JHJussi Hiltunen

Jussi Hiltunen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jussi Hiltunen has a total of 89 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Semiquantitative Lateral Flow Assay Using a Handheld Device With a Transmissive Readout

    by Daniel Nguyen, Iida Jääskeläinen, Duc Le, Anu Mursula, Sanna Aikio, Christina Liedert, Jussi Hiltunen

  • sNails: sweat-sensing nails for unobtrusive, wearable microfluidic sweat monitoring from the dorsal distal phalanges

    by Noelle Davis, Pooja Mehta, Amanda Kang, Liam Gillan, Jussi Hiltunen, Ali Javey

    We present a fingernail-mounted microfluidic sweat sensor, the sNail, that leverages the anatomical and mechanical advantages of the nail plate and adjacent dorsal finger skin—regions that are uniquely stiff and stable yet underutilized for wearable biosensing. In contrast to fully soft, skin-mounted sensors, our device exploits the rigidity of the nail to host microfluidics that remain stable under typical daily finger motion. The platform incorporates a hydrogel-filled sweat collection well and stretchable thermoplastic polyurethane (TPU) microfluidics, fabricated via scalable laserjet printing and laser cutting. We demonstrate frequent sweat rate monitoring across multiple fingers and subjects during activities ranging from walking to typing, and capture dynamic changes in sweat rate associated with both physical exertion and psychological stress. This nail-mounted approach enables unobtrusive, informative sweat biosensing, paving the way for broader adoption in everyday settings.


  • Reusable, Fully Integrated Sweat Monitor Band with Peel‐and‐Stick‐Replacement Printed Microfluidic Sensor

    by Noelle Davis, Amanda Kang, Elina Hakola, Liam Gillan, Yifei Zhan, Jussi Hiltunen, Ali Javey

    This paper presents a continuous monitor for local sweat rate consisting of a fully reusable, wearable band with an integrated electronics module and a disposable, peel‐and‐stick‐replacement microfluidic sensor with printed electrodes. Local sweat rate sensors on specific skin sites have the potential to inform hydration strategies, with many devices recently introduced in the academic domain and even a few in the commercial domain. Here, several challenges in the design of sweat sensing systems are addressed: high reusability with minimal single‐use material, robust interfacing with the single‐use component in both electrical and fluidic pathways, implementation of scalable, roll‐to‐roll screen printing processes, and integration of precise measurements with continuous, wireless readout. Finally, the device is demonstrated on‐body during environmental heat and cycling exercise. In the near future, it is expected that this device will enable the academic study of sweat rate, and eventually, help make this biometric accessible to those such as workers and athletes in harsh environments.


  • Top Cited Papers

    Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities

    by Seung-Rok Kim, Yifei Zhan, Noelle Davis, Suhrith Bellamkonda, Liam Gillan, Elina Hakola, Jussi Hiltunen, Ali Javey


  • Open Access

    Wearable Upper Arm SpO2 Sensor for Wellness Monitoring

    by Matti T. Kinnunen, Mohammad H. Behfar, Nuutti Santaniemi, Tuomas Happonen, Dung Nguyen, Joni Kilpijärvi, Tommi Jaako, Jukka Happonen, Monica K. Russell, Christian A. Clermont, et al.

    Objective: This paper describes the full development of a sensor for measuring optical heart rate (OHR) and blood oxygen saturation (SpO2). Methods: A wearable sensor with a new type of skin compatible dispensed lens was designed and manufactured. All critical optical components, light emitting diodes (LEDs) and photodiode (PD) were close to skin and gave maximum light intensity due to minimal loss in the lens structure. Lens and optical components formed a thin monolithic structure. Results: Suppressed crosstalk between LED and PD was achieved by using two types of dispensed material: light blocking and transparent. High signal to noise ratio (SNR) and amplitude in the alternating current (AC) part of the photoplethysmography (PPG) signal were achieved. User comfort was achieved by having a small sensor located on the upper arm. When re-training the algorithm from our first iteration, the multiwavelength PPG sensor showed an SpO2 RMSE of 2.61% with a 7-second average analysis for 25 participants. The average RMSE of heart rate over all 25 participants was 1.6 ± 1.1%. Conclusion: This study demonstrates a sensor with a clinical grade SpO2 measurement and a highly accurate OHR measurement that is also comfortable and easy to wear. Significance: A dispensing method provides a new way of manufacturing sensor elements for wearable sensors with increased performance with reduced crosstalk.


  • Open Access

    Roll to Roll Imprinting PDMS Microstructures Under Reduced Ambient Pressures

    by Olli-Heikki Huttunen, Johanna Hiitola-Keinänen, Jarno Petäjä, Eero Hietala, Hannu Lindström, Jussi Hiltunen

    High-volume manufacturing of microstructures is essential for the uptake of the related scientific results for commercial use and also if hundreds or thousands of devices with repeatable performance are needed during the large-scale experimental research. Polydimethyl siloxane (PDMS) is one of the most widely used materials for academia to prepare microfluidic test devices. This has also motivated the development of roll-to-roll imprinting towards the fabrication of PDMS-based devices at high volumes. The gas bubble entrapping during the replication process has remained an issue resulting in defects in the microstructure. Performing imprinting in vacuum is a well-known method to avoid bubbles but it has not been applied in roll-to-roll processing. In this work we demonstrated a reduced ambient pressure roll to roll imprinting process using PDMS silicone elastomer as imprint resist. We observed the reduction in the number of bubble-originated defects in individual micro-features from 100 % to $<$ 1 % when the ambient pressure was reduced from 1 atm to 1/8 atm. 2023-0063


  • Open Access

    Biodegradable Cellulose Nanocomposite Substrate for Recyclable Flexible Printed Electronics

    by Aayush Kumar Jaiswal, Vinay Kumar, Elina Jansson, Olli‐Heikki Huttunen, Akio Yamamoto, Minna Vikman, Alexey Khakalo, Jussi Hiltunen, Mohammad H. Behfar

    Printed, flexible, and hybrid electronic technologies are advancing rapidly leading to remarkable developments in smart wearables, intelligent textiles, and health monitoring systems. Flexible electronics are typically fabricated on petroleum‐derived polymeric substrates. However, in the light of global environmental concerns regarding fossil raw materials, there is a need to drive the production of flexible electronics devices based on sustainable materials. Additionally, there is a need to reduce the quantity of electronic waste by developing material recovery and recycling technologies. Here, a fully biobased and biodegradable substrate tailored for printed flexible electronic applications is developed. Based on a nanocomposite of cellulose nanofibril (CNF) and hydroxyethyl cellulose (HEC), the substrate shows excellent mechanical and optical properties for printed flexible electronics applications. High‐resolution screen printing of conductive ink and typical electronics assembly processes are possible to realize on the substrate. An electrocardiograph (ECG) device is fabricated on the cellulosic substrate as a technology demonstrator and its performance is confirmed on human volunteers. Last, end‐of‐life scenarios are studied for printed electronic devices where device degradation and subsequent material recovery concepts are presented. This work demonstrates that sustainable plant‐derived materials can play a big role toward a green transition in the electronics industry.


  • Photonics integrated circuits from innovations to commercial solutions: MedPhab pilot line for accelerated industrial uptake

    by Jussi A. Hiltunen

    Medical device industry is a rapidly growing area providing significant opportunities for the photonics technology suppliers. The heterogeneous nature of photonics and lack of available fabrication processes with medical certificates set challenges for a rapid adaption of the latest photonics technologies. The aim of MedPhab photonics pilot line is to establish seamless research and development chains between research organization and industry accelerating the product launch in regulated domain.

  • Open Access

    Advances in design and manufacture of stretchable electronics

    by Liam Gillan, Jussi Hiltunen, Mohammad H. Behfar, Kari Rönkä

    Flexible and stretchable electronics present opportunities for transition from rigid bulky devices to soft and conformal systems. However, such technology requires mechanical design and integration strategies to enhance robustness and form factor. In addition, scalable and reliable fabrication pathways are needed to facilitate the high volume manufacturing required to satisfy a growing market demand. This report describes recent advances in design, manufacture, and reliability of flexible and stretchable electronics technology. Flexible concept devices for physiological monitoring are introduced, before discussion of high throughput fabrication of stretchable electronics, then hybrid integration of conventional rigid components on stretchable carrier substrates with an emphasis on a need for further developments in device reliability testing procedures. Finally, consideration is given to transition options for more eco-conscious device constituents. These cases progress flexible and stretchable electronics towards robust, fully integrated, unobtrusive devices incorporating sustainable components.