Jing Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jing Zhou has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Jian Cai
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, China
3 shared publicationsGuobin Bu
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, China
2 shared publicationsHuiying Wang
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510641, China
2 shared publicationsXiaodan Fang
State Key Laboratory of Subtropical Building Science South China University of Technology Guangzhou China
2 shared publicationsChun Yang
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, China
1 shared publication- Hongtao Lai
Architectural Design and Research Institute of SCUT Co., Ltd., Guangzhou 510641, China
1 shared publication
Latest Publications
- Open Access
- 10 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (18) , 8422
A Novel Ring Spring Vibration Isolator for Metro Superstructure
Due to the serious impact of metro vibration on people’s lives, it is important to design vibration isolators. In this study, the dynamic characteristics of a thick-walled ring spring are studied first. Through theoretical derivation, a new formula suitable for thick-walled ring springs is proposed. Finite element numerical analysis was performed to study the load–displacement curve and stress of the ring spring and verified the correctness of the formula. According to the studied mechanic characteristics, a novel ring spring isolator is proposed for vibration isolation of the metro superstructure. With the help of a ring spring, the proposed isolator has good energy absorption and self-reset function. The dynamic simulations were conducted in a multi-story building with the ring spring isolator as the isolator to study the vibration performance. It is common knowledge that the vertical natural frequency of the superstructure that is isolated by compression springs is given by the mass of the superstructure and the spring stiffness. In order to obtain vibration attenuation and control the vertical deformation, the spring stiffness needs to be 500–1000 kN/mm. Hence, it is clear that the vibration isolator does reduce the vertical eigenfrequency. By comparing the isolated structure with the non-isolated structure, it is proved that the new isolator can effectively improve a building’s serviceability.
- 10 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (18) , 8422
Open AccessA Novel Ring Spring Vibration Isolator for Metro Superstructure
Due to the serious impact of metro vibration on people’s lives, it is important to design vibration isolators. In this study, the dynamic characteristics of a thick-walled ring spring are studied first. Through theoretical derivation, a new formula suitable for thick-walled ring springs is proposed. Finite element numerical analysis was performed to study the load–displacement curve and stress of the ring spring and verified the correctness of the formula. According to the studied mechanic characteristics, a novel ring spring isolator is proposed for vibration isolation of the metro superstructure. With the help of a ring spring, the proposed isolator has good energy absorption and self-reset function. The dynamic simulations were conducted in a multi-story building with the ring spring isolator as the isolator to study the vibration performance. It is common knowledge that the vertical natural frequency of the superstructure that is isolated by compression springs is given by the mass of the superstructure and the spring stiffness. In order to obtain vibration attenuation and control the vertical deformation, the spring stiffness needs to be 500–1000 kN/mm. Hence, it is clear that the vibration isolator does reduce the vertical eigenfrequency. By comparing the isolated structure with the non-isolated structure, it is proved that the new isolator can effectively improve a building’s serviceability.
- 20 May 2021
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 26 (13) , 6778-6802
Seismic Behaviour of PC-encased HCSC Composite Shear Walls under Vertical Tension and Horizontal Cyclic Loading
The integrity of precast concrete (PC) shear walls depends strongly on the structural measures and construction quality of the reinforcement connections, which impedes complete equivalence with cast-in-place connections, the construction height, and the applicability to high-seismicity regions. The seismic behaviour of hybrid precast concrete-encased concrete-filled twin steel tube (PCCS)-reinforced composite shear walls was investigated under combined vertical tension and horizontal cyclic loading. Embedded cast-in-place high-strength concrete-filled thin-walled twin steel tube cores (HCSCs) were used to position a PC shear wall panel and stiffen vertical connections for improved load-bearing. Quasi-static cyclic tests were conducted on six PCCS composite shear wall specimens with a shear-span ratio of 1.84 to investigate how the HCSC cross-section ratio, out-of-plane eccentricity, and initial axial tension affected the seismic performance. The specimens failed by combined shear-bending, and the HCSCs served as reliable connections and reinforcements. The specimens exhibited relatively high load-bearing capacities, complete hysteretic curves, good deformation and energy dissipation, and large residual stiffnesses at failure. Shear deformation contributed approximately 21% to the total lateral displacement. The average ultimate drift ratio of 1/42 and average ductility factor of 5.0 of the specimens demonstrated excellent assembly integrity. A parametric analysis of the bearing capacity of the cross-section revealed that as the HCSC cross-section ratio increased, both the shear capacity and lateral stiffness increased, where the latter produced a rapid decrease in the deformation curvature. The shear capacity decreased with increasing initial axial tension and out-of-plane eccentricity. The deformation curvature was increased using an appropriate axial tension level and deteriorated by the out-of-plane eccentricity.
- 20 May 2021
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 26 (13) , 6778-6802
Seismic Behaviour of PC-encased HCSC Composite Shear Walls under Vertical Tension and Horizontal Cyclic Loading
The integrity of precast concrete (PC) shear walls depends strongly on the structural measures and construction quality of the reinforcement connections, which impedes complete equivalence with cast-in-place connections, the construction height, and the applicability to high-seismicity regions. The seismic behaviour of hybrid precast concrete-encased concrete-filled twin steel tube (PCCS)-reinforced composite shear walls was investigated under combined vertical tension and horizontal cyclic loading. Embedded cast-in-place high-strength concrete-filled thin-walled twin steel tube cores (HCSCs) were used to position a PC shear wall panel and stiffen vertical connections for improved load-bearing. Quasi-static cyclic tests were conducted on six PCCS composite shear wall specimens with a shear-span ratio of 1.84 to investigate how the HCSC cross-section ratio, out-of-plane eccentricity, and initial axial tension affected the seismic performance. The specimens failed by combined shear-bending, and the HCSCs served as reliable connections and reinforcements. The specimens exhibited relatively high load-bearing capacities, complete hysteretic curves, good deformation and energy dissipation, and large residual stiffnesses at failure. Shear deformation contributed approximately 21% to the total lateral displacement. The average ultimate drift ratio of 1/42 and average ductility factor of 5.0 of the specimens demonstrated excellent assembly integrity. A parametric analysis of the bearing capacity of the cross-section revealed that as the HCSC cross-section ratio increased, both the shear capacity and lateral stiffness increased, where the latter produced a rapid decrease in the deformation curvature. The shear capacity decreased with increasing initial axial tension and out-of-plane eccentricity. The deformation curvature was increased using an appropriate axial tension level and deteriorated by the out-of-plane eccentricity.
- 9 August 2020
- Published by Wiley in Structural Concrete
- Vol. 22 (2) , 691-708
Cyclic behavior of concrete‐encased high‐strength concrete‐filled steel tube composite walls: An experiment
Concrete‐encased high‐strength concrete‐filled steel tube (CFST) walls are a new type of composite shear wall embedded into high‐strength CFST columns as a boundary element and/or in the centre of a wall. To examine the cyclic behavior of the concrete‐encased CFST composite wall, ten wall specimens were designed, and tested under lateral cyclic loading. The performance parameters of each specimen, including the failure pattern, hysteresis characteristics, load‐bearing capacity, ductility, stiffness, and energy dissipation capacity were studied. The experimental results demonstrated that the concrete‐encased CFST walls have a high initial stiffness and load‐bearing capacity. The degradation of the load‐bearing capacity and stiffness is slow, the ductility of the composite wall is excellent, and the hysteresis curve of the wall is complete under cyclic loading, which indicates a good cyclic behavior. The specimens maintain a good ductility and energy dissipation capacity, even at a high axial compression ratio. The CFST columns embedded in the centre of a wall enhance the load‐bearing capacity and change the distribution and propagation direction of cracks.
- 9 August 2020
- Published by Wiley in Structural Concrete
- Vol. 22 (2) , 691-708
Cyclic behavior of concrete‐encased high‐strength concrete‐filled steel tube composite walls: An experiment
Concrete‐encased high‐strength concrete‐filled steel tube (CFST) walls are a new type of composite shear wall embedded into high‐strength CFST columns as a boundary element and/or in the centre of a wall. To examine the cyclic behavior of the concrete‐encased CFST composite wall, ten wall specimens were designed, and tested under lateral cyclic loading. The performance parameters of each specimen, including the failure pattern, hysteresis characteristics, load‐bearing capacity, ductility, stiffness, and energy dissipation capacity were studied. The experimental results demonstrated that the concrete‐encased CFST walls have a high initial stiffness and load‐bearing capacity. The degradation of the load‐bearing capacity and stiffness is slow, the ductility of the composite wall is excellent, and the hysteresis curve of the wall is complete under cyclic loading, which indicates a good cyclic behavior. The specimens maintain a good ductility and energy dissipation capacity, even at a high axial compression ratio. The CFST columns embedded in the centre of a wall enhance the load‐bearing capacity and change the distribution and propagation direction of cracks.
- 14 August 2015
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 20 (1) , 12-38
Modification of Ductility Reduction Factor for Strength Eccentric Structures Subjected to Pulse-Like Ground Motions
This article investigates the ductility reduction factors for RC eccentric frame structures subjected to pulse-like ground motions. The structural models are with the strength eccentricities which are much disadvantageous than the stiffness eccentricities during the inelastic response range. A method to determine the ductility reduction factors of the strength eccentric structures is suggested by modifying those of reference symmetric structures through an eccentricity modification factor. The four factors of strength eccentricity ratio, ductility ratio, story number and velocity pulse of ground motions, are investigated to gain insight into this modification factor. It shows that the ductility reduction factors of the eccentric structures are clearly smaller than those of the symmetric structures. The eccentricity modification factor is mainly affected by the strength eccentricity and the ductility ratio, decreasing with the increment of the eccentricity or the decrement of the ductility ratio in a medium eccentricity range. The earthquake pulse-like effect and the eccentricity have coupling influence on the modification factor, while the effect of story number is not apparent. Based on the results of a comprehensive statistical study a simplified expression is suggested, which can estimate the eccentricity modification factors for both pulse-like and nonpulse-like ground motion cases.
- 14 August 2015
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 20 (1) , 12-38
Modification of Ductility Reduction Factor for Strength Eccentric Structures Subjected to Pulse-Like Ground Motions
This article investigates the ductility reduction factors for RC eccentric frame structures subjected to pulse-like ground motions. The structural models are with the strength eccentricities which are much disadvantageous than the stiffness eccentricities during the inelastic response range. A method to determine the ductility reduction factors of the strength eccentric structures is suggested by modifying those of reference symmetric structures through an eccentricity modification factor. The four factors of strength eccentricity ratio, ductility ratio, story number and velocity pulse of ground motions, are investigated to gain insight into this modification factor. It shows that the ductility reduction factors of the eccentric structures are clearly smaller than those of the symmetric structures. The eccentricity modification factor is mainly affected by the strength eccentricity and the ductility ratio, decreasing with the increment of the eccentricity or the decrement of the ductility ratio in a medium eccentricity range. The earthquake pulse-like effect and the eccentricity have coupling influence on the modification factor, while the effect of story number is not apparent. Based on the results of a comprehensive statistical study a simplified expression is suggested, which can estimate the eccentricity modification factors for both pulse-like and nonpulse-like ground motion cases.
- 26 June 2015
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 19 (7) , 1158-1180
Least Favorable Probability of Failure for 5- and 10-story RC Frame Structures with Vertical Irregularities
- 26 June 2015
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 19 (7) , 1158-1180
Least Favorable Probability of Failure for 5- and 10-story RC Frame Structures with Vertical Irregularities
- 1 April 2014
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 18 (5) , 816-830
Influence of Ground Motion Duration on Damping Reduction Factor
This article investigates the influences of the effective ground motion duration (GMD) on damping reduction factor. The GMD are associated with 25 Chi-chi earthquake ground motion records and harmonic sine wave. The study shows that damping reduction factor decreases with the increasing of the damping ratio, and decreases with the increasing of the effective duration of the ground motion and the number of cycles of harmonic excitation. A nonlinear multiple regression analysis based on the statistical mean values of the present study is employed, and a modified damping reduction factor considering the effects of GMD is suggested.
- 1 April 2014
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 18 (5) , 816-830
Influence of Ground Motion Duration on Damping Reduction Factor
This article investigates the influences of the effective ground motion duration (GMD) on damping reduction factor. The GMD are associated with 25 Chi-chi earthquake ground motion records and harmonic sine wave. The study shows that damping reduction factor decreases with the increasing of the damping ratio, and decreases with the increasing of the effective duration of the ground motion and the number of cycles of harmonic excitation. A nonlinear multiple regression analysis based on the statistical mean values of the present study is employed, and a modified damping reduction factor considering the effects of GMD is suggested.
- 1 April 2013
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 16 (4) , 641-652
Modification of Ductility Reduction Factor for Vertically Irregular Structures Subjected to Pulse-Like Ground Motions
This paper reports on investigations into seismic ductility reduction factors for vertically irregular multi-degree-of-freedom (MDOF) systems subjected to pulse-like ground motions. Ductility reduction factors of irregular MDOF systems are obtained by modifying those of reference regular MDOF systems through a modification factor. Specifically, the structural vertical irregularities are introduced by changing the combined-strength-and-stiffness at the first storey of a reference regular system. The five main parameters of irregularity ratio, ductility ratio, fundamental period, storey number and velocity pulse of ground motions, have been investigated to gain insight into the modification factors. It is demonstrated that ductility reduction factors for irregular MDOF systems are clearly smaller than those for regular MDOF systems. The modification factor is mainly affected by irregularity ratio, and ductility ratio, decreasing with decreasing irregularity ratio and increasing ductility ratio. However, the storey number and fundamental period are observed to have little influence on this modification. Finally, based on the statistical results of pulse-like and non-pulse-like cases, reference values of the modification factors are suggested, which can somehow accounts for the effects of vertical irregularity and velocity pulse on ductility reduction factor in engineering application.
- 1 April 2013
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 16 (4) , 641-652
Modification of Ductility Reduction Factor for Vertically Irregular Structures Subjected to Pulse-Like Ground Motions
This paper reports on investigations into seismic ductility reduction factors for vertically irregular multi-degree-of-freedom (MDOF) systems subjected to pulse-like ground motions. Ductility reduction factors of irregular MDOF systems are obtained by modifying those of reference regular MDOF systems through a modification factor. Specifically, the structural vertical irregularities are introduced by changing the combined-strength-and-stiffness at the first storey of a reference regular system. The five main parameters of irregularity ratio, ductility ratio, fundamental period, storey number and velocity pulse of ground motions, have been investigated to gain insight into the modification factors. It is demonstrated that ductility reduction factors for irregular MDOF systems are clearly smaller than those for regular MDOF systems. The modification factor is mainly affected by irregularity ratio, and ductility ratio, decreasing with decreasing irregularity ratio and increasing ductility ratio. However, the storey number and fundamental period are observed to have little influence on this modification. Finally, based on the statistical results of pulse-like and non-pulse-like cases, reference values of the modification factors are suggested, which can somehow accounts for the effects of vertical irregularity and velocity pulse on ductility reduction factor in engineering application.
- 1 October 2006
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 9 (5) , 591-601
Seismic Ductility Reduction Factors for Multi-Degree-of-Freedom Systems
This paper reports on investigations into seismic ductility reduction factors for MDOF systems. Ductility reduction factors for MDOF systems are obtained by modifying ductility reduction factors of SDOF systems through a modification factor. Based on China's seismic code, MDOF lumped-mass shear-type models are introduced and employed to study the modification factors that can be used to calculate the lateral strength demand of MDOF systems. The four main parameters of site characteristics, number of storeys, displacement ductility ratio and fundamental period of the system, have been investigated to gain insight into the modification factors. It is demonstrated that ductility reduction factors for MDOF systems are clearly smaller than those for SDOF systems. The modification factor is mainly affected by the number of storeys, and the fundamental period. The ductility ratio also has an important influence on the modification factor and can't be neglected. Analysis results also indicate that the coefficient of variation for the modification factor increases with increasing number of storeys, fundamental period and ductility ratio. Finally, based on the results of a comprehensive statistical study on modification factors a simplified expression is suggested, which can conservatively estimate the modification factor required.
- 1 October 2006
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 9 (5) , 591-601
Seismic Ductility Reduction Factors for Multi-Degree-of-Freedom Systems
This paper reports on investigations into seismic ductility reduction factors for MDOF systems. Ductility reduction factors for MDOF systems are obtained by modifying ductility reduction factors of SDOF systems through a modification factor. Based on China's seismic code, MDOF lumped-mass shear-type models are introduced and employed to study the modification factors that can be used to calculate the lateral strength demand of MDOF systems. The four main parameters of site characteristics, number of storeys, displacement ductility ratio and fundamental period of the system, have been investigated to gain insight into the modification factors. It is demonstrated that ductility reduction factors for MDOF systems are clearly smaller than those for SDOF systems. The modification factor is mainly affected by the number of storeys, and the fundamental period. The ductility ratio also has an important influence on the modification factor and can't be neglected. Analysis results also indicate that the coefficient of variation for the modification factor increases with increasing number of storeys, fundamental period and ductility ratio. Finally, based on the results of a comprehensive statistical study on modification factors a simplified expression is suggested, which can conservatively estimate the modification factor required.