EREliane Cristina Pires Do Rego

Eliane Cristina Pires Do Rego

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eliane Cristina Pires Do Rego has a total of 167 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility study for the production of a lactose-free certified reference material in powder milk

    by Raissa Bosich Antunes Jambo, Rodrigo Vivarelli Poggi Leal, Eliane Cristina Pires Do Rego, Vanderléa de Souza

    Certified reference materials (CRMs) are essential for ensuring high-quality measurements and guaranteeing their metrological traceability to the International System of Units (SI). Reliable analytical results are indispensable for consumer protection. In this context, this work conducted a feasibility study of a candidate certified reference material for lactose-free powdered milk. A small-scale batch was produced and subjected to studies of homogeneity, transportation stability, and characterization according to ISO 17034 and ISO 33405. This batch was considered sufficiently homogeneous and could be transported for up to 40 days at a temperature of up to (22 ± 2) °C without compromising the values of lactose and water content, and with no changes in its appearance. The informative value for the mass fraction of lactose was (1.06 ± 0.193) mg/g ( k = 2, 95%) for the powdered milk on a wet basis. Since the produced batch was sufficiently homogeneous and stable under the proposed transport conditions, the production of the lactose-free powdered milk CRM was considered initially feasible.

  • Strategic Innovation for Drug Enforcement: Brazilian Development of Certified Reference Material for Amphetamine Hydrochloride

    by Marília S. Souza, Rodrigo G. Agostinho, Mariana dos S. Dupim, Rodrigo O. M. A. de Souza, Karen C. C. Machado, Wagner Wollinger, Eliane C. P. Do Rego, Fernanda G. Finelli

    This study addresses a critical national gap in Brazil regarding the production of certified reference materials (CRMs) for amphetamines, which are essential for ensuring the accuracy, comparability, and metrological traceability of forensic drug analyses. The work presents the synthesis of high-purity amphetamine hydrochloride on a gram scale and its full certification as a CRM. The synthetic route comprises three steps, including oxidation, reductive amination, and an acid-base reaction. The certification process involves comprehensive studies of identity, homogeneity, stability under varying conditions, and full characterization. The initiative was carried out in partnership with the University, Institute of Metrology, Quality and Technology (Inmetro), and the Brazilian Federal Police, aiming to meet the practical demands of forensic laboratories. Additionally, it contributes to building national capacity for CRM production, reducing reliance on imports, and promoting scientific autonomy. This work represents a step toward improving the quality infrastructure in forensic science in Brazil.

  • Key comparison CCQM-K78.b - non-polar analytes in organic solvent: methoxychlor and trifluralin in acetonitrile

    by S Westwood, R D Josephs, T Choteau, G Martos, R Wielgosz, Y Acho Sarzuri, E Mendoza, E C Pires Do Rego, F G Marques Violante, W da Silva Souza, et al.

    Main text: The CCQM-K78.b key comparison was coordinated by the Bureau International des Poids et Mesures (BIPM) on behalf of the CCQM Organic Analysis Working Group (OAWG) of the 'Comité Consultatif pour la Quantité de Matière' (CCQM), for National Measurement Institutes (NMIs) and Designated Institutes (DIs) providing measurement services in organic analysis under the 'Comité International des Poids et Mesures' (CIPM) Mutual Recognition Arrangement (MRA). This key comparison was conducted as a 'Track A' comparison within the OAWG's 10-year strategic plan. The goal of CCQM-K78.b was to underpin capabilities for the value assignment of calibration solutions containing low polarity/non-polar organic analytes in organic solvents. The selected model system consisted of a two-component pesticide solution in acetonitrile, comprising methoxychlor and trifluralin. Participants were tasked with assigning the mass fractions, in units of μg/g, of methoxychlor and trifluralin in acetonitrile solution. The mass fraction levels and analytical challenges of the selected analytes were representative of those encountered for calibration solutions of non-polar organic analytes. Participation in CCQM-K78.b allowed for the benchmarking of capabilities for assigning the mass fraction of non-polar organic compounds (pKow < -2) in solution, at mass fractions above 5 μg/g, in an organic solvent. Additionally, the comparison assessed the capabilities for the quantitative assignment of thermally labile compounds. Participants were provided by the BIPM with ampoules containing methoxychlor and trifluralin in acetonitrile. Each participant reported the mass fraction content of each analyte in μg/g. All participants ensured the metrological traceability of their results through the use of a Primary Reference Material (PRM), which was used to prepare a primary calibrator solution for each analyte using a gravimetric procedure. The twenty participating institutes primarily used analysis procedures based on GC-MS, -IDMS, -MS/MS, -ECD, and -FID, with some participants also using LC-UV for the value assignment. The analysis of methoxychlor and trifluralin in acetonitrile solution presented several challenges, including the thermal stability of the analytes under selected analytical techniques, control of solvent volatility, and considerable variation in some results using MS-based quantification methods. The mass fraction assignments for methoxychlor and trifluralin, consistent with the key comparison reference values (KCRVs), were achieved with associated relative standard uncertainties of (0.38 - 2.9) % for methoxychlor and (0.35 - 2.5) % for trifluralin. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • CCQM-K159 free amino acids in plasma

    by Emily Whyte, Tabatha Hambidge, Steve Ellison, Simon Cowen, Christopher Hopley, Mark Lewin, Tomoya Kinumi, Quinde Liu, Hong Liu, Cheng Yang Ng, et al.

    Main text: Inherited metabolic disorders affect approximately 1 in 1000 babies; amino acid disorders are less frequent, at approximately 1 in 6000. Babies diagnosed with amino acid disorders require constant monitoring of amino acid blood concentration, especially for disease states such as phenylketonuria. In addition, amino acid measurement may aid in the evaluation of several other disorders such as neurological and nutritional disorders. Free amino acids in healthy patients are typically in the low mg/kg range but, for example, elevated phenylalanine indicates phenylketonuria disease state. Evidence of successful participation in formal, relevant international comparisons is needed to document calibration and measurement capability claims (CMCs) made by national metrology institutes (NMIs) and designated institutes (DIs). This Track A study is being used to assess the core competencies of the National Metrology Institutes/Designated Institutes (NMIs/DIs) for provision of measurement services. The aim of this study is to assess the performance of the NMIs/DIs for a matrix material for clinical analytes. This follows and builds on the successful CCQM-K109 study on urea and uric acid in human serum. Eleven NMIs participated in the Track A Key Comparison CCQM-K159 Free amino acids in plasma. NMIs/DIs were given the option of taking part in a parallel pilot study CCQM-P202, however all participants opted for the Track A key comparison and there were no participants for CCQM-P202. Participants were requested to evaluate the mass fractions, expressed in mg/kg, of DL-phenylalanine and DL-leucine in pooled frozen human plasma with lithium heparin added as an anticoagulant. Successful participation in CCQM-K159 demonstrates the following measurement capabilities in determining mass fraction of organic compounds, with molecular mass of 50 g/mol to 500 g/mol, having high to mid polarity pKow > -4, in mass fraction range from 1 mg/kg to 1000 mg/kg in a biological matrix such as human plasma, serum and urine. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  • Independent certification of a suite of qNMR internal standards: ensuring metrological traceability in a wide range of applications

    by Wagner Wollinger, Jane Luiza Nogueira Fernandes, Eliane Cristina Pires Do Rego, Francisco Radler de Aquino Neto, Bruno Carius Garrido

    The Brazilian National Metrology Institute produced a suite of certified reference materials (CRMs) intended as internal standards (ISs) for quantitative nuclear magnetic resonance (qNMR). Being a ratio primary method, the use of qNMR in organic chemistry has already crossed the borders of research laboratories, despite the cost of instrumentation. The International Bureau of Weights and Measures (BIPM) proposed eight potential qNMR ISs. Four candidate materials were selected for their solubility in various solvents and distinct chemical shifts, making them suitable for qNMR analysis of diverse analytes. The certification process compared orthogonal primary methods such as mass balance, qNMR, freezing-point depression, and coulometry, to ensure independent value assignment. Different approaches were compared to assess batch homogeneity and stability. While directly comparing the main compound’s chromatographic area proved to be a quick and fit-for-purpose approach, the determination of individual impurities provided lower uncertainties but required more laborious work. CRM batches of maleic acid, dimethyl sulfone, potassium hydrogen phthalate, and dimethyl terephthalate were delivered with over 999.8 mg g−1 purity and uncertainty in the range of 0.6 to 3 mg g−1 (k = 2). The literature shows certification procedures for qNMR ISs whose traceability chain is exclusively based on qNMR measurements. As opposed to that, the methodology presented here provides robust certified values assigned by methods independent of qNMR, in accordance with BIPM recommendations and less prone to qNMR biases. The CRMs developed in this work have already been used for SI-traceable purity evaluation of compounds such as drugs and pesticides, by laboratories in Brazil and abroad. Graphical Abstract


  • Final report for CCQM-P212: coherence of carbon isotope delta reference materials

    by Michelle M G Chartrand, Fong-Ha Liu, Jeffrey P Merrick, Maíra Fasciotti, Bruno Carius Garrido, Eliane Cristina Pires Do Rego, Thays Vieira da Costa Monteiro, Wagner Wollinger, Heiko Moossen, Heike Geilmann, et al.

    Main text: This pilot study evaluates the coherence of carbon isotope delta reference materials (RMs) used by laboratories worldwide. The goal was to assess how well laboratories can realize the VPDB scale using these RMs. In total, carbon isotope delta values of 36 RMs were measured by seven laboratories as well as the vanillin sample previously evaluated in CCQM-K167/P211. A hierarchical Bayesian measurement model was used to evaluate the coherence between these RMs, and to determine the carbon isotope delta value of each of these RMs. In general, this study shows that the 36 carbon isotope delta RMs are reliable. Further, the value assigned to the vanillin sample in this study is within 0.02 ‰ from the CCQM-K167 KCRV. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Key Comparison Study - Organic Solvent Calibration Solution - Gravimetric preparation and value assignment of patulin (PAT) in acetonitrile (ACN) with 0.1 % formic acid (FA)

    by R D Josephs, M Bedu, A Daireaux, Xianjiang Li, Z Guo, Xiuqin Li, Q Zhang, Y Gao, T Choteau, G Martos, et al.

    Main text: The CCQM-K154.d comparison was coordinated by the the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM) on behalf of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) for National Measurement Institutes (NMIs) and Designated Institutes (DIs) which provide measurement services in organic analysis under the 'Comité International des Poids et Mesures' Mutual Recognition Arrangement (CIPM MRA) and/or have participated in the BIPM's Mycotoxin Metrology Capacity Building and Knowledge Transfer (MMCBKT) project as part of its "Metrology for Safe Food and Feed in Developing Economies" Capacity Building Programme. Gravimetrically-prepared solutions having an assigned mass fraction of specified organic analytes are routinely used to calibrate measurement processes for the quantification of the same analytes in matrix samples. Appropriate assignments of the property value and associated uncertainty of calibration solutions thus underpin the traceability of routine analysis and are critical for accurate measurements. Evidence of successful participation in relevant international comparisons is needed to document calibration and measurement capability claims (CMCs) made by national metrology institutes and designated institutes. In total, twelve NMIs/DIs participated in the Track C, Model II, Key Comparison CCQM-K154.d [Gravimetric preparation and value assignment of patulin (PAT) in acetonitrile (ACN) with 0.1 % formic acid (FA)] for emerging areas of global interest and innovation. Participants were requested to gravimetrically prepare calibration solutions and value assign the mass fractions, expressed in mg/kg, of PAT in ACN with 0.1 % FA solution. Study samples, with assigned values and associated uncertainties were prepared by the comparison participants and sent to the coordinating laboratory for comparison. The Key Comparison Reference Values (KCRVs), calculated form values measured by the coordinating laboratory based on calibrations obtained from independent gravimetrically prepared calibrant solutions, agreed with participants reported values, within their stated uncertainties. PAT is a mycotoxin produced by a variety of moulds, particularly by fungi of the genus Aspergillus and Penicillium. Often found in rotting apples and apple products, PAT can also occur in various other moldy fruits, grains and foods. Major human dietary sources of PAT are apples and apple juice made from affected fruit. PAT is relatively stable when given a short-acting heat-treatment, especially in an acidic environment. It was anticipated to provide a challenge representative for the gravimetrical preparation and value assignment of PAT calibration solutions in the mass fraction range of 10 mg/kg to 100 mg/kg of mycotoxins with broadly similar structural characteristics. Eight participants of the MMCBKT programme were provided with a stock solution having a known PAT mass fraction and expanded uncertainty to use to gravimetrically prepare and value assign a calibration solution. Two NMIs/DIs used reference materials for preparing their solutions while five NMIs/DIs participated using their own calibration solutions. The use of in-house solutions required an additional capacity to undertake a fit-for-purpose purity assessment. NIM was the only NMI participating using both the MMCBKT based and their own in-house assigned solutions in order to connect the two different groups. It was decided to propose separate KCRVs for each of the two ampoules provided by the participating NMIs/DIs based on the PAT mass fraction. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to gravimetrically prepare calibration solutions and to assess the PAT mass fraction. The majority of the PAT mass fraction KCRVs (wKCRV) for CCQM-K154.d spanned a mass fraction range of 9.72 mg/kg to 63.40 mg/kg. The relative expanded uncertainties U(wKCRV) ranged from 2.0 % to 5.4 %. Inspection of the degree of equivalence plots for the PAT mass fraction assignments in CCQM-K154.d indicated that there was an excellent agreement of results. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Key comparison study - organic solvent calibration solution - gravimetric preparation and value assignment of deoxynivalenol (DON) in acetonitrile (ACN)

    by R D Josephs, M Bedu, A Daireaux, Z Guo, Xianjiang Li, Y Gao, Xiuqin Li, T Choteau, G Martos, S Westwood, et al.

    Main text: The CCQM-K154.c comparison was coordinated by the the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM) on behalf of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) for National Measurement Institutes (NMIs) and Designated Institutes (DIs) which provide measurement services in organic analysis under the 'Comité International des Poids et Mesures' Mutual Recognition Arrangement (CIPM MRA) and/or have participated in the BIPM's Mycotoxin Metrology Capacity Building and Knowledge Transfer (MMCBKT) project as part of its "Metrology for Safe Food and Feed in Developing Economies" Capacity Building Programme. Gravimetrically-prepared solutions having an assigned mass fraction of specified organic analytes are routinely used to calibrate measurement processes for the quantification of the same analytes in matrix samples. Appropriate assignments of the property value and associated uncertainty of calibration solutions thus underpin the traceability of routine analysis and are critical for accurate measurements. Evidence of successful participation in relevant international comparisons is needed to document calibration and measurement capability claims (CMCs) made by national metrology institutes and designated institutes. In total, nine NMIs/DIs participated in the Track C, Model II, Key Comparison CCQM-K154.c [Gravimetric preparation and value assignment of deoxynivalenol (DON) in acetonitrile (ACN)] for emerging areas of global interest and innovation. Participants were requested to gravimetrically prepare calibration solutions and value assign the mass fractions, expressed in mg/kg, of deoxynivalenol (DON) in the acetonitrile (ACN) solution. Study samples, with assigned values and associated uncertainties were prepared by the comparison participants and sent to the coordinating laboratory for comparison. The Key Comparison Reference Values (KCRVs), calculated from values measured by the coordinating laboratory based on calibrations obtained from independent gravimetrically prepared calibrant solutions, agreed with participants reported values, within their stated uncertainties. DON belongs to the large group of trichothecene mycotoxins. It is produced by certain fungi of the genus Fusarium that predominantly infect wheat, corn, oats, barley, rice, and other grains in the field or during storage. It was anticipated to provide a challenge representative for the gravimetrical preparation and value assignment of calibration solutions in the mass fraction range of 10 mg/kg to 100 mg/kg of mycotoxins with broadly similar structural characteristics. Ten participants of the MMCBKT programme were provided with a stock solution having a known DON mass fraction and expanded uncertainty to use to gravimetrically prepare and value assign a calibration solution. Three NMIs/DIs also participated using their own calibration solutions. The use of in-house solutions required an additional capacity to undertake a fit-for-purpose purity assessment. NIM was the only NMI participating using both the MMCBKT based and their own in-house assigned solutions in order to connect the two different groups. It was decided to propose separate KCRVs for each of the two ampoules provided by the participating NMIs/DIs based on the DON mass fraction. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to gravimetrically prepare calibration solutions and to assess the DON mass fraction. The majority of the DON mass fraction KCRVs (w KCRV ) for CCQM-K154.c spanned a mass fraction range of 9.88 mg/kg to 123.45 mg/kg. The relative expanded uncertainties U(w KCRV ) ranged from 2.8 % to 6.8 %. Inspection of the degree of equivalence plots for the DON mass fraction assignments in CCQM-K154.c indicated that there was an excellent agreement of results. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Final report on CCQM-K167: carbon isotope delta measurements of vanillin

    by Michelle M G Chartrand, Ian Chubchenko, Philip J H Dunn, Bruno Carius Garrido, Lu Hai, Fong-Ha Liu, Nives Ogrinc, Adnan Simsek, Maíra Fasciotti, Heidi Goenaga-Infante, et al.

    Main text: The CCQM Isotope Ratio Working Group (IRWG) determined that an additional key comparison of carbon isotope delta measurements was required to capture the progress of this field. Vials containing 0.25 mg of vanillin were prepared at NRC, and evaluated for bottle-to-bottle homogeneity prior to distribution to the eight participating institutes. Participants were able to choose any suitable method and reference materials for carbon isotope delta measurements, and report a carbon isotope delta value and the associated uncertainty, and analysis details. To determine the key comparison reference value (KCRV) and its associated uncertainty, the NRC in collaboration with the NIST, developed a multivariate Bayesian random laboratory effects model, which also incorporates the uncertainty due to bottle-to-bottle homogeneity and any correlations between the reported results that arise due to the use of common reference materials. The KCRV for this study was determined to be -25.833 ‰ relative to the VPDB, with associated uncertainty of 0.028 ‰, and expanded uncertainty of 0.056 ‰ (k=2). All the results reported by the participants in this study were considered equivalent to the KCRV. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Key Comparison Study - Organic Solvent Calibration Solution - Gravimetric preparation and value assignment of aflatoxin B1 (AfB1) in acetonitrile (ACN)

    by R D Josephs, M Bedu, A Daireaux, Xiuqin Li, Xiaomin Li, Z Guo, Xianjiang Li, T Choteau, G Martos, S Westwood, et al.

    Main text: The CCQM-K154.b comparison was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM) on behalf of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) for National Measurement Institutes (NMIs) and Designated Institutes (DIs) which provide measurement services in organic analysis under the 'Comité International des Poids et Mesures' Mutual Recognition Arrangement (CIPM MRA) and/or have participated in the BIPM's Mycotoxin Metrology Capacity Building and Knowledge Transfer (MMCBKT) project as part of its "Metrology for Safe Food and Feed in Developing Economies" Capacity Building Programme. Gravimetrically-prepared solutions having an assigned mass fraction of specified organic analytes are routinely used to calibrate measurement processes for the quantification of the same analytes in matrix samples. Appropriate assignments of the property value and associated uncertainty of calibration solutions thus underpin the traceability of routine analysis and are critical for accurate measurements. Evidence of successful participation in relevant international comparisons is needed to document calibration and measurement capability claims (CMCs) made by national metrology institutes and designated institutes. In total, eleven NMIs/DIs participated in the Track C, Model II, Key Comparison CCQM-K154.b [Gravimetric preparation and value assignment of aflatoxin B1 (AfB1) in acetonitrile (ACN)] for emerging areas of global interest and innovation. Participants were requested to gravimetrically prepare calibration solutions and value assign the mass fractions, expressed in mg/kg, of aflatoxin B1 (AfB1) in the acetonitrile (ACN) solution. Study samples, with assigned values and associated uncertainties were prepared by the comparison participants and sent to the coordinating laboratory for comparison. The Key Comparison Reference Values (KCRVs), calculated form values measured by the coordinating laboratory based on calibrations obtained from independent gravimetrically prepared calibrant solutions, agreed with participants reported values, within their stated uncertainties. AfB1 was selected to be representative of polar aflatoxins. Aflatoxins are a class of mycotoxins generally produced by fungi of the genus Aspergillus. It was anticipated to provide a challenge representative for the gravimetrical preparation and value assignment of calibration solutions in the mass fraction range of 2 mg/kg to 50 mg/kg of mycotoxins with broadly similar structural characteristics. Nine participants of the MMCBKT programme were provided with a stock solution having a known AfB1 mass fraction and expanded uncertainty to use to gravimetrically prepare and value assign a calibration solution. Three NMIs/DIs also participated using their own calibration solutions. The use of in-house solutions required an additional capacity to undertake a fit-for-purpose purity assessment. NIM was the only NMI participating using both the MMCBKT based and their own in-house assigned solutions in order to connect the two different groups. It was decided to propose separate KCRVs for each of the two ampoules provided by the participating NMIs/DIs based on the AfB1 mass fraction. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to gravimetrically prepare calibration solutions and to assess the AfB1 mass fraction. The majority of the AfB1 mass fraction KCRVs (wKCRV) for CCQM-K154.b spanned a mass fraction range of 2.02 mg/kg to 31.57 mg/kg. The relative expanded uncertainties U(wKCRV) ranged from 0.69 % to 2.93 %. Inspection of the degree of equivalence plots for the AfB1 mass fraction assignments in CCQM-K154.b indicated that there was an excellent agreement of results. Solely, the AfB1 mass fraction assignments of INRAP did not agree with the KCRVs. It was found that the samples were altered as a result of an acid contamination. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).