SSStefano Stanzione

Stefano Stanzione

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stefano Stanzione has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Hybrid EOG System Featuring Flexible a-IGZO TFTs and a 180 nm CMOS IC

    by Mohammad Zulqarnain, Stefano Stanzione, Elisabetta Peri, Steve Smout, Myriam Willegems, Pieter Harpe, Kris Myny, Eugenio Cantatore

    Flexible wearable sensors are becoming increasingly popular due to their capability to monitor physiological signals while ensuring high user comfort. Wearable sensors built using only flexible electronics result in inferior system performance due to the inherent limitations of flexible technologies. Flexible hybrid electronics (FHE) combines the strengths of flexible technologies (low cost, larger area coverage, user comfort) with the high performance and energy efficiency of silicon ICs. Here, an FHE system is described that addresses the challenge of system functions partitioning between flexible and silicon (Si) subsystems. The presented design approach is applied in this work to a multichannel electro-oculography (EOG) system, but can be expanded to various FHE application domains. The proof of concept fully-integrated 8-channel FHE EOG system exploits a front-end in a-IGZO TFT technology, interfaced with a custom Si IC that supports the front-end and provides conversion of the acquired signals to the digital domain. In this way the low cost, flexible form factor and the large area character of the flexible thin-film transistor (TFT) technology are leveraged, while exploiting at the same time the accuracy, computational capability and energy efficiency of the Si IC. We propose a hybrid high-pass filter (hHPF) as interface between the electrodes and the front-end, whereby TFTs and capacitors on foil are being controlled by the Si IC. The hybrid approach exploits the capabilities of flexible electronics to bring functionality close to the electrodes and its potential to cope with a high number of sensor channels, with the better precision of CMOS, enabling a fully integrated filter without discrete components. The TFT front-end converts the input signal voltages to a pulse-width modulated (PWM) representation, which is then quantized in the Si IC, to provide a digital output. The Si IC enables conversion to the digital domain with much higher efficiency compared to state-of-the-art TFT solutions. The digital output is further used in an algorithm for feature extraction and classification to detect the desired signals. The experimental electrical characterization of the system demonstrates an input-referred noise of 6.68 μVrms in a 1-30 Hz band, with a chopping frequency of 1 kHz. The input impedance offered by the integrated hHPF is 6.88 GΩ at 0.089 Hz (with multiplexing disabled). The total power consumption per channel is 84 μW. In-vivo experiments have also been performed against a gold standard (a commercial bio-potential amplifier), to confirm a faithful representation of the eye activities. The signals acquired during in-vivo experiments are successfully classified using a support vector machine (SVM) classifier, with an average accuracy of 87.6 ± 2.9%.

  • A Dynamic-Supply Temporal Interference Stimulation ASIC With Accurate Charge Balancing

    by Haoming Xin, Roland van Wegberg, Stefano Stanzione, Vojkan Mihajlović, Carolina Mora Lopez, Mario Konijnenburg, Nick van Helleputte

  • Dynamic Sub-Array Selection-Based Energy-Efficient Localization and Tracking Method to Power Implanted Medical Devices in Scattering Heterogenous Media Employing Ultrasound

    by Anirudh Kumar Parag, Bogdan C. Raducanu, Oguz Kaan Erden, Stefano Stanzione, Fabian Beutel, Chinmay Pendse, Chris Van Hoof, Nick Van Helleputte, Georges Gielen

    Ultrasound (US) as a wireless power transfer methodology has drawn considerable attention from the implantable medical devices (IMD) research community. Beamforming (BF) using an external transducer array patch (ETAP) has been proposed as a robust localization scheme to find a mm-sized IMD inside the human body. However, for applications focusing on deep and shallow IMDs, optimum resource utilization at the ETAP is a major power efficiency concern for energy-constrained wearable patches. Moreover, misalignment tolerance due to IMD movements (respiratory and patient ambulatory reasons) relative to the ETAP remains a challenge. This paper presents an energy-efficient method to localize a mm-sized IMD through the dynamic selection of a sub-array within the ETAP. It is fully adaptive to the heterogeneity of the media and requires no a priori knowledge of the IMD. To improve the tolerance to IMD movements, tracking is implemented by adding and subtracting elements on the sub-array such that the sub-array electrically follows the IMD movement. Furthermore, it is shown that a minimum sampling frequency of 10X the US frequency can improve the tolerance to random noise. K-wave simulations in MATLAB are performed in different heterogenous, scattering biological media to prove the efficacy of the proposed method over standard BF methods. Measurement results in heterogenous scattering media consisting of a 3D-printed human ribs phantom and a partially blocking multipath cancellous bone phantom show an energy efficiency improvement of 10.53X and 14.4X compared to the delay-and-sum beamforming method and the unfocused transmission employing all the elements of the ETAP, respectively.


  • Open Access

    Optimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People

    by Tom Van de Steene, Emmeric Tanghe, Luc Martens, Carmine Garripoli, Stefano Stanzione, Wout Joseph

    This study investigates wireless power transfer for deep in-body receivers, determining the optimal frequency, power budget, and design for the transmitter and receiver. In particular, the focus is on small, in-body receivers at large depths up to 20 cm for obese patients. This enables long-term monitoring of the gastrointestinal tract for all body types. Numerical simulations are used to investigate power transfer and losses as a function of frequency and to find the optimal design at the selected frequency for an obese body model. From all ISM-frequencies in the investigated range (1 kHz–10 GHz), the value of 13.56 MHz yields the best performance. This optimum corresponds to the transition from dominant copper losses in conductors to dominant losses in conductive tissue. At this frequency, a transmitting and receiving coil are designed consisting of 12 and 23 windings, respectively. With a power transfer efficiency of 2.70×10−5, 18 µW can be received for an input power of 0.68 W while still satisfying exposure guidelines. The power transfer is validated by measurements. For the first time, efficiency values and the power budget are reported for WPT through 20 cm of tissue to mm sized receivers. Compared to WPT at higher frequencies, as commonly used for small receivers, the proposed system is more suitable for WPT to large depths in-body and comes with the advantage that no focusing is required, which can accommodate multiple receivers and uncertainty about receiver location more easily. The received power allows long-term sensing in the gastrointestinal tract by, e.g., temperature, pressure, and pH sensors, motility sensing, or even gastric stimulation.


  • An Ultra Low-Power Programmable Voltage Reference for Power-Constrained Electronic Systems

    by Michele Caselli, Evgenii Tiurin, Stefano Stanzione, Andrea Boni

    This paper proposes a novel architecture for the generation of a programmable voltage reference: the background-calibrated (BC)-PVR. Our mixed-signal architecture periodically calibrates a static ultra low-power voltage reference generator, from an accurate bandgap reference. The portion of the chip used for the calibration can be powered down with a programmable duty-cycle. The system aims to fully exploit the small temperature derivative vs time $D_{T}$ of several application domains to minimize the average current consumption. The BC-PVR has been designed and implemented in TSMC 55-nm CMOS technology, and it achieves the largest reported programming reference output range [0.42 - 2.52] V, over the temperature range [−20, 85] °C. The duty-cycle mode allows nanoampere current consumption, and the large design flexibility permits to optimize the system performance for the specific application. These features make the BC-PVR very well-suited for power-constrained electronic systems.


  • Wearable Multiple Modality Bio-Signal Recording and Processing on Chip: A Review

    by Qiuyang Lin, Shuang Song, Ivan D. Castro, Hui Jiang, Mario Konijnenburg, Roland van Wegberg, Dwaipayan Biswas, Stefano Stanzione, Wim Sijbers, Chris Van Hoof, et al.

    Remote home monitoring via wearables is rapidly gaining popularity, thanks to ever more complex vital signs recording and data analytics that are embedded into single devices. True system-on-chips (SoCs) push the envelope of power and form factor, while wearables are becoming more common-place, novel health sensing paradigms appear. Non-contact sensing technologies enable vital signs sensing without requiring any physical contact with the human body. This paper reviews existing multiple-modality bio-signal recording and processing SoCs, circuit techniques for individual bio-signal readout channels including electrocardiography (ECG), Electroencephalography (EEG), Bio-impedance (BioZ), photoplethysmography (PPG), and non-contact sensing with high user comfort. The stateof- the-art wearable sensor interfaces and systems together with future development trends are provided.


  • An Artificial Iris ASIC With High Voltage Liquid Crystal Driver, 10-nA Light Range Detector and 40-nA Blink Detector for LCD Flicker Removal

    by Bogdan C. Raducanu, Samira Zaliasl, Stefano Stanzione, Chris van Liempd, Andres Vasquez Quintero, Herbert De Smet, Johan De Baets, Chris van Hoof, Nick Van Helleputte

    In a normally functioning eye, the iris controls the pupil diameter to regulate the amount of light reaching the retina. Various iris deficiencies exist, manifesting as defects in the iris or an absence of one which result in too much light reaching the retina. Some iris deficiencies such as aniridia or leiomyoma can be mitigated with fixed or adaptive artificial irises 1. As an alternative, adaptive transparency glasses may also alleviate this situation, however both solutions do not mimic the other normal functionality of the natural iris: adaptive aperture. To address this, we developed a fully encapsulated, self-contained artificial iris embedded in a smart contact lens. The control ASIC of the contact lens is developed in 0.18 μm 16 V BCD TSMC and has a typical power consumption of 1.9 μW from a 3 V supply voltage at office light condition.


  • Open Access

    A Switched-Capacitor DC-DC Converter Powering an LC Oscillator to Achieve 85% System Peak Power Efficiency and −65dBc Spurious Tones

    by Alessandro Urso, Yue Chen, Robert Bogdan Staszewski, Johan F. Dijkhuis, Stefano Stanzione, Yao-Hong Liu, Wouter A. Serdijn, Masoud Babaie

    In this paper, we propose a new scheme to directly power a 4.9-5.6GHz LC oscillator from a recursive switched-capacitor DC-DC converter. A finite-state machine is integrated to automatically adjust the conversion ratio and switching frequency of the converter such that its DC output voltage is within ±5% of the desired 1V across input voltage range 1.3-2.2V and <2mA load current conditions. A gate-driver circuit is embedded in each switch of the converter to guarantee constant on-resistance across PVT variations without sacrificing device reliability. Furthermore, a spur reduction block (SRB) is embedded in the oscillator to suppress the ripple induced spurs by stabilizing its tail current. Both the converter and the oscillator are implemented in 40-nm CMOS technology. The measured peak power efficiency of the converter is 87%, while its spot noise is <1.5nV/√ Hz, which does not degrade the phase noise of the oscillator. The SRB suppresses the spur to <-65,dBc under the 30mV pp ripple of the converter.


  • Miniaturized Electronic Circuit Design Challenges for Ingestible Devices

    by Nick Van Helleputte, Aniek J. G. Even, Francesca Leonardi, Stefano Stanzione, Minyoung Song, Carmine Garripoli, Wim Sijbers, Yao-Hong Liu, Chris Van Hoof

    The gastro-intestinal (GI) tract is a very important part of the human digestive system but remains largely inaccessible for unobtrusive monitoring. Ingestible electronic devices are a very interesting concept to address this need. This paper discusses the current state of ingestible electronic devices and explores the potential they hold to provide unprecedented insight by measuring several aspects of the complex bio-chemical processes that happen in the GI tract in real-time. This will require novel sensor technology capable of measuring relevant markers with adequate specificity and accuracy. In order to be able to scale this functionality down to a form factor of an easily digestible pill, ultra-low-power wireless interface electronics are needed. This poses certain challenges and innovation opportunities related to sensing, wireless communication and powering to enable the next generation of ingestible electronic devices. [2020-0164]