Fabiola Ormiga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fabiola Ormiga has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- José Antônio da Cunha Ponciano Gomes
Federal University of Rio de Janeiro
5 shared publications C. C. F. Amaral
Department of Metallurgy and Materials Federal University of Rio de Janeiro Rio de Janeiro Brazil
3 shared publications- Patrícia de Andrade Risso
Associate Professor, Department de Dental Clinics (Endodontics), Faculty of Dentistry, Universidade Federal do Rio de Janeiro, Brazil
3 shared publications - José Mauro Granjeiro
Instituto Nacional de Metrologia, Qualidade e Tecnologia (Inmetro)
2 shared publications L. R. L. Aboud
Department of Metallurgy and Materials Federal University of Rio de Janeiro Rio de Janeiro Brazil
2 shared publications- Adriana Barbosa da Silva
Universidade Federal do Rio de Janeiro, Brazil
1 shared publication
Latest Publications
- Open Access
- 29 July 2026
- Published by Elsevier in Journal of Endodontics
- Vol. 52 (11) , 1850-1860
Accuracy and Completeness of Four Artificial Intelligence Chatbots in Assisting Diagnosis and Treatment of Post-traumatic Endodontic Sequelae
- 29 July 2026
- Published by Elsevier in Journal of Endodontics
- Vol. 52 (11) , 1850-1860
Open AccessAccuracy and Completeness of Four Artificial Intelligence Chatbots in Assisting Diagnosis and Treatment of Post-traumatic Endodontic Sequelae
- Open Access
- 6 March 2024
- Published by Medknow in Journal of Conservative Dentistry and Endodontics
- Vol. 27 (3) , 246-251
Root canal dentin wear during final irrigation in endodontic retreatment with passive ultrasonic irrigation and easy clean instruments
Context: Complementary procedures have been proposed to improve the endodontic retreatments. Aim: The aim of this study was to evaluate, by microcomputed tomography (micro-CT), the dentin wear caused by passive ultrasonic irrigation (PUI) and easy clean (EC) instruments, when used for the final removal of filling material during endodontic retreatment. Methods: Thirty-six mesial roots of the lower first molars were divided into four groups (n = 9), according to the final irrigation and sealer: PUI/AH Plus, EC/AH Plus, PUI/Total Fill (TF), and EC/TF. Canal volume was evaluated, both before and after the final irrigation, by micro-CT analysis. The Kruskal–Wallis test was used to compare the volumes among groups and the paired Wilcoxon test was used to compare the volume values before and after the final irrigation within each group. Results: Both complementary cleaning procedures promoted dentin wear that was observed only when the volume was analyzed for each third of the root canal. In the apical third, both instruments showed significant wear, where the use of the EC instrument resulted in greater wear than the PUI, in teeth filled with both AH Plus and TF BC Sealers (P < 0.05). Conclusion: Both complementary cleaning procedures promoted dentin wear and must be used cautiously.
- 6 March 2024
- Published by Medknow in Journal of Conservative Dentistry and Endodontics
- Vol. 27 (3) , 246-251
Open AccessRoot canal dentin wear during final irrigation in endodontic retreatment with passive ultrasonic irrigation and easy clean instruments
Context: Complementary procedures have been proposed to improve the endodontic retreatments. Aim: The aim of this study was to evaluate, by microcomputed tomography (micro-CT), the dentin wear caused by passive ultrasonic irrigation (PUI) and easy clean (EC) instruments, when used for the final removal of filling material during endodontic retreatment. Methods: Thirty-six mesial roots of the lower first molars were divided into four groups (n = 9), according to the final irrigation and sealer: PUI/AH Plus, EC/AH Plus, PUI/Total Fill (TF), and EC/TF. Canal volume was evaluated, both before and after the final irrigation, by micro-CT analysis. The Kruskal–Wallis test was used to compare the volumes among groups and the paired Wilcoxon test was used to compare the volume values before and after the final irrigation within each group. Results: Both complementary cleaning procedures promoted dentin wear that was observed only when the volume was analyzed for each third of the root canal. In the apical third, both instruments showed significant wear, where the use of the EC instrument resulted in greater wear than the PUI, in teeth filled with both AH Plus and TF BC Sealers (P < 0.05). Conclusion: Both complementary cleaning procedures promoted dentin wear and must be used cautiously.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 36, e015
Ionic concentration in periradicular medium after dissolution of endodontic file fragments: an in vitro study
The aim of this study was to obtain ionic quantification in periradicular medium after diffusion tests of the solution used inside root canals during the electrochemical dissolution of endodontic file fragments and the NiTi-containing dissolution product via an apical foramen. Thirty single-rooted extracted human teeth had root canals prepared and were attached to Eppendorf tubes filled with sterile saline. The samples were divided into 3 groups (n = 10) according to the solution used inside the root canal during the diffusion tests: Group 1: [NaF 12 g/L + NaCl 1 g/L]; Group 2: [NaF 12 g/L + NaCl 1 g/L + NiTi 0.50 g/L]; Group 3: [NaF 6 g/L + NaCl 0.5 g/L + NiTi 0.25 g/L]. The sample in each Eppendorf tube was then analyzed to assay the ionic quantification in periradicular medium. The groups were compared in relation to ionic quantifications (Kruskal-Wallis and Dunn's tests, p ≤ 0.05). Group 2 showed significantly higher F-, Ni and Ti quantities than groups 1 and 3 (p < 0.05). Group 3 showed significantly higher Ti and Ni quantities than group 1, where no measurable quantities of Ti and Ni were observed (p < 0.05). The conclusions were that a 50% dilution of the NiTi-containing dissolution product resulted in significantly lower F-, Ni and Ti quantities compared to the undiluted product. The quantifications observed here suggest that irrigation is recommendable during the electrochemical dissolution process to reduce the resultant ion concentrations in both the root canal and the periradicular medium.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 36, e015
Open AccessIonic concentration in periradicular medium after dissolution of endodontic file fragments: an in vitro study
The aim of this study was to obtain ionic quantification in periradicular medium after diffusion tests of the solution used inside root canals during the electrochemical dissolution of endodontic file fragments and the NiTi-containing dissolution product via an apical foramen. Thirty single-rooted extracted human teeth had root canals prepared and were attached to Eppendorf tubes filled with sterile saline. The samples were divided into 3 groups (n = 10) according to the solution used inside the root canal during the diffusion tests: Group 1: [NaF 12 g/L + NaCl 1 g/L]; Group 2: [NaF 12 g/L + NaCl 1 g/L + NiTi 0.50 g/L]; Group 3: [NaF 6 g/L + NaCl 0.5 g/L + NiTi 0.25 g/L]. The sample in each Eppendorf tube was then analyzed to assay the ionic quantification in periradicular medium. The groups were compared in relation to ionic quantifications (Kruskal-Wallis and Dunn's tests, p ≤ 0.05). Group 2 showed significantly higher F-, Ni and Ti quantities than groups 1 and 3 (p < 0.05). Group 3 showed significantly higher Ti and Ni quantities than group 1, where no measurable quantities of Ti and Ni were observed (p < 0.05). The conclusions were that a 50% dilution of the NiTi-containing dissolution product resulted in significantly lower F-, Ni and Ti quantities compared to the undiluted product. The quantifications observed here suggest that irrigation is recommendable during the electrochemical dissolution process to reduce the resultant ion concentrations in both the root canal and the periradicular medium.
- Open Access
- 15 February 2021
- Published by Universidade Estadual de Campinas in Brazilian Journal of Oral Sciences
- Vol. 20, e210432
Retreatment of mesial roots of mandibular molars filled with resin- based and bioceramic sealers
Aim: The aim of this study was to evaluate, by micro-computed tomography (micro-CT) analysis, the remaining filling material during endodontic retreatment performed with Protaper retreatment without solvent. Methods: Forty mandibular molars were divided into two groups (n = 20) according to the sealer used in the obturation: the bioceramic TotalFill BC (TF) or the resin-based AH Plus (AHP). The specimens were scanned before instrumentation, after obturation and after filling removal. Only the mesial roots were analysed. The filling volumes and the remaining filling material were calculated in the entire root canal and in the cervical, middle and apical thirds. Results: The volume of obturation and the volume of remaining filling material in the entire root canal and in the cervical, middle and apical thirds of the canal between the groups were not statistically different (independent t-test, p > 0.05). In the AHP group, there was a higher percentage of remaining filling material in the middle third than in the cervical third (p < 0.05). Conclusion: The filling material could not be entirely removed from any specimen.
- 15 February 2021
- Published by Universidade Estadual de Campinas in Brazilian Journal of Oral Sciences
- Vol. 20, e210432
Open AccessRetreatment of mesial roots of mandibular molars filled with resin- based and bioceramic sealers
Aim: The aim of this study was to evaluate, by micro-computed tomography (micro-CT) analysis, the remaining filling material during endodontic retreatment performed with Protaper retreatment without solvent. Methods: Forty mandibular molars were divided into two groups (n = 20) according to the sealer used in the obturation: the bioceramic TotalFill BC (TF) or the resin-based AH Plus (AHP). The specimens were scanned before instrumentation, after obturation and after filling removal. Only the mesial roots were analysed. The filling volumes and the remaining filling material were calculated in the entire root canal and in the cervical, middle and apical thirds. Results: The volume of obturation and the volume of remaining filling material in the entire root canal and in the cervical, middle and apical thirds of the canal between the groups were not statistically different (independent t-test, p > 0.05). In the AHP group, there was a higher percentage of remaining filling material in the middle third than in the cervical third (p < 0.05). Conclusion: The filling material could not be entirely removed from any specimen.
- 7 August 2020
- Published by Wiley in International Endodontic Journal
- Vol. 53 (11) , 1559-1568
Electrochemical dissolution of nickel‐titanium instrument fragments in root canals of extracted human maxillary molars using a small reservoir of electrolyte
Aim: To evaluate the viability of the electrochemical dissolution of fragments of fractured NiTi instruments in root canals of extracted human maxillary molars, using two electrodes and the solution restricted to a small reservoir coupled to the pulp chamber. The primary hypothesis was that this method enables the reduction of fragment volume and re‐establishment of the root canal path with a size 08 K‐file, both in simulated canals and in extracted human maxillary molars.Methodology: Fragments of F1 ProTaper instruments were polarized in simulated root canals and in distobuccal root canals of extracted maxillary molars using a new method, with the solution restricted to a small acrylic microcell coupled to each resin block or pulp chamber. Two electrodes were used, where one was kept in contact with the intracanal fragment and another was positioned in the solution present in the acrylic microcell. After the tests, a size 08 K‐file was used passively to verify the possibility of bypassing the fragment, which was also confirmed by radiographic analysis. Micro‐CT analysis of the teeth was used before and after fragment dissolution to evaluate the volume, length and porosity of the fragments. The D'Agostino–Pearson normality test was used to verify the distribution of the data. A paired t‐test (P < 0.05) was used to compare the volume, length and porosity of the fragments before and after the dissolution tests.Results: After dissolution, all fragments could be bypassed with a size 08 K‐file in both simulated canals and in extracted teeth. The dissolution process did not result in significant reduction of neither the fragment length nor the fragment porosity. However, it resulted in a significant reduction of fragment volume (paired t‐test, P < 0.05).Conclusion: The electrochemical dissolution of fragments of NiTi files in root canals of extracted human maxillary molars using two electrodes, and the solution restricted to a small reservoir coupled to the pulp chamber resulted in a significant reduction of fragment volume. The re‐establishment of the root canal path with the passive insertion of size 08 K‐files was possible in all samples after the tests, both in simulated canals and in extracted teeth.
- 7 August 2020
- Published by Wiley in International Endodontic Journal
- Vol. 53 (11) , 1559-1568
Electrochemical dissolution of nickel‐titanium instrument fragments in root canals of extracted human maxillary molars using a small reservoir of electrolyte
Aim: To evaluate the viability of the electrochemical dissolution of fragments of fractured NiTi instruments in root canals of extracted human maxillary molars, using two electrodes and the solution restricted to a small reservoir coupled to the pulp chamber. The primary hypothesis was that this method enables the reduction of fragment volume and re‐establishment of the root canal path with a size 08 K‐file, both in simulated canals and in extracted human maxillary molars.Methodology: Fragments of F1 ProTaper instruments were polarized in simulated root canals and in distobuccal root canals of extracted maxillary molars using a new method, with the solution restricted to a small acrylic microcell coupled to each resin block or pulp chamber. Two electrodes were used, where one was kept in contact with the intracanal fragment and another was positioned in the solution present in the acrylic microcell. After the tests, a size 08 K‐file was used passively to verify the possibility of bypassing the fragment, which was also confirmed by radiographic analysis. Micro‐CT analysis of the teeth was used before and after fragment dissolution to evaluate the volume, length and porosity of the fragments. The D'Agostino–Pearson normality test was used to verify the distribution of the data. A paired t‐test (P < 0.05) was used to compare the volume, length and porosity of the fragments before and after the dissolution tests.Results: After dissolution, all fragments could be bypassed with a size 08 K‐file in both simulated canals and in extracted teeth. The dissolution process did not result in significant reduction of neither the fragment length nor the fragment porosity. However, it resulted in a significant reduction of fragment volume (paired t‐test, P < 0.05).Conclusion: The electrochemical dissolution of fragments of NiTi files in root canals of extracted human maxillary molars using two electrodes, and the solution restricted to a small reservoir coupled to the pulp chamber resulted in a significant reduction of fragment volume. The re‐establishment of the root canal path with the passive insertion of size 08 K‐files was possible in all samples after the tests, both in simulated canals and in extracted teeth.
- 15 May 2018
- Published by Wiley in International Endodontic Journal
- Vol. 51 (12) , 1434-1445
Evaluation of the effects of the solution used for electrochemical dissolution of nickel–titanium endodontic files on dentine structure, microhardness and cell viability
Aim: To evaluate the effects of the [NaF 12 g L−1 + NaCl 1 g L−1] solution used in the electrochemical dissolution process of fractured endodontic files, as well as its NiTi‐containing product, on dentine hardness, topography and human fibroblast viability.Methodology: Sixty single‐rooted human teeth were evaluated for dentine microhardness using the Vickers hardness test and the area and number of dentinal tubules by scanning electron microscopy. The samples were divided according to the dentine surface treatment: distilled water; 17% EDTA; [NaF 12 g L−1 + NaCl 1 g L−1]; and 17% EDTA + [NaF 12 g L−1 + NaCl 1 g L−1]. Thirty‐six single‐rooted human teeth were divided according to the irrigation protocol: Dulbecco's Modified Eagle's Medium + 10% foetal bovine serum; 5.25% NaOCl; [NaF 12 g L−1 + NaCl 1 g L−1]; and [NaF 12 g L−1 + NaCl 1 g L−1 + NiTi]. The extracts in contact with the apical foramen were used in the MTT assay to evaluate human fibroblast viability, with dilutions of 100%, 50%, 25% and 12.5%. Statistical tests used were paired t‐tests, one‐way anova, Tukey's test, Kruskal–Wallis test and Dunn's post‐test.Results: The [NaF 12 g L−1 + NaCl 1 g L−1] solution did not modify dentine microhardness or the average dentinal tubule area. However, EDTA induced changes in dentine structure and microhardness (P < 0.05). The [NaF 12 g L−1 + NaCl 1 g L−1] solution, and its NiTi‐containing product had lower cytotoxicity than NaOCl at dilutions of 25% and 50% (P < 0.01).Conclusions: The [NaF 12 g L−1 + NaCl 1 g L−1] solution did not alter dentine microhardness or damage the dentine structure. It also demonstrated lower cytotoxicity than NaOCl.
- 15 May 2018
- Published by Wiley in International Endodontic Journal
- Vol. 51 (12) , 1434-1445
Evaluation of the effects of the solution used for electrochemical dissolution of nickel–titanium endodontic files on dentine structure, microhardness and cell viability
Aim: To evaluate the effects of the [NaF 12 g L−1 + NaCl 1 g L−1] solution used in the electrochemical dissolution process of fractured endodontic files, as well as its NiTi‐containing product, on dentine hardness, topography and human fibroblast viability.Methodology: Sixty single‐rooted human teeth were evaluated for dentine microhardness using the Vickers hardness test and the area and number of dentinal tubules by scanning electron microscopy. The samples were divided according to the dentine surface treatment: distilled water; 17% EDTA; [NaF 12 g L−1 + NaCl 1 g L−1]; and 17% EDTA + [NaF 12 g L−1 + NaCl 1 g L−1]. Thirty‐six single‐rooted human teeth were divided according to the irrigation protocol: Dulbecco's Modified Eagle's Medium + 10% foetal bovine serum; 5.25% NaOCl; [NaF 12 g L−1 + NaCl 1 g L−1]; and [NaF 12 g L−1 + NaCl 1 g L−1 + NiTi]. The extracts in contact with the apical foramen were used in the MTT assay to evaluate human fibroblast viability, with dilutions of 100%, 50%, 25% and 12.5%. Statistical tests used were paired t‐tests, one‐way anova, Tukey's test, Kruskal–Wallis test and Dunn's post‐test.Results: The [NaF 12 g L−1 + NaCl 1 g L−1] solution did not modify dentine microhardness or the average dentinal tubule area. However, EDTA induced changes in dentine structure and microhardness (P < 0.05). The [NaF 12 g L−1 + NaCl 1 g L−1] solution, and its NiTi‐containing product had lower cytotoxicity than NaOCl at dilutions of 25% and 50% (P < 0.01).Conclusions: The [NaF 12 g L−1 + NaCl 1 g L−1] solution did not alter dentine microhardness or damage the dentine structure. It also demonstrated lower cytotoxicity than NaOCl.
- Open Access
- 29 February 2016
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 10 (1) , 12-18
Ability of Three Endodontic Sealers to Fill the Root Canal System in Association with Gutta-Percha
Introduction: The present study compared the ability of the endodontic sealers AH Plus, Pulp Canal Sealer and EndoREZ to fill the root canal system in association with gutta-percha. Methods: Ninety mandibular premolars were accessed, prepared and divided into three groups of 30 teeth each, according to the sealer used to fill the canals: AH Plus, Pulp Canal Sealer and EndoREZ. All the teeth were filled using the continuous wave of condensation technique. The specimens were then decalcified, dehydrated, rendered transparent, and analyzed by three independent evaluators with 8x magnification. Chi-squared test (χ2, p < 0.05) was used to compare the groups in relation to the totally filled, the partially filled and the non filled ramifications. The same test was used to compare the directions of filled ramifications and the number of ramifications among the three thirds of the roots. Results: EndoREZ filled a significantly higher number of ramifications than AH Plus and Pulp Canal Sealer (χ2, p < 0.05). All the groups showed higher number of totally filled ramifications than partially filled and unfilled ramifications. The ramifications were more frequently detected in the apical third, followed by medium and coronal thirds, respectively (χ2, p < 0.05). The ramifications were more frequently detected towards lingual direction (χ2, p < 0.05). Conclusion: EndoREZ presented higher ability to fill the root canal system in association with gutta-percha when compared to AH Plus and Pulp Canal Sealer. The ramifications were more frequently detected in the apical third, running in a lingual direction.
- 29 February 2016
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 10 (1) , 12-18
Open AccessAbility of Three Endodontic Sealers to Fill the Root Canal System in Association with Gutta-Percha
Introduction: The present study compared the ability of the endodontic sealers AH Plus, Pulp Canal Sealer and EndoREZ to fill the root canal system in association with gutta-percha. Methods: Ninety mandibular premolars were accessed, prepared and divided into three groups of 30 teeth each, according to the sealer used to fill the canals: AH Plus, Pulp Canal Sealer and EndoREZ. All the teeth were filled using the continuous wave of condensation technique. The specimens were then decalcified, dehydrated, rendered transparent, and analyzed by three independent evaluators with 8x magnification. Chi-squared test (χ2, p < 0.05) was used to compare the groups in relation to the totally filled, the partially filled and the non filled ramifications. The same test was used to compare the directions of filled ramifications and the number of ramifications among the three thirds of the roots. Results: EndoREZ filled a significantly higher number of ramifications than AH Plus and Pulp Canal Sealer (χ2, p < 0.05). All the groups showed higher number of totally filled ramifications than partially filled and unfilled ramifications. The ramifications were more frequently detected in the apical third, followed by medium and coronal thirds, respectively (χ2, p < 0.05). The ramifications were more frequently detected towards lingual direction (χ2, p < 0.05). Conclusion: EndoREZ presented higher ability to fill the root canal system in association with gutta-percha when compared to AH Plus and Pulp Canal Sealer. The ramifications were more frequently detected in the apical third, running in a lingual direction.
- 28 June 2014
- Published by Wiley in International Endodontic Journal
- Vol. 48 (4) , 342-350
Electrochemical‐induced dissolution of nickel–titanium endodontic instruments with different designs
Aim: To compare the active dissolution process of K3, ProTaper and Mtwo NiTi endodontic rotary instruments in chloride and fluoride containing solutions.Methods: Anodic polarization of K3 size 20, 0.06 taper, ProTaper size F1 and MTwo size 20, 0.06 taper instruments was performed, and anova (P < 0.05) was used to compare the weight loss, the time of dissolution and the electrical charge generated by the groups of instruments. Fragments of the instruments were polarized in simulated root canals to evaluate the dissolution process. After the tests, a size 10 K‐file was used to verify whether the fragment could be bypassed. Radiographic analysis of the simulated canals was used before and after the tests to verify fragment dissolution.Results: A progressive consumption of the instruments was observed. K3 and ProTaper instruments had significantly greater weight loss than Mtwo instruments after 30 min of polarization. K3 instruments had the highest values of total electrical charge, and MTwo instruments the lowest (P < 0.05). After 60 min, the anodic polarization of instrument fragments in simulated root canals resulted in their partial dissolution.Conclusion: The anodic polarization of K3, ProTaper and MTwo instruments resulted in their progressive consumption with increasing polarization time. Sixty minutes anodic polarization of the various NiTi instrument fragments in simulated root canals resulted in their partial dissolution.
- 28 June 2014
- Published by Wiley in International Endodontic Journal
- Vol. 48 (4) , 342-350
Electrochemical‐induced dissolution of nickel–titanium endodontic instruments with different designs
Aim: To compare the active dissolution process of K3, ProTaper and Mtwo NiTi endodontic rotary instruments in chloride and fluoride containing solutions.Methods: Anodic polarization of K3 size 20, 0.06 taper, ProTaper size F1 and MTwo size 20, 0.06 taper instruments was performed, and anova (P < 0.05) was used to compare the weight loss, the time of dissolution and the electrical charge generated by the groups of instruments. Fragments of the instruments were polarized in simulated root canals to evaluate the dissolution process. After the tests, a size 10 K‐file was used to verify whether the fragment could be bypassed. Radiographic analysis of the simulated canals was used before and after the tests to verify fragment dissolution.Results: A progressive consumption of the instruments was observed. K3 and ProTaper instruments had significantly greater weight loss than Mtwo instruments after 30 min of polarization. K3 instruments had the highest values of total electrical charge, and MTwo instruments the lowest (P < 0.05). After 60 min, the anodic polarization of instrument fragments in simulated root canals resulted in their partial dissolution.Conclusion: The anodic polarization of K3, ProTaper and MTwo instruments resulted in their progressive consumption with increasing polarization time. Sixty minutes anodic polarization of the various NiTi instrument fragments in simulated root canals resulted in their partial dissolution.
- 12 May 2014
- Published by Wiley in International Endodontic Journal
- Vol. 48 (2) , 137-144
Electrochemical‐induced dissolution of stainless steel files
Aim: To investigate the effectiveness of the dissolution process when hand stainless steel files are polarized in solutions containing chloride and fluoride to promote their dissolution.Methodology: Redox curves and anodic polarization curves were obtained to determine the conditions necessary for the dissolution of stainless steel endodontic files. Anodic polarization of sizes 20 and 30 files was performed, and a t‐test (P < 0.05) was used to compare the weight loss, the time of dissolution and the electrical charge generated by both groups of files. Fragments were polarized in simulated root canals to evaluate the dissolution process. After the tests, a size 10 K‐file was used to verify the possibility of bypassing the fragment. Radiographic analysis of the simulated canals was used before and after the tests to verify fragment dissolution.Results: A progressive consumption of the sizes 20 and 30 files was observed with total polarization times of 7.0 and 9.0 min, respectively. Files with the larger diameters exhibited greater weight loss, longer times of dissolution and generated a greater electrical charge during the active dissolution process (t‐test, P < 0.05). After 60 min, the anodic polarization of file fragments in simulated root canals resulted in their partial dissolution.Conclusion: A 60‐min anodic polarization of stainless steel K‐file fragments in simulated root canals resulted in their partial dissolution. The fragments could be bypassed after the test.
- 12 May 2014
- Published by Wiley in International Endodontic Journal
- Vol. 48 (2) , 137-144
Electrochemical‐induced dissolution of stainless steel files
Aim: To investigate the effectiveness of the dissolution process when hand stainless steel files are polarized in solutions containing chloride and fluoride to promote their dissolution.Methodology: Redox curves and anodic polarization curves were obtained to determine the conditions necessary for the dissolution of stainless steel endodontic files. Anodic polarization of sizes 20 and 30 files was performed, and a t‐test (P < 0.05) was used to compare the weight loss, the time of dissolution and the electrical charge generated by both groups of files. Fragments were polarized in simulated root canals to evaluate the dissolution process. After the tests, a size 10 K‐file was used to verify the possibility of bypassing the fragment. Radiographic analysis of the simulated canals was used before and after the tests to verify fragment dissolution.Results: A progressive consumption of the sizes 20 and 30 files was observed with total polarization times of 7.0 and 9.0 min, respectively. Files with the larger diameters exhibited greater weight loss, longer times of dissolution and generated a greater electrical charge during the active dissolution process (t‐test, P < 0.05). After 60 min, the anodic polarization of file fragments in simulated root canals resulted in their partial dissolution.Conclusion: A 60‐min anodic polarization of stainless steel K‐file fragments in simulated root canals resulted in their partial dissolution. The fragments could be bypassed after the test.
- 9 May 2013
- Published by Wiley in International Endodontic Journal
- Vol. 47 (2) , 155-162
Electrochemical induced dissolution of fragments of nickel–titanium endodontic files and their removal from simulated root canals
Aim: To improve the dissolution process of NiTi endodontic rotary files aiming at fragment removal and the recovery of the original path of the root canal during a clinically acceptable period of time.Methodology: Anodic polarization curves and redox curves were obtained to determine the conditions necessary for the dissolution of endodontic files. Anodic polarization of K3 files was performed, and analysis of variance (P < 0.05) was used to compare different test times in relation to weight loss, length loss and electrical charge generated in each solution. The polarization of fragments in simulated root canals was undertaken to evaluate the dissolution process. After the tests, a size 10 K‐file was used to verify the possibility to bypass the fragment. The total electrical charge of each test was obtained from the corresponding graph area. Radiographic analysis of the simulated canals was used before and after the tests to verify fragment dissolution.Results: The weight loss values, the length loss values and the total values of electrical charge in each period of time were significantly higher (P < 0.05) in the tests using the selected solution compared with the solution previously proposed. A progressive consumption of the K3 file tip was observed up to 30 min. The anodic polarization of file fragments in simulated root canals for 60 min resulted in their partial dissolution and enabled the recovery of the original canal pathway with size 10 K‐files.Conclusions: Increasing fluoride concentration resulted in greater active dissolution of NiTi files. The dissolution of fractured files in simulated root canals enabled the recovery of its original path during a clinically acceptable period of time.
- 9 May 2013
- Published by Wiley in International Endodontic Journal
- Vol. 47 (2) , 155-162
Electrochemical induced dissolution of fragments of nickel–titanium endodontic files and their removal from simulated root canals
Aim: To improve the dissolution process of NiTi endodontic rotary files aiming at fragment removal and the recovery of the original path of the root canal during a clinically acceptable period of time.Methodology: Anodic polarization curves and redox curves were obtained to determine the conditions necessary for the dissolution of endodontic files. Anodic polarization of K3 files was performed, and analysis of variance (P < 0.05) was used to compare different test times in relation to weight loss, length loss and electrical charge generated in each solution. The polarization of fragments in simulated root canals was undertaken to evaluate the dissolution process. After the tests, a size 10 K‐file was used to verify the possibility to bypass the fragment. The total electrical charge of each test was obtained from the corresponding graph area. Radiographic analysis of the simulated canals was used before and after the tests to verify fragment dissolution.Results: The weight loss values, the length loss values and the total values of electrical charge in each period of time were significantly higher (P < 0.05) in the tests using the selected solution compared with the solution previously proposed. A progressive consumption of the K3 file tip was observed up to 30 min. The anodic polarization of file fragments in simulated root canals for 60 min resulted in their partial dissolution and enabled the recovery of the original canal pathway with size 10 K‐files.Conclusions: Increasing fluoride concentration resulted in greater active dissolution of NiTi files. The dissolution of fractured files in simulated root canals enabled the recovery of its original path during a clinically acceptable period of time.