Martin Michael Kaiser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Martin Michael Kaiser has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Christine Stratmann
Department of Pediatric Surgery, University Medical Centre Schleswig-Holstein, Campus Luebeck, Ratezburger Allee 160, 23538 Lübeck, Germany
2 shared publications M. Rapp
Klinik für Kinder- und Jugendmedizin, Universität zu Lübeck, Lübeck, Deutschland
2 shared publications- Marion Rapp
Department of Paediatrics, University of Lübeck, Lübeck, Germany
2 shared publications - Rebecca Eggert
Department of Pediatric Surgery, University Medical Centre Schleswig-Holstein, Campus Luebeck, Ratezburger Allee 160, 23538 Lübeck, Germany
2 shared publications A. Kamphaus
Klinik für Kinderchirurgie, Universitätsklinikum Schleswig-Holstein, Universität zu Lübeck, Campus Lübeck, Ratzeburger Allee 160, 23538, Lübeck, Deutschland
1 shared publication- Arndt-Peter Schulz
BG Klinikum Hamburg, Hamburg, Germany
1 shared publication
Latest Publications
- Open Access
- 25 June 2015
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 10 (1) , 1-8
Improving stability of elastic stable intramedullary nailing in a transverse midshaft femur fracture model: biomechanical analysis of using end caps or a third nail
Elastic stable intramedullary nailing (ESIN) is accepted widely for treatment of diaphyseal femur fractures in children. However, complication rates of 10 to 50 % are described due to shortening or axial deviation, especially in older or heavier children. Biomechanical in vitro testing was performed to determine whether two modified osteosyntheses with end caps or a third nail could significantly improve the stability in comparison to classical elastic stable intramedullary nailing in a transverse femur fracture model. We performed biomechanical testing in 24 synthetic adolescent femoral bone models (Sawbones®) with a transverse midshaft (diaphyseal) fracture. First, in all models, two nails were inserted in a C-shaped manner (2 × 3.5 mm steel nails, prebent), then eight osteosyntheses were modified by using end caps and another eight by adding a third nail from the antero-lateral (2.5-mm steel, not prebent). Testing was performed in four-point bending, torsion, and shifting under physiological 9° compression. The third nail from the lateral showed a significant positive influence on the stiffness in all four-point bendings as well as in internal rotation comparing to the classical 2C configuration: mean values were significantly higher anterior-posterior (1.04 vs. 0.52 Nm/mm, p < 0.001), posterior-anterior (0.85 vs. 0.43 Nm/mm, p < 0.001), lateral-medial (1.26 vs. 0.70 Nm/mm, p < 0.001), and medial-lateral (1.16 vs. 0.76 Nm/mm, p < 0.001) and during internal rotation (0.16 vs. 0.11 Nm/°, p < 0.001). The modification with end caps did not improve the stiffness in any direction. The configuration with a third nail provided a significantly higher stiffness than the classical 2C configuration as well as the modification with end caps in this biomechanical model. This supports the ongoing transfer of the additional third nail into clinical practice to reduce the axial deviation occurring in clinical practice.
- 25 June 2015
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 10 (1) , 1-8
Open AccessImproving stability of elastic stable intramedullary nailing in a transverse midshaft femur fracture model: biomechanical analysis of using end caps or a third nail
Elastic stable intramedullary nailing (ESIN) is accepted widely for treatment of diaphyseal femur fractures in children. However, complication rates of 10 to 50 % are described due to shortening or axial deviation, especially in older or heavier children. Biomechanical in vitro testing was performed to determine whether two modified osteosyntheses with end caps or a third nail could significantly improve the stability in comparison to classical elastic stable intramedullary nailing in a transverse femur fracture model. We performed biomechanical testing in 24 synthetic adolescent femoral bone models (Sawbones®) with a transverse midshaft (diaphyseal) fracture. First, in all models, two nails were inserted in a C-shaped manner (2 × 3.5 mm steel nails, prebent), then eight osteosyntheses were modified by using end caps and another eight by adding a third nail from the antero-lateral (2.5-mm steel, not prebent). Testing was performed in four-point bending, torsion, and shifting under physiological 9° compression. The third nail from the lateral showed a significant positive influence on the stiffness in all four-point bendings as well as in internal rotation comparing to the classical 2C configuration: mean values were significantly higher anterior-posterior (1.04 vs. 0.52 Nm/mm, p < 0.001), posterior-anterior (0.85 vs. 0.43 Nm/mm, p < 0.001), lateral-medial (1.26 vs. 0.70 Nm/mm, p < 0.001), and medial-lateral (1.16 vs. 0.76 Nm/mm, p < 0.001) and during internal rotation (0.16 vs. 0.11 Nm/°, p < 0.001). The modification with end caps did not improve the stiffness in any direction. The configuration with a third nail provided a significantly higher stiffness than the classical 2C configuration as well as the modification with end caps in this biomechanical model. This supports the ongoing transfer of the additional third nail into clinical practice to reduce the axial deviation occurring in clinical practice.
- Open Access
- 8 January 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 3
Modification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model – results of biomechanical testing and a prospective clinical study
Elastic stable intramedullary nailing (ESIN) is the standard treatment for displaced diaphyseal femoral fractures in children. However, high complication rates (10-50%) are reported in complex fractures. This biomechanical study compares the stiffness with a 3rd nail implanted to that in the classical 2C-shaped configuration and presents the application into clinical practice.
- 8 January 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 3
Open AccessModification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model – results of biomechanical testing and a prospective clinical study
Elastic stable intramedullary nailing (ESIN) is the standard treatment for displaced diaphyseal femoral fractures in children. However, high complication rates (10-50%) are reported in complex fractures. This biomechanical study compares the stiffness with a 3rd nail implanted to that in the classical 2C-shaped configuration and presents the application into clinical practice.
- 14 November 2013
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 16 (S1) , 68-75
Suprakondyläre und subkapitale Humerusfrakturen
- 14 November 2013
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 16 (S1) , 68-75
Suprakondyläre und subkapitale Humerusfrakturen
- 1 September 2013
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 33 (6) , 608-613
Elastic Stable Intramedullary Nailing for Displaced Pediatric Clavicle Midshaft Fractures
Background: Whereas displaced clavicle fractures in young children are treated nonoperatively, older children are more likely to suffer persistent pain and misalignments during a longer period of treatment. This study presents the outcomes of elastic stable intramedullary nailing for displaced clavicle fractures in children over the age of 10. Methods: Prospectively, this study evaluates elastic stable intramedullary nailing for displaced clavicle midshaft fractures in children and adolescents, aged 10 to 15 years, from July 2004 to June 2010. We analyzed all complications, patient pain and long-term results, measured using the Constant & Murley Shoulder Score, the Client Satisfaction Questionnaire-8, and ultrasound. Results: Eight girls and 16 boys (aged 10 to 15 y), 1 with bilateral fracture, were recruited. Sixteen mini-open reductions were necessary. All adolescents reported full mobilization from the first postoperative day, full activity after 1 week, and sporting activity after 1 month. Self-reported pain was very low. Five complications occurred: 1 implant breakage (kick-boxing); 2 nail deformations (fall during football, collision in ice-hockey); and 2 imminent skin perforations. The mean Constant & Murley Shoulder Score at follow-up after 1 year was 99.5 of 100 points; the mean patient satisfaction in the Client Satisfaction Questionnaire-8 was 30.6 of 32 points. Axial deviation of the clavicle was always <10 degrees; shortening <0.5 cm. Conclusions: Elastic stable intramedullary nailing can be offered for displaced midshaft clavicle fractures in children older than 10 years. They benefit from little pain, early mobilization, and fast full range of motion. To avoid complications the maximum projection of the ends of the nails must be 5 mm; no sports should be allowed for 4 weeks, contact sports for 8 weeks. Level of Evidence: Level IV.
- 1 September 2013
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 33 (6) , 608-613
Elastic Stable Intramedullary Nailing for Displaced Pediatric Clavicle Midshaft Fractures
Background: Whereas displaced clavicle fractures in young children are treated nonoperatively, older children are more likely to suffer persistent pain and misalignments during a longer period of treatment. This study presents the outcomes of elastic stable intramedullary nailing for displaced clavicle fractures in children over the age of 10. Methods: Prospectively, this study evaluates elastic stable intramedullary nailing for displaced clavicle midshaft fractures in children and adolescents, aged 10 to 15 years, from July 2004 to June 2010. We analyzed all complications, patient pain and long-term results, measured using the Constant & Murley Shoulder Score, the Client Satisfaction Questionnaire-8, and ultrasound. Results: Eight girls and 16 boys (aged 10 to 15 y), 1 with bilateral fracture, were recruited. Sixteen mini-open reductions were necessary. All adolescents reported full mobilization from the first postoperative day, full activity after 1 week, and sporting activity after 1 month. Self-reported pain was very low. Five complications occurred: 1 implant breakage (kick-boxing); 2 nail deformations (fall during football, collision in ice-hockey); and 2 imminent skin perforations. The mean Constant & Murley Shoulder Score at follow-up after 1 year was 99.5 of 100 points; the mean patient satisfaction in the Client Satisfaction Questionnaire-8 was 30.6 of 32 points. Axial deviation of the clavicle was always <10 degrees; shortening <0.5 cm. Conclusions: Elastic stable intramedullary nailing can be offered for displaced midshaft clavicle fractures in children older than 10 years. They benefit from little pain, early mobilization, and fast full range of motion. To avoid complications the maximum projection of the ends of the nails must be 5 mm; no sports should be allowed for 4 weeks, contact sports for 8 weeks. Level of Evidence: Level IV.
- 17 August 2013
- Published by Springer Nature in Der Unfallchirurg
- Vol. 118 (4) , 326-335
LiLa-Klassifikation für Frakturen der langen Röhrenknochen im Wachstumsalter
Zusammenfassung Hintergrund Neben der AO-Klassifikation für Frakturen im Wachstumsalter (PCCF, „Pediatric Comprehensive Classification of Long-Bone Fractures“) gibt es die LiLa-Klassifikation für Frakturen der langen Röhrenknochen im Wachstumsalter (LiLa-Klassifikation). Letztere sollte im Rahmen dieser Arbeit unter klinisch relevanten Bedingungen auf ihre Reliabilität und Praktikabilität geprüft werden. Methode Prospektiv wurden in einem Kindertraumazentrum über 12 Monate sämtliche Frakturen der langen Röhrenknochen erfasst und unabhängig von Experten und Laien nach der LiLa-Klassifikation kodiert und die Intra-/Interobserverreliabilität nach Cohen (Kappa, κ) berechnet. Ergebnis Klassifiziert wurden 408 Frakturen. Die Intraobserverreliabilität für Frakturlokalisation und Knochensegment ergab ein „almost perfect agreement“ (κ = 0,91–0,95), ebenso die Angabe hinsichtlich Gelenk- oder Schaftfraktur (κ = 0,87–0,93). Aufgrund der oft höhergradigen Einstufung des Dislokationsausmaßes in der 2. Beurteilung lag bei der Intraobserverbetrachtung insgesamt ein „moderate agreement“ (κ = 0,53–0,58) vor. Die Interobserverreliabilität für die Gesamtklassifikation zeigte ein „moderate agreement“ (κ = 0,55); dies war im Wesentlichen der Problematik qualitativ schlechter Röntgenbilder und der Klassifikation seltener Frakturen geschuldet, hinzu kam die unterschiedliche Interpretationen der Länge der Metaphyse. Schlussfolgerung Die LiLa-Klassifikation ist für die Klassifikation der Frakturen langen Röhrenknochen im Kindesalter geeignet und weitestgehend anwenderfreundlich; einzig die Einschätzung des Dislokationsgrades erfordert spezifische kindertraumatologische Kenntnisse. Die Reliabilität ist höher als bei anderen etablierten frakturspezifischen Klassifikationen und vergleichbar mit der AO-Klassifikation für Frakturen im Wachstumsalter, könnte allerdings durch eine exaktere Definition der Metaphyse noch deutlich erhöht werden. Klassifikationsunabhängige Fehler entstanden durch qualitativ unzureichende Röntgenbilder und seltene, nicht eindeutig zu klassifizierende Frakturen. Insgesamt kann die LiLa-Klassifikation weiterhin als Option zur Klassifikation von Frakturen der Röhrenknochen des Kindesalters gesehen werden.
- 17 August 2013
- Published by Springer Nature in Der Unfallchirurg
- Vol. 118 (4) , 326-335
LiLa-Klassifikation für Frakturen der langen Röhrenknochen im Wachstumsalter
Zusammenfassung Hintergrund Neben der AO-Klassifikation für Frakturen im Wachstumsalter (PCCF, „Pediatric Comprehensive Classification of Long-Bone Fractures“) gibt es die LiLa-Klassifikation für Frakturen der langen Röhrenknochen im Wachstumsalter (LiLa-Klassifikation). Letztere sollte im Rahmen dieser Arbeit unter klinisch relevanten Bedingungen auf ihre Reliabilität und Praktikabilität geprüft werden. Methode Prospektiv wurden in einem Kindertraumazentrum über 12 Monate sämtliche Frakturen der langen Röhrenknochen erfasst und unabhängig von Experten und Laien nach der LiLa-Klassifikation kodiert und die Intra-/Interobserverreliabilität nach Cohen (Kappa, κ) berechnet. Ergebnis Klassifiziert wurden 408 Frakturen. Die Intraobserverreliabilität für Frakturlokalisation und Knochensegment ergab ein „almost perfect agreement“ (κ = 0,91–0,95), ebenso die Angabe hinsichtlich Gelenk- oder Schaftfraktur (κ = 0,87–0,93). Aufgrund der oft höhergradigen Einstufung des Dislokationsausmaßes in der 2. Beurteilung lag bei der Intraobserverbetrachtung insgesamt ein „moderate agreement“ (κ = 0,53–0,58) vor. Die Interobserverreliabilität für die Gesamtklassifikation zeigte ein „moderate agreement“ (κ = 0,55); dies war im Wesentlichen der Problematik qualitativ schlechter Röntgenbilder und der Klassifikation seltener Frakturen geschuldet, hinzu kam die unterschiedliche Interpretationen der Länge der Metaphyse. Schlussfolgerung Die LiLa-Klassifikation ist für die Klassifikation der Frakturen langen Röhrenknochen im Kindesalter geeignet und weitestgehend anwenderfreundlich; einzig die Einschätzung des Dislokationsgrades erfordert spezifische kindertraumatologische Kenntnisse. Die Reliabilität ist höher als bei anderen etablierten frakturspezifischen Klassifikationen und vergleichbar mit der AO-Klassifikation für Frakturen im Wachstumsalter, könnte allerdings durch eine exaktere Definition der Metaphyse noch deutlich erhöht werden. Klassifikationsunabhängige Fehler entstanden durch qualitativ unzureichende Röntgenbilder und seltene, nicht eindeutig zu klassifizierende Frakturen. Insgesamt kann die LiLa-Klassifikation weiterhin als Option zur Klassifikation von Frakturen der Röhrenknochen des Kindesalters gesehen werden.
- 1 May 2012
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 94-B (5) , 713-718
Increasing stability by pre-bending the nails in elastic stable intramedullary nailing
Elastic stable intramedullary nailing (ESIN) is generally acknowledged to be the treatment of choice for displaced diaphyseal femoral fractures in children over the age of three years, although complication rates of up to 50% are described. Pre-bending the nails is recommended, but there are no published data to support this. Using synthetic bones and a standardised simulated fracture, we performed biomechanical testing to determine the influence on the stability of the fracture of pre-bending the nails before implantation. Standard ESIN was performed on 24 synthetic femoral models with a spiral fracture. In eight cases the nails were inserted without any pre-bending, in a further eight cases they were pre-bent to 30° and in the last group of eight cases they were pre-bent to 60°. Mechanical testing revealed that pre-bending to 60° produced a significant increase in the stiffness or stability of the fracture. Pre-bending to 60° showed a significant positive influence on the stiffness compared with unbent nails. Pre-bending to 30° improved stiffness only slightly. These findings validate the recommendations for pre-bending, but the degree of pre-bend should exceed 30°. Adopting higher degrees of pre-bending should improve stability in spiral fractures and reduce the complications of varus deformity and shortening.
- 1 May 2012
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 94-B (5) , 713-718
Increasing stability by pre-bending the nails in elastic stable intramedullary nailing
Elastic stable intramedullary nailing (ESIN) is generally acknowledged to be the treatment of choice for displaced diaphyseal femoral fractures in children over the age of three years, although complication rates of up to 50% are described. Pre-bending the nails is recommended, but there are no published data to support this. Using synthetic bones and a standardised simulated fracture, we performed biomechanical testing to determine the influence on the stability of the fracture of pre-bending the nails before implantation. Standard ESIN was performed on 24 synthetic femoral models with a spiral fracture. In eight cases the nails were inserted without any pre-bending, in a further eight cases they were pre-bent to 30° and in the last group of eight cases they were pre-bent to 60°. Mechanical testing revealed that pre-bending to 60° produced a significant increase in the stiffness or stability of the fracture. Pre-bending to 60° showed a significant positive influence on the stiffness compared with unbent nails. Pre-bending to 30° improved stiffness only slightly. These findings validate the recommendations for pre-bending, but the degree of pre-bend should exceed 30°. Adopting higher degrees of pre-bending should improve stability in spiral fractures and reduce the complications of varus deformity and shortening.
- Open Access
- 1 January 2011
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 6 (1) , 46
Biomechanical analysis of a synthetic femoral spiral fracture model: Do end caps improve retrograde flexible intramedullary nail fixation?
Elastic Stable intramedullary Nailing (ESIN) of dislocated diaphyseal femur fractures has become an accepted method for the treatment in children and adolescents with open physis. Studies focused on complications of this technique showed problems regarding stability, usually in complex fracture types such as spiral fractures and in older children weighing > 40 kg. Biomechanical in vitro testing was performed to evaluate the stability of simulated spiral femoral fractures after retrograde flexible titanium intramedullary nail fixation with and without End caps.
- 1 January 2011
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 6 (1) , 46
Open AccessBiomechanical analysis of a synthetic femoral spiral fracture model: Do end caps improve retrograde flexible intramedullary nail fixation?
Elastic Stable intramedullary Nailing (ESIN) of dislocated diaphyseal femur fractures has become an accepted method for the treatment in children and adolescents with open physis. Studies focused on complications of this technique showed problems regarding stability, usually in complex fracture types such as spiral fractures and in older children weighing > 40 kg. Biomechanical in vitro testing was performed to evaluate the stability of simulated spiral femoral fractures after retrograde flexible titanium intramedullary nail fixation with and without End caps.