Jussi Hiltunen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jussi Hiltunen has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
J. Lappalainen
Microelectronics and Materials Physics Laboratories, EMPART Research Group of Infotech Oulu , University of Oulu , Linnanmaa, FIN-90570, Oulu, Finland
5 shared publicationsV. Lantto
Microelectronics and Materials Physics Laboratories, EMPART Research Group of Infotech Oulu , University of Oulu , Linnanmaa, FIN-90570, Oulu, Finland
5 shared publicationsJ. Puustinen
Microelectronics and Materials Physics Laboratories, University of Oulu, FIN‐900014, Finland
4 shared publications- Liam Gillan
VTT Technical Research Centre of Finland Ltd, Espoo, Finland
4 shared publications - Mohammad H. Behfar
VTT Technical Research Centre of Finland, Espoo, Finland
4 shared publications - Sanna Aikio
VTT Technical Research Centre of Finland, Oulu, Finland
4 shared publications
Latest Publications
- Open Access
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 1915-1922
Semiquantitative Lateral Flow Assay Using a Handheld Device With a Transmissive Readout
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 1915-1922
Open AccessSemiquantitative Lateral Flow Assay Using a Handheld Device With a Transmissive Readout
- 24 September 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (21) , 5473-5481
sNails: sweat-sensing nails for unobtrusive, wearable microfluidic sweat monitoring from the dorsal distal phalanges
We present a fingernail-mounted microfluidic sweat sensor, the sNail, that leverages the anatomical and mechanical advantages of the nail plate and adjacent dorsal finger skin—regions that are uniquely stiff and stable yet underutilized for wearable biosensing. In contrast to fully soft, skin-mounted sensors, our device exploits the rigidity of the nail to host microfluidics that remain stable under typical daily finger motion. The platform incorporates a hydrogel-filled sweat collection well and stretchable thermoplastic polyurethane (TPU) microfluidics, fabricated via scalable laserjet printing and laser cutting. We demonstrate frequent sweat rate monitoring across multiple fingers and subjects during activities ranging from walking to typing, and capture dynamic changes in sweat rate associated with both physical exertion and psychological stress. This nail-mounted approach enables unobtrusive, informative sweat biosensing, paving the way for broader adoption in everyday settings.
- 24 September 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (21) , 5473-5481
sNails: sweat-sensing nails for unobtrusive, wearable microfluidic sweat monitoring from the dorsal distal phalanges
We present a fingernail-mounted microfluidic sweat sensor, the sNail, that leverages the anatomical and mechanical advantages of the nail plate and adjacent dorsal finger skin—regions that are uniquely stiff and stable yet underutilized for wearable biosensing. In contrast to fully soft, skin-mounted sensors, our device exploits the rigidity of the nail to host microfluidics that remain stable under typical daily finger motion. The platform incorporates a hydrogel-filled sweat collection well and stretchable thermoplastic polyurethane (TPU) microfluidics, fabricated via scalable laserjet printing and laser cutting. We demonstrate frequent sweat rate monitoring across multiple fingers and subjects during activities ranging from walking to typing, and capture dynamic changes in sweat rate associated with both physical exertion and psychological stress. This nail-mounted approach enables unobtrusive, informative sweat biosensing, paving the way for broader adoption in everyday settings.
- 20 May 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (16)
Reusable, Fully Integrated Sweat Monitor Band with Peel‐and‐Stick‐Replacement Printed Microfluidic Sensor
This paper presents a continuous monitor for local sweat rate consisting of a fully reusable, wearable band with an integrated electronics module and a disposable, peel‐and‐stick‐replacement microfluidic sensor with printed electrodes. Local sweat rate sensors on specific skin sites have the potential to inform hydration strategies, with many devices recently introduced in the academic domain and even a few in the commercial domain. Here, several challenges in the design of sweat sensing systems are addressed: high reusability with minimal single‐use material, robust interfacing with the single‐use component in both electrical and fluidic pathways, implementation of scalable, roll‐to‐roll screen printing processes, and integration of precise measurements with continuous, wireless readout. Finally, the device is demonstrated on‐body during environmental heat and cycling exercise. In the near future, it is expected that this device will enable the academic study of sweat rate, and eventually, help make this biometric accessible to those such as workers and athletes in harsh environments.
- 20 May 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 10 (16)
Reusable, Fully Integrated Sweat Monitor Band with Peel‐and‐Stick‐Replacement Printed Microfluidic Sensor
This paper presents a continuous monitor for local sweat rate consisting of a fully reusable, wearable band with an integrated electronics module and a disposable, peel‐and‐stick‐replacement microfluidic sensor with printed electrodes. Local sweat rate sensors on specific skin sites have the potential to inform hydration strategies, with many devices recently introduced in the academic domain and even a few in the commercial domain. Here, several challenges in the design of sweat sensing systems are addressed: high reusability with minimal single‐use material, robust interfacing with the single‐use component in both electrical and fluidic pathways, implementation of scalable, roll‐to‐roll screen printing processes, and integration of precise measurements with continuous, wireless readout. Finally, the device is demonstrated on‐body during environmental heat and cycling exercise. In the near future, it is expected that this device will enable the academic study of sweat rate, and eventually, help make this biometric accessible to those such as workers and athletes in harsh environments.
- Top Cited Papers
- 1 April 2025
- Published by Springer Nature in Nature Electronics
- Vol. 8 (4) , 353-361
Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities
- 1 April 2025
- Published by Springer Nature in Nature Electronics
- Vol. 8 (4) , 353-361
Top Cited PapersElectrodermal activity as a proxy for sweat rate monitoring during physical and mental activities
- Open Access
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1766-1774
Wearable Upper Arm SpO2 Sensor for Wellness Monitoring
Objective: This paper describes the full development of a sensor for measuring optical heart rate (OHR) and blood oxygen saturation (SpO2). Methods: A wearable sensor with a new type of skin compatible dispensed lens was designed and manufactured. All critical optical components, light emitting diodes (LEDs) and photodiode (PD) were close to skin and gave maximum light intensity due to minimal loss in the lens structure. Lens and optical components formed a thin monolithic structure. Results: Suppressed crosstalk between LED and PD was achieved by using two types of dispensed material: light blocking and transparent. High signal to noise ratio (SNR) and amplitude in the alternating current (AC) part of the photoplethysmography (PPG) signal were achieved. User comfort was achieved by having a small sensor located on the upper arm. When re-training the algorithm from our first iteration, the multiwavelength PPG sensor showed an SpO2 RMSE of 2.61% with a 7-second average analysis for 25 participants. The average RMSE of heart rate over all 25 participants was 1.6 ± 1.1%. Conclusion: This study demonstrates a sensor with a clinical grade SpO2 measurement and a highly accurate OHR measurement that is also comfortable and easy to wear. Significance: A dispensing method provides a new way of manufacturing sensor elements for wearable sensors with increased performance with reduced crosstalk.
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1766-1774
Open AccessWearable Upper Arm SpO2 Sensor for Wellness Monitoring
Objective: This paper describes the full development of a sensor for measuring optical heart rate (OHR) and blood oxygen saturation (SpO2). Methods: A wearable sensor with a new type of skin compatible dispensed lens was designed and manufactured. All critical optical components, light emitting diodes (LEDs) and photodiode (PD) were close to skin and gave maximum light intensity due to minimal loss in the lens structure. Lens and optical components formed a thin monolithic structure. Results: Suppressed crosstalk between LED and PD was achieved by using two types of dispensed material: light blocking and transparent. High signal to noise ratio (SNR) and amplitude in the alternating current (AC) part of the photoplethysmography (PPG) signal were achieved. User comfort was achieved by having a small sensor located on the upper arm. When re-training the algorithm from our first iteration, the multiwavelength PPG sensor showed an SpO2 RMSE of 2.61% with a 7-second average analysis for 25 participants. The average RMSE of heart rate over all 25 participants was 1.6 ± 1.1%. Conclusion: This study demonstrates a sensor with a clinical grade SpO2 measurement and a highly accurate OHR measurement that is also comfortable and easy to wear. Significance: A dispensing method provides a new way of manufacturing sensor elements for wearable sensors with increased performance with reduced crosstalk.
- Open Access
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (1) , 95-101
Roll to Roll Imprinting PDMS Microstructures Under Reduced Ambient Pressures
High-volume manufacturing of microstructures is essential for the uptake of the related scientific results for commercial use and also if hundreds or thousands of devices with repeatable performance are needed during the large-scale experimental research. Polydimethyl siloxane (PDMS) is one of the most widely used materials for academia to prepare microfluidic test devices. This has also motivated the development of roll-to-roll imprinting towards the fabrication of PDMS-based devices at high volumes. The gas bubble entrapping during the replication process has remained an issue resulting in defects in the microstructure. Performing imprinting in vacuum is a well-known method to avoid bubbles but it has not been applied in roll-to-roll processing. In this work we demonstrated a reduced ambient pressure roll to roll imprinting process using PDMS silicone elastomer as imprint resist. We observed the reduction in the number of bubble-originated defects in individual micro-features from 100 % to $<$ 1 % when the ambient pressure was reduced from 1 atm to 1/8 atm. 2023-0063
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (1) , 95-101
Open AccessRoll to Roll Imprinting PDMS Microstructures Under Reduced Ambient Pressures
High-volume manufacturing of microstructures is essential for the uptake of the related scientific results for commercial use and also if hundreds or thousands of devices with repeatable performance are needed during the large-scale experimental research. Polydimethyl siloxane (PDMS) is one of the most widely used materials for academia to prepare microfluidic test devices. This has also motivated the development of roll-to-roll imprinting towards the fabrication of PDMS-based devices at high volumes. The gas bubble entrapping during the replication process has remained an issue resulting in defects in the microstructure. Performing imprinting in vacuum is a well-known method to avoid bubbles but it has not been applied in roll-to-roll processing. In this work we demonstrated a reduced ambient pressure roll to roll imprinting process using PDMS silicone elastomer as imprint resist. We observed the reduction in the number of bubble-originated defects in individual micro-features from 100 % to $<$ 1 % when the ambient pressure was reduced from 1 atm to 1/8 atm. 2023-0063
- 14 August 2023
- Published by Springer Nature in Nature Electronics
- Vol. 6 (8) , 557-558
Continuous sweat monitoring on the go
- 14 August 2023
- Published by Springer Nature in Nature Electronics
- Vol. 6 (8) , 557-558
Continuous sweat monitoring on the go
- Open Access
- 29 January 2023
- Published by Wiley in Advanced Electronic Materials
- Vol. 9 (4)
Biodegradable Cellulose Nanocomposite Substrate for Recyclable Flexible Printed Electronics
Printed, flexible, and hybrid electronic technologies are advancing rapidly leading to remarkable developments in smart wearables, intelligent textiles, and health monitoring systems. Flexible electronics are typically fabricated on petroleum‐derived polymeric substrates. However, in the light of global environmental concerns regarding fossil raw materials, there is a need to drive the production of flexible electronics devices based on sustainable materials. Additionally, there is a need to reduce the quantity of electronic waste by developing material recovery and recycling technologies. Here, a fully biobased and biodegradable substrate tailored for printed flexible electronic applications is developed. Based on a nanocomposite of cellulose nanofibril (CNF) and hydroxyethyl cellulose (HEC), the substrate shows excellent mechanical and optical properties for printed flexible electronics applications. High‐resolution screen printing of conductive ink and typical electronics assembly processes are possible to realize on the substrate. An electrocardiograph (ECG) device is fabricated on the cellulosic substrate as a technology demonstrator and its performance is confirmed on human volunteers. Last, end‐of‐life scenarios are studied for printed electronic devices where device degradation and subsequent material recovery concepts are presented. This work demonstrates that sustainable plant‐derived materials can play a big role toward a green transition in the electronics industry.
- 29 January 2023
- Published by Wiley in Advanced Electronic Materials
- Vol. 9 (4)
Open AccessBiodegradable Cellulose Nanocomposite Substrate for Recyclable Flexible Printed Electronics
Printed, flexible, and hybrid electronic technologies are advancing rapidly leading to remarkable developments in smart wearables, intelligent textiles, and health monitoring systems. Flexible electronics are typically fabricated on petroleum‐derived polymeric substrates. However, in the light of global environmental concerns regarding fossil raw materials, there is a need to drive the production of flexible electronics devices based on sustainable materials. Additionally, there is a need to reduce the quantity of electronic waste by developing material recovery and recycling technologies. Here, a fully biobased and biodegradable substrate tailored for printed flexible electronic applications is developed. Based on a nanocomposite of cellulose nanofibril (CNF) and hydroxyethyl cellulose (HEC), the substrate shows excellent mechanical and optical properties for printed flexible electronics applications. High‐resolution screen printing of conductive ink and typical electronics assembly processes are possible to realize on the substrate. An electrocardiograph (ECG) device is fabricated on the cellulosic substrate as a technology demonstrator and its performance is confirmed on human volunteers. Last, end‐of‐life scenarios are studied for printed electronic devices where device degradation and subsequent material recovery concepts are presented. This work demonstrates that sustainable plant‐derived materials can play a big role toward a green transition in the electronics industry.
- 26 May 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12148, 93-96
Photonics integrated circuits from innovations to commercial solutions: MedPhab pilot line for accelerated industrial uptake
Medical device industry is a rapidly growing area providing significant opportunities for the photonics technology suppliers. The heterogeneous nature of photonics and lack of available fabrication processes with medical certificates set challenges for a rapid adaption of the latest photonics technologies. The aim of MedPhab photonics pilot line is to establish seamless research and development chains between research organization and industry accelerating the product launch in regulated domain.
- 26 May 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12148, 93-96
Photonics integrated circuits from innovations to commercial solutions: MedPhab pilot line for accelerated industrial uptake
Medical device industry is a rapidly growing area providing significant opportunities for the photonics technology suppliers. The heterogeneous nature of photonics and lack of available fabrication processes with medical certificates set challenges for a rapid adaption of the latest photonics technologies. The aim of MedPhab photonics pilot line is to establish seamless research and development chains between research organization and industry accelerating the product launch in regulated domain.
- Open Access
- 19 April 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SE) , SE0804
Advances in design and manufacture of stretchable electronics
Flexible and stretchable electronics present opportunities for transition from rigid bulky devices to soft and conformal systems. However, such technology requires mechanical design and integration strategies to enhance robustness and form factor. In addition, scalable and reliable fabrication pathways are needed to facilitate the high volume manufacturing required to satisfy a growing market demand. This report describes recent advances in design, manufacture, and reliability of flexible and stretchable electronics technology. Flexible concept devices for physiological monitoring are introduced, before discussion of high throughput fabrication of stretchable electronics, then hybrid integration of conventional rigid components on stretchable carrier substrates with an emphasis on a need for further developments in device reliability testing procedures. Finally, consideration is given to transition options for more eco-conscious device constituents. These cases progress flexible and stretchable electronics towards robust, fully integrated, unobtrusive devices incorporating sustainable components.
- 19 April 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SE) , SE0804
Open AccessAdvances in design and manufacture of stretchable electronics
Flexible and stretchable electronics present opportunities for transition from rigid bulky devices to soft and conformal systems. However, such technology requires mechanical design and integration strategies to enhance robustness and form factor. In addition, scalable and reliable fabrication pathways are needed to facilitate the high volume manufacturing required to satisfy a growing market demand. This report describes recent advances in design, manufacture, and reliability of flexible and stretchable electronics technology. Flexible concept devices for physiological monitoring are introduced, before discussion of high throughput fabrication of stretchable electronics, then hybrid integration of conventional rigid components on stretchable carrier substrates with an emphasis on a need for further developments in device reliability testing procedures. Finally, consideration is given to transition options for more eco-conscious device constituents. These cases progress flexible and stretchable electronics towards robust, fully integrated, unobtrusive devices incorporating sustainable components.