Aristeidis A. Bloutsos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aristeidis A. Bloutsos has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Panayotis C. Yannopoulos
Environmental Engineering Laboratory, Department of Civil Engineering, University of Patras, Patras, Greece
7 shared publications - Anastasios I. Stamou
Laboratory of Applied Hydraulics, Department of Water Resources and Environmental Engineering, National Technical University of Athens, 15780 Athens, Greece
3 shared publications - Aristeidis Koutroulis
Technical University of Crete, School of Chemical and Environmental Engineering, Chania, Greece
2 shared publications - Athanasia Tatiana Stamou
Laboratory of Applied Hydraulics, Department of Water Resources and Environmental Engineering, National Technical University of Athens, 15780 Athens, Greece
2 shared publications - Athanasios Sfetsos
Environmental Research Laboratory, National Centre for Scientific Research “Democritus”, Athens, Greece
2 shared publications - Christos Giannakopoulos
Institute for Environmental Research and Sustainable Development, National Observatory of Athens, Lofos Koufou, 15236 Palaia Penteli, Athens, Greece
2 shared publications
Latest Publications
- Open Access
Risk Assessment of Dams and Reservoirs to Climate Change in the Mediterranean Region: The Case of Almopeos Dam in Northern Greece
Climate change poses significant challenges to the operation and safety of dam and reservoir (D&R) systems, particularly in regions characterized by water scarcity and high climate variability. This study presents a structured methodology for climate risk assessment that integrates regional climate projections, system-specific thresholds, and a semi-quantitative risk matrix approach. A key innovation is the explicit linkage between climate indicators and system performance through physically based thresholds, combined with empirically derived exceedance probabilities from high-resolution climate projections. The methodology is applied to the Almopeos D&R system in northern Greece, using an ensemble of statistically downscaled CMIP6 simulations under two emission scenarios (SSP2-4.5 and SSP5-8.5) and two future periods (2041–2060 and 2081–2100). Three climate indicators are analyzed: TX35 (temperature extremes), CDD (consecutive dry days), and Rx1day (extreme precipitation). Results indicate that temperature increase is the dominant climate risk hazard, leading to increased irrigation demand and reduced system reliability, with risks classified as high to very high. Drought conditions represent a secondary but important risk, becoming critical during prolonged dry periods affecting reservoir storage, while extreme precipitation events exhibit low likelihood but potentially high consequences for dam safety. Adaptation measures are prioritized using a qualitative multi-criteria approach, highlighting the effectiveness of operational measures, while structural and monitoring interventions remain essential for ensuring system safety. The proposed methodology provides a transparent and transferable framework for climate-resilient planning of water infrastructure systems.
Open AccessRisk Assessment of Dams and Reservoirs to Climate Change in the Mediterranean Region: The Case of Almopeos Dam in Northern Greece
Climate change poses significant challenges to the operation and safety of dam and reservoir (D&R) systems, particularly in regions characterized by water scarcity and high climate variability. This study presents a structured methodology for climate risk assessment that integrates regional climate projections, system-specific thresholds, and a semi-quantitative risk matrix approach. A key innovation is the explicit linkage between climate indicators and system performance through physically based thresholds, combined with empirically derived exceedance probabilities from high-resolution climate projections. The methodology is applied to the Almopeos D&R system in northern Greece, using an ensemble of statistically downscaled CMIP6 simulations under two emission scenarios (SSP2-4.5 and SSP5-8.5) and two future periods (2041–2060 and 2081–2100). Three climate indicators are analyzed: TX35 (temperature extremes), CDD (consecutive dry days), and Rx1day (extreme precipitation). Results indicate that temperature increase is the dominant climate risk hazard, leading to increased irrigation demand and reduced system reliability, with risks classified as high to very high. Drought conditions represent a secondary but important risk, becoming critical during prolonged dry periods affecting reservoir storage, while extreme precipitation events exhibit low likelihood but potentially high consequences for dam safety. Adaptation measures are prioritized using a qualitative multi-criteria approach, highlighting the effectiveness of operational measures, while structural and monitoring interventions remain essential for ensuring system safety. The proposed methodology provides a transparent and transferable framework for climate-resilient planning of water infrastructure systems.
- Open Access
- 3 April 2026
- Published by MDPI AG in Preprints.org
Risk Assessment of Dams and Reservoirs to Climate Change in the Mediterranean Region: The Case of Almopeos Dam in Northern Greece
Climate change poses significant challenges to the operation and safety of dam and reservoir (D&R) systems, particularly in regions characterized by water scarcity and high climate variability. This study presents a structured methodology for climate risk assessment that integrates regional climate projections, system-specific thresholds, and a semi-quantitative risk matrix approach. A key innovation is the explicit linkage between climate indicators and system performance through physically based thresholds, combined with empirically derived exceedance probabilities from high-resolution climate projections. The methodology is applied to the Almopeos D&R system in Northern Greece using an ensemble of statistically downscaled CMIP6 simulations under two emission scenarios (SSP2-4.5 and SSP5-8.5) and two future periods (2041–2060 and 2081–2100). Three climate indicators are analyzed: TX35 (temperature extremes), CDD (consecutive dry days), and Rx1day (extreme precipitation). Results indicate that temperature increase is the dominant climate risk hazard, leading to increased irrigation demand and reduced system reliability, with risks classified as high to very high. Drought conditions represent a secondary but important risk, becoming critical during prolonged dry periods affecting reservoir storage, while extreme precipitation events exhibit low likelihood but potentially high consequences for dam safety. Adaptation measures are prioritized using a qualitative multi-criteria approach, highlighting the effectiveness of operational measures, while structural and monitoring interventions remain essential for ensuring system safety. The proposed methodology provides a transparent and transferable framework for climate-resilient planning of water infrastructure systems.
- 3 April 2026
- Published by MDPI AG in Preprints.org
Open AccessRisk Assessment of Dams and Reservoirs to Climate Change in the Mediterranean Region: The Case of Almopeos Dam in Northern Greece
Climate change poses significant challenges to the operation and safety of dam and reservoir (D&R) systems, particularly in regions characterized by water scarcity and high climate variability. This study presents a structured methodology for climate risk assessment that integrates regional climate projections, system-specific thresholds, and a semi-quantitative risk matrix approach. A key innovation is the explicit linkage between climate indicators and system performance through physically based thresholds, combined with empirically derived exceedance probabilities from high-resolution climate projections. The methodology is applied to the Almopeos D&R system in Northern Greece using an ensemble of statistically downscaled CMIP6 simulations under two emission scenarios (SSP2-4.5 and SSP5-8.5) and two future periods (2041–2060 and 2081–2100). Three climate indicators are analyzed: TX35 (temperature extremes), CDD (consecutive dry days), and Rx1day (extreme precipitation). Results indicate that temperature increase is the dominant climate risk hazard, leading to increased irrigation demand and reduced system reliability, with risks classified as high to very high. Drought conditions represent a secondary but important risk, becoming critical during prolonged dry periods affecting reservoir storage, while extreme precipitation events exhibit low likelihood but potentially high consequences for dam safety. Adaptation measures are prioritized using a qualitative multi-criteria approach, highlighting the effectiveness of operational measures, while structural and monitoring interventions remain essential for ensuring system safety. The proposed methodology provides a transparent and transferable framework for climate-resilient planning of water infrastructure systems.
- Open Access
- 13 June 2025
- Published by Springer Nature in Environmental Fluid Mechanics
- Vol. 25 (3) , 1-34
Large Eddy simulation of annular plumes
Annular plumes discharged in stable and uniform environments of greater density than the initial plume density were simulated to detect and explain possible existing differences compared to available experimental data. Two cases were simulated numerically with exit velocities of 0.527 and 0.702 m/s; exit/ambient temperatures of 68.5/23 °C; outer/inner annular source diameters of 0.13/0.11 m; equivalent densimetric Froude numbers of 1.63 and 2.12 and Reynolds numbers of 2380 and 3171. These cases have recently been investigated experimentally (Stefanidou et al. in Environ Fluid Mech 23:965–1010, 2023, https://doi.org/10.1007/s10652-023-09943-z). For quasi-steady-state conditions, the annular plume is simulated by employing the Reynolds-averaged Navier–Stokes equations via the k–ε-realizable turbulence model and the large-eddy simulation (LES) via the wall-adapting local eddy viscosity (WALE) subgrid stress turbulence model of ANSYS© Fluent software. The results regarding the centreline mean velocity and mean relative concentration were compared with the above experimental measurements, with an exit velocity of 0.527 m/s, and proved that LES-WALE is better at predicting the annular plumes. Thus, the latter was used to simulate both above cases. In general, the predictions agree well with the measurements regarding the mean flow and mixing characteristics in the core region and the region beyond the core. The results for the turbulent intensities of velocities and temperature were also obtained for both the core and beyond the core regions. The transverse profiles of the mean axial velocity and mean relative concentration were used to determine the corresponding spreading coefficients, which were in good agreement with literature experimental data regarding equivalent round plumes.
- 13 June 2025
- Published by Springer Nature in Environmental Fluid Mechanics
- Vol. 25 (3) , 1-34
Open AccessLarge Eddy simulation of annular plumes
Annular plumes discharged in stable and uniform environments of greater density than the initial plume density were simulated to detect and explain possible existing differences compared to available experimental data. Two cases were simulated numerically with exit velocities of 0.527 and 0.702 m/s; exit/ambient temperatures of 68.5/23 °C; outer/inner annular source diameters of 0.13/0.11 m; equivalent densimetric Froude numbers of 1.63 and 2.12 and Reynolds numbers of 2380 and 3171. These cases have recently been investigated experimentally (Stefanidou et al. in Environ Fluid Mech 23:965–1010, 2023, https://doi.org/10.1007/s10652-023-09943-z). For quasi-steady-state conditions, the annular plume is simulated by employing the Reynolds-averaged Navier–Stokes equations via the k–ε-realizable turbulence model and the large-eddy simulation (LES) via the wall-adapting local eddy viscosity (WALE) subgrid stress turbulence model of ANSYS© Fluent software. The results regarding the centreline mean velocity and mean relative concentration were compared with the above experimental measurements, with an exit velocity of 0.527 m/s, and proved that LES-WALE is better at predicting the annular plumes. Thus, the latter was used to simulate both above cases. In general, the predictions agree well with the measurements regarding the mean flow and mixing characteristics in the core region and the region beyond the core. The results for the turbulent intensities of velocities and temperature were also obtained for both the core and beyond the core regions. The transverse profiles of the mean axial velocity and mean relative concentration were used to determine the corresponding spreading coefficients, which were in good agreement with literature experimental data regarding equivalent round plumes.
- 15 March 2024
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 235 (3) , 1-34
Seasonal and Long-Term Water Quality of Alfeios River Basin in Greece
- 15 March 2024
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 235 (3) , 1-34
Seasonal and Long-Term Water Quality of Alfeios River Basin in Greece
- Open Access
- 23 August 2023
- Published by MDPI AG in Environmental Sciences Proceedings
- Vol. 26 (1) , 19
Temporal Variation of PM1 on the Campus of the University of Patras, Greece
Several scientific studies reveal that particulate matter that is smaller than 1 μm (PM1) represents the main hazard for the cardiorespiratory pathological status of the population. The present study deals with the presentation of the long-term continuous measurements of PM1 in the atmospheric environment of the University of Patras Campus (UPC) at Rion. The 1 h mean concentrations of PM1 were recorded and presented in this study, covering a seven-year period (2012–2018) in a suburban area of Patras, with background characteristics. The results indicated that PM1 levels were quite low, with significant differences between cold and warm periods. However, they did not show significant variations. This project aimed to identify and assess UPC air quality. Our findings may contribute to useful PM1 concentration patterns based on the long-term recorded data.
- 23 August 2023
- Published by MDPI AG in Environmental Sciences Proceedings
- Vol. 26 (1) , 19
Open AccessTemporal Variation of PM1 on the Campus of the University of Patras, Greece
Several scientific studies reveal that particulate matter that is smaller than 1 μm (PM1) represents the main hazard for the cardiorespiratory pathological status of the population. The present study deals with the presentation of the long-term continuous measurements of PM1 in the atmospheric environment of the University of Patras Campus (UPC) at Rion. The 1 h mean concentrations of PM1 were recorded and presented in this study, covering a seven-year period (2012–2018) in a suburban area of Patras, with background characteristics. The results indicated that PM1 levels were quite low, with significant differences between cold and warm periods. However, they did not show significant variations. This project aimed to identify and assess UPC air quality. Our findings may contribute to useful PM1 concentration patterns based on the long-term recorded data.
- Open Access
- 23 August 2023
- Published by MDPI AG in Environmental Sciences Proceedings
- Vol. 26 (1) , 6
Seawater Quality Measurements at the Two Ports of Patras, Greece
A monitoring program of seawater quality was conducted during the October 2013–June 2016 period at the port city of Patras. A total of fourteen sampling campaigns were conducted. Eleven sampling sites were selected at the Southern New Port and at the Northern Old Port of Patras, namely at the discharge point of the south outlet of the collecting storm water conduit and at the two river mouths discharging at both sides of the Southern New Port, to evaluate the contribution of surface runoff and harbor activities on seawater pollution. At each site, water quality parameters were determined in situ, and water samples were transferred and analyzed at the laboratory. Taking into consideration the whole set of measurements, it can be concluded that the seawater quality of the two ports is satisfactory in comparison to other coastal zones in the area around Patras and other ports.
- 23 August 2023
- Published by MDPI AG in Environmental Sciences Proceedings
- Vol. 26 (1) , 6
Open AccessSeawater Quality Measurements at the Two Ports of Patras, Greece
A monitoring program of seawater quality was conducted during the October 2013–June 2016 period at the port city of Patras. A total of fourteen sampling campaigns were conducted. Eleven sampling sites were selected at the Southern New Port and at the Northern Old Port of Patras, namely at the discharge point of the south outlet of the collecting storm water conduit and at the two river mouths discharging at both sides of the Southern New Port, to evaluate the contribution of surface runoff and harbor activities on seawater pollution. At each site, water quality parameters were determined in situ, and water samples were transferred and analyzed at the laboratory. Taking into consideration the whole set of measurements, it can be concluded that the seawater quality of the two ports is satisfactory in comparison to other coastal zones in the area around Patras and other ports.
- Open Access
- 1 August 2023
- Published by Springer Nature in Environmental Fluid Mechanics
- Vol. 23 (4) , 965-1010
Experimental investigation and integral simulation of a thermal annular plume
Thermal plumes issued with mean exit velocities of 0.527 and 0.702 m/s from internally closed annular nozzles are investigated experimentally, theoretically, and numerically. The experimental setup and the measurement and analysis methodologies for flow and mixing are described in detail. The experimental setup consists of an air heating box with an annular slot of 0.12-m mean diameter and 0.01-m width, accompanied by equipment for setup operation and measurement of mean velocities and temperatures. The trajectory of maximum velocities and the isovelocity contours indicate reattachment due to plume self-merging at $$z_{\textrm{P0}}= 0.161$$ m and around 0.20 m in correspondence to exit velocities. It was found that $$z_{\textrm{P0}}$$ depends mainly upon initial Froude number and annulus equivalent diameter. Experiments detected a vortex ring right after the exit followed by a stagnation point at $$z_{\textrm{P1}}\cong 0.055$$ m on the plume centreline. The annular plume core obtains almost uniform temperature and on average 15 times higher dilutions than bulk dilutions of the equivalnt round plume. To predict the self-merging trajectory, a novel integral model was developed named self-merging approach (SMA). SMA is based on the solution of the ordinary differential equations of momentum and buoyancy applied to an infinitesimal sector of the annular plume, which is equivalent to two identical slot plumes. These plumes are reattached due to outer entrainment, inner entrainment starvation, and a series of sinks along the annular plume centreline with strengths calculated by an original relationship. SMA predictions agree very well with the observations. The present findings contribute to a better understanding of the phenomenon and offer new ideas for designing buoyancy-operating disposal systems with low momentum, using annular- or rosette-type diffusers mainly in shallow water bodies.- 1 August 2023
- Published by Springer Nature in Environmental Fluid Mechanics
- Vol. 23 (4) , 965-1010
Open AccessExperimental investigation and integral simulation of a thermal annular plume
Thermal plumes issued with mean exit velocities of 0.527 and 0.702 m/s from internally closed annular nozzles are investigated experimentally, theoretically, and numerically. The experimental setup and the measurement and analysis methodologies for flow and mixing are described in detail. The experimental setup consists of an air heating box with an annular slot of 0.12-m mean diameter and 0.01-m width, accompanied by equipment for setup operation and measurement of mean velocities and temperatures. The trajectory of maximum velocities and the isovelocity contours indicate reattachment due to plume self-merging at $$z_{\textrm{P0}}= 0.161$$ m and around 0.20 m in correspondence to exit velocities. It was found that $$z_{\textrm{P0}}$$ depends mainly upon initial Froude number and annulus equivalent diameter. Experiments detected a vortex ring right after the exit followed by a stagnation point at $$z_{\textrm{P1}}\cong 0.055$$ m on the plume centreline. The annular plume core obtains almost uniform temperature and on average 15 times higher dilutions than bulk dilutions of the equivalnt round plume. To predict the self-merging trajectory, a novel integral model was developed named self-merging approach (SMA). SMA is based on the solution of the ordinary differential equations of momentum and buoyancy applied to an infinitesimal sector of the annular plume, which is equivalent to two identical slot plumes. These plumes are reattached due to outer entrainment, inner entrainment starvation, and a series of sinks along the annular plume centreline with strengths calculated by an original relationship. SMA predictions agree very well with the observations. The present findings contribute to a better understanding of the phenomenon and offer new ideas for designing buoyancy-operating disposal systems with low momentum, using annular- or rosette-type diffusers mainly in shallow water bodies. - 10 October 2022
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 42 (2)
NOx and CO levels in the Mediterranean major Patras area, Greece
Gaseous pollutants negatively affect air quality and consequently human health and wellbeing. Thus, the University of Patras Campus (UPC) air quality is evaluated in comparison to Patras downtown air quality, regarding nitrogen oxides (NOx) and carbon monoxide (CO) concentration levels. The air pollution station installed at the suburban area of UPC was monitoring the air quality during the period 2014–2018. The daily average concentrations ± standard deviations recorded by continuous measurements of NO, NO2, NOx, and CO were 0.4 ± 0.5, 4.6 ± 2.7, and 5.0 ± 3.0, and 39.3 ± 64.1 μg m−3, correspondingly. These values are lower than the corresponding ones measured by downtown monitoring stations during 2001–2018. After analyzing the data recorded, the diurnal, weakly and yearly variations of NO, NO2, NOx, CO concentrations and NO/NOx, NO2/NOx, NO/NO2 ratios were obtained. The yearly variations show that the pollutant concentrations at UPC are below the legislation limits. On the contrary, in Patras Downtown only NOx concentrations overcome the limit, while NO2 concentrations found marginally below the limit during the last decade. Statistical analysis showed that concentration levels are affected by seasonality and meteorological parameters. The present findings may be useful in environmental impact assessments necessary for sustainable development projects.
- 10 October 2022
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 42 (2)
NOx and CO levels in the Mediterranean major Patras area, Greece
Gaseous pollutants negatively affect air quality and consequently human health and wellbeing. Thus, the University of Patras Campus (UPC) air quality is evaluated in comparison to Patras downtown air quality, regarding nitrogen oxides (NOx) and carbon monoxide (CO) concentration levels. The air pollution station installed at the suburban area of UPC was monitoring the air quality during the period 2014–2018. The daily average concentrations ± standard deviations recorded by continuous measurements of NO, NO2, NOx, and CO were 0.4 ± 0.5, 4.6 ± 2.7, and 5.0 ± 3.0, and 39.3 ± 64.1 μg m−3, correspondingly. These values are lower than the corresponding ones measured by downtown monitoring stations during 2001–2018. After analyzing the data recorded, the diurnal, weakly and yearly variations of NO, NO2, NOx, CO concentrations and NO/NOx, NO2/NOx, NO/NO2 ratios were obtained. The yearly variations show that the pollutant concentrations at UPC are below the legislation limits. On the contrary, in Patras Downtown only NOx concentrations overcome the limit, while NO2 concentrations found marginally below the limit during the last decade. Statistical analysis showed that concentration levels are affected by seasonality and meteorological parameters. The present findings may be useful in environmental impact assessments necessary for sustainable development projects.
- 9 May 2022
- Published by Springer Nature in Environmental Processes
- Vol. 9 (2) , 1-20
Mean Flow and Mixing Properties of a Vertical Round Turbulent Buoyant Jet in a Weak Crosscurrent
- 9 May 2022
- Published by Springer Nature in Environmental Processes
- Vol. 9 (2) , 1-20
Mean Flow and Mixing Properties of a Vertical Round Turbulent Buoyant Jet in a Weak Crosscurrent
- Open Access
Room Air-Conditioning Operating as a Filling Box
The air temperature variation of a closed room, well insulated, during the initial time of operation of air-conditioning systems up to temperature stabilization, is simulated by a two-dimensional integral model as a quasi-steady-state phenomenon. The model equipped with a conservation equation for tracer concentration or relative temperature, including the stratification parameter, is well qualified. The flow leaving the air conditioning device forms an inclined buoyant jet which bends over and meets the room floor, where it spreads sideways forming a layer with jet temperature. A sequence of layers, which affect the jet temperature through entrainment, are produced by a novel bottom-up technique. The layer air temperatures are calculated through the bulk dilution of a near bottom jet cross-section, which feeds each new layer. The model simulated a real case and predicted the transient variation of room air and buoyant jet temperatures up to stabilisation. It also predicted the time needed for stabilisation, the cooling rates of the room and jet air temperatures, the Brunt-Väisälä frequency occurring during the temperature transitions, and more. The results are promising as they agree with observations. Thus, the model could be used to evaluate the effectiveness of relevant HVAC systems operating in such rooms.
Open AccessRoom Air-Conditioning Operating as a Filling Box
The air temperature variation of a closed room, well insulated, during the initial time of operation of air-conditioning systems up to temperature stabilization, is simulated by a two-dimensional integral model as a quasi-steady-state phenomenon. The model equipped with a conservation equation for tracer concentration or relative temperature, including the stratification parameter, is well qualified. The flow leaving the air conditioning device forms an inclined buoyant jet which bends over and meets the room floor, where it spreads sideways forming a layer with jet temperature. A sequence of layers, which affect the jet temperature through entrainment, are produced by a novel bottom-up technique. The layer air temperatures are calculated through the bulk dilution of a near bottom jet cross-section, which feeds each new layer. The model simulated a real case and predicted the transient variation of room air and buoyant jet temperatures up to stabilisation. It also predicted the time needed for stabilisation, the cooling rates of the room and jet air temperatures, the Brunt-Väisälä frequency occurring during the temperature transitions, and more. The results are promising as they agree with observations. Thus, the model could be used to evaluate the effectiveness of relevant HVAC systems operating in such rooms.