MCMing-Che Chen

Ming-Che Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ming-Che Chen has a total of 46 co-authors. Here are the top co-authors by number of shared publications:

  • Wan-Jung Chang

    Department of Electronic Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan

    7 shared publications
  • Ying-Nien Chou

    Department of Chemical Engineering, National Chung Cheng University, Minhsiung, Chiayi 62102, Taiwan

    3 shared publications
  • Cheng-Yu Lin

    Department of Otolaryngology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Sleep Medicine Center, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan

    2 shared publications
  • Chien-Yan Chien

    Department of Electronic Engineering, Southern Taiwan University of Science and Technology, Tainan, Taiwan

    2 shared publications
  • Ching-Nung Wu

    Department of Otolaryngology Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine Kaohsiung Taiwan

    2 shared publications
  • Chung-Feng Hwang

    Department of Otolaryngology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan

    2 shared publications

Latest Publications

  • Reductive co-deposition of multiple nanomaterials on PU fibers for stretchable strain sensors

    by Lien-Chiang Hung, Po-Chun Huang, Shiau-Wu Lai, Ming-Che Chen, Wan-Jung Chang, Ying-Nien Chou

  • ChainEcho: A Cascaded Audio-Sensing Relay Framework for Indoor IoT Beacon Applications

    by Ming-Che Chen, Wun-Cian Lan, Wan-Jung Chang

    This article proposes a cascaded audio-sensing relay framework, called ChainEcho, which leverages near-ultrasonic, inaudible acoustic signals to support indoor beacon applications (APPs). In response to the interference and scalability limitations commonly observed in large-scale Bluetooth low energy (BLE) deployments, ChainEcho employs 18–20-kHz frequency-shift keying (FSK) modulation and Goertzel-based demodulation to enable low-cost, hardware-free, and noise-resistant data links using commercial-off-the-shelf devices (e.g., smartphones). The system incorporates a compact 3-B frame format, Hamming coding, and a transmission control protocol (TCP)-inspired multihop protocol to maintain stable communication in noisy environments and extend transmission range through acoustic relaying. The experimental results demonstrate reliable reception across various test conditions, confirming that ChainEcho provides a practical alternative for indoor positioning and data-delivery systems that leverage existing devices. Its key contribution lies in leveraging widely available speakers and microphones to build a cost-effective and rapidly deployable indoor acoustic communication architecture.

  • Open Access

    RF-Driven Adaptive Surrogate Models for LoRaDisC Network Performance Prediction in Smart Agriculture and Field Sensing Environments

    by Showkat Ahmad Bhat, Ishfaq Bashir Sofi, Ming-Che Chen, Nen-Fu Huang

    LoRa-based IoT systems are increasingly used in smart farming, greenhouse monitoring, and large-scale agricultural sensing, where long-range, energy-efficient communication is essential. However, estimating link quality metrics such as PRR, RSSI, and SNR typically requires continuous packet transmission and sequence logging, an impractical approach for power-constrained field nodes. This study proposes a deep learning-driven framework for real-time prediction of link- and network-level performance in multihop LoRa networks, targeting the LoRaDisC protocol commonly deployed in agricultural environments. By integrating Bayesian surrogate modeling with Random Forest-guided hyperparameter optimization, the system accurately predicts PRR, RSSI, and SNR using multivariate time series features. Experiments on a large-scale outdoor LoRa testbed (ChirpBox) show that aggregated link layer metrics strongly correlate with PRR, with performance influenced by environmental variables such as humidity, temperature, and field topology. The optimized model achieves a mean absolute error (MAE) of 8.83 and adapts effectively to dynamic environmental conditions. This work enables energy-efficient, autonomous communication in agricultural IoT deployments, supporting reliable field sensing, crop monitoring, livestock tracking, and other smart farming applications that depend on resilient low-power wireless connectivity.


  • Open Access

    A Human-in-the-Loop AI-Assisted Smart-Glasses Verification System for Chemotherapeutic Drug Preparation

    by Ming-Shun Wang, Showkat Ahmad Bhat, Ming-Yi Liao, Min-Yu Lin, Chiu-Lan Yan, Ying-Nien Chou, Ming-Che Chen

  • Open Access

    Wearable Augmented Reality for Nystagmus Examination in Patients With Vertigo: Randomized Crossover Usability Study

    by Ching-Nung Wu, Ming-Che Chen, Chien-Yan Chien, Hsiang-Han Chang, Sheng-Dean Luo, Chung-Feng Hwang, Wan-Jung Chang

    We demonstrate the feasibility of a wearable, augmented reality–based nystagmus examination system, showing its preliminary diagnostic agreement with conventional video-oculography and its potential for portable vestibular assessment in patients with vertigo.


  • GaitMirror: Design and Implementation of an Artificial Intelligence-Based Gait Recognition System for Evaluating the Effectiveness of Lower Limb Rehabilitation

    by Ming-Che Chen, Jian-Ping Su, Yu-Lin Wang, Wan-Jung Chang

    Patients with lower limb instability-related diseases (e.g., stroke) have high fall risks, highlighting the need for effective rehabilitation and objective evaluation methods. Clinicians typically observe gait characteristics (e.g., stride lengths, gait stability, and coordination) using evaluation tools such as the Brunnstrom stages (BSs) to compare pre- and postrehabilitation statuses. However, this strategy heavily relies on clinical expertise and is susceptible to individual biases, posing challenges during objective evaluations. This paper proposes an artificial intelligence (AI)-based gait recognition system called GaitMirror, which is composed of an imaging camera, an edge AI computing device, and a touch screen panel. GaitMirror utilizes deep learning-based human pose estimation to detect keypoints in the captured images. By tracking the coordinate changes exhibited by specific keypoints during walking and applying an innovative subpixel-precision SBR algorithm, it computes multiple walking quantitative metrics (WQMs)—including length of a step (LS), number of steps (NS), walking speed (WS), step time variability (STV), and body sway angle (BSA)—to provide clinicians with objective gait data. Experimental results demonstrate that GaitMirror achieves sub-centimeter accuracy in LS measurement, thereby enhancing the precision of NS, WS, and STV calculations; moreover, its BSA measurements accurately reflect the body’s center-of-gravity shifts in both horizontal and vertical directions. In clinical trials, GaitMirror analyzed the gait characteristics of 20 stroke patients at different BSs, yielding consistent WQMs across patients within the same BS. These findings underscore the potential of GaitMirror to serve as a valuable complementary tool for clinical evaluation purposes.


  • Open Access

    Enhancing Adherence to Continuous Positive Airway Pressure Therapy in Patients With Obstructive Sleep Apnea Using Augmented Reality: Protocol for a Randomized Controlled Trial

    by Ming-Che Chen, Yen-Chin Chen, Cheng-Yu Lin

    Background: Continuous positive airway pressure (CPAP) therapy is the gold standard treatment for treating obstructive sleep apnea (OSA). However, patient adherence to CPAP therapy remains a critical challenge, with many individuals finding it difficult to maintain consistent use due to discomfort, lack of understanding, or perceived inconvenience. Augmented reality (AR) offers a novel approach to overcoming these barriers by providing interactive real-time guidance to users, potentially enhancing adherence rates. Objective: This clinical trial aims to examine the feasibility of AR implementation and the effect of AR on improving CPAP adherence in patients with OSA. Methods: A randomized controlled trial with a parallel assignment will be conducted. Participants will be randomly assigned to either an experimental group receiving AR-guided CPAP therapy or a control group receiving standard care. The study will span 6 months, with assessments at baseline (T0), and with follow-ups at 1 month (T1), 3 months (T2), and 6 months (T3) post intervention. The primary outcome measure is CPAP adherence, defined as using the CPAP device for more than 70% of sleep time, with a minimum of 4 hours per night. Secondary outcomes will evaluate the common adverse effects associated with CPAP therapy, device usability, and time required for CPAP machine use education. Results: This study is funded by the Ministry of Science and Technology, Taiwan (August 2023 to July 2026) and was registered in August 2024 (ClinicalTrials.gov NCT06520592). Participant recruitment is scheduled to begin in April 2025, and by September 2025, we expect to have enrolled 40 participants (50% of the target sample of 80). Preliminary analyses of CPAP adherence at 1 month and usability data are currently underway. Final data collection is anticipated to be completed by December 2025, with results expected to be published by Fall 2026. Conclusions: Anticipated findings suggest that AR-guided CPAP therapy may significantly enhance patient adherence by improving mask fitting and providing effective, interactive education. If validated, this innovative approach could pave the way for more personalized technology-driven interventions in OSA management and other chronic conditions requiring long-term therapy adherence. Trial Registration: ClinicalTrials.gov NCT06520592; https://clinicaltrials.gov/study/NCT06520592 International Registered Report Identifier (IRRID): PRR1-10.2196/69757


  • Open Access

    Wearable Augmented Reality for Nystagmus Examination in Patients With Vertigo: Randomized Crossover Usability Study (Preprint)

    by Ching-Nung Wu, Ming-Che Chen, Chien-Yan Chien, Hsiang-Han Chang, Sheng-Dean Luo, Chung-Feng Hwang, Wan-Jung Chang

    UNSTRUCTURED We demonstrate the feasibility of a wearable, augmented reality–based nystagmus examination system, showing its preliminary diagnostic agreement with conventional video-oculography and its potential for portable vestibular assessment in patients with vertigo.

  • SmartPD: An AI-Enhanced System for Optimizing Home-Based Continuous Ambulatory Peritoneal Dialysis

    by Ming-Che Chen, Ren-Guei Hsu, Hsin-Hsu Chou, Hsiag-Chun Chen, Jin-Yi Lin, Chi-Tze Lin, Neng-Yao You, Ming-Yi Li, Shu-Kai Li, Wei-Ren Zeng, et al.

    In this paper, SmartPD, which is an artificial intelligence of things-based monitoring system designed for continuous ambulatory peritoneal dialysis (CAPD) treatment at home, is proposed. SmartPD comprises a heating and thermal preservation module, an infusion detection and cutoff module, a turbidity identification module, and a display module. It efficiently raises and maintains the temperature of fresh dialysate at 37°C. Additionally, the system monitors infusion volume by detecting changes in the weight of the dialysate bag, automatically shutting off infusion upon reaching a preset threshold to prevent over- or under-infusion. SmartPD also utilizes deep learning technology to identify the turbidity of the drainage fluid from the abdominal cavity, assisting patients in determining whether peritoneal infection symptoms are present. These monitoring data are transmitted and recorded in the proposed cloud-based information management (CIM) platform. The experimental results show that SmartPD can quickly heat 2,000 c.c. of fresh dialysate to 37°C within 30 min, with overall turbidity recognition recall, precision, accuracy and area under the curve (AUC) values exceeding 0.95. Consequently, SmartPD improves the efficiency of CAPD treatment, helps patients assess the severity of associated peritoneal symptoms, and prevents the occurrence of peritonitis. The construction of the CIM platform meets the needs of hospitals for remote patient monitoring, thereby enhancing the quality of CAPD home treatment and reducing costs.