This review summarizes the development, history and use of second‐trimester sonographic markers for the detection of fetal Down syndrome over three decades. Starting with the nuchal fold thickening in 1985 and culminating in the genetic sonogram in the 1990s. The combination of second‐trimester serum screening with the ultrasound markers improved the detection rate of affected fetuses but also allowed patients to decrease their risk of carrying a fetus with Down syndrome if the genetic sonogram was normal. More recently the role of the genetic sonogram and its markers have changed with the wide spread use of first‐trimester screening. This prior screening ultimately decreases the prevalence of fetal Down syndrome in the second trimester to less than 85% of what it was in the first‐trimester as most fetuses with Down syndrome are now identified early. Current interpretation of the second‐trimester Down syndrome markers must be based on the result of the first trimester and combined screening to achieve the most accurate risk estimate of an affected fetus. Copyright © 2010 John Wiley & Sons, Ltd.
- 22 June 2010
- Published by Wiley in Prenatal Diagnosis
- Vol. 30 (7) , 644-652
The history of the second‐trimester sonographic markers for detecting fetal Down syndrome, and their current role in obstetric practice
This review summarizes the development, history and use of second‐trimester sonographic markers for the detection of fetal Down syndrome over three decades. Starting with the nuchal fold thickening in 1985 and culminating in the genetic sonogram in the 1990s. The combination of second‐trimester serum screening with the ultrasound markers improved the detection rate of affected fetuses but also allowed patients to decrease their risk of carrying a fetus with Down syndrome if the genetic sonogram was normal. More recently the role of the genetic sonogram and its markers have changed with the wide spread use of first‐trimester screening. This prior screening ultimately decreases the prevalence of fetal Down syndrome in the second trimester to less than 85% of what it was in the first‐trimester as most fetuses with Down syndrome are now identified early. Current interpretation of the second‐trimester Down syndrome markers must be based on the result of the first trimester and combined screening to achieve the most accurate risk estimate of an affected fetus. Copyright © 2010 John Wiley & Sons, Ltd.
- Open Access
- 1 March 2010
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 29 (3) , 445-453
Structural Anomalies in Early Embryonic Death
- 1 March 2010
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 29 (3) , 445-453
Open AccessStructural Anomalies in Early Embryonic Death
- Open Access
- 5 January 2010
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 35 (5) , 615-616
A technical tip on scanning obese gravidae
How do we do it?Practical advice on imaging‐based techniques and investigations
- 5 January 2010
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 35 (5) , 615-616
Open AccessA technical tip on scanning obese gravidae
How do we do it?Practical advice on imaging‐based techniques and investigations
- 29 June 2009
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 34 (1) , 110-115
Three‐dimensional ultrasound detection of abnormally located intrauterine contraceptive devices which are a source of pelvic pain and abnormal bleeding
Objective: To determine whether intrauterine contraceptive devices (IUDs) that are located abnormally within the myometrium or cervix cause a higher incidence of pelvic pain and abnormal bleeding compared with normally positioned devices.Methods: Over a period of 9 months, all patients with an IUD presenting at our unit for two‐dimensional pelvic ultrasound underwent a three‐dimensional (3D) volume reconstruction of the coronal view, to visualize the entire IUD within the cavity. The IUD was deemed malpositioned if any part extended past the cavity, into the myometrium or cervix. The indications for ultrasound were recorded at presentation for the exam. The presenting symptoms of patients with an abnormally located IUD were compared with those with normally positioned ones.Results: Among 167 consecutive patients with an IUD evaluated using the 3D reconstructed coronal view, 28 (16.8%) had an IUD with side arms abnormally located within the myometrium. The abnormal positioning of the IUD arms was only detected using the 3D coronal view. A higher proportion of patients with an abnormally located IUD presented with bleeding (35.7%) or pain (39.3%) compared with those with normally positioned IUDs (15.1% with bleeding and 19.4% with pain) (P = 0.02 and 0.03, respectively). Seventy‐five percent of patients with an abnormally located IUD presented with bleeding or pain compared with 34.5% of those whose IUD was normally placed (P = 0.0001). Twenty of 21 patients with an abnormally located IUD presenting with pelvic pain or bleeding reported improvement in their symptoms after IUD removal.Conclusion: A 3D coronal view of the uterus is useful in the visualization of IUDs. The coronal view showing the entire device and its position within the uterus may help in identifying the cause of pelvic pain and bleeding in patients with an embedded IUD. Copyright © 2009 ISUOG. Published by John Wiley & Sons, Ltd.
- 29 June 2009
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 34 (1) , 110-115
Three‐dimensional ultrasound detection of abnormally located intrauterine contraceptive devices which are a source of pelvic pain and abnormal bleeding
Objective: To determine whether intrauterine contraceptive devices (IUDs) that are located abnormally within the myometrium or cervix cause a higher incidence of pelvic pain and abnormal bleeding compared with normally positioned devices.Methods: Over a period of 9 months, all patients with an IUD presenting at our unit for two‐dimensional pelvic ultrasound underwent a three‐dimensional (3D) volume reconstruction of the coronal view, to visualize the entire IUD within the cavity. The IUD was deemed malpositioned if any part extended past the cavity, into the myometrium or cervix. The indications for ultrasound were recorded at presentation for the exam. The presenting symptoms of patients with an abnormally located IUD were compared with those with normally positioned ones.Results: Among 167 consecutive patients with an IUD evaluated using the 3D reconstructed coronal view, 28 (16.8%) had an IUD with side arms abnormally located within the myometrium. The abnormal positioning of the IUD arms was only detected using the 3D coronal view. A higher proportion of patients with an abnormally located IUD presented with bleeding (35.7%) or pain (39.3%) compared with those with normally positioned IUDs (15.1% with bleeding and 19.4% with pain) (P = 0.02 and 0.03, respectively). Seventy‐five percent of patients with an abnormally located IUD presented with bleeding or pain compared with 34.5% of those whose IUD was normally placed (P = 0.0001). Twenty of 21 patients with an abnormally located IUD presenting with pelvic pain or bleeding reported improvement in their symptoms after IUD removal.Conclusion: A 3D coronal view of the uterus is useful in the visualization of IUDs. The coronal view showing the entire device and its position within the uterus may help in identifying the cause of pelvic pain and bleeding in patients with an embedded IUD. Copyright © 2009 ISUOG. Published by John Wiley & Sons, Ltd.