Mostafa Omran Hussein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mostafa Omran Hussein has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alaa Abdelhamid
Dental Research Center (DRC) and Tissue Engineering and Biomaterials Research Unit (TEBRU), Qassim College of Dentistry, Qassim University, Qassim, Saudi Arabia
3 shared publications - Homayoun H. Zadeh
VISTA Institute for Therapeutic Innovations Woodland Hills California USA
3 shared publications Dennis Tarnow
College of Dental Medicine, Columbia University, New York, NY, USA
2 shared publicationsMohammed Suliman Alruthea
Department of Prosthodontic Sciences, College of Dentistry in Ar Rass, Qassim University, El-Qassim, Saudi Arabia
2 shared publicationsNeema Bakhshalian
Laboratory for Immunoregulation and Tissue Engineering (LITE), Ostrow School of Dentistry, University of Southern California, Los Angeles, CA, USA
2 shared publications- Lamis Ahmed Hussein
Dental Biomaterials, Department of Removable Prosthodontics, Faculty of Dentistry, Misr International University, Cairo, Egypt
1 shared publication
Latest Publications
- 1 September 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (3) , 318-326
Photogrammetry technology in implant dentistry: A systematic review
- 1 September 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (3) , 318-326
Photogrammetry technology in implant dentistry: A systematic review
- Open Access
- 1 January 2023
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
- Vol. 12 (01) , 026-033
Dimensional Optimization of Graphene-Modified Polymethyl Methacrylate Material Used as an Aesthetic Removable Partial Denture Clasp Material
Objective Although graphene-modified polymethyl methacrylate material is a good candidate for partial denture clasp material, it lacks adequate strength. Therefore, the study aims to assess the optimal dimension of this nanomodified material required for such an application. Materials and Methods A parametric finite element analysis study was conducted on 54 clasp 3D models at two displacement levels (0.25–0.5 mm) placed 3 mm from the clasp tip. The clasp models were categorized based on the dimensions into A, B, and C (3 subgroups in each) and six tapers from the tip to the base (0.5–1). Both reaction force in (N) and maximum principal stress in (MPa) were recorded and analyzed. The study was validated using the mechanical tester after digital manufacturing of the clasp specimens that showed satisfactory results. Statistical Analysis The correlations between width and thickness against reaction force and maximum principal stress were checked by a statistical analysis software package (SPSS version 22; IBM Corp., Armonk, New York, United States). Data of the reaction force demonstrated nonparametric behavior, as tested by the Kolmogorov–Smirnov test. Accordingly, Spearman's rho test for correlation was used. In contrast, the maximum principal stress data showed normal distribution, as tested by the Kolmogorov–Smirnov test. Thus, Pearson's test of correlation was applied. Results The results demonstrated the best retention force values, considering aesthetics, in subgroups C3 (taper 0.6), C3 (taper 0.8), and B3 (taper 1). The maximum principal stress results showed the highest values in group C followed by group B and then group A. Positive correlations were calculated between thickness and width versus reaction force and maximum principal stress. The correlation coefficient value between thickness and reaction force was 0.699 and that between width and reaction force was 0.621, while the correlation coefficient between thickness and maximum principal force was 0.899 and that between the width and maximum principal force was 0.740. Conclusion It could be concluded that the studied material might be recommended as a valid aesthetic clasp material. Both clasp thickness and width showed a positive correlation with the clasp retention force with more impact by the thickness.
- 1 January 2023
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
- Vol. 12 (01) , 026-033
Open AccessDimensional Optimization of Graphene-Modified Polymethyl Methacrylate Material Used as an Aesthetic Removable Partial Denture Clasp Material
Objective Although graphene-modified polymethyl methacrylate material is a good candidate for partial denture clasp material, it lacks adequate strength. Therefore, the study aims to assess the optimal dimension of this nanomodified material required for such an application. Materials and Methods A parametric finite element analysis study was conducted on 54 clasp 3D models at two displacement levels (0.25–0.5 mm) placed 3 mm from the clasp tip. The clasp models were categorized based on the dimensions into A, B, and C (3 subgroups in each) and six tapers from the tip to the base (0.5–1). Both reaction force in (N) and maximum principal stress in (MPa) were recorded and analyzed. The study was validated using the mechanical tester after digital manufacturing of the clasp specimens that showed satisfactory results. Statistical Analysis The correlations between width and thickness against reaction force and maximum principal stress were checked by a statistical analysis software package (SPSS version 22; IBM Corp., Armonk, New York, United States). Data of the reaction force demonstrated nonparametric behavior, as tested by the Kolmogorov–Smirnov test. Accordingly, Spearman's rho test for correlation was used. In contrast, the maximum principal stress data showed normal distribution, as tested by the Kolmogorov–Smirnov test. Thus, Pearson's test of correlation was applied. Results The results demonstrated the best retention force values, considering aesthetics, in subgroups C3 (taper 0.6), C3 (taper 0.8), and B3 (taper 1). The maximum principal stress results showed the highest values in group C followed by group B and then group A. Positive correlations were calculated between thickness and width versus reaction force and maximum principal stress. The correlation coefficient value between thickness and reaction force was 0.699 and that between width and reaction force was 0.621, while the correlation coefficient between thickness and maximum principal force was 0.899 and that between the width and maximum principal force was 0.740. Conclusion It could be concluded that the studied material might be recommended as a valid aesthetic clasp material. Both clasp thickness and width showed a positive correlation with the clasp retention force with more impact by the thickness.
- Open Access
Performance of Graphene-Based and Polyether-Ether-Ketone Polymers as Removable Partial Denture Esthetic Clasp Materials after Cyclic Fatigue
The esthetic clasp material is a clinical demand for a satisfactory removable partial denture. The purpose of this study is to assess the mechanical performance of graphene-based polymer (GBP) and polyether-ether-ketone (PEEK) materials as clasp materials. Thirty-two clasps were fabricated by CAD-CAM from two materials, GBP and PEEK. All clasps were tested for retention force after 10,000 cycles of insertion and removal and thermocycling. The clasp arms’ deformation was measured, and areas of stress–strain concentration were explored. The Mann–Whitney U test was used to compare the retentive force of the studied groups, while the independent sample t-test was applied to check the difference in clasp arm deformation at α = 0.5. The results showed a significantly higher retentive force (2.248 ± 0.315 N) in PEEK clasps, at p < 0.001. The deformation of the clasp arm of the GBP clasps was significantly higher than PEEK clasps. Areas of stress–strain concentration were seen at the junction of the retentive arm to the minor connector and at the retentive arm terminal. It could be concluded that PEEK polymer had a better mechanical performance as an esthetic clasp material than the GBP. An optimization study for GBP might be required to check the validity of such an application.
Open AccessPerformance of Graphene-Based and Polyether-Ether-Ketone Polymers as Removable Partial Denture Esthetic Clasp Materials after Cyclic Fatigue
The esthetic clasp material is a clinical demand for a satisfactory removable partial denture. The purpose of this study is to assess the mechanical performance of graphene-based polymer (GBP) and polyether-ether-ketone (PEEK) materials as clasp materials. Thirty-two clasps were fabricated by CAD-CAM from two materials, GBP and PEEK. All clasps were tested for retention force after 10,000 cycles of insertion and removal and thermocycling. The clasp arms’ deformation was measured, and areas of stress–strain concentration were explored. The Mann–Whitney U test was used to compare the retentive force of the studied groups, while the independent sample t-test was applied to check the difference in clasp arm deformation at α = 0.5. The results showed a significantly higher retentive force (2.248 ± 0.315 N) in PEEK clasps, at p < 0.001. The deformation of the clasp arm of the GBP clasps was significantly higher than PEEK clasps. Areas of stress–strain concentration were seen at the junction of the retentive arm to the minor connector and at the retentive arm terminal. It could be concluded that PEEK polymer had a better mechanical performance as an esthetic clasp material than the GBP. An optimization study for GBP might be required to check the validity of such an application.
- Open Access
Optimization of Digital Light Processing Three-Dimensional Printing of the Removable Partial Denture Frameworks; The Role of Build Angle and Support Structure Diameter
The optimal three-dimensional (3D) printing parameters of removable partial denture (RPD) frameworks should be studied to achieve the best accuracy, printing time, and least materials consumed. This study aimed to find the best build angle and support structures’ diameter of the 3D printed (RPD) framework. Sixty (RPD) frameworks (10 in each group) were manufactured by digital light processing (DLP) 3D printing technology at three build angles (110-D, 135-D, and 150-D) and two support structures diameters (thick, L, and thin, S). Six groups were named according to their printing setting as (110-DS, 135-DS, 150-DS, 110-DL, 135-DL, and 150-DL). Frameworks were 3D scanned and compared to the original cast surface using 3D metrology software (Geomagic Control X; 3D Systems, Rock Hill, SC). Both printing time and material consumption were also recorded. Data were tested for the significant difference by one-way analysis of variance (ANOVA) test at (α = 0.05). The correlations between outcome parameters were also calculated. The 110-DL group showed the least accuracy. Significantly, the printing time of the 150-D groups had the lowest time. Material consumption of group 110-DS presented the lowest significantly statistical value. Printing time had a linear correlation with both accuracy and material consumption. Within the study limitations, the 150-degree build angle and thin diameter support structures showed optimal accuracy and time-saving regardless of material consumption.
Open AccessOptimization of Digital Light Processing Three-Dimensional Printing of the Removable Partial Denture Frameworks; The Role of Build Angle and Support Structure Diameter
The optimal three-dimensional (3D) printing parameters of removable partial denture (RPD) frameworks should be studied to achieve the best accuracy, printing time, and least materials consumed. This study aimed to find the best build angle and support structures’ diameter of the 3D printed (RPD) framework. Sixty (RPD) frameworks (10 in each group) were manufactured by digital light processing (DLP) 3D printing technology at three build angles (110-D, 135-D, and 150-D) and two support structures diameters (thick, L, and thin, S). Six groups were named according to their printing setting as (110-DS, 135-DS, 150-DS, 110-DL, 135-DL, and 150-DL). Frameworks were 3D scanned and compared to the original cast surface using 3D metrology software (Geomagic Control X; 3D Systems, Rock Hill, SC). Both printing time and material consumption were also recorded. Data were tested for the significant difference by one-way analysis of variance (ANOVA) test at (α = 0.05). The correlations between outcome parameters were also calculated. The 110-DL group showed the least accuracy. Significantly, the printing time of the 150-D groups had the lowest time. Material consumption of group 110-DS presented the lowest significantly statistical value. Printing time had a linear correlation with both accuracy and material consumption. Within the study limitations, the 150-degree build angle and thin diameter support structures showed optimal accuracy and time-saving regardless of material consumption.
- Open Access
- 1 January 2022
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 14 (3) , 150-161
Trueness of 3D printed partial denture frameworks: build orientations and support structure density parameters
Hussein MO, et al. J Adv Prosthodont. 2022 Jun;14(3):150-161. https://doi.org/10.4047/jap.2022.14.3.150
- 1 January 2022
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 14 (3) , 150-161
Open AccessTrueness of 3D printed partial denture frameworks: build orientations and support structure density parameters
Hussein MO, et al. J Adv Prosthodont. 2022 Jun;14(3):150-161. https://doi.org/10.4047/jap.2022.14.3.150
- Open Access
- 28 January 2021
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 15 (03) , 454-462
Evaluation of Bone–Implant Interface Stress and Strain Using Heterogeneous Mandibular Bone Properties Based on Different Empirical Correlations
Objectives The purpose of this study was to compare methods used for calculating heterogeneous patient-specific bone properties used in finite element analysis (FEA), in the field of implant dentistry, with the method based on homogenous bone properties.Materials and Methods In this study, three-dimensional (3D) computed tomography data of an edentulous patient were processed to create a finite element model, and five identical 3D implant models were created and distributed throughout the dental arch. Based on the calculation methods used for bone material assignment, four groups—groups I to IV—were defined. Groups I to III relied on heterogeneous bone property assignment based on different equations, whereas group IV relied on homogenous bone properties. Finally, 150 N vertical and 60-degree-inclined forces were applied at the top of the implant abutments to calculate the von Mises stress and strain.Results Groups I and II presented the highest stress and strain values, respectively. Based on the implant location, differences were observed between the stress values of group I, II, and III compared with group IV; however, no clear order was noted. Accordingly, variable von Mises stress and strain reactions at the bone–implant interface were observed among the heterogeneous bone property groups when compared with the homogenous property group results at the same implant positions.Conclusion Although the use of heterogeneous bone properties as material assignments in FEA studies seem promising for patient-specific analysis, the variations between their results raise doubts about their reliability. The results were influenced by implants’ locations leading to misleading clinical simulations.
- 28 January 2021
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 15 (03) , 454-462
Open AccessEvaluation of Bone–Implant Interface Stress and Strain Using Heterogeneous Mandibular Bone Properties Based on Different Empirical Correlations
Objectives The purpose of this study was to compare methods used for calculating heterogeneous patient-specific bone properties used in finite element analysis (FEA), in the field of implant dentistry, with the method based on homogenous bone properties.Materials and Methods In this study, three-dimensional (3D) computed tomography data of an edentulous patient were processed to create a finite element model, and five identical 3D implant models were created and distributed throughout the dental arch. Based on the calculation methods used for bone material assignment, four groups—groups I to IV—were defined. Groups I to III relied on heterogeneous bone property assignment based on different equations, whereas group IV relied on homogenous bone properties. Finally, 150 N vertical and 60-degree-inclined forces were applied at the top of the implant abutments to calculate the von Mises stress and strain.Results Groups I and II presented the highest stress and strain values, respectively. Based on the implant location, differences were observed between the stress values of group I, II, and III compared with group IV; however, no clear order was noted. Accordingly, variable von Mises stress and strain reactions at the bone–implant interface were observed among the heterogeneous bone property groups when compared with the homogenous property group results at the same implant positions.Conclusion Although the use of heterogeneous bone properties as material assignments in FEA studies seem promising for patient-specific analysis, the variations between their results raise doubts about their reliability. The results were influenced by implants’ locations leading to misleading clinical simulations.
- Open Access
- 10 August 2020
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 14 (04) , 590-597
Marginal Bone Level Changes and Oral Health Impact Profile (14) Score of Smokers Treated by Mandibular Mini Implant Overdentures: A 5-Year Follow-up Study
Objectives Studies considered edentulous patients having smoking habit as a compromised oral condition. This research examined the value of using mini implant mandibular overdenture to maintain long-term satisfactory levels of oral health quality of life and marginal vertical bone loss. Materials and Methods Twenty-nine edentulous patients with smoking habit received four mini implants in the mandible loaded by overdentures. The present study monitored patients radiographically for vertical bone loss after (1 month, 1, 3, and 5 years) of treatment. Patients were also evaluated by oral health impact profile 14 (OHIP-14) pretreatment and at 1 and 5 years of treatment. Statistical Analysis Repeated measure analysis of variance with Bonferroni’s test as a post-hoc test was used to see the difference among time points. Independent sample t-tests were used to compare between anterior and posterior mini implant positions after 5 years of follow-up. OHIP-14 questionnaire was analyzed by Wilcoxon signed ranks for pairwise comparisons at different evaluation times. A Holm-Bonferroni correction method was used to control the familywise error rate. Results The mean of the bone height changes showed a significant difference between 1-month data and all other evaluation intervals while no significance was calculated among other evaluation intervals. Bone loss of the mini implants placed anteriorly was less than those placed posteriorly with a statistically significant difference. A significant reduction in the OHIP-14 score levels was observed between pretreatment and both 1 and 5 years of treatment. No significance was seen between the first and fifth year after treatment. Conclusion Mini implant overdenture could maintain satisfactory marginal bone level changes and oral health quality of life for patients with smoking habit after 5-year follow-up period.
- 10 August 2020
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 14 (04) , 590-597
Open AccessMarginal Bone Level Changes and Oral Health Impact Profile (14) Score of Smokers Treated by Mandibular Mini Implant Overdentures: A 5-Year Follow-up Study
Objectives Studies considered edentulous patients having smoking habit as a compromised oral condition. This research examined the value of using mini implant mandibular overdenture to maintain long-term satisfactory levels of oral health quality of life and marginal vertical bone loss. Materials and Methods Twenty-nine edentulous patients with smoking habit received four mini implants in the mandible loaded by overdentures. The present study monitored patients radiographically for vertical bone loss after (1 month, 1, 3, and 5 years) of treatment. Patients were also evaluated by oral health impact profile 14 (OHIP-14) pretreatment and at 1 and 5 years of treatment. Statistical Analysis Repeated measure analysis of variance with Bonferroni’s test as a post-hoc test was used to see the difference among time points. Independent sample t-tests were used to compare between anterior and posterior mini implant positions after 5 years of follow-up. OHIP-14 questionnaire was analyzed by Wilcoxon signed ranks for pairwise comparisons at different evaluation times. A Holm-Bonferroni correction method was used to control the familywise error rate. Results The mean of the bone height changes showed a significant difference between 1-month data and all other evaluation intervals while no significance was calculated among other evaluation intervals. Bone loss of the mini implants placed anteriorly was less than those placed posteriorly with a statistically significant difference. A significant reduction in the OHIP-14 score levels was observed between pretreatment and both 1 and 5 years of treatment. No significance was seen between the first and fifth year after treatment. Conclusion Mini implant overdenture could maintain satisfactory marginal bone level changes and oral health quality of life for patients with smoking habit after 5-year follow-up period.
- 1 October 2018
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 64 (4) , 3609-3621
Randomized controlled clinical trial of implant overdenture retained with zirconia bars or telescopic crowns: a 1-year follow-up
Implant retained overdenture is a popular treatment for edentulous patients whether splinted orsolitary attachments were used. The aim of the study was to examine the difference between barand telescopic overdenture attachment fabricated from zirconia. Ten male patients were selectedto receive implant overdenture retained by two implants at para-sympheseal zone. These patientswere categorized into two groups based on the type of attachment used. Group (A) was the barconnectedgroup while group (B) was the telescopic attachment group. Both bone height and bonedensity were monitored, using cone beam computerized tomography, throughout the follow upperiods (at loading time, three, six and twelve months). The results showed the mean values ofperi-implant bone height loss of group A were less than group B with statistically significant values(P< 0.05). The mean values of the bone density showed higher bone density values in group A thangroup B with statistically significant value at (P < 0.05). It could be concluded that the zirconiabar-attachment overdenture showed better treatment outcomes than zirconia telescopic attachment.Accordingly, the bar-clip attachment system showed some preference in preserving peri-implantbone surround the implants.
- 1 October 2018
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 64 (4) , 3609-3621
Randomized controlled clinical trial of implant overdenture retained with zirconia bars or telescopic crowns: a 1-year follow-up
Implant retained overdenture is a popular treatment for edentulous patients whether splinted orsolitary attachments were used. The aim of the study was to examine the difference between barand telescopic overdenture attachment fabricated from zirconia. Ten male patients were selectedto receive implant overdenture retained by two implants at para-sympheseal zone. These patientswere categorized into two groups based on the type of attachment used. Group (A) was the barconnectedgroup while group (B) was the telescopic attachment group. Both bone height and bonedensity were monitored, using cone beam computerized tomography, throughout the follow upperiods (at loading time, three, six and twelve months). The results showed the mean values ofperi-implant bone height loss of group A were less than group B with statistically significant values(P< 0.05). The mean values of the bone density showed higher bone density values in group A thangroup B with statistically significant value at (P < 0.05). It could be concluded that the zirconiabar-attachment overdenture showed better treatment outcomes than zirconia telescopic attachment.Accordingly, the bar-clip attachment system showed some preference in preserving peri-implantbone surround the implants.
- 2 November 2015
- Published by Wiley in Clinical Oral Implants Research
- Vol. 27 (6) , 640-649
An open randomized controlled clinical trial to evaluate ridge preservation and repair using SocketKAP™and SocketKAGE™: part 1‐three‐dimensional volumetric soft tissue analysis of study casts
Objectives: The aims of this study were to evaluate (i) the efficacy of ridge preservation and repair involving SocketKAP™and SocketKAGE™devices following tooth removal; and (ii) ridge contour changes at 6 months post‐extraction in intact sockets and sockets with dehiscence defects.Material and methods: Thirty‐six patients required a total of 61 teeth to be extracted. Five cohorts were established with groups A–C involving intact sockets and groups D and E involving facial dehiscence: (A) Negative Control; (B) SocketKAP™alone; (C) Anorganic Bovine Bone Mineral (ABBM) + SocketKAP™; (D) Negative Control; and (E)ABBM + SocketKAP™ + SocketKAGE™. PreoperativeCBCTand laser‐scanned casts were obtained. Teeth segmented from preoperativeCBCTwere merged with study cast images to allow for digital removal of teeth from the casts. Volumetric measurements of ridge contour were performed. Images of preoperative and 6 months post‐operative casts were superimposed to measure ridge contour changes.Results: Post‐extraction contour loss occurred in all sockets primarily in the crestal 3 mm but was also detected up to 6 mm from alveolar crest. For intact sockets, SocketKAP™or SocketKAP™ + ABBMinterventions led to greater percentages of remaining ridge contour when compared to controls. A significant difference favoring SocketKAP™ + SocketKAGE™ + ABBMtreatment was observed for sockets with facial dehiscence when compared to controls.Conclusion: SocketKAP™, with or withoutABBM, significantly limited post‐extraction ridge contour loss in intact sockets. In the absence of a group treated with only the SocketKAGE™, it is not possible to determine its efficacy, although the combination of SocketKAGE™ + SocketKAP™ + ABBMwas effective in limiting post‐extraction ridge contour loss in sockets with dehiscence defects.
- 2 November 2015
- Published by Wiley in Clinical Oral Implants Research
- Vol. 27 (6) , 640-649
An open randomized controlled clinical trial to evaluate ridge preservation and repair using SocketKAP™and SocketKAGE™: part 1‐three‐dimensional volumetric soft tissue analysis of study casts
Objectives: The aims of this study were to evaluate (i) the efficacy of ridge preservation and repair involving SocketKAP™and SocketKAGE™devices following tooth removal; and (ii) ridge contour changes at 6 months post‐extraction in intact sockets and sockets with dehiscence defects.Material and methods: Thirty‐six patients required a total of 61 teeth to be extracted. Five cohorts were established with groups A–C involving intact sockets and groups D and E involving facial dehiscence: (A) Negative Control; (B) SocketKAP™alone; (C) Anorganic Bovine Bone Mineral (ABBM) + SocketKAP™; (D) Negative Control; and (E)ABBM + SocketKAP™ + SocketKAGE™. PreoperativeCBCTand laser‐scanned casts were obtained. Teeth segmented from preoperativeCBCTwere merged with study cast images to allow for digital removal of teeth from the casts. Volumetric measurements of ridge contour were performed. Images of preoperative and 6 months post‐operative casts were superimposed to measure ridge contour changes.Results: Post‐extraction contour loss occurred in all sockets primarily in the crestal 3 mm but was also detected up to 6 mm from alveolar crest. For intact sockets, SocketKAP™or SocketKAP™ + ABBMinterventions led to greater percentages of remaining ridge contour when compared to controls. A significant difference favoring SocketKAP™ + SocketKAGE™ + ABBMtreatment was observed for sockets with facial dehiscence when compared to controls.Conclusion: SocketKAP™, with or withoutABBM, significantly limited post‐extraction ridge contour loss in intact sockets. In the absence of a group treated with only the SocketKAGE™, it is not possible to determine its efficacy, although the combination of SocketKAGE™ + SocketKAP™ + ABBMwas effective in limiting post‐extraction ridge contour loss in sockets with dehiscence defects.
- 31 October 2015
- Published by Wiley in Clinical Oral Implants Research
- Vol. 27 (6) , 631-639
An open randomized controlled clinical trial to evaluate ridge preservation and repair using SocketKAP™ and SocketKAGE™: part 2 – three‐dimensional alveolar bone volumetric analysis of CBCT imaging
Objectives: The aims of this study were (i) to evaluate the efficacy of ridge preservation and repair procedures involving the application of SocketKAP™ and SocketKAGE™ devices following tooth removal and (ii) to evaluate alveolar bone volumetric changes at 6 months post‐extraction in intact sockets or those with facial wall dehiscence defects using 3‐dimensional pre‐ and postoperative CBCT data.Materials and Methods: Thirty‐six patients required 61 teeth extracted. Five cohorts were established: Group A: Intact Socket Negative Control Group B: Intact Socket + SocketKAP™ Group C: Intact Socket Filled with Anorganic Bovine Bone Mineral (ABBM) + SocketKAP™ Group D: Facial Dehiscence Socket Negative Control Group E: Facial Dehiscence Socket Filled with ABBM + SocketKAP™ + SocketKAGE™. Preoperative CBCT scans were obtained followed by digital subtraction of the test teeth. At 6 months post‐extraction, another CBCT scan was obtained. The pre‐ and postoperative scans were then superimposed, allowing highly accurate quantitative determination of the 3D volumetric alveolar bone volume changes from baseline through 6 months.Results: Significant volumetric bone loss occurred in all sockets, localized mainly in the 0–3 mm zone apical to the ridge crest. For intact sockets, SocketKAP™ + ABBM treatment led to a statistically significant greater percentage of remaining mineralized tissue volume when compared to negative control group. A significant difference favoring SocketKAP™ + SocketKAGE™ + ABBM treatment was observed for sockets with facial dehiscence defects compared to the negative control group.Conclusions: SocketKAP™, with ABBM, appears effective in limiting post‐extraction volumetric bone loss in intact sockets, while SocketKAP™ + SocketKAGE + ABBM appears effective in limiting post‐extraction bone loss in sockets with dehiscence defects.
- 31 October 2015
- Published by Wiley in Clinical Oral Implants Research
- Vol. 27 (6) , 631-639
An open randomized controlled clinical trial to evaluate ridge preservation and repair using SocketKAP™ and SocketKAGE™: part 2 – three‐dimensional alveolar bone volumetric analysis of CBCT imaging
Objectives: The aims of this study were (i) to evaluate the efficacy of ridge preservation and repair procedures involving the application of SocketKAP™ and SocketKAGE™ devices following tooth removal and (ii) to evaluate alveolar bone volumetric changes at 6 months post‐extraction in intact sockets or those with facial wall dehiscence defects using 3‐dimensional pre‐ and postoperative CBCT data.Materials and Methods: Thirty‐six patients required 61 teeth extracted. Five cohorts were established: Group A: Intact Socket Negative Control Group B: Intact Socket + SocketKAP™ Group C: Intact Socket Filled with Anorganic Bovine Bone Mineral (ABBM) + SocketKAP™ Group D: Facial Dehiscence Socket Negative Control Group E: Facial Dehiscence Socket Filled with ABBM + SocketKAP™ + SocketKAGE™. Preoperative CBCT scans were obtained followed by digital subtraction of the test teeth. At 6 months post‐extraction, another CBCT scan was obtained. The pre‐ and postoperative scans were then superimposed, allowing highly accurate quantitative determination of the 3D volumetric alveolar bone volume changes from baseline through 6 months.Results: Significant volumetric bone loss occurred in all sockets, localized mainly in the 0–3 mm zone apical to the ridge crest. For intact sockets, SocketKAP™ + ABBM treatment led to a statistically significant greater percentage of remaining mineralized tissue volume when compared to negative control group. A significant difference favoring SocketKAP™ + SocketKAGE™ + ABBM treatment was observed for sockets with facial dehiscence defects compared to the negative control group.Conclusions: SocketKAP™, with ABBM, appears effective in limiting post‐extraction volumetric bone loss in intact sockets, while SocketKAP™ + SocketKAGE + ABBM appears effective in limiting post‐extraction bone loss in sockets with dehiscence defects.