Rongan Zhai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Rongan Zhai has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Changhai Ru
Soochow University
4 shared publications - Miao Hao
Research Center of Robotics and Micro Systems, School of Mechanical and Electrical Engineering, Soochow University, Suzhou 215021, China
4 shared publications - Yu Sun
Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
4 shared publications Chunfeng Yue
Suzhou Boundless Medical Technology Company Ltd
3 shared publications- Yong Wang
School of Electronic and Information Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
3 shared publications - Aojun Jiang
University of Toronto
2 shared publications
Latest Publications
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (5) , 1781-1793
Fully On-Smartphone: Efficient Speed-Up of Sperm Tracking Algorithm for Point-of-Care Semen Analysis
To develop a lowcost, accurate, and fully-on-smartphone system for pointofcare semen analysis and to address the computational bottlenecks in dense sperm tracking on resourceconstrained devices. A portable optical attachment enabling microscopic video acquisition through consumer-grade smartphone cameras was developed. Initial deployment of the Joint Probabilistic Data Association Filter (JPDAF) on legacy mobile hardware revealed critical computational bottlenecks, where high-density semen samples ($\approx$ 80 million sperm/mL) induced exponential processing delays exceeding 3 hours due to exhaustive enumeration of feasible joint events in highdensity local regions. To overcome this limitation, the Global-Local Integrated JPDAF (GLIJPDAF) was proposed, featuring a twostage clustering strategy: (1) global clustering via a nondiagonal matrix partitioning algorithm to split the validation matrix into sparse submatrices isolating homogeneous association regions; (2) local clustering with a dynamic kmeans++ algorithm (adaptive k based on local non-zero density) to cap enumeration complexity. Validation across four smartphone platforms using 90 patient samples (50-250 million sperm/mL) demonstrated that GLIJPDAF achieved a mean concentration error of 0.84 million/mL and a mean motility error of 0.74%. Processing times per 3s video remained under 120s on all devices. Integrating GLIJPDAF into a smartphone platform enables rapid, accurate pointofcare semen analysis in highdensity samples on resourcelimited devices. This accessible pointofcare solution has the potential to broaden male infertility screening in lowresource settings.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (5) , 1781-1793
Fully On-Smartphone: Efficient Speed-Up of Sperm Tracking Algorithm for Point-of-Care Semen Analysis
To develop a lowcost, accurate, and fully-on-smartphone system for pointofcare semen analysis and to address the computational bottlenecks in dense sperm tracking on resourceconstrained devices. A portable optical attachment enabling microscopic video acquisition through consumer-grade smartphone cameras was developed. Initial deployment of the Joint Probabilistic Data Association Filter (JPDAF) on legacy mobile hardware revealed critical computational bottlenecks, where high-density semen samples ($\approx$ 80 million sperm/mL) induced exponential processing delays exceeding 3 hours due to exhaustive enumeration of feasible joint events in highdensity local regions. To overcome this limitation, the Global-Local Integrated JPDAF (GLIJPDAF) was proposed, featuring a twostage clustering strategy: (1) global clustering via a nondiagonal matrix partitioning algorithm to split the validation matrix into sparse submatrices isolating homogeneous association regions; (2) local clustering with a dynamic kmeans++ algorithm (adaptive k based on local non-zero density) to cap enumeration complexity. Validation across four smartphone platforms using 90 patient samples (50-250 million sperm/mL) demonstrated that GLIJPDAF achieved a mean concentration error of 0.84 million/mL and a mean motility error of 0.74%. Processing times per 3s video remained under 120s on all devices. Integrating GLIJPDAF into a smartphone platform enables rapid, accurate pointofcare semen analysis in highdensity samples on resourcelimited devices. This accessible pointofcare solution has the potential to broaden male infertility screening in lowresource settings.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 6198-6208
Automated Sperm Immobilization With Compensation for Sperm Intrinsic and Fluid Flow-Induced Movements
In automated sperm immobilization, motorized stages are conventional means for transporting sperm, while they are not typical devices in clinical setups. This study designs a new robotic sperm immobilization method by leveraging a micromanipulator to position a tooltip above sperm for immobilizing it without a motorized stage. The challenge arises when tooltip motion agitates the medium, leading to the passive displacement of sperm, and the sperm's intrinsic movement also complicates tooltip positioning. To address these concerns, first, a predictor is introduced to predict the sperm's intrinsic movement. Second, a model is established to describe the fluid flow and characterize the passive displacement of sperm as a function of tooltip velocity and medium parameters. Finally, an adaptive control algorithm that accounts for uncalibrated medium parameters is designed to compensate for the sperm's intrinsic movement and tooltip motion-induced sperm displacement. The stability of the control algorithm is analyzed, and the boundedness of the positioning error is proven. Experiments verified the effectiveness of the proposed method in both predicting and feedforwarding sperm's intrinsic movement and in compensating for tooltip motion-induced sperm displacement. The performance of the proposed method is comparable to existing robotic sperm immobilization methods that rely on motorized stages, while being easier to implement in clinics. With the proposed method, the system achieved a success rate of 90.9% in sperm immobilization, representing an improvement of 28.2% over the method not factoring in the sperm's intrinsic movement and 16.3% over the method not accounting for the tooltip motion-induced sperm displacement, respectively.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 6198-6208
Automated Sperm Immobilization With Compensation for Sperm Intrinsic and Fluid Flow-Induced Movements
In automated sperm immobilization, motorized stages are conventional means for transporting sperm, while they are not typical devices in clinical setups. This study designs a new robotic sperm immobilization method by leveraging a micromanipulator to position a tooltip above sperm for immobilizing it without a motorized stage. The challenge arises when tooltip motion agitates the medium, leading to the passive displacement of sperm, and the sperm's intrinsic movement also complicates tooltip positioning. To address these concerns, first, a predictor is introduced to predict the sperm's intrinsic movement. Second, a model is established to describe the fluid flow and characterize the passive displacement of sperm as a function of tooltip velocity and medium parameters. Finally, an adaptive control algorithm that accounts for uncalibrated medium parameters is designed to compensate for the sperm's intrinsic movement and tooltip motion-induced sperm displacement. The stability of the control algorithm is analyzed, and the boundedness of the positioning error is proven. Experiments verified the effectiveness of the proposed method in both predicting and feedforwarding sperm's intrinsic movement and in compensating for tooltip motion-induced sperm displacement. The performance of the proposed method is comparable to existing robotic sperm immobilization methods that rely on motorized stages, while being easier to implement in clinics. With the proposed method, the system achieved a success rate of 90.9% in sperm immobilization, representing an improvement of 28.2% over the method not factoring in the sperm's intrinsic movement and 16.3% over the method not accounting for the tooltip motion-induced sperm displacement, respectively.
- Open Access
A Stained-Free Sperm Morphology Measurement Method Based on Multi-Target Instance Parsing and Measurement Accuracy Enhancement
Sperm morphology assessment plays a vital role in semen analysis and the diagnosis of male infertility. By quantitatively analyzing the morphological characteristics of the sperm head, midpiece, and tail, it provides essential insights for assisted reproductive technologies (ARTs), such as in vitro fertilization (IVF). However, traditional manual evaluation methods not only rely on staining procedures that can damage the cells but also suffer from strong subjectivity and inconsistent results, underscoring the urgent need for an automated, accurate, and non-invasive method for multi-sperm morphology assessment. To address the limitations of existing techniques, this study proposes a novel method that combines a multi-scale part parsing network with a measurement accuracy enhancement strategy for non-stained sperm morphology analysis. First, a multi-scale part parsing network integrating semantic segmentation and instance segmentation is introduced to achieve instance-level parsing of sperm, enabling precise measurement of morphological parameters for each individual sperm instance. Second, to eliminate measurement errors caused by the reduced resolution of non-stained sperm images, a measurement accuracy enhancement method based on statistical analysis and signal processing is designed. This method employs an interquartile range (IQR) method to exclude outliers, Gaussian filtering to smooth data, and robust correction techniques to extract the maximum morphological features of sperm. Experimental results demonstrate that the proposed multi-scale part parsing network achieves 59.3% , surpassing the state-of-the-art AIParsing by 9.20%. Compared to evaluations based solely on segmentation results, the integration of the measurement accuracy enhancement strategy significantly reduces measurement errors, with the largest reduction in errors for head, midpiece, and tail measurements reaching up to 35.0%.Open AccessA Stained-Free Sperm Morphology Measurement Method Based on Multi-Target Instance Parsing and Measurement Accuracy Enhancement
Sperm morphology assessment plays a vital role in semen analysis and the diagnosis of male infertility. By quantitatively analyzing the morphological characteristics of the sperm head, midpiece, and tail, it provides essential insights for assisted reproductive technologies (ARTs), such as in vitro fertilization (IVF). However, traditional manual evaluation methods not only rely on staining procedures that can damage the cells but also suffer from strong subjectivity and inconsistent results, underscoring the urgent need for an automated, accurate, and non-invasive method for multi-sperm morphology assessment. To address the limitations of existing techniques, this study proposes a novel method that combines a multi-scale part parsing network with a measurement accuracy enhancement strategy for non-stained sperm morphology analysis. First, a multi-scale part parsing network integrating semantic segmentation and instance segmentation is introduced to achieve instance-level parsing of sperm, enabling precise measurement of morphological parameters for each individual sperm instance. Second, to eliminate measurement errors caused by the reduced resolution of non-stained sperm images, a measurement accuracy enhancement method based on statistical analysis and signal processing is designed. This method employs an interquartile range (IQR) method to exclude outliers, Gaussian filtering to smooth data, and robust correction techniques to extract the maximum morphological features of sperm. Experimental results demonstrate that the proposed multi-scale part parsing network achieves 59.3% , surpassing the state-of-the-art AIParsing by 9.20%. Compared to evaluations based solely on segmentation results, the integration of the measurement accuracy enhancement strategy significantly reduces measurement errors, with the largest reduction in errors for head, midpiece, and tail measurements reaching up to 35.0%. - Open Access
- 19 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8450
Robotic Manipulation of Cumulus–Oocyte Complexes for Cumulus Cell Removal
The removal of cumulus cells from cumulus–oocyte complexes is a critical step in clinical in vitro fertilization. Since the oocyte is partially occluded by the surrounding cumulus cells and individual cumulus cells are small in size, it is difficult for embryologists to assess the oocyte's maturity before cumulus cell removal and to completely remove all the cumulus cells manually . Furthermore, it is easy for the oocyte to become lost inside the micropipette during aspiration due to the inaccuracy of manual control. To deal with these difficulties, a robotic system was developed to completely remove cumulus cells from mature oocytes. In this study, an EPSANet50 network was developed to accurately assess the maturity of oocytes, avoiding the removal of cumulus cells around the immature oocyte. An adaptive controller was designed to accurately position oocytes at the target position, reducing the loss of oocytes inside the micropipette. An improved Yolov5s network was proposed to quantify the number and size of cumulus cells and assess the completeness of cumulus cell removal. The experimental results on mouse cumulus–oocyte complexes showed that the robotic system had a higher success rate (98.0 ± 1.8% vs. 85.3 ± 2.4%) and lower discard rate (4.1 ± 2.7% vs. 19.6 ± 3.5%) than the manual operation. Moreover, a higher amplification rate and lower non-specific rate were also achieved by the robotic system in the subsequent genetic testing procedure, indicating reduced genetic contamination from the cumulus cells.
- 19 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8450
Open AccessRobotic Manipulation of Cumulus–Oocyte Complexes for Cumulus Cell Removal
The removal of cumulus cells from cumulus–oocyte complexes is a critical step in clinical in vitro fertilization. Since the oocyte is partially occluded by the surrounding cumulus cells and individual cumulus cells are small in size, it is difficult for embryologists to assess the oocyte's maturity before cumulus cell removal and to completely remove all the cumulus cells manually . Furthermore, it is easy for the oocyte to become lost inside the micropipette during aspiration due to the inaccuracy of manual control. To deal with these difficulties, a robotic system was developed to completely remove cumulus cells from mature oocytes. In this study, an EPSANet50 network was developed to accurately assess the maturity of oocytes, avoiding the removal of cumulus cells around the immature oocyte. An adaptive controller was designed to accurately position oocytes at the target position, reducing the loss of oocytes inside the micropipette. An improved Yolov5s network was proposed to quantify the number and size of cumulus cells and assess the completeness of cumulus cell removal. The experimental results on mouse cumulus–oocyte complexes showed that the robotic system had a higher success rate (98.0 ± 1.8% vs. 85.3 ± 2.4%) and lower discard rate (4.1 ± 2.7% vs. 19.6 ± 3.5%) than the manual operation. Moreover, a higher amplification rate and lower non-specific rate were also achieved by the robotic system in the subsequent genetic testing procedure, indicating reduced genetic contamination from the cumulus cells.
- 5 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 2335-2348
Automated Point-of-Care Semen Analysis Using Smartphone Imaging and Occlusion-Aware Multi-Object Tracking
This paper presents an automated point-of-care semen analysis method that uses smartphone imaging to visually measure sperm concentration and motility of semen samples. The proposed method follows the same visual tracking scheme as laboratory semen analysis systems, aiming to match clinical standards while being suitable for point-of-care use. A boundary-sensitive segmentation network is developed to identify and distinguish sperm from impurities in raw semen. A novel occlusion-aware multi-sperm tracking algorithm is proposed to tackle challenges posed by smartphone imaging and undiluted raw semen samples. For automated motility measurement, an occlusion-awareness module is proposed to robustly track multiple sperm during frequent sperm crossover/occlusion. The module combines the segmented contour and kinematic-based probabilistic modeling to determine the occlusion status of both targets and measurements, facilitating fundamental improvement to feasible joint event enumeration to enable robust data association. The proposed method achieved a high success rate of 95.14% for tracking occluded sperm, with low mean errors for sperm concentration (2.03 million/ml) and motility (1.58%), outperforming existing multi-sperm tracking methods. In clinical tests involving 50 participants, our method exhibited good agreement with clinical standards (Spearman rank correlation coefficients of 0.94 for concentration and 0.89 for motility) even when used by inexperienced users. Note to Practitioners —Semen analysis is the gold standard method for assessing male reproductive capacity. Clinical semen analysis routinely uses professional computer-assisted semen analysis (CASA) systems to examine sperm concentration and motility; however, clinical visits for semen analysis are not always feasible due to the unavailability of such professional systems and the mental stress brought by clinical visits. This work provides a point-of-care semen analysis method. For hardware, a smartphone microscopic imaging modality was developed to enable clear visualization of sperm with the built-in smartphone camera. For software, an occlusion-aware multi-sperm tracking algorithm was proposed to automatically measure sperm concentration and motility. In addition to intensively validating the proposed point-of-care method against clinical CASA systems, this work also analyzed different types of tracking failure and quantified their effects on the automated evaluation of sperm concentration and motility. The techniques pave the way for further improvement in both point-of-care and clinical semen analysis. Overall, this work offers an accessible and reliable tool for automated male fertility evaluation.
- 5 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 2335-2348
Automated Point-of-Care Semen Analysis Using Smartphone Imaging and Occlusion-Aware Multi-Object Tracking
This paper presents an automated point-of-care semen analysis method that uses smartphone imaging to visually measure sperm concentration and motility of semen samples. The proposed method follows the same visual tracking scheme as laboratory semen analysis systems, aiming to match clinical standards while being suitable for point-of-care use. A boundary-sensitive segmentation network is developed to identify and distinguish sperm from impurities in raw semen. A novel occlusion-aware multi-sperm tracking algorithm is proposed to tackle challenges posed by smartphone imaging and undiluted raw semen samples. For automated motility measurement, an occlusion-awareness module is proposed to robustly track multiple sperm during frequent sperm crossover/occlusion. The module combines the segmented contour and kinematic-based probabilistic modeling to determine the occlusion status of both targets and measurements, facilitating fundamental improvement to feasible joint event enumeration to enable robust data association. The proposed method achieved a high success rate of 95.14% for tracking occluded sperm, with low mean errors for sperm concentration (2.03 million/ml) and motility (1.58%), outperforming existing multi-sperm tracking methods. In clinical tests involving 50 participants, our method exhibited good agreement with clinical standards (Spearman rank correlation coefficients of 0.94 for concentration and 0.89 for motility) even when used by inexperienced users. Note to Practitioners —Semen analysis is the gold standard method for assessing male reproductive capacity. Clinical semen analysis routinely uses professional computer-assisted semen analysis (CASA) systems to examine sperm concentration and motility; however, clinical visits for semen analysis are not always feasible due to the unavailability of such professional systems and the mental stress brought by clinical visits. This work provides a point-of-care semen analysis method. For hardware, a smartphone microscopic imaging modality was developed to enable clear visualization of sperm with the built-in smartphone camera. For software, an occlusion-aware multi-sperm tracking algorithm was proposed to automatically measure sperm concentration and motility. In addition to intensively validating the proposed point-of-care method against clinical CASA systems, this work also analyzed different types of tracking failure and quantified their effects on the automated evaluation of sperm concentration and motility. The techniques pave the way for further improvement in both point-of-care and clinical semen analysis. Overall, this work offers an accessible and reliable tool for automated male fertility evaluation.
- Open Access
- 30 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 779
Modeling and Compensation of Positioning Error in Micromanipulation
In order to improve the positioning accuracy of the micromanipulation system, a comprehensive error model is first established to take into account the microscope nonlinear imaging distortion, camera installation error, and the mechanical displacement error of the motorized stage. A novel error compensation method is then proposed with distortion compensation coefficients obtained by the Levenberg–Marquardt optimization algorithm combined with the deduced nonlinear imaging model. The compensation coefficients for camera installation error and mechanical displacement error are derived from the rigid-body translation technique and image stitching algorithm. To validate the error compensation model, single shot and cumulative error tests were designed. The experimental results show that after the error compensation, the displacement errors were controlled within 0.25 μm when moving in a single direction and within 0.02 μm per 1000 μm when moving in multiple directions.
- 30 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 779
Open AccessModeling and Compensation of Positioning Error in Micromanipulation
In order to improve the positioning accuracy of the micromanipulation system, a comprehensive error model is first established to take into account the microscope nonlinear imaging distortion, camera installation error, and the mechanical displacement error of the motorized stage. A novel error compensation method is then proposed with distortion compensation coefficients obtained by the Levenberg–Marquardt optimization algorithm combined with the deduced nonlinear imaging model. The compensation coefficients for camera installation error and mechanical displacement error are derived from the rigid-body translation technique and image stitching algorithm. To validate the error compensation model, single shot and cumulative error tests were designed. The experimental results show that after the error compensation, the displacement errors were controlled within 0.25 μm when moving in a single direction and within 0.02 μm per 1000 μm when moving in multiple directions.
- Open Access
- 12 August 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (8) , 1301
Automated Denudation of Oocytes
Denudation is a technique for removal of the cumulus cell mass from oocytes in clinical intracytoplasmic sperm injection (ICSI). Manual oocyte denudation requires long training hours and stringent skills, but still suffers from low yield rate and denudation efficiency due to human fatigue and skill variations across operators. To address these limitations, this paper reports a robotic system for automated oocyte denudation. In this system, several key techniques are proposed, including a vision-based contact detection method for measuring the relative z position between the micropipette tip and the dish substrate, recognition of oocytes and the surrounding cumulus cells, automated calibration algorithm for eliminating the misalignment angle, and automated control of the flow rate based on the model of oocyte dynamics during micropipette aspiration and deposition. Experiments on mouse oocytes demonstrated that the robotic denudation system achieved a high yield rate of 97.0 ± 2.8% and denudation efficiency of 95.0 ± 0.8%. Additionally, oocytes denuded by the robotic system showed comparable fertilization rate and developmental competence compared with manual denudation. Our robotic denudation system represents one step towards the automation and standardization of ICSI procedures.
- 12 August 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (8) , 1301
Open AccessAutomated Denudation of Oocytes
Denudation is a technique for removal of the cumulus cell mass from oocytes in clinical intracytoplasmic sperm injection (ICSI). Manual oocyte denudation requires long training hours and stringent skills, but still suffers from low yield rate and denudation efficiency due to human fatigue and skill variations across operators. To address these limitations, this paper reports a robotic system for automated oocyte denudation. In this system, several key techniques are proposed, including a vision-based contact detection method for measuring the relative z position between the micropipette tip and the dish substrate, recognition of oocytes and the surrounding cumulus cells, automated calibration algorithm for eliminating the misalignment angle, and automated control of the flow rate based on the model of oocyte dynamics during micropipette aspiration and deposition. Experiments on mouse oocytes demonstrated that the robotic denudation system achieved a high yield rate of 97.0 ± 2.8% and denudation efficiency of 95.0 ± 0.8%. Additionally, oocytes denuded by the robotic system showed comparable fertilization rate and developmental competence compared with manual denudation. Our robotic denudation system represents one step towards the automation and standardization of ICSI procedures.
- Open Access
- 11 August 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (8) , 765
A Novel Stick-Slip Nanopositioning Stage Integrated with a Flexure Hinge-Based Friction Force Adjusting Structure
The piezoelectrically-actuated stick-slip nanopositioning stage (PASSNS) has been applied extensively, and many designs of PASSNSs have been developed. The friction force between the stick-slip surfaces plays a critical role in successful movement of the stage, which influences the load capacity, dynamic performance, and positioning accuracy of the PASSNS. Toward solving the influence problems of friction force, this paper presents a novel stick-slip nanopositioning stage where the flexure hinge-based friction force adjusting unit was employed. Numerical analysis was conducted to estimate the static performance of the stage, a dynamic model was established, and simulation analysis was performed to study the dynamic performance of the stage. Further, a prototype was manufactured and a series of experiments were carried out to test the performance of the stage. The results show that the maximum forward and backward movement speeds of the stage are 1 and 0.7 mm/s, respectively, and the minimum forward and backward step displacements are approximately 11 and 12 nm, respectively. Compared to the step displacement under no working load, the forward and backward step displacements only increase by 6% and 8% with a working load of 20 g, respectively. And the load capacity of the PASSNS in the vertical direction is about 72 g. The experimental results confirm the feasibility of the proposed stage, and high accuracy, high speed, and good robustness to varying loads were achieved. These results demonstrate the great potential of the developed stage in many nanopositioning applications.
- 11 August 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (8) , 765
Open AccessA Novel Stick-Slip Nanopositioning Stage Integrated with a Flexure Hinge-Based Friction Force Adjusting Structure
The piezoelectrically-actuated stick-slip nanopositioning stage (PASSNS) has been applied extensively, and many designs of PASSNSs have been developed. The friction force between the stick-slip surfaces plays a critical role in successful movement of the stage, which influences the load capacity, dynamic performance, and positioning accuracy of the PASSNS. Toward solving the influence problems of friction force, this paper presents a novel stick-slip nanopositioning stage where the flexure hinge-based friction force adjusting unit was employed. Numerical analysis was conducted to estimate the static performance of the stage, a dynamic model was established, and simulation analysis was performed to study the dynamic performance of the stage. Further, a prototype was manufactured and a series of experiments were carried out to test the performance of the stage. The results show that the maximum forward and backward movement speeds of the stage are 1 and 0.7 mm/s, respectively, and the minimum forward and backward step displacements are approximately 11 and 12 nm, respectively. Compared to the step displacement under no working load, the forward and backward step displacements only increase by 6% and 8% with a working load of 20 g, respectively. And the load capacity of the PASSNS in the vertical direction is about 72 g. The experimental results confirm the feasibility of the proposed stage, and high accuracy, high speed, and good robustness to varying loads were achieved. These results demonstrate the great potential of the developed stage in many nanopositioning applications.