Ryan J. Halter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ryan J. Halter has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Ethan K. Murphy
Dartmouth College
9 shared publications - Joseph A. Paydarfar
Division of Otolaryngology, Audiology and Maxillofacial Surgery Dartmouth‐Hitchcock Medical Center Lebanon New Hampshire USA
4 shared publications - Xiaotian Wu
Dartmouth College
4 shared publications - Curtis Lee Petersen
Division of Geriatric Medicine, UNC School of Medicine, Chapel Hill, USA
3 shared publications - David Kotz
Dartmouth College, Hanover, USA
3 shared publications - John A. Batsis
Department of Nutrition, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
3 shared publications
Latest Publications
- 1 September 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 930
A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery
- 1 September 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 930
A framework for delivering real-time, instrument-relative navigation in transoral robotic surgery
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (7) , 2484-2495
Ex-Vivo Prostate Evaluation of Fused-Data TREIT Using Only Biopsy-Probe Electrodes
This study evaluates a fused-data transrectal electrical impedance tomography (TREIT) method for prostate cancer imaging on a set of 22 ex vivo prostates. A previously optimized TREIT algorithm is utilized, and novel validation and fusion approaches leveraging pathology information are considered. Overall, the aim was to increase the sensed volume of a standard 12-core prostate biopsy by adding TREIT imaging. Two TREIT approaches were considered: 1. including prostate boundary information (EIT-P) and 2. including prostate and tumor boundary information (EIT-P+T). Both simple electrical impedance spectroscopy (EIS) metrics and the two imaging approaches (EIT-P and EIT-P+T) were evaluated with respect to biopsy core, 3D (EIT-P) image, and tumor-grade data. Best AUCs of 0.85, 0.84, and 0.83 were found when considering increasing volumes of tissue (0.8%, 2.7%, and 15% of the prostate). The largest measurement volume (15%), which utilized EIT-P, sensed significantly more prostate tissue than the standard biopsy only approach (<1%). These represent large improvement compared to prior clinical EIS biopsy and TREIT studies. Tumor-grade analysis (via EIT-P+T) appears to show promise but more data is required to confirm this. Overall, the study made important strides in developing the TREIT technique and further investigation, likely in an in vivo study, appears merited.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (7) , 2484-2495
Ex-Vivo Prostate Evaluation of Fused-Data TREIT Using Only Biopsy-Probe Electrodes
This study evaluates a fused-data transrectal electrical impedance tomography (TREIT) method for prostate cancer imaging on a set of 22 ex vivo prostates. A previously optimized TREIT algorithm is utilized, and novel validation and fusion approaches leveraging pathology information are considered. Overall, the aim was to increase the sensed volume of a standard 12-core prostate biopsy by adding TREIT imaging. Two TREIT approaches were considered: 1. including prostate boundary information (EIT-P) and 2. including prostate and tumor boundary information (EIT-P+T). Both simple electrical impedance spectroscopy (EIS) metrics and the two imaging approaches (EIT-P and EIT-P+T) were evaluated with respect to biopsy core, 3D (EIT-P) image, and tumor-grade data. Best AUCs of 0.85, 0.84, and 0.83 were found when considering increasing volumes of tissue (0.8%, 2.7%, and 15% of the prostate). The largest measurement volume (15%), which utilized EIT-P, sensed significantly more prostate tissue than the standard biopsy only approach (<1%). These represent large improvement compared to prior clinical EIS biopsy and TREIT studies. Tumor-grade analysis (via EIT-P+T) appears to show promise but more data is required to confirm this. Overall, the study made important strides in developing the TREIT technique and further investigation, likely in an in vivo study, appears merited.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 311-321
In Vivo Classification of Oral Lesions Using Electrical Impedance Spectroscopy
Objective: To evaluate a new non-invasive, handheld Electrical Impedance Spectroscopy (EIS) device for assessing oral lesions in real-life surgical scenarios. Methods: A custom-designed probe with a 33-electrode sensor array was used to collect impedance measurements across multiple frequencies (100 Hz – 100 kHz) from non-consecutive patients undergoing surgical resection of oral cancer. In vivo EIS measurements were recorded from lesion and healthy tissue surfaces before resection, with no clinical decisions based on impedance data. Results: The study included 26 participants (median [IQR] age, 64.3 [59 – 70] years; 11 (42%) female) with oral squamous cell carcinoma. Cancerous tissue was found to have significantly lower resistance and reactance than healthy tissue (p0.85 for differentiating healthy from malignant tissue. Conclusion & Significance: The study indicates that EIS can effectively differentiate between healthy and cancerous oral mucosa through rapid, non-invasive intraoperative measurements. The data processing pipeline developed demonstrates success in maintaining high data quality amidst the external disturbances presented in intraoperative data collection.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 311-321
In Vivo Classification of Oral Lesions Using Electrical Impedance Spectroscopy
Objective: To evaluate a new non-invasive, handheld Electrical Impedance Spectroscopy (EIS) device for assessing oral lesions in real-life surgical scenarios. Methods: A custom-designed probe with a 33-electrode sensor array was used to collect impedance measurements across multiple frequencies (100 Hz – 100 kHz) from non-consecutive patients undergoing surgical resection of oral cancer. In vivo EIS measurements were recorded from lesion and healthy tissue surfaces before resection, with no clinical decisions based on impedance data. Results: The study included 26 participants (median [IQR] age, 64.3 [59 – 70] years; 11 (42%) female) with oral squamous cell carcinoma. Cancerous tissue was found to have significantly lower resistance and reactance than healthy tissue (p0.85 for differentiating healthy from malignant tissue. Conclusion & Significance: The study indicates that EIS can effectively differentiate between healthy and cancerous oral mucosa through rapid, non-invasive intraoperative measurements. The data processing pipeline developed demonstrates success in maintaining high data quality amidst the external disturbances presented in intraoperative data collection.
- Open Access
- 4 December 2025
- Published by Wolters Kluwer Health in Pain
- Vol. 167 (4) , 880-892
Transcranial direct current stimulation of primary motor cortex reduces thermal pain
Transcranial direct current stimulation (tDCS) is a noninvasive brain stimulation technique with growing potential for pain modulation. However, previous studies have often been limited by small sample sizes, limited outcome reliability, and blinding issues. Pre-registered randomized trials are needed to establish efficacy and reproducibility. Here, we report results from a pre-registered, triple-blind, randomized within-subject crossover trial (N = 50), investigating the effects of left motor cortex (M1) tDCS on experimentally evoked thermal pain in healthy adults. Participants underwent individualized pain calibration, then received anodal, cathodal, and sham M1-tDCS in counterbalanced order on separate visits 4 or more days apart. We assessed post-tDCS thermal pain, potential blinding, side effects, and reaction time during pain rating. Anodal tDCS significantly reduced pain compared with cathodal and sham stimulation ( P < 0.001, Cohen's d = 0.93 and 0.85, respectively; P < 0.001). Cathodal tDCS increased pain relative to sham (Cohen's d = 0.34, P < 0.01). These effects remained stable throughout the 35-minute post-tDCS pain testing period, with no evidence of decay over time. Blinding assessments confirmed that participants were unable to reliably identify the sham session. Anodal tDCS also modestly increased reaction time in the left (ipsilateral) hand ( P < 0.05, Cohen's d = 0.16), consistent with interhemispheric inhibition, which was uncorrelated with analgesia ( P > 0.10). This study provides strong evidence for reliable and polarity-dependent modulation of experimental pain by M1-tDCS.
- 4 December 2025
- Published by Wolters Kluwer Health in Pain
- Vol. 167 (4) , 880-892
Open AccessTranscranial direct current stimulation of primary motor cortex reduces thermal pain
Transcranial direct current stimulation (tDCS) is a noninvasive brain stimulation technique with growing potential for pain modulation. However, previous studies have often been limited by small sample sizes, limited outcome reliability, and blinding issues. Pre-registered randomized trials are needed to establish efficacy and reproducibility. Here, we report results from a pre-registered, triple-blind, randomized within-subject crossover trial (N = 50), investigating the effects of left motor cortex (M1) tDCS on experimentally evoked thermal pain in healthy adults. Participants underwent individualized pain calibration, then received anodal, cathodal, and sham M1-tDCS in counterbalanced order on separate visits 4 or more days apart. We assessed post-tDCS thermal pain, potential blinding, side effects, and reaction time during pain rating. Anodal tDCS significantly reduced pain compared with cathodal and sham stimulation ( P < 0.001, Cohen's d = 0.93 and 0.85, respectively; P < 0.001). Cathodal tDCS increased pain relative to sham (Cohen's d = 0.34, P < 0.01). These effects remained stable throughout the 35-minute post-tDCS pain testing period, with no evidence of decay over time. Blinding assessments confirmed that participants were unable to reliably identify the sham session. Anodal tDCS also modestly increased reaction time in the left (ipsilateral) hand ( P < 0.05, Cohen's d = 0.16), consistent with interhemispheric inhibition, which was uncorrelated with analgesia ( P > 0.10). This study provides strong evidence for reliable and polarity-dependent modulation of experimental pain by M1-tDCS.
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (11) , 3134-3145
A Clinically Feasible Electrode Array for 3D Intraoperative Electrical Impedance Tomography-Based Surgical Margin Assessment in Robot-Assisted Radical Prostatectomy
Objective: A novel small form factor circular electrode array was designed specifically for electrical impedance tomography (EIT) based assessment of surgical margins during robot assisted radical prostatectomy (RARP). Methods: The electrode array consists of 33 gold-plated electrodes arranged within a 9.5 mm diameter circular footprint on the end of a surgical probe that can be introduced through a standard 12 mm laparoscopic port used during RARP. The electrode array contains 8 larger, low-contact impedance outer electrodes dedicated for current drive and an internal grid of 25 smaller electrodes for simultaneous voltage measurement. Separating electrode geometry by function is designed to improve current delivery, speed, and resolution while reducing hardware requirements. Results: Simulations demonstrated that 1 mm diameter hemispherical prostate cancer inclusions could be localized within regions of adipose and benign prostate tissue; 1.5 mm diameter inclusions were required for localization within muscle tissue. A 2.38 mm diameter aluminum rod in 0.2 S/m saline could be localized throughout the imaging domain with a position error of less than 2.5 mm for depths from the electrode array surface of up to 1.7 mm. Ex vivo tissue experiments with a bovine model demonstrate visual congruence of muscle and adipose tissue locations between the sample and reconstructed images. Conclusion: Simulation and experimental results indicate good detection and location of inclusions. Significance: These results suggest the proposed electrode array design can provide sufficient accuracy in the detection and localization of prostate cancer against clinically relevant background tissues for use during RARP.
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (11) , 3134-3145
A Clinically Feasible Electrode Array for 3D Intraoperative Electrical Impedance Tomography-Based Surgical Margin Assessment in Robot-Assisted Radical Prostatectomy
Objective: A novel small form factor circular electrode array was designed specifically for electrical impedance tomography (EIT) based assessment of surgical margins during robot assisted radical prostatectomy (RARP). Methods: The electrode array consists of 33 gold-plated electrodes arranged within a 9.5 mm diameter circular footprint on the end of a surgical probe that can be introduced through a standard 12 mm laparoscopic port used during RARP. The electrode array contains 8 larger, low-contact impedance outer electrodes dedicated for current drive and an internal grid of 25 smaller electrodes for simultaneous voltage measurement. Separating electrode geometry by function is designed to improve current delivery, speed, and resolution while reducing hardware requirements. Results: Simulations demonstrated that 1 mm diameter hemispherical prostate cancer inclusions could be localized within regions of adipose and benign prostate tissue; 1.5 mm diameter inclusions were required for localization within muscle tissue. A 2.38 mm diameter aluminum rod in 0.2 S/m saline could be localized throughout the imaging domain with a position error of less than 2.5 mm for depths from the electrode array surface of up to 1.7 mm. Ex vivo tissue experiments with a bovine model demonstrate visual congruence of muscle and adipose tissue locations between the sample and reconstructed images. Conclusion: Simulation and experimental results indicate good detection and location of inclusions. Significance: These results suggest the proposed electrode array design can provide sufficient accuracy in the detection and localization of prostate cancer against clinically relevant background tissues for use during RARP.
- 13 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (1) , 97-105
Development of an Electrical Impedance Tomography Coupled Surgical Stapler for Tissue Characterization
Objective: This study explores the feasibility of coupling Electrical Impedance Tomography (EIT) to a standard-of-care laparoscopic surgical stapler, stapler+EIT, with the long-term goal of enabling intraoperative tissue differentiation for tumor margin detection. Methods: Two custom printed-circuit-board-based electrode arrays with 60 and 8 electrodes, respectively, matching the stapler geometry, served as the jaws of an electrode-integrated surrogate stapler+EIT device. The device was evaluated through a series of simulations and bench-top imaging experiments of agar-gel phantoms and bovine tissue samples to evaluate the technique and determine optimal imaging parameters. Results: Electrodes localized to only one jaw (the 60-electrode side) of the stapler outperformed a dual-jaw distribution of electrodes. Using this one-sided electrode array, reconstructions achieved an Area-Under-the-Curve (AUC) ≥ 0.94 for inclusions with conductivity contrasts of ≥30% for any size considered on measured agar-gel tests, and an AUC of 0.80 for bovine tissue samples. Conclusion: A stapler+EIT algorithm has been tuned and evaluated on challenging phantom tests and demonstrated to produce accurate reconstructions. Significance: This work is an important step in the development of a surgical stapler+EIT technique for margin assessment.
- 13 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (1) , 97-105
Development of an Electrical Impedance Tomography Coupled Surgical Stapler for Tissue Characterization
Objective: This study explores the feasibility of coupling Electrical Impedance Tomography (EIT) to a standard-of-care laparoscopic surgical stapler, stapler+EIT, with the long-term goal of enabling intraoperative tissue differentiation for tumor margin detection. Methods: Two custom printed-circuit-board-based electrode arrays with 60 and 8 electrodes, respectively, matching the stapler geometry, served as the jaws of an electrode-integrated surrogate stapler+EIT device. The device was evaluated through a series of simulations and bench-top imaging experiments of agar-gel phantoms and bovine tissue samples to evaluate the technique and determine optimal imaging parameters. Results: Electrodes localized to only one jaw (the 60-electrode side) of the stapler outperformed a dual-jaw distribution of electrodes. Using this one-sided electrode array, reconstructions achieved an Area-Under-the-Curve (AUC) ≥ 0.94 for inclusions with conductivity contrasts of ≥30% for any size considered on measured agar-gel tests, and an AUC of 0.80 for bovine tissue samples. Conclusion: A stapler+EIT algorithm has been tuned and evaluated on challenging phantom tests and demonstrated to produce accurate reconstructions. Significance: This work is an important step in the development of a surgical stapler+EIT technique for margin assessment.
- 19 December 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (1) , 015007
Design of electrical impedance spectroscopy sensing surgical drill using computational modelling and experimental validation
Electrical Impedance Spectroscopy (EIS) sensing surgical instruments could provide valuable and real-time feedback to surgeons about hidden tissue boundaries, therefore reducing the risk of iatrogenic injuries. In this paper, we present an EIS sensing surgical drill as an example instrument and introduce a strategy to optimize the mono-polar electrode geometry using a finite element method (FEM)-based computational model and experimental validation. An empirical contact impedance model and an adaptive mesh refinement protocol were developed to accurately preserve the behaviour of sensing electrodes as they approach high impedance boundaries. Specifically, experiments with drill-bit, cylinder, and conical geometries suggested a 15%–35% increase in resistance as the sensing electrode approached a high impedance boundary. Simulations achieved a maximum mean experiment-to-simulation mismatch of +1.7% for the drill-bit and +/−11% range for other electrode geometries. The simulations preserved the increase in resistance behaviour near the high impedance boundary. This highly accurate simulation framework allows us a mechanism for optimizing sensor geometry without costly experimental evaluation.
- 19 December 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (1) , 015007
Design of electrical impedance spectroscopy sensing surgical drill using computational modelling and experimental validation
Electrical Impedance Spectroscopy (EIS) sensing surgical instruments could provide valuable and real-time feedback to surgeons about hidden tissue boundaries, therefore reducing the risk of iatrogenic injuries. In this paper, we present an EIS sensing surgical drill as an example instrument and introduce a strategy to optimize the mono-polar electrode geometry using a finite element method (FEM)-based computational model and experimental validation. An empirical contact impedance model and an adaptive mesh refinement protocol were developed to accurately preserve the behaviour of sensing electrodes as they approach high impedance boundaries. Specifically, experiments with drill-bit, cylinder, and conical geometries suggested a 15%–35% increase in resistance as the sensing electrode approached a high impedance boundary. Simulations achieved a maximum mean experiment-to-simulation mismatch of +1.7% for the drill-bit and +/−11% range for other electrode geometries. The simulations preserved the increase in resistance behaviour near the high impedance boundary. This highly accurate simulation framework allows us a mechanism for optimizing sensor geometry without costly experimental evaluation.
- 5 May 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (6) , 1079-1089
A particle filter approach to dynamic kidney pose estimation in robotic surgical exposure
Purpose Traditional soft tissue registration methods require direct intraoperative visualization of a significant portion of the target anatomy in order to produce acceptable surface alignment. Image guidance is therefore generally not available during the robotic exposure of structures like the kidneys which are not immediately visualized upon entry into the abdomen. This paper proposes guiding surgical exposure with an iterative state estimator that assimilates small visual cues into an a priori anatomical model as exposure progresses, thereby evolving pose estimates for the occluded structures of interest. Methods Intraoperative surface observations of a right kidney are simulated using endoscope tracking and preoperative tomography from a representative robotic partial nephrectomy case. Clinically relevant random perturbations of the true kidney pose are corrected using this sequence of observations in a particle filter framework to estimate an optimal similarity transform for fitting a patient-specific kidney model at each step. The temporal response of registration error is compared against that of serial rigid coherent point drift (CPD) in both static and simulated dynamic surgical fields, and for varying levels of observation persistence. Results In the static case, both particle filtering and persistent CPD achieved sub-5 mm accuracy, with CPD processing observations 75% faster. Particle filtering outperformed CPD in the dynamic case under equivalent computation times due to the former requiring only minimal persistence. Conclusion This proof-of-concept simulation study suggests that Bayesian state estimation may provide a viable pathway to image guidance for surgical exposure in the abdomen, especially in the presence of dynamic intraoperative tissue displacement and deformation.
- 5 May 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (6) , 1079-1089
A particle filter approach to dynamic kidney pose estimation in robotic surgical exposure
Purpose Traditional soft tissue registration methods require direct intraoperative visualization of a significant portion of the target anatomy in order to produce acceptable surface alignment. Image guidance is therefore generally not available during the robotic exposure of structures like the kidneys which are not immediately visualized upon entry into the abdomen. This paper proposes guiding surgical exposure with an iterative state estimator that assimilates small visual cues into an a priori anatomical model as exposure progresses, thereby evolving pose estimates for the occluded structures of interest. Methods Intraoperative surface observations of a right kidney are simulated using endoscope tracking and preoperative tomography from a representative robotic partial nephrectomy case. Clinically relevant random perturbations of the true kidney pose are corrected using this sequence of observations in a particle filter framework to estimate an optimal similarity transform for fitting a patient-specific kidney model at each step. The temporal response of registration error is compared against that of serial rigid coherent point drift (CPD) in both static and simulated dynamic surgical fields, and for varying levels of observation persistence. Results In the static case, both particle filtering and persistent CPD achieved sub-5 mm accuracy, with CPD processing observations 75% faster. Particle filtering outperformed CPD in the dynamic case under equivalent computation times due to the former requiring only minimal persistence. Conclusion This proof-of-concept simulation study suggests that Bayesian state estimation may provide a viable pathway to image guidance for surgical exposure in the abdomen, especially in the presence of dynamic intraoperative tissue displacement and deformation.
- Open Access
- 1 April 2021
- Published by AME Publishing Company in Health and Technology
- Vol. 5 (1) , 4
Usability assessment of a Bluetooth-enabled resistance exercise band among young adults
Background: Resistance-based exercises effectively enhance muscle strength, which is especially important in older populations as it reduces the risk of disability. Our group developed a Bluetooth-enabled handle for resistance exercise bands that wirelessly transmits relative force data through low-energy Bluetooth to a local smartphone or similar device. We present a usability assessment that evaluates an exercise system featuring a novel Bluetooth-enabled resistance exercise band, ultimately intended to expand the accessibility of resistance training through technology-enhanced home-based exercise programs for older adults. Although our target population is older adults, we assess the user experience among younger adults as a convenient and meaningful starting point in the testing and development of our device. Methods: There were 32 young adults participating in three exercise sessions with the exercise band, after which each completed an adapted version of the Usefulness, Satisfaction, and Ease (USE) questionnaire to characterize the exercise system’s strengths and weaknesses in usability. Results: Questionnaire data reflected a positive and consistent user experience, with all 20 items receiving mean scores greater than 5.0 on a seven-point Likert scale. There were no specific areas of significant weakness in the device’s user experience. Conclusions: The positive reception among young adults is a promising indication that the device can be successfully incorporated into exercise interventions and that the system can be further developed and tested for the target population of older adults.
- 1 April 2021
- Published by AME Publishing Company in Health and Technology
- Vol. 5 (1) , 4
Open AccessUsability assessment of a Bluetooth-enabled resistance exercise band among young adults
Background: Resistance-based exercises effectively enhance muscle strength, which is especially important in older populations as it reduces the risk of disability. Our group developed a Bluetooth-enabled handle for resistance exercise bands that wirelessly transmits relative force data through low-energy Bluetooth to a local smartphone or similar device. We present a usability assessment that evaluates an exercise system featuring a novel Bluetooth-enabled resistance exercise band, ultimately intended to expand the accessibility of resistance training through technology-enhanced home-based exercise programs for older adults. Although our target population is older adults, we assess the user experience among younger adults as a convenient and meaningful starting point in the testing and development of our device. Methods: There were 32 young adults participating in three exercise sessions with the exercise band, after which each completed an adapted version of the Usefulness, Satisfaction, and Ease (USE) questionnaire to characterize the exercise system’s strengths and weaknesses in usability. Results: Questionnaire data reflected a positive and consistent user experience, with all 20 items receiving mean scores greater than 5.0 on a seven-point Likert scale. There were no specific areas of significant weakness in the device’s user experience. Conclusions: The positive reception among young adults is a promising indication that the device can be successfully incorporated into exercise interventions and that the system can be further developed and tested for the target population of older adults.
- 11 December 2020
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 49 (1) , 652
1292: A Multivariate Machine Learning Algorithm for Occult Hemorrhage in a Porcine Model
- 11 December 2020
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 49 (1) , 652
1292: A Multivariate Machine Learning Algorithm for Occult Hemorrhage in a Porcine Model