Simon Lecler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Simon Lecler has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Luc G. Fréchette
Universit de Sherbrooke,UMI-LN2,CANADA
1 shared publication- Luc Guy Frechette
Université de Sherbrooke
1 shared publication Olivier Marconot
Universit de Sherbrooke,UMI-LN2,CANADA
1 shared publication- Olivier Marconot
Institut Interdisciplinaire d’Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, Canada
1 shared publication Pascal J. Newby
C2MI, 45 boulevard de l’Aéroport, Bromont, CANADA (QC), Pascal
1 shared publication- Pierre-Élie Weiss
ONERA
1 shared publication
Latest Publications
- Open Access
- 1 June 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (6)
Prediction of wall-pressure fluctuations for separating/reattaching flows applied to space launchers using zonal detached eddy simulation-based convolutional neural networks
Convolutional neural networks (CNNs) are used to predict the fluctuating wall-pressure coefficient and associated single-point pressure spectra in the separating/reattaching flow region around a generic space launcher configuration in the transonic regime. The neural networks are trained on a generic axisymmetric afterbody configuration. A Zonal Detached Eddy Simulation of a semi-realistic launcher geometry [NASA (National Aeronautics and Space Administration) model 11 hammerhead] is performed and validated using available experimental results. This configuration is used as a testing case for the trained models. It is shown that the CNNs are able to identify flow features related to physical phenomena of the flow. From this feature identification, the models are able to predict the evolution of fluctuating wall quantities and locate the regions of high pressure fluctuations. A scaling procedure is proposed to retrieve correct levels of the predicted quantities for a given unknown configuration having different free stream conditions. We also demonstrate that the present models perform well applied on Reynolds-Averaged Navier–Stokes mean flow fields, paving the way for a significant reduction in the computational cost for predicting wall-pressure fluctuations around space launchers.
- 1 June 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (6)
Open AccessPrediction of wall-pressure fluctuations for separating/reattaching flows applied to space launchers using zonal detached eddy simulation-based convolutional neural networks
Convolutional neural networks (CNNs) are used to predict the fluctuating wall-pressure coefficient and associated single-point pressure spectra in the separating/reattaching flow region around a generic space launcher configuration in the transonic regime. The neural networks are trained on a generic axisymmetric afterbody configuration. A Zonal Detached Eddy Simulation of a semi-realistic launcher geometry [NASA (National Aeronautics and Space Administration) model 11 hammerhead] is performed and validated using available experimental results. This configuration is used as a testing case for the trained models. It is shown that the CNNs are able to identify flow features related to physical phenomena of the flow. From this feature identification, the models are able to predict the evolution of fluctuating wall quantities and locate the regions of high pressure fluctuations. A scaling procedure is proposed to retrieve correct levels of the predicted quantities for a given unknown configuration having different free stream conditions. We also demonstrate that the present models perform well applied on Reynolds-Averaged Navier–Stokes mean flow fields, paving the way for a significant reduction in the computational cost for predicting wall-pressure fluctuations around space launchers.
- 6 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (17) , 9937-9946
Dimensionless Analysis of Micro Pirani Gauges for Broad Pressure Sensing Range
This article proposes a dimensionless thermal analysis of micro-fabricated membranes as Pirani gauges for pressure measurements. Use of dimensionless numbers simplifies the mode l and facilitates understanding. Our model’s predictions are consistent with experimental results obtained from heated suspended SiO2/SiN membranes with a sub-micrometer separation distance with the substrate (500 nm). Other systems reported in the literature also confirmed the modelling. This framework is a powerful prediction tool as it allows a study of the effects of key parameters on the sensing pressure range, including geometry, material properties and radiative heat fluxes. It also addresses the effect of the operating mode, either constant temperature or constant power. Furthermore, we propose a methodology for rapid design of Pirani gauge arrays to reach a broad range of pressure measurements from atmospheric pressure to high vacuum (10-3 Pa) without microcontroller use. We prove that this new formalism offers a way to optimize the geometry to reach the target application, which essentially depends on the power consumption, material choice and the pressure measurement range.
- 6 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (17) , 9937-9946
Dimensionless Analysis of Micro Pirani Gauges for Broad Pressure Sensing Range
This article proposes a dimensionless thermal analysis of micro-fabricated membranes as Pirani gauges for pressure measurements. Use of dimensionless numbers simplifies the mode l and facilitates understanding. Our model’s predictions are consistent with experimental results obtained from heated suspended SiO2/SiN membranes with a sub-micrometer separation distance with the substrate (500 nm). Other systems reported in the literature also confirmed the modelling. This framework is a powerful prediction tool as it allows a study of the effects of key parameters on the sensing pressure range, including geometry, material properties and radiative heat fluxes. It also addresses the effect of the operating mode, either constant temperature or constant power. Furthermore, we propose a methodology for rapid design of Pirani gauge arrays to reach a broad range of pressure measurements from atmospheric pressure to high vacuum (10-3 Pa) without microcontroller use. We prove that this new formalism offers a way to optimize the geometry to reach the target application, which essentially depends on the power consumption, material choice and the pressure measurement range.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
SiO2/SiN membranes as MEMS Pirani gauges for wide pressure measurement range
Thanks to an original surface microfabrication process, large membranes suspended 1 micron above a substrate have been elaborated. A membrane with a wide heat exchange area and such a small gap allows the gauge to be sensitive in the high vacuum regime, and ensures a broader pressure range of measurement. By optimizing the membrane and beam sizes, this paper shows that one can combine different membranes to design a packaged sensor with a wide sensitive pressure range (10 -2 to 10 5 Pa) and a very low power consumption (maximum 115 microwatt in this paper). These results allow the design of a fully integrated sensor, based on a unique technology, that can be integrated for in-situ pressure measurements in vacuum applications.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
SiO2/SiN membranes as MEMS Pirani gauges for wide pressure measurement range
Thanks to an original surface microfabrication process, large membranes suspended 1 micron above a substrate have been elaborated. A membrane with a wide heat exchange area and such a small gap allows the gauge to be sensitive in the high vacuum regime, and ensures a broader pressure range of measurement. By optimizing the membrane and beam sizes, this paper shows that one can combine different membranes to design a packaged sensor with a wide sensitive pressure range (10 -2 to 10 5 Pa) and a very low power consumption (maximum 115 microwatt in this paper). These results allow the design of a fully integrated sensor, based on a unique technology, that can be integrated for in-situ pressure measurements in vacuum applications.