Tian Le
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tian Le has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Yinghua Zhang
State Key Laboratory of High‐Efficient Mining and Safety of Metal Mines University of Science and Technology Beijing, Ministry of Education Beijing China
4 shared publications - Zhian Huang
State Key Laboratory of Metal Mine Mining Safety and Disaster Prevention and Control University of Science and Technology Beijing Beijing China
4 shared publications - Yukun Gao
Ministry of Education, State Key Laboratory of High-Efficient Mining and Safety of Metal Mines (University of Science and Technology Beijing), Beijing, China
3 shared publications - Hailiang Wang
Emergency Research Institute of Xinxing Cathay International Group, Beijing 100071, China
2 shared publications Jinyang Li
State Key Laboratory of High‐Efficient Mining and Safety of Metal Mines (University of Science and Technology Beijing), Ministry of Education Beijing China
2 shared publications- Wei Zhao
State Key Laboratory of High‐Efficient Mining and Safety of Metal Mines University of Science and Technology Beijing, Ministry of Education Beijing China
2 shared publications
Latest Publications
- Open Access
- 11 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 147776-147789
Comprehensive Safety Evaluation of Emergency Training for Building Ruins Scenario Based on Analytic Hierarchy Process-Grey Fuzzy Evaluation
The quality of emergency training determines the professional ability of emergency personnel. To evaluate the safety of emergency training for building collapse ruin training scenarios, an approach combining analytic hierarchy process (AHP) and gray-fuzzy evaluation is proposed. According to the characteristics of building collapse ruin training scenarios and the principle of index selection, a safety evaluation index system for this training is constructed from four aspects: human, machine, environment, and management. AHP is used to determine the weight of each evaluation index, and the evaluation model is established base of the gray-fuzzy evaluation method. Based on the combination of the two methods, the quantitative results on training safety was obtained and the most important factor that have the greatest impact on training safety was found. Using this presented assessment method, the safety of an building collapse ruin training scenario for a domestic emergency training facility are assessed, the defects in its emergency capacity are determined, and measures and suggestions are recommended to provide scientific and effective basis for improving emergency capacity.
- 11 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 147776-147789
Open AccessComprehensive Safety Evaluation of Emergency Training for Building Ruins Scenario Based on Analytic Hierarchy Process-Grey Fuzzy Evaluation
The quality of emergency training determines the professional ability of emergency personnel. To evaluate the safety of emergency training for building collapse ruin training scenarios, an approach combining analytic hierarchy process (AHP) and gray-fuzzy evaluation is proposed. According to the characteristics of building collapse ruin training scenarios and the principle of index selection, a safety evaluation index system for this training is constructed from four aspects: human, machine, environment, and management. AHP is used to determine the weight of each evaluation index, and the evaluation model is established base of the gray-fuzzy evaluation method. Based on the combination of the two methods, the quantitative results on training safety was obtained and the most important factor that have the greatest impact on training safety was found. Using this presented assessment method, the safety of an building collapse ruin training scenario for a domestic emergency training facility are assessed, the defects in its emergency capacity are determined, and measures and suggestions are recommended to provide scientific and effective basis for improving emergency capacity.
- 8 August 2020
- Published by Wiley in Fire and Materials
- Vol. 44 (7) , 953-965
A novel high polymer nanocomposite inhibitor for coal gangue spontaneous combustion prevention: A case study of Yangquan coal gangue in China
Summary: Coal gangue spontaneous combustion produces toxic and harmful gases. This research aims to study a new type of polymer nanocomposite inhibitor to prevent and control coal gangue spontaneous combustion. Nanomodification of montmorillonite (MMT) was carried out on high polymer emulsion inhibitor polyacrylamide (PAM) to improve its thermal stability and overcome the short inhibition duration problem. First, through scanning electron microscope (SEM), energy‐dispersive spectrometer (EDS), and proximate analysis experiments, it was found that the coal gangue in the Yangquan mining area was prone to spontaneous combustion. Then, PAM/MMT was produced by an intercalation method. The results of X‐ray diffraction (XRD) and differential scanning calorimetry (DSC) showed that the interval spacing of MMT increased, which was sufficient for the insertion of acrylamide monomer. The vitrification temperatures of PAM and PAM/MMT prove that PAM/MMT exhibited higher thermal stability. The results of Fourier transform infrared spectroscopy (FTIR) experiments indicated that the PAM/MMT composite inhibitor agent effectively inhibited the oxidative activity of reactive groups on the coal gangue surface. As a result, PAM/MMT could suppress coal gangue oxidative spontaneous combustion, so as to reduce environmental problems caused by coal gangue spontaneous combustion. Furthermore, a spraying process is designed for the application of the inhibitor.
- 8 August 2020
- Published by Wiley in Fire and Materials
- Vol. 44 (7) , 953-965
A novel high polymer nanocomposite inhibitor for coal gangue spontaneous combustion prevention: A case study of Yangquan coal gangue in China
Summary: Coal gangue spontaneous combustion produces toxic and harmful gases. This research aims to study a new type of polymer nanocomposite inhibitor to prevent and control coal gangue spontaneous combustion. Nanomodification of montmorillonite (MMT) was carried out on high polymer emulsion inhibitor polyacrylamide (PAM) to improve its thermal stability and overcome the short inhibition duration problem. First, through scanning electron microscope (SEM), energy‐dispersive spectrometer (EDS), and proximate analysis experiments, it was found that the coal gangue in the Yangquan mining area was prone to spontaneous combustion. Then, PAM/MMT was produced by an intercalation method. The results of X‐ray diffraction (XRD) and differential scanning calorimetry (DSC) showed that the interval spacing of MMT increased, which was sufficient for the insertion of acrylamide monomer. The vitrification temperatures of PAM and PAM/MMT prove that PAM/MMT exhibited higher thermal stability. The results of Fourier transform infrared spectroscopy (FTIR) experiments indicated that the PAM/MMT composite inhibitor agent effectively inhibited the oxidative activity of reactive groups on the coal gangue surface. As a result, PAM/MMT could suppress coal gangue oxidative spontaneous combustion, so as to reduce environmental problems caused by coal gangue spontaneous combustion. Furthermore, a spraying process is designed for the application of the inhibitor.
- Open Access
- 3 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 144767-144777
Safety Assessment of Emergency Training for Industrial Accident Scenarios Based on Analytic Hierarchy Process and Gray-Fuzzy Comprehensive Assessment
To evaluate the safety of emergency training for industrial accident scenarios, an approach combining analytic hierarchy process (AHP) and gray-fuzzy evaluation is proposed. According to the characteristics of industrial emergency training scenarios, a safety evaluation index system for this training is constructed from four aspects: human, machine, environment, and management. The index weight is established using the AHP and the evaluation model is established base of the gray-fuzzy evaluation method. Based on the combination of the two methods, the quantitative results on training safety was obtained and the most important factor that have the greatest impact on training safety was found. Using this new assessment method, the safety of an industrial accident training scenario for a domestic emergency training facility are assessed, the defects in its emergency capacity are determined, and measures and suggestions are recommended to provide scientific and effective basis for improving emergency capacity.
- 3 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 144767-144777
Open AccessSafety Assessment of Emergency Training for Industrial Accident Scenarios Based on Analytic Hierarchy Process and Gray-Fuzzy Comprehensive Assessment
To evaluate the safety of emergency training for industrial accident scenarios, an approach combining analytic hierarchy process (AHP) and gray-fuzzy evaluation is proposed. According to the characteristics of industrial emergency training scenarios, a safety evaluation index system for this training is constructed from four aspects: human, machine, environment, and management. The index weight is established using the AHP and the evaluation model is established base of the gray-fuzzy evaluation method. Based on the combination of the two methods, the quantitative results on training safety was obtained and the most important factor that have the greatest impact on training safety was found. Using this new assessment method, the safety of an industrial accident training scenario for a domestic emergency training facility are assessed, the defects in its emergency capacity are determined, and measures and suggestions are recommended to provide scientific and effective basis for improving emergency capacity.
- 8 November 2019
- Published by Wiley in Fire and Materials
- Vol. 44 (1) , 76-89
Development and performance study of a novel physicochemical composite inhibitor for the prevention of coal gangue spontaneous combustion
Summary: To overcome the short inhibition life of currently available inhibitors, a high polymer nanocomposite inhibitor was developed. The spontaneous combustion characteristics of coal gangue from the Yangquan mining area were studied through proximate analysis, scanning electron microscope/energy dispersive spectrometer (SEM/EDS), and thermogravimetric analysis. As a result, the coal gangue was found to be prone to spontaneous combustion. Temperature‐programmed oxidation experiments showed that the average inhibition rates of Ca (OH)2 or polyacrylamide (PAM) were 30.99% and 30.95%, respectively. During testing, when the temperature of the coal gangue exceeded 160°C, the CO production and oxygen consumption rate of the sample with PAM increased dramatically, proving that the PAM inhibition effect was short‐lived with elevating temperature, whereas the inhibition rate of polyacrylamide/montmorillonite (PAM/MMT) was significantly increased to 47.70%. In addition, the CO production and oxygen consumption rates were significantly reduced in the late oxidation period, proving that the addition of MMT was able to effectively improve the high‐temperature resistance of the PAM. Different concentrations of PAM/MMT were compounded with Ca (OH)2, further improving the inhibition effect of the treatment. The inhibition effect of the PAM/MMT 3%‐Ca (OH)2 20% composite inhibitor was the best in the study, with an inhibition rate of 83.15%.
- 8 November 2019
- Published by Wiley in Fire and Materials
- Vol. 44 (1) , 76-89
Development and performance study of a novel physicochemical composite inhibitor for the prevention of coal gangue spontaneous combustion
Summary: To overcome the short inhibition life of currently available inhibitors, a high polymer nanocomposite inhibitor was developed. The spontaneous combustion characteristics of coal gangue from the Yangquan mining area were studied through proximate analysis, scanning electron microscope/energy dispersive spectrometer (SEM/EDS), and thermogravimetric analysis. As a result, the coal gangue was found to be prone to spontaneous combustion. Temperature‐programmed oxidation experiments showed that the average inhibition rates of Ca (OH)2 or polyacrylamide (PAM) were 30.99% and 30.95%, respectively. During testing, when the temperature of the coal gangue exceeded 160°C, the CO production and oxygen consumption rate of the sample with PAM increased dramatically, proving that the PAM inhibition effect was short‐lived with elevating temperature, whereas the inhibition rate of polyacrylamide/montmorillonite (PAM/MMT) was significantly increased to 47.70%. In addition, the CO production and oxygen consumption rates were significantly reduced in the late oxidation period, proving that the addition of MMT was able to effectively improve the high‐temperature resistance of the PAM. Different concentrations of PAM/MMT were compounded with Ca (OH)2, further improving the inhibition effect of the treatment. The inhibition effect of the PAM/MMT 3%‐Ca (OH)2 20% composite inhibitor was the best in the study, with an inhibition rate of 83.15%.