Emily Kerr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Emily Kerr has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Paul Stewart Francis
School of Life and Environmental Sciences, Faculty of Science, Engineering and Built Environment, Deakin University, Waurn Ponds, Victoria 3216, Australia
15 shared publications - Conor Francis Hogan
The Biomedical and Environmental Sensor Technology (BEST) Research Centre, Biosensors Program, La Trobe Institute for Molecular Science (LIMS), La Trobe University, Melbourne, Victoria 3086, Australia
11 shared publications Egan H. Doeven
School of Life and Environmental Sciences, Faculty of Science, Engineering and Built Environment, Deakin University, Geelong, Victoria 3220, Australia
8 shared publications- Egan H. Doeven
Centre for Sustainable Bioproducts, Faculty of Science, Engineering and Built Environment Deakin University Geelong, Victoria 3220 Australia
6 shared publications - David J. D. Wilson
La Trobe University
5 shared publications - David J. Hayne
Institute for Frontier Materials, Deakin University, Geelong, Victoria 3220, Australia
5 shared publications
Latest Publications
- Open Access
- 19 December 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 15 (3) , 1150-1158
Redox-mediated electrochemiluminescence enhancement for bead-based immunoassay
Electrochemiluminescence (ECL) is a highly sensitive mode of detection utilised in commercialised bead-based immunoassays. Recently, the introduction of a freely diffusing water-soluble Ir(III) complex was demonstrated to enhance the ECL emission of [Ru(bpy)3]2+ labels anchored to microbeads, but a comprehensive investigation of the proposed ‘redox-mediated’ mechanism was not carried out. In this work, we select three different water-soluble Ir(III) complexes by virtue of their photophysical and electrochemical properties in comparison with those of the [Ru(bpy)3]2+ luminophore and the TPrA co-reactant. A systematic investigation of the influence of each Ir(III) complex on the emission of the Ru(II) labels on single beads by ECL microscopy revealed that the heterogeneous ECL can be finely tuned and either enhanced up to 107% or lowered by 75%. The variation of the [Ru(bpy)3]2+ ECL emission was correlated to the properties of each Ir(III)-based mediator, which enabled us to decipher the mechanism of interaction and define guidelines for the future design of novel Ir(III) complexes to further enhance the ECL emission of bead-based immunoassays. Ultimately, we showcase the potential of this technology for practical sample analysis in commercial instruments by assessing the enhancement of the collective ECL intensity from a bead-based system.
- 19 December 2023
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 15 (3) , 1150-1158
Open AccessRedox-mediated electrochemiluminescence enhancement for bead-based immunoassay
Electrochemiluminescence (ECL) is a highly sensitive mode of detection utilised in commercialised bead-based immunoassays. Recently, the introduction of a freely diffusing water-soluble Ir(III) complex was demonstrated to enhance the ECL emission of [Ru(bpy)3]2+ labels anchored to microbeads, but a comprehensive investigation of the proposed ‘redox-mediated’ mechanism was not carried out. In this work, we select three different water-soluble Ir(III) complexes by virtue of their photophysical and electrochemical properties in comparison with those of the [Ru(bpy)3]2+ luminophore and the TPrA co-reactant. A systematic investigation of the influence of each Ir(III) complex on the emission of the Ru(II) labels on single beads by ECL microscopy revealed that the heterogeneous ECL can be finely tuned and either enhanced up to 107% or lowered by 75%. The variation of the [Ru(bpy)3]2+ ECL emission was correlated to the properties of each Ir(III)-based mediator, which enabled us to decipher the mechanism of interaction and define guidelines for the future design of novel Ir(III) complexes to further enhance the ECL emission of bead-based immunoassays. Ultimately, we showcase the potential of this technology for practical sample analysis in commercial instruments by assessing the enhancement of the collective ECL intensity from a bead-based system.
- 26 January 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (2) , 933-939
Electrochemiluminescence Amplification in Bead-Based Assays Induced by a Freely Diffusing Iridium(III) Complex
Heterogeneous electrochemiluminescence (ECL) assays employing tri-n-propylamine as a co-reactant and a tris(2,2'-bipyridine)ruthenium(II) ([Ru(bpy)3]2+) derivative as an emissive label are integral to the majority of academic and commercial applications of ECL sensing. This model system is an active research area and constitutes the basis of successfully commercialized bead-based ECL immunoassays. Herein, we propose a novel approach to the enhancement of such conventional ECL assays via the incorporation of a second metal coordination complex, [Ir(sppy)3]3- (where sppy = 5'-sulfo-2-phenylpyridinato-C2,N), to the experimental system. By employing ECL microscopy, we are able to map the spatial distribution of ECL emission at the surface of the bead, from [Ru(bpy)3]2+ labels, and solution-phase emission, from [Ir(sppy)3]3-. The developed [Ir(sppy)3]3--mediated enhancement approach elicited a significant improvement (70.9-fold at 0.9 V and 2.9-fold at 1.2 V vs Ag/AgCl) of the ECL signal from [Ru(bpy)3]2+ labels immobilized on the surface of a polystyrene bead. This dramatic enhancement in ECL signal, particularly at low oxidation potentials, has important implications for the improvement of existing heterogeneous ECL assays and ECL-based microscopy, by amplifying the signal, opening new bioanalytical detection schemes, and reducing both electrode surface passivation and deleterious side reactions.
- 26 January 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (2) , 933-939
Electrochemiluminescence Amplification in Bead-Based Assays Induced by a Freely Diffusing Iridium(III) Complex
Heterogeneous electrochemiluminescence (ECL) assays employing tri-n-propylamine as a co-reactant and a tris(2,2'-bipyridine)ruthenium(II) ([Ru(bpy)3]2+) derivative as an emissive label are integral to the majority of academic and commercial applications of ECL sensing. This model system is an active research area and constitutes the basis of successfully commercialized bead-based ECL immunoassays. Herein, we propose a novel approach to the enhancement of such conventional ECL assays via the incorporation of a second metal coordination complex, [Ir(sppy)3]3- (where sppy = 5'-sulfo-2-phenylpyridinato-C2,N), to the experimental system. By employing ECL microscopy, we are able to map the spatial distribution of ECL emission at the surface of the bead, from [Ru(bpy)3]2+ labels, and solution-phase emission, from [Ir(sppy)3]3-. The developed [Ir(sppy)3]3--mediated enhancement approach elicited a significant improvement (70.9-fold at 0.9 V and 2.9-fold at 1.2 V vs Ag/AgCl) of the ECL signal from [Ru(bpy)3]2+ labels immobilized on the surface of a polystyrene bead. This dramatic enhancement in ECL signal, particularly at low oxidation potentials, has important implications for the improvement of existing heterogeneous ECL assays and ECL-based microscopy, by amplifying the signal, opening new bioanalytical detection schemes, and reducing both electrode surface passivation and deleterious side reactions.
- Open Access
- 15 December 2021
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 13 (2) , 469-477
A redox-mediator pathway for enhanced multi-colour electrochemiluminescence in aqueous solution
The classic and most widely used co-reactant electrochemiluminescence (ECL) reaction of tris(2,2′-bipyridine)ruthenium(II) ([Ru(bpy)3]2+) and tri-n-propylamine is enhanced by an order of magnitude by fac-[Ir(sppy)3]3− (where sppy = 5′-sulfo-2-phenylpyridinato-C2,N), through a novel ‘redox mediator’ pathway. Moreover, the concomitant green emission of [Ir(sppy)3]3−* enables internal standardisation of the co-reactant ECL of [Ru(bpy)3]2+. This can be applied using a digital camera as the photodetector by exploiting the ratio of R and B values of the RGB colour data, providing superior sensitivity and precision for the development of low-cost, portable ECL-based analytical devices.
- 15 December 2021
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 13 (2) , 469-477
Open AccessA redox-mediator pathway for enhanced multi-colour electrochemiluminescence in aqueous solution
The classic and most widely used co-reactant electrochemiluminescence (ECL) reaction of tris(2,2′-bipyridine)ruthenium(II) ([Ru(bpy)3]2+) and tri-n-propylamine is enhanced by an order of magnitude by fac-[Ir(sppy)3]3− (where sppy = 5′-sulfo-2-phenylpyridinato-C2,N), through a novel ‘redox mediator’ pathway. Moreover, the concomitant green emission of [Ir(sppy)3]3−* enables internal standardisation of the co-reactant ECL of [Ru(bpy)3]2+. This can be applied using a digital camera as the photodetector by exploiting the ratio of R and B values of the RGB colour data, providing superior sensitivity and precision for the development of low-cost, portable ECL-based analytical devices.
- Open Access
- 25 June 2021
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 12 (28) , 9770-9777
Emission from the working and counter electrodes under co-reactant electrochemiluminescence conditions
We present a new approach to explore the potential-dependent multi-colour co-reactant electrochemiluminescence (ECL) from multiple luminophores. The potentials at both the working and counter electrodes, the current between these electrodes, and the emission over cyclic voltammetric scans were simultaneously measured for the ECL reaction of Ir(ppy)3 and either [Ru(bpy)3]2+ or [Ir(df-ppy)2(ptb)]+, with tri-n-propylamine as the co-reactant. The counter electrode potential was monitored by adding a differential electrometer module to the potentiostat. Plotting the data against the applied working electrode potential and against time provided complementary depictions of their relationships. Photographs of the ECL at the surface of the two electrodes were taken to confirm the source of the emissions. This provided a new understanding of these multifaceted ECL systems, including the nature of the counter electrode potential and the possibility of eliciting ECL at this electrode, a mechanism-based rationalisation of the interactions of different metal-complex luminophores, and a previously unknown ECL pathway for the Ir(ppy)3 complex at negative potentials that was observed even in the absence of the co-reactant.
- 25 June 2021
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 12 (28) , 9770-9777
Open AccessEmission from the working and counter electrodes under co-reactant electrochemiluminescence conditions
We present a new approach to explore the potential-dependent multi-colour co-reactant electrochemiluminescence (ECL) from multiple luminophores. The potentials at both the working and counter electrodes, the current between these electrodes, and the emission over cyclic voltammetric scans were simultaneously measured for the ECL reaction of Ir(ppy)3 and either [Ru(bpy)3]2+ or [Ir(df-ppy)2(ptb)]+, with tri-n-propylamine as the co-reactant. The counter electrode potential was monitored by adding a differential electrometer module to the potentiostat. Plotting the data against the applied working electrode potential and against time provided complementary depictions of their relationships. Photographs of the ECL at the surface of the two electrodes were taken to confirm the source of the emissions. This provided a new understanding of these multifaceted ECL systems, including the nature of the counter electrode potential and the possibility of eliciting ECL at this electrode, a mechanism-based rationalisation of the interactions of different metal-complex luminophores, and a previously unknown ECL pathway for the Ir(ppy)3 complex at negative potentials that was observed even in the absence of the co-reactant.
- Open Access
- 28 January 2021
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 8
A Comparison of Commercially Available Screen-Printed Electrodes for Electrogenerated Chemiluminescence Applications
We examined a series of commercially available screen-printed electrodes (SPEs) for their suitability for electrochemical and electrogenerated chemiluminescence (ECL) detection systems. Using cyclic voltammetry with both a homogeneous solution-based and a heterogeneous bead-based ECL assay format, the most intense ECL signals were observed from unmodified carbon-based SPEs. Three commercially available varieties were tested, with Zensor outperforming DropSens and Kanichi in terms of sensitivity. The incorporation of nanomaterials in the electrode did not significantly enhance the ECL intensity under the conditions used in this evaluation (such as gold nanoparticles 19%, carbon nanotubes 45%, carbon nanofibers 21%, graphene 48%, and ordered mesoporous carbon 21% compared to the ECL intensity of unmodified Zensor carbon electrode). Platinum and gold SPEs exhibited poor relative ECL intensities (16% and 10%) when compared to carbonaceous materials, due to their high rates of surface oxide formation and inefficient oxidation of tri-n-propylamine (TPrA). However, the ECL signal at platinum electrodes can be increased ∼3-fold with the addition of a surfactant, which enhanced TPrA oxidation due to increasing the hydrophobicity of the electrode surface. Our results also demonstrate that each SPE should only be used once, as we observed a significant change in ECL intensity over repeated CV scans and SPEs cannot be mechanically polished to refresh the electrode surface.
- 28 January 2021
- Published by Frontiers Media SA in Frontiers in Chemistry
- Vol. 8
Open AccessA Comparison of Commercially Available Screen-Printed Electrodes for Electrogenerated Chemiluminescence Applications
We examined a series of commercially available screen-printed electrodes (SPEs) for their suitability for electrochemical and electrogenerated chemiluminescence (ECL) detection systems. Using cyclic voltammetry with both a homogeneous solution-based and a heterogeneous bead-based ECL assay format, the most intense ECL signals were observed from unmodified carbon-based SPEs. Three commercially available varieties were tested, with Zensor outperforming DropSens and Kanichi in terms of sensitivity. The incorporation of nanomaterials in the electrode did not significantly enhance the ECL intensity under the conditions used in this evaluation (such as gold nanoparticles 19%, carbon nanotubes 45%, carbon nanofibers 21%, graphene 48%, and ordered mesoporous carbon 21% compared to the ECL intensity of unmodified Zensor carbon electrode). Platinum and gold SPEs exhibited poor relative ECL intensities (16% and 10%) when compared to carbonaceous materials, due to their high rates of surface oxide formation and inefficient oxidation of tri-n-propylamine (TPrA). However, the ECL signal at platinum electrodes can be increased ∼3-fold with the addition of a surfactant, which enhanced TPrA oxidation due to increasing the hydrophobicity of the electrode surface. Our results also demonstrate that each SPE should only be used once, as we observed a significant change in ECL intensity over repeated CV scans and SPEs cannot be mechanically polished to refresh the electrode surface.
- 23 July 2020
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 56 (69) , 10022-10025
Cathodic electrogenerated chemiluminescence of tris(2,2′-bipyridine)ruthenium(ii) and peroxydisulfate at pure Ti3C2Tx MXene electrodes
Two-dimensional transition metal carbide (Ti3C2Tx MXene) film as a novel electrode material for electrogenerated chemiluminescence of tris(2,2′-bipyridine)ruthenium(ii) and peroxydisulfate.
- 23 July 2020
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 56 (69) , 10022-10025
Cathodic electrogenerated chemiluminescence of tris(2,2′-bipyridine)ruthenium(ii) and peroxydisulfate at pure Ti3C2Tx MXene electrodes
Two-dimensional transition metal carbide (Ti3C2Tx MXene) film as a novel electrode material for electrogenerated chemiluminescence of tris(2,2′-bipyridine)ruthenium(ii) and peroxydisulfate.
- 4 July 2018
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 20 (28) , 18995-19006
Mixed annihilation electrogenerated chemiluminescence of iridium(iii) complexes
Previously reported annihilation ECL of mixtures of metal complexes have generally comprised Ir(ppy)3 or a close analogue as a higher energy donor/emitter (green/blue light) and [Ru(bpy)3]2+ or its derivative as a lower energy acceptor/emitter (red light). In contrast, here we examine Ir(ppy)3 as the lower energy acceptor/emitter, by combining it with a second Ir(III) complex: [Ir(df-ppy)2(ptb)]+ (where ptb = 1-benzyl-1,2,3-triazol-4-ylpyridine). The application of potentials sufficient to attain the first single-electron oxidation and reduction products can be exploited to detect Ir(ppy)3 at orders of magnitude lower concentration, or enhance its maximum emission intensity at high concentration far beyond that achievable through conventional annihilation ECL of Ir(ppy)3 involving comproportionation. Moreover, under certain conditions, the colour of the emission can be selected through the applied electrochemical potentials. We have also prepared a novel Ir(III) complex with a sufficiently low reduction potential that the reaction between its reduced form and Ir(ppy)3 + cannot populate the excited state of either luminophore. This enabled, for the first time, the exclusive formation of either excited state through the application of higher cathodic or anodic potentials, but in both cases, the ECL was greatly diminished by parasitic dark reactions.
- 4 July 2018
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 20 (28) , 18995-19006
Mixed annihilation electrogenerated chemiluminescence of iridium(iii) complexes
Previously reported annihilation ECL of mixtures of metal complexes have generally comprised Ir(ppy)3 or a close analogue as a higher energy donor/emitter (green/blue light) and [Ru(bpy)3]2+ or its derivative as a lower energy acceptor/emitter (red light). In contrast, here we examine Ir(ppy)3 as the lower energy acceptor/emitter, by combining it with a second Ir(III) complex: [Ir(df-ppy)2(ptb)]+ (where ptb = 1-benzyl-1,2,3-triazol-4-ylpyridine). The application of potentials sufficient to attain the first single-electron oxidation and reduction products can be exploited to detect Ir(ppy)3 at orders of magnitude lower concentration, or enhance its maximum emission intensity at high concentration far beyond that achievable through conventional annihilation ECL of Ir(ppy)3 involving comproportionation. Moreover, under certain conditions, the colour of the emission can be selected through the applied electrochemical potentials. We have also prepared a novel Ir(III) complex with a sufficiently low reduction potential that the reaction between its reduced form and Ir(ppy)3 + cannot populate the excited state of either luminophore. This enabled, for the first time, the exclusive formation of either excited state through the application of higher cathodic or anodic potentials, but in both cases, the ECL was greatly diminished by parasitic dark reactions.
- 8 May 2018
- Published by Wiley in ChemElectroChem
- Vol. 5 (12) , 1543-1547
Electrochemically, Spectrally, and Spatially Resolved Annihilation‐Electrogenerated Chemiluminescence of Mixed‐Metal Complexes at Working and Counter Electrodes
Previously dismissed as an unwanted and unpredictable artifact of electrogenerated chemiluminescence (ECL) systems, emission at the counter electrode has new importance in the context of the emerging multicolor and potential‐resolved ECL systems in which a much wider range of potentials are applied at the working electrode. Herein, we explore the annihilation ECL from a mixture of two electrochemiluminophores at both the working and counter electrodes of a three‐electrode electrochemical cell. The potentials at the working and counter electrodes were both measured, and the simultaneous spatially resolved ECL was captured with a digital camera. The factors that determine the dominant emitter (and therefore the observed emission color) at the working electrode can be applied to the counter, albeit with a less well‐defined potential range. A variety of color combinations from the luminophores can be elicited at the two electrode surfaces through the selection of applied potentials.
- 8 May 2018
- Published by Wiley in ChemElectroChem
- Vol. 5 (12) , 1543-1547
Electrochemically, Spectrally, and Spatially Resolved Annihilation‐Electrogenerated Chemiluminescence of Mixed‐Metal Complexes at Working and Counter Electrodes
Previously dismissed as an unwanted and unpredictable artifact of electrogenerated chemiluminescence (ECL) systems, emission at the counter electrode has new importance in the context of the emerging multicolor and potential‐resolved ECL systems in which a much wider range of potentials are applied at the working electrode. Herein, we explore the annihilation ECL from a mixture of two electrochemiluminophores at both the working and counter electrodes of a three‐electrode electrochemical cell. The potentials at the working and counter electrodes were both measured, and the simultaneous spatially resolved ECL was captured with a digital camera. The factors that determine the dominant emitter (and therefore the observed emission color) at the working electrode can be applied to the counter, albeit with a less well‐defined potential range. A variety of color combinations from the luminophores can be elicited at the two electrode surfaces through the selection of applied potentials.
- 3 May 2017
- Published by Wiley in ChemElectroChem
- Vol. 4 (7) , 1797-1808
Co‐reactant Electrogenerated Chemiluminescence of Iridium(III) Complexes Containing an Acetylacetonate Ligand
We examine the electrogenerated chemiluminescence (ECL) of three Ir( )2(acac) complexes, where acac=acetylacetonate anion and =2‐phenylpyridine (ppy), 2‐phenylbenzothiazole (bt), or 2‐phenylquinoline (pq) anions, with tri‐n‐propylamine co‐reactant in acetonitrile under a range of chemical and instrumental conditions; this follows somewhat conflicting recent claims of the ECL intensities from complexes of this type. Relevant electrochemical, spectroscopic, and ECL properties are evaluated in direct comparison with those of Ir(ppy)3 and [Ru(bpy)3](PF6)2, as well as data from previous publications. DFT calculations on the Ir( )2(acac) complexes show the HOMOs to be composed of both the metal and the ligand, and the LUMOs almost exclusively on the ligand. The ECL intensities of the Ir( )2(acac) complexes (relative to [Ru(bpy)3](PF6)2) were dependent on experimental conditions and, in some cases, the ECL intensities reported for iridium complexes may have been derived using conditions that unintentionally disadvantaged the reference electrochemiluminophore.
- 3 May 2017
- Published by Wiley in ChemElectroChem
- Vol. 4 (7) , 1797-1808
Co‐reactant Electrogenerated Chemiluminescence of Iridium(III) Complexes Containing an Acetylacetonate Ligand
We examine the electrogenerated chemiluminescence (ECL) of three Ir( )2(acac) complexes, where acac=acetylacetonate anion and =2‐phenylpyridine (ppy), 2‐phenylbenzothiazole (bt), or 2‐phenylquinoline (pq) anions, with tri‐n‐propylamine co‐reactant in acetonitrile under a range of chemical and instrumental conditions; this follows somewhat conflicting recent claims of the ECL intensities from complexes of this type. Relevant electrochemical, spectroscopic, and ECL properties are evaluated in direct comparison with those of Ir(ppy)3 and [Ru(bpy)3](PF6)2, as well as data from previous publications. DFT calculations on the Ir( )2(acac) complexes show the HOMOs to be composed of both the metal and the ligand, and the LUMOs almost exclusively on the ligand. The ECL intensities of the Ir( )2(acac) complexes (relative to [Ru(bpy)3](PF6)2) were dependent on experimental conditions and, in some cases, the ECL intensities reported for iridium complexes may have been derived using conditions that unintentionally disadvantaged the reference electrochemiluminophore.
- 19 September 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (20) , 3885-3897
Coated and uncoated cellophane as materials for microplates and open-channel microfluidics devices
This communication describes the use of uncoated cellophane (regenerated cellulose films) for the fabrication of microplates, and the use of coated cellophane for the fabrication of open-channel microfluidic devices.
- 19 September 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (20) , 3885-3897
Coated and uncoated cellophane as materials for microplates and open-channel microfluidics devices
This communication describes the use of uncoated cellophane (regenerated cellulose films) for the fabrication of microplates, and the use of coated cellophane for the fabrication of open-channel microfluidic devices.