He Kong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
He Kong has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Ancheng Xue
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
5 shared publications - Feiyang Xu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing, 102206 China
4 shared publications - Guoen Wei
Guangzhou Power Supply Bureau, Guangdong Power Grid Ltd., Guangzhou, 510000, China
2 shared publications Jinzhou Yang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
2 shared publications- Lei Gu
State Grid Jiangsu Corporation of China, Suzhou, China
2 shared publications - Li Wang
Guangzhou Power Supply Bureau, Guangdong Power Grid Ltd., Guangzhou, 510000, China
2 shared publications
Latest Publications
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Correction Method for Deviations in Phase Angle for PMUs at Both Ends of a Transmission Line With Unknown Parameters
The phasor measurement units (PMUs) are the eyes for the dynamic of the power system. However, the measured phase angle data from PMUs for a transmission line (TL) may coexist with different deviations, i.e., the deviations in voltage/current phase angle difference (DVPAD/DCPAD) between different ends of the TL, and the deviations in power factor angle (DPFA, i.e., the deviations in phase angle difference between voltage and current at the same end), which threaten the advanced application with PMUs. This article proposes a correction method for the phase angle data when the DVPAD/DCPAD and DPFA coexist for the TL with unknown line parameters. Specifically, first, the abnormal voltage phase angle differences and power factor angle anomalies are discussed, and the corresponding illustrative examples are presented. Second, the mathematical model for estimating phase angle deviations in a general case is presented. Third, a “two-step” method to correct the phase angle data of PMU for the TLs with unknown parameters is proposed, in which the DVPAD/DCPAD between two ends is estimated in advance, and then, the DPFA is estimated. Finally, simulation and examples with field data verify the feasibility and engineering applicability of the proposed method.
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Correction Method for Deviations in Phase Angle for PMUs at Both Ends of a Transmission Line With Unknown Parameters
The phasor measurement units (PMUs) are the eyes for the dynamic of the power system. However, the measured phase angle data from PMUs for a transmission line (TL) may coexist with different deviations, i.e., the deviations in voltage/current phase angle difference (DVPAD/DCPAD) between different ends of the TL, and the deviations in power factor angle (DPFA, i.e., the deviations in phase angle difference between voltage and current at the same end), which threaten the advanced application with PMUs. This article proposes a correction method for the phase angle data when the DVPAD/DCPAD and DPFA coexist for the TL with unknown line parameters. Specifically, first, the abnormal voltage phase angle differences and power factor angle anomalies are discussed, and the corresponding illustrative examples are presented. Second, the mathematical model for estimating phase angle deviations in a general case is presented. Third, a “two-step” method to correct the phase angle data of PMU for the TLs with unknown parameters is proposed, in which the DVPAD/DCPAD between two ends is estimated in advance, and then, the DPFA is estimated. Finally, simulation and examples with field data verify the feasibility and engineering applicability of the proposed method.
- 14 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (3) , 1807-1815
Detection and Correction of PMU Angle Deviation for Double-Circuit Line Using Reactive Power Measurements
Errors in voltage and current transformer and compensation algorithms may cause errors in local voltage and current phase angle measured by phasor measurement units (PMU), whose difference is defined as the power factor angle (PFA). Consequently, the error of local PMU voltage and current phase angle difference, i.e., power factor angle deviation (PFAD), can cause reactive power measurement deviation, which leads to reactive power measurement inconsistency of symmetrical double-circuit lines, deteriorating the application of dynamic monitoring. In this paper, a three-step correction method for PFAD of double-circuit lines is proposed based on the operation characteristics and reactive power of double-circuit lines:1) estimate the difference between PFADs of different lines at the same end; 2) estimate the difference of PFADs at both ends of one line of the double-circuit lines; 3) estimate the local PFAD. The method does not require line parameters and can realize the correction of PFAD at each end of the double circuit line. Finally, the effectiveness and robustness of the proposed method are demonstrated by the simulation results using both simulated and field data.
- 14 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (3) , 1807-1815
Detection and Correction of PMU Angle Deviation for Double-Circuit Line Using Reactive Power Measurements
Errors in voltage and current transformer and compensation algorithms may cause errors in local voltage and current phase angle measured by phasor measurement units (PMU), whose difference is defined as the power factor angle (PFA). Consequently, the error of local PMU voltage and current phase angle difference, i.e., power factor angle deviation (PFAD), can cause reactive power measurement deviation, which leads to reactive power measurement inconsistency of symmetrical double-circuit lines, deteriorating the application of dynamic monitoring. In this paper, a three-step correction method for PFAD of double-circuit lines is proposed based on the operation characteristics and reactive power of double-circuit lines:1) estimate the difference between PFADs of different lines at the same end; 2) estimate the difference of PFADs at both ends of one line of the double-circuit lines; 3) estimate the local PFAD. The method does not require line parameters and can realize the correction of PFAD at each end of the double circuit line. Finally, the effectiveness and robustness of the proposed method are demonstrated by the simulation results using both simulated and field data.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 71 (4) , 2439-2443
Bifurcation Analysis and Criterion of Voltage Oscillation Induced by Low Voltage Ride Through Control in Renewable Energy Stations
The voltage stability issue of renewable energy stations (RES) cannot be ignored. In this paper, for the Voltage Oscillation Instability phenomenon caused by the Low voltage ride through during High active power output of the RES with No faults (VOILHN), works on both theory and criterion are conducted. In theory, it is explained that the VOI-LHN corresponds to a High active power output and Low voltage ride through control induced Non-smooth Bifurcation (HLINB). Furthermore, based on theoretical derivation and actual power grid parameters, the boundary between HLINB and Saddle Node Bifurcation (SNB) is obtained. The boundary suggests that in actual power grids, wind farms are more prone to HLINB than SNB. In criterion, a criterion for the occurrence of HLINB is developed, and a threshold calculation method for the criterion is proposed.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 71 (4) , 2439-2443
Bifurcation Analysis and Criterion of Voltage Oscillation Induced by Low Voltage Ride Through Control in Renewable Energy Stations
The voltage stability issue of renewable energy stations (RES) cannot be ignored. In this paper, for the Voltage Oscillation Instability phenomenon caused by the Low voltage ride through during High active power output of the RES with No faults (VOILHN), works on both theory and criterion are conducted. In theory, it is explained that the VOI-LHN corresponds to a High active power output and Low voltage ride through control induced Non-smooth Bifurcation (HLINB). Furthermore, based on theoretical derivation and actual power grid parameters, the boundary between HLINB and Saddle Node Bifurcation (SNB) is obtained. The boundary suggests that in actual power grids, wind farms are more prone to HLINB than SNB. In criterion, a criterion for the occurrence of HLINB is developed, and a threshold calculation method for the criterion is proposed.
- Open Access
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 176122-176133
Characteristics of PMU Phase Angle Difference Induced by Frequency Deviation of Crystal Oscillator and its Detection Method
Phasor measurement unit (PMU), which could provide high-frequency phasors including the amplitude and phase angle synchronized with Global Positioning System (GPS)/BeiDou Navigation Satellite System (BDS) signal, plays a vital role in dynamic monitoring of power systems. However, if the GPS/BDS signal could not be received, the time of PMU, which depends on the crystal oscillator (CO), would cause measurement deviation due to frequency shifts of CO, and then the PMU data would engage deviations and deteriorate the relevant applications. In recognizing the above problems, this paper proposes a method to detect the frequency deviation of the crystal oscillator (FDCO) based on the correlation coefficient, according to its relation with the characteristic of the voltage phase angle difference(VPAD) between the two ends of the line. In detail, firstly, the quality of the VPAD of PMU between the two ends of the line is analyzed and the related problem is stated. Secondly, the characteristics of PMU data, when FDCO exists, are derived and analyzed, especially the VPAD between the line, and the suitability of the data for detecting the FDCO is discussed. Thirdly, the ideas and specific methods of detecting the FDCO in case of malfunction of GPS/BDS signal are proposed. Furthermore, the validity of the proposed method with simulation data and modified measured data is presented. Finally, the conjectures on the reasons for the approximately constant VPAD deviation in the previous section are discussed.
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 176122-176133
Open AccessCharacteristics of PMU Phase Angle Difference Induced by Frequency Deviation of Crystal Oscillator and its Detection Method
Phasor measurement unit (PMU), which could provide high-frequency phasors including the amplitude and phase angle synchronized with Global Positioning System (GPS)/BeiDou Navigation Satellite System (BDS) signal, plays a vital role in dynamic monitoring of power systems. However, if the GPS/BDS signal could not be received, the time of PMU, which depends on the crystal oscillator (CO), would cause measurement deviation due to frequency shifts of CO, and then the PMU data would engage deviations and deteriorate the relevant applications. In recognizing the above problems, this paper proposes a method to detect the frequency deviation of the crystal oscillator (FDCO) based on the correlation coefficient, according to its relation with the characteristic of the voltage phase angle difference(VPAD) between the two ends of the line. In detail, firstly, the quality of the VPAD of PMU between the two ends of the line is analyzed and the related problem is stated. Secondly, the characteristics of PMU data, when FDCO exists, are derived and analyzed, especially the VPAD between the line, and the suitability of the data for detecting the FDCO is discussed. Thirdly, the ideas and specific methods of detecting the FDCO in case of malfunction of GPS/BDS signal are proposed. Furthermore, the validity of the proposed method with simulation data and modified measured data is presented. Finally, the conjectures on the reasons for the approximately constant VPAD deviation in the previous section are discussed.
- Open Access
- 20 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 132960-132969
A New Robust Identification Method for Transmission Line Parameters Based on ADALINE and IGG Method
Accurate transmission line parameters are the basis of power system calculations. Aiming at obtaining accuracy online transmission line parameters in the case of large random noises even bad data in Phasor Measurement Unit (PMU) measurements, which occurs frequently in the practice, a new adaptive robust identification method combining adaptive linear neuron (ADALINE) and traditional robust IGG (Institute of Geodesy & Geophysics, Chinese Academy of Sciences) method is proposed. In detail, first, the identification model of transmission line parameters is presented based on the multi-period PMU measurements at both ends of the transmission line. Then, a parameter solving model based on ADALINE is established. Furthermore, to fully use measurement information, the adaptive robust ADALINE (ARA) are proposed, which applies the robust IGG weight function (Scheme I) to ADALINE to realize “three segments” robust identification. In addition, to improve the robustness, the expectation and variance of the equation residual sequence are estimated adaptively with the median principle to adjust the threshold for the IGG function to assure robustness (TAR), which is independent of the known information for the error of the measurement equipment. The cases based on PSCAD simulated data and measured data show the effectiveness and engineering practicality of the proposed method.
- 20 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 132960-132969
Open AccessA New Robust Identification Method for Transmission Line Parameters Based on ADALINE and IGG Method
Accurate transmission line parameters are the basis of power system calculations. Aiming at obtaining accuracy online transmission line parameters in the case of large random noises even bad data in Phasor Measurement Unit (PMU) measurements, which occurs frequently in the practice, a new adaptive robust identification method combining adaptive linear neuron (ADALINE) and traditional robust IGG (Institute of Geodesy & Geophysics, Chinese Academy of Sciences) method is proposed. In detail, first, the identification model of transmission line parameters is presented based on the multi-period PMU measurements at both ends of the transmission line. Then, a parameter solving model based on ADALINE is established. Furthermore, to fully use measurement information, the adaptive robust ADALINE (ARA) are proposed, which applies the robust IGG weight function (Scheme I) to ADALINE to realize “three segments” robust identification. In addition, to improve the robustness, the expectation and variance of the equation residual sequence are estimated adaptively with the median principle to adjust the threshold for the IGG function to assure robustness (TAR), which is independent of the known information for the error of the measurement equipment. The cases based on PSCAD simulated data and measured data show the effectiveness and engineering practicality of the proposed method.