Guohong Chai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guohong Chai has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Xiangyang Zhu
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
7 shared publications - Xinjun Sheng
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Meta Robotics Institute, Shanghai Jiao Tong University, Shanghai, China
6 shared publications - Guoying Gu
State Key Laboratory of Mechanical System and Vibration, Robotics Institute, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publications Haipeng Xu
Robotics Institute, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
3 shared publications- Jianjun Meng
Shanghai Jiao Tong University
3 shared publications - Shiyong Su
Cognition and Actions Lab, Institute of Neuroscience, UCLouvain, Brussels, Belgium
3 shared publications
Latest Publications
- Open Access
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 674-685
Discrete Tactile Feedback Based on Weber’s Law Enhances Prosthetic Hand Approaching Performance Under Divided Visual Attention
In multiple vision-demanding tasks, accurately controlling a prosthetic hand to approach a target object is particularly challenging for amputees, as visual attention diverted by other tasks forces them to rely heavily on peripheral vision. This study aims to initially validate that functionally effective sensory feedback can enhance the control of prosthetic hands during object approach under divided visual attention. To quantify prosthesis users' ability to approach and manipulate objects using central and peripheral vision in real-life scenarios, we conducted two experimental tasks—APPROACHING and PINCH—under two visual feedback modes: full-vision and partial-vision. During the approaching process, we compared four feedback conditions: no supplementary sensory feedback (PURE), traditional continuous feedback (CONT), evenly distributed discrete feedback (ADIS), and a novel discrete strategy based on Weber's law (WDIS) proposed in this study. Task performance was evaluated using metrics such as position error, dispersion, task completion time, and pinch failures, while psychological factors were assessed through a questionnaire. Results show that WDIS enabled more accurate and stable object approach, with shorter task completion times, which leads to better subsequent manipulation performance. This also provides participants with enhanced psychological experiences, including reduced workload and increased intuitiveness. WDIS improved prosthetic control and user experience in the simplified laboratory settings, providing a foundation for real-world applications.
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 674-685
Open AccessDiscrete Tactile Feedback Based on Weber’s Law Enhances Prosthetic Hand Approaching Performance Under Divided Visual Attention
In multiple vision-demanding tasks, accurately controlling a prosthetic hand to approach a target object is particularly challenging for amputees, as visual attention diverted by other tasks forces them to rely heavily on peripheral vision. This study aims to initially validate that functionally effective sensory feedback can enhance the control of prosthetic hands during object approach under divided visual attention. To quantify prosthesis users' ability to approach and manipulate objects using central and peripheral vision in real-life scenarios, we conducted two experimental tasks—APPROACHING and PINCH—under two visual feedback modes: full-vision and partial-vision. During the approaching process, we compared four feedback conditions: no supplementary sensory feedback (PURE), traditional continuous feedback (CONT), evenly distributed discrete feedback (ADIS), and a novel discrete strategy based on Weber's law (WDIS) proposed in this study. Task performance was evaluated using metrics such as position error, dispersion, task completion time, and pinch failures, while psychological factors were assessed through a questionnaire. Results show that WDIS enabled more accurate and stable object approach, with shorter task completion times, which leads to better subsequent manipulation performance. This also provides participants with enhanced psychological experiences, including reduced workload and increased intuitiveness. WDIS improved prosthetic control and user experience in the simplified laboratory settings, providing a foundation for real-world applications.
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (18) , 29258-29270
A Modified Method of Wearable Gait Analysis for Stroke Patients Based on the Peak Width Threshold and Phase Re-Segmentation
Wearable gait analysis technology offering flexibility and cost-effectiveness, holds significant potential for quantifying the gait functions of stroke patients. It remains a key challenge that how to further reduce cumulative errors by using wearable technology. An algorithm for re-segmenting the gait phase was proposed to improve the precision of zero-velocity detection and gait parameters. The adaptive threshold method was used to separate the stationary phase and the non-stationary phase of the gait cycle. Next, an efficient method called the peak width threshold (PWT) for phase re-segmentation was developed to obtain effective peaks from acceleration and angular velocity data. And the peaks which were incorrectly segmented would be adjusted between the stationary and non-stationary phase. The precision of feet position detection was improved by using zero velocity update (ZUPT) algorithm and dual-foot constraints. Finally, four typical gait parameters were calculated from feet position and phase information. The results demonstrated that the wearable inertial sensors system displays a good agreement compared to the foot pressure-based gait analysis system, and the mean absolute errors (MAE) of the stride length, step length, stride velocity, and cadence are 1.77±1.22 cm, 2.40±1.83 cm, 0.02±0.01 m/s, and 1.16±1.37 steps/min, respectively. This proposed method improves the accuracy of gait phase and feet position detection, which is helpful to objectively evaluate the gait functions of stroke patients.
- 5 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (18) , 29258-29270
A Modified Method of Wearable Gait Analysis for Stroke Patients Based on the Peak Width Threshold and Phase Re-Segmentation
Wearable gait analysis technology offering flexibility and cost-effectiveness, holds significant potential for quantifying the gait functions of stroke patients. It remains a key challenge that how to further reduce cumulative errors by using wearable technology. An algorithm for re-segmenting the gait phase was proposed to improve the precision of zero-velocity detection and gait parameters. The adaptive threshold method was used to separate the stationary phase and the non-stationary phase of the gait cycle. Next, an efficient method called the peak width threshold (PWT) for phase re-segmentation was developed to obtain effective peaks from acceleration and angular velocity data. And the peaks which were incorrectly segmented would be adjusted between the stationary and non-stationary phase. The precision of feet position detection was improved by using zero velocity update (ZUPT) algorithm and dual-foot constraints. Finally, four typical gait parameters were calculated from feet position and phase information. The results demonstrated that the wearable inertial sensors system displays a good agreement compared to the foot pressure-based gait analysis system, and the mean absolute errors (MAE) of the stride length, step length, stride velocity, and cadence are 1.77±1.22 cm, 2.40±1.83 cm, 0.02±0.01 m/s, and 1.16±1.37 steps/min, respectively. This proposed method improves the accuracy of gait phase and feet position detection, which is helpful to objectively evaluate the gait functions of stroke patients.
- Open Access
- 30 May 2024
- Published by Frontiers Media SA in Frontiers in Computer Science
- Vol. 6, 1401560
Object surface roughness/texture recognition using machine vision enables for human-machine haptic interaction
Tactile feedback can effectively improve the controllability of an interactive intelligent robot, and enable users to distinguish the sizes/shapes/compliance of grasped objects. However, it is difficult to recognize object roughness/textures through tactile feedback due to the surface features cannot be acquired with equipped sensors. The purpose of this study is to investigate whether different object roughness/textures can be classified using machine vision and utilized for human-machine haptic interaction. Based on practical application, two classes of specialized datasets, the roughness dataset consisted of different spacing/shapes/height distributions of the surface bulges and the texture dataset included eight types of representative surface textures, were separately established to train the respective classification models. Four kinds of typical deep learning models (YOLOv5l, SSD300, ResNet18, ResNet34) were employed to verify the identification accuracies of surface features corresponding to different roughness/textures. The human fingers' ability to objects roughness recognition also was quantified through a psychophysical experiment with 3D-printed test objects, as a reference benchmark. The computation results showed that the average roughness recognition accuracies based on SSD300, ResNet18, ResNet34 were higher than 95%, which were superior to those of the human fingers (94% and 91% for 2 and 3 levels of object roughness, respectively). The texture recognition accuracies with all models were higher than 84%. Outcomes indicate that object roughness/textures can be effectively classified using machine vision and exploited for human-machine haptic interaction, providing the feasibility of functional sensory restoration of intelligent robots equipped with visual capture and tactile stimulation devices.
- 30 May 2024
- Published by Frontiers Media SA in Frontiers in Computer Science
- Vol. 6, 1401560
Open AccessObject surface roughness/texture recognition using machine vision enables for human-machine haptic interaction
Tactile feedback can effectively improve the controllability of an interactive intelligent robot, and enable users to distinguish the sizes/shapes/compliance of grasped objects. However, it is difficult to recognize object roughness/textures through tactile feedback due to the surface features cannot be acquired with equipped sensors. The purpose of this study is to investigate whether different object roughness/textures can be classified using machine vision and utilized for human-machine haptic interaction. Based on practical application, two classes of specialized datasets, the roughness dataset consisted of different spacing/shapes/height distributions of the surface bulges and the texture dataset included eight types of representative surface textures, were separately established to train the respective classification models. Four kinds of typical deep learning models (YOLOv5l, SSD300, ResNet18, ResNet34) were employed to verify the identification accuracies of surface features corresponding to different roughness/textures. The human fingers' ability to objects roughness recognition also was quantified through a psychophysical experiment with 3D-printed test objects, as a reference benchmark. The computation results showed that the average roughness recognition accuracies based on SSD300, ResNet18, ResNet34 were higher than 95%, which were superior to those of the human fingers (94% and 91% for 2 and 3 levels of object roughness, respectively). The texture recognition accuracies with all models were higher than 84%. Outcomes indicate that object roughness/textures can be effectively classified using machine vision and exploited for human-machine haptic interaction, providing the feasibility of functional sensory restoration of intelligent robots equipped with visual capture and tactile stimulation devices.
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (12) , 16255-16263
A Lightweight Haptic Interface for Hand-to-Object Tasks With Spatiotemporal Displays
Haptic interfaces create information transmission channels from machine to human with a natural way. Robust haptic interfaces with compact forms that provide high information throughput are of particular interest in industrial applications such as teleoperation, soft displays, virtual, and augmented reality. Here, we propose a haptic interface with spatiotemporal displays to convey high-dimensional information during successive hand-to-object tasks, which is architectural and psychophysical lightweight. The wearable and flexible architecture incorporates seven independently addressable vibration units at a pitch of 16 mm to allow spatiotemporal modulation. To prove the superiority of the haptic interface, four-day perceptual experiments are performed on 12 subjects with pattern discrimination tasks. We compared recognition accuracy (RA) between space-dependent and spatiotemporal strategies across the forearm, which are encoded based on finger states and morphological deformations. Furthermore, the mixed biomimetic strategy derived from both is intuitive and showed strength in terms of RA (over 88%) and information transfer (IT) (over 2.4 bit/s). With prior knowledge, are significantly better (RA over 90%) at the discrimination of sequential patterns. Moreover, the results demonstrate robust performance of the biomimetic strategy on location shift, which prove that subjects perceive relative information among vibratory units rather than absolute locations on the skin.
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (12) , 16255-16263
A Lightweight Haptic Interface for Hand-to-Object Tasks With Spatiotemporal Displays
Haptic interfaces create information transmission channels from machine to human with a natural way. Robust haptic interfaces with compact forms that provide high information throughput are of particular interest in industrial applications such as teleoperation, soft displays, virtual, and augmented reality. Here, we propose a haptic interface with spatiotemporal displays to convey high-dimensional information during successive hand-to-object tasks, which is architectural and psychophysical lightweight. The wearable and flexible architecture incorporates seven independently addressable vibration units at a pitch of 16 mm to allow spatiotemporal modulation. To prove the superiority of the haptic interface, four-day perceptual experiments are performed on 12 subjects with pattern discrimination tasks. We compared recognition accuracy (RA) between space-dependent and spatiotemporal strategies across the forearm, which are encoded based on finger states and morphological deformations. Furthermore, the mixed biomimetic strategy derived from both is intuitive and showed strength in terms of RA (over 88%) and information transfer (IT) (over 2.4 bit/s). With prior knowledge, are significantly better (RA over 90%) at the discrimination of sequential patterns. Moreover, the results demonstrate robust performance of the biomimetic strategy on location shift, which prove that subjects perceive relative information among vibratory units rather than absolute locations on the skin.
- 30 January 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (1) , 016038
Neural evidence for functional roles of tactile and visual feedback in the application of myoelectric prosthesis
Objective. The primary purpose of this study was to investigate the electrophysiological mechanism underlying different modalities of sensory feedback and multi-sensory integration in typical prosthesis control tasks. Approach. We recruited 15 subjects and developed a closed-loop setup for three prosthesis control tasks which covered typical activities in the practical prosthesis application, i.e. prosthesis finger position control (PFPC), equivalent grasping force control (GFC) and box and block control (BABC). All the three tasks were conducted under tactile feedback (TF), visual feedback (VF) and tactile-visual feedback (TVF), respectively, with a simultaneous electroencephalography (EEG) recording to assess the electroencephalogram (EEG) response underlying different types of feedback. Behavioral and psychophysical assessments were also administered in each feedback condition. Results. EEG results showed that VF played a predominant role in GFC and BABC tasks. It was reflected by a significantly lower somatosensory alpha event-related desynchronization (ERD) in TVF than in TF and no significant difference in visual alpha ERD between TVF and VF. In PFPC task, there was no significant difference in somatosensory alpha ERD between TF and TVF, while a significantly lower visual alpha ERD was found in TVF than in VF, indicating that TF was essential in situations related to proprioceptive position perception. Tactile-visual integration was found when TF and VF were congruently implemented, showing an obvious activation over the premotor cortex in the three tasks. Behavioral and psychophysical results were consistent with EEG evaluations. Significance. Our findings could provide neural evidence for multi-sensory integration and functional roles of tactile and VF in a practical setting of prosthesis control, shedding a multi-dimensional insight into the functional mechanisms of sensory feedback.
- 30 January 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (1) , 016038
Neural evidence for functional roles of tactile and visual feedback in the application of myoelectric prosthesis
Objective. The primary purpose of this study was to investigate the electrophysiological mechanism underlying different modalities of sensory feedback and multi-sensory integration in typical prosthesis control tasks. Approach. We recruited 15 subjects and developed a closed-loop setup for three prosthesis control tasks which covered typical activities in the practical prosthesis application, i.e. prosthesis finger position control (PFPC), equivalent grasping force control (GFC) and box and block control (BABC). All the three tasks were conducted under tactile feedback (TF), visual feedback (VF) and tactile-visual feedback (TVF), respectively, with a simultaneous electroencephalography (EEG) recording to assess the electroencephalogram (EEG) response underlying different types of feedback. Behavioral and psychophysical assessments were also administered in each feedback condition. Results. EEG results showed that VF played a predominant role in GFC and BABC tasks. It was reflected by a significantly lower somatosensory alpha event-related desynchronization (ERD) in TVF than in TF and no significant difference in visual alpha ERD between TVF and VF. In PFPC task, there was no significant difference in somatosensory alpha ERD between TF and TVF, while a significantly lower visual alpha ERD was found in TVF than in VF, indicating that TF was essential in situations related to proprioceptive position perception. Tactile-visual integration was found when TF and VF were congruently implemented, showing an obvious activation over the premotor cortex in the three tasks. Behavioral and psychophysical results were consistent with EEG evaluations. Significance. Our findings could provide neural evidence for multi-sensory integration and functional roles of tactile and VF in a practical setting of prosthesis control, shedding a multi-dimensional insight into the functional mechanisms of sensory feedback.
- Open Access
- 9 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 1310-1320
Electrotactile Feedback Improves Grip Force Control and Enables Object Stiffness Recognition While Using a Myoelectric Hand
Current myoelectric hands are limited in their ability to provide effective sensory feedback to the users, which highly affects their functionality and utility. Although the sensory information of a myoelectric hand can be acquired with equipped sensors, transforming the sensory signals into effective tactile sensations on users for functional tasks is a largely unsolved challenge. The purpose of this study aims to demonstrate that electrotactile feedback of the grip force improves the sensorimotor control of a myoelectric hand and enables object stiffness recognition. The grip force of a sensorized myoelectric hand was delivered to its users via electrotactile stimulation based on four kinds of typical encoding strategies, including graded (G), linear amplitude (LA), linear frequency (LF), and biomimetic (B) modulation. Object stiffness was encoded with the change of electrotactile sensations triggered by final grip force, as the prosthesis grasped the objects. Ten able-bodied subjects and two transradial amputees were recruited to participate in a dual-task virtual eggs test (VET) and an object stiffness discrimination test (OSDT) to quantify the prosthesis users’ ability to handle fragile objects and recognize object stiffnesses, respectively. The quantified results showed that with electrotactile feedback enabled, the four kinds of encoding strategies allowed subjects to better able to handle fragile objects with similar performance, and the subjects were able to differentiate four levels of object stiffness at favorable accuracies (>86%) and high manual efficiency. Strategy LA presented the best stiffness discrimination performance, while strategy B was able to reduce the discrimination time but the discrimination accuracy was not better than the other three strategies. Electrotactile feedback also enhanced prosthesis embodiment and improved the users’ confidence in prosthetic control. Outcomes indicate electrotactile feedback can be effectively exploited by the prosthesis users for grip force control and object stiffness recognition, proving the feasibility of functional sensory restoration of myoelectric prostheses equipped with electrotactile feedback.
- 9 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 1310-1320
Open AccessElectrotactile Feedback Improves Grip Force Control and Enables Object Stiffness Recognition While Using a Myoelectric Hand
Current myoelectric hands are limited in their ability to provide effective sensory feedback to the users, which highly affects their functionality and utility. Although the sensory information of a myoelectric hand can be acquired with equipped sensors, transforming the sensory signals into effective tactile sensations on users for functional tasks is a largely unsolved challenge. The purpose of this study aims to demonstrate that electrotactile feedback of the grip force improves the sensorimotor control of a myoelectric hand and enables object stiffness recognition. The grip force of a sensorized myoelectric hand was delivered to its users via electrotactile stimulation based on four kinds of typical encoding strategies, including graded (G), linear amplitude (LA), linear frequency (LF), and biomimetic (B) modulation. Object stiffness was encoded with the change of electrotactile sensations triggered by final grip force, as the prosthesis grasped the objects. Ten able-bodied subjects and two transradial amputees were recruited to participate in a dual-task virtual eggs test (VET) and an object stiffness discrimination test (OSDT) to quantify the prosthesis users’ ability to handle fragile objects and recognize object stiffnesses, respectively. The quantified results showed that with electrotactile feedback enabled, the four kinds of encoding strategies allowed subjects to better able to handle fragile objects with similar performance, and the subjects were able to differentiate four levels of object stiffness at favorable accuracies (>86%) and high manual efficiency. Strategy LA presented the best stiffness discrimination performance, while strategy B was able to reduce the discrimination time but the discrimination accuracy was not better than the other three strategies. Electrotactile feedback also enhanced prosthesis embodiment and improved the users’ confidence in prosthetic control. Outcomes indicate electrotactile feedback can be effectively exploited by the prosthesis users for grip force control and object stiffness recognition, proving the feasibility of functional sensory restoration of myoelectric prostheses equipped with electrotactile feedback.
- 1 February 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (1) , 016028
Towards optimizing the non-invasive sensory feedback interfaces in a neural prosthetic control
Objective . The somatotopic interface (SI) and non-somatotopic interface (NI) are commonly used to provide non-invasive sensory feedback. Nevertheless, differences between somatotopic and non-somatotopic feedbacks are rarely reported, and objective evaluations of the corresponding brain response are missing as well. Few studies have reported how to design the stimulation encoding strategy based on the two interfaces in sensory feedback. The objective of this study was to investigate the difference in sensory characteristics between SI and NI, and propose an optimal encoding method for non-invasive feedback interfaces. Approach . We recruited seven amputees and compared the tactile sensitivity to stimulated positions and intensities between SI (phantom finger area) and NI (upper arm) in a tactile discrimination task. Electroencephalography (EEG) evaluation task was subsequently conducted to objectively evaluate the stimulus-evoked brain response for SI and NI. Finally, the two kinds of tactile information (stimulated position and intensity) was applied to an object recognition task in a closed-loop prosthesis control system. Specifically, the object size was reflected by the prosthetic finger position through stimulated position encoding, and the object stiffness was reflected by the contact force of prosthetic fingers through stimulated intensity encoding. We compared the performance under four feedback conditions (combinations between two kinds of tactile information and two interfaces). Main results . Behavioral results showed that NI was more sensitive to position information while SI was more sensitive to intensity information. EEG results were consistent with behavioral results, showing a higher sensitivity of sensory alpha ERD and a stronger correlation between alpha ERD and discrimination accuracies for NI in the position discrimination, while the trend was opposite in the intensity discrimination. The feedback encoding allowed amputees to discriminate the size and stiffness of nine objects with the best performance of 62% overall accuracy (84% for size discrimination, 71% for stiffness discrimination) when position and intensity information was delivered on the NI and SI, respectively. Significance . Our results provided an instructive strategy for sensory feedback via non-invasive solutions.
- 1 February 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (1) , 016028
Towards optimizing the non-invasive sensory feedback interfaces in a neural prosthetic control
Objective . The somatotopic interface (SI) and non-somatotopic interface (NI) are commonly used to provide non-invasive sensory feedback. Nevertheless, differences between somatotopic and non-somatotopic feedbacks are rarely reported, and objective evaluations of the corresponding brain response are missing as well. Few studies have reported how to design the stimulation encoding strategy based on the two interfaces in sensory feedback. The objective of this study was to investigate the difference in sensory characteristics between SI and NI, and propose an optimal encoding method for non-invasive feedback interfaces. Approach . We recruited seven amputees and compared the tactile sensitivity to stimulated positions and intensities between SI (phantom finger area) and NI (upper arm) in a tactile discrimination task. Electroencephalography (EEG) evaluation task was subsequently conducted to objectively evaluate the stimulus-evoked brain response for SI and NI. Finally, the two kinds of tactile information (stimulated position and intensity) was applied to an object recognition task in a closed-loop prosthesis control system. Specifically, the object size was reflected by the prosthetic finger position through stimulated position encoding, and the object stiffness was reflected by the contact force of prosthetic fingers through stimulated intensity encoding. We compared the performance under four feedback conditions (combinations between two kinds of tactile information and two interfaces). Main results . Behavioral results showed that NI was more sensitive to position information while SI was more sensitive to intensity information. EEG results were consistent with behavioral results, showing a higher sensitivity of sensory alpha ERD and a stronger correlation between alpha ERD and discrimination accuracies for NI in the position discrimination, while the trend was opposite in the intensity discrimination. The feedback encoding allowed amputees to discriminate the size and stiffness of nine objects with the best performance of 62% overall accuracy (84% for size discrimination, 71% for stiffness discrimination) when position and intensity information was delivered on the NI and SI, respectively. Significance . Our results provided an instructive strategy for sensory feedback via non-invasive solutions.
- Open Access
- 1 January 2022
- Published by OAE Publishing Inc. in Soft Science
- Vol. 2 (4) , 19
Restoring finger-specific tactile sensations with a sensory soft neuroprosthetic hand through electrotactile stimulation
Tactile feedback is of great significance for amputees to improve the controllability of prosthetic hands and obtain tactile information regarding the interacting objects, which remains a significant challenge for neuroprosthetic hands. In this study, we present a method to restore finger-specific tactile sensations on the projected finger map of a unilateral forearm amputee with a sensory soft neuroprosthetic hand through electrotactile stimulation. On this basis, five soft touch sensors embedded in the fingertips are first adopted to measure the pressure changes of the soft neuroprosthetic hand with the touched objects. The measured pressure information is then accordingly encoded into electrotactile stimulation patterns to trigger an electrical stimulator that outputs programmable electrical pulses on the projected finger map of the amputee. In this manner, the finger tactile sensation can be elicited, which can help the amputee to distinguish the finger press state and discriminate the curvature and hardness of the touched objects. Experimental results show that, based on the different stimulation regions, the amputee subject can instantaneously distinguish the tactile sensation of a single finger or multiple fingers with an accuracy of 98.57% and 91.71%, respectively. By programming the frequencies of the electrical pulses, the amputee subject can successfully discriminate the touching objects with different curvatures and hardnesses with an accuracy of 97.26% and 97.93%, respectively. Finally, we demonstrate that the amputee subject can achieve closed-loop control of the sensory soft neuroprosthetic hand by integrating a myoelectric control interface and electrotactile feedback to achieve multilevel perception.
- 1 January 2022
- Published by OAE Publishing Inc. in Soft Science
- Vol. 2 (4) , 19
Open AccessRestoring finger-specific tactile sensations with a sensory soft neuroprosthetic hand through electrotactile stimulation
Tactile feedback is of great significance for amputees to improve the controllability of prosthetic hands and obtain tactile information regarding the interacting objects, which remains a significant challenge for neuroprosthetic hands. In this study, we present a method to restore finger-specific tactile sensations on the projected finger map of a unilateral forearm amputee with a sensory soft neuroprosthetic hand through electrotactile stimulation. On this basis, five soft touch sensors embedded in the fingertips are first adopted to measure the pressure changes of the soft neuroprosthetic hand with the touched objects. The measured pressure information is then accordingly encoded into electrotactile stimulation patterns to trigger an electrical stimulator that outputs programmable electrical pulses on the projected finger map of the amputee. In this manner, the finger tactile sensation can be elicited, which can help the amputee to distinguish the finger press state and discriminate the curvature and hardness of the touched objects. Experimental results show that, based on the different stimulation regions, the amputee subject can instantaneously distinguish the tactile sensation of a single finger or multiple fingers with an accuracy of 98.57% and 91.71%, respectively. By programming the frequencies of the electrical pulses, the amputee subject can successfully discriminate the touching objects with different curvatures and hardnesses with an accuracy of 97.26% and 97.93%, respectively. Finally, we demonstrate that the amputee subject can achieve closed-loop control of the sensory soft neuroprosthetic hand by integrating a myoelectric control interface and electrotactile feedback to achieve multilevel perception.
- Top Cited Papers
- 16 August 2021
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (4) , 589-598
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Neuroprosthetic hands are typically heavy (over 400 g) and expensive (more than US$10,000), and lack the compliance and tactile feedback of human hands. Here, we report the design, fabrication and performance of a soft, low-cost and lightweight (292 g) neuroprosthetic hand that provides simultaneous myoelectric control and tactile feedback. The neuroprosthesis has six active degrees of freedom under pneumatic actuation, can be controlled through the input from four electromyography sensors that measure surface signals from residual forearm muscles, and integrates five elastomeric capacitive sensors on the fingertips to measure touch pressure so as to enable tactile feedback by eliciting electrical stimulation on the skin of the residual limb. In a set of standardized tests performed by two individuals with transradial amputations, we show that the soft neuroprosthetic hand outperforms a conventional rigid neuroprosthetic hand in speed and dexterity. We also show that one individual with a transradial amputation wearing the soft neuroprosthetic hand can regain primitive touch sensation and real-time closed-loop control.
- 16 August 2021
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (4) , 589-598
Top Cited PapersA soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Neuroprosthetic hands are typically heavy (over 400 g) and expensive (more than US$10,000), and lack the compliance and tactile feedback of human hands. Here, we report the design, fabrication and performance of a soft, low-cost and lightweight (292 g) neuroprosthetic hand that provides simultaneous myoelectric control and tactile feedback. The neuroprosthesis has six active degrees of freedom under pneumatic actuation, can be controlled through the input from four electromyography sensors that measure surface signals from residual forearm muscles, and integrates five elastomeric capacitive sensors on the fingertips to measure touch pressure so as to enable tactile feedback by eliciting electrical stimulation on the skin of the residual limb. In a set of standardized tests performed by two individuals with transradial amputations, we show that the soft neuroprosthetic hand outperforms a conventional rigid neuroprosthetic hand in speed and dexterity. We also show that one individual with a transradial amputation wearing the soft neuroprosthetic hand can regain primitive touch sensation and real-time closed-loop control.
- 1 August 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 0460c6
Detection of human white matter activation and evaluation of its function in movement decoding using stereo-electroencephalography (SEEG)
Objective . White matter tissue takes up approximately 50% of the human brain volume and it is widely known as a messenger conducting information between areas of the central nervous system. However, the characteristics of white matter neural activity and whether white matter neural recordings can contribute to movement decoding are often ignored and still remain largely unknown. In this work, we make quantitative analyses to investigate these two important questions using invasive neural recordings. Approach . We recorded stereo-electroencephalography (SEEG) data from 32 human subjects during a visually-cued motor task, where SEEG recordings can tap into gray and white matter electrical activity simultaneously. Using the proximal tissue density method, we identified the location (i.e. gray or white matter) of each SEEG contact. Focusing on alpha oscillatory and high gamma activities, we compared the activation patterns between gray matter and white matter. Then, we evaluated the performance of such white matter activation in movement decoding. Main results . The results show that white matter also presents activation under the task, in a similar way with the gray matter but at a significantly lower amplitude. Additionally, this work also demonstrates that combing white matter neural activities together with that of gray matter significantly promotes the movement decoding accuracy than using gray matter signals only. Significance . Taking advantage of SEEG recordings from a large number of subjects, we reveal the response characteristics of white matter neural signals under the task and demonstrate its enhancing function in movement decoding. This study highlights the importance of taking white matter activities into consideration in further scientific research and translational applications.
- 1 August 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 0460c6
Detection of human white matter activation and evaluation of its function in movement decoding using stereo-electroencephalography (SEEG)
Objective . White matter tissue takes up approximately 50% of the human brain volume and it is widely known as a messenger conducting information between areas of the central nervous system. However, the characteristics of white matter neural activity and whether white matter neural recordings can contribute to movement decoding are often ignored and still remain largely unknown. In this work, we make quantitative analyses to investigate these two important questions using invasive neural recordings. Approach . We recorded stereo-electroencephalography (SEEG) data from 32 human subjects during a visually-cued motor task, where SEEG recordings can tap into gray and white matter electrical activity simultaneously. Using the proximal tissue density method, we identified the location (i.e. gray or white matter) of each SEEG contact. Focusing on alpha oscillatory and high gamma activities, we compared the activation patterns between gray matter and white matter. Then, we evaluated the performance of such white matter activation in movement decoding. Main results . The results show that white matter also presents activation under the task, in a similar way with the gray matter but at a significantly lower amplitude. Additionally, this work also demonstrates that combing white matter neural activities together with that of gray matter significantly promotes the movement decoding accuracy than using gray matter signals only. Significance . Taking advantage of SEEG recordings from a large number of subjects, we reveal the response characteristics of white matter neural signals under the task and demonstrate its enhancing function in movement decoding. This study highlights the importance of taking white matter activities into consideration in further scientific research and translational applications.