Zhiqing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhiqing Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Quanming Luo
Chongqing University
6 shared publications - Yuqi Wei
Xi’an Jiaotong University
6 shared publications - Homer Alan Mantooth
University of Arkansas
4 shared publications - Di Mou
Department of Electrical Engineering, Tsinghua University, Beijing, China
3 shared publications - Jia Li
School of Automation, Chongqing University of Posts and Telecommunications, Chongqing, China
2 shared publications - Pengju Sun
Chongqing University
2 shared publications
Latest Publications
- Open Access
- 19 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Industry Applications
- Vol. 2, 320-336
MATLAB GUI Based Steady State Open-Loop and Closed-Loop Simulation Tools for Different LLC Converters With all Operation Modes
LLC resonant converters have been widely adopted in many different industrial applications due to their characteristics of high efficiency and high power density. Simulation tools are of great importance for the analysis and design of LLC resonant converters. For example, many LLC design methods require massive simulations to finalize the circuit parameters, iterations are necessary, which can be tedious and time-consuming. Therefore, in this work, accurate and complete steady state simulation tools based on MATLAB graphical user interface (GUI) are designed for LLC resonant converters. All common and possible operation modes and LLC converter topologies are included in the designed simulation tools, which makes them practical for different applications and operation conditions. An improved mode judgement method and guidelines for initial point setting are proposed to ensure fast simulation speed. More than that, the key circuit voltage and current values are summarized for the user to evaluate the converter performance, which is more convenient than commercial simulation software. Moreover, the designed simulation tools are suitable and convenient for automatic converter parameter design.
- 19 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Industry Applications
- Vol. 2, 320-336
Open AccessMATLAB GUI Based Steady State Open-Loop and Closed-Loop Simulation Tools for Different LLC Converters With all Operation Modes
LLC resonant converters have been widely adopted in many different industrial applications due to their characteristics of high efficiency and high power density. Simulation tools are of great importance for the analysis and design of LLC resonant converters. For example, many LLC design methods require massive simulations to finalize the circuit parameters, iterations are necessary, which can be tedious and time-consuming. Therefore, in this work, accurate and complete steady state simulation tools based on MATLAB graphical user interface (GUI) are designed for LLC resonant converters. All common and possible operation modes and LLC converter topologies are included in the designed simulation tools, which makes them practical for different applications and operation conditions. An improved mode judgement method and guidelines for initial point setting are proposed to ensure fast simulation speed. More than that, the key circuit voltage and current values are summarized for the user to evaluate the converter performance, which is more convenient than commercial simulation software. Moreover, the designed simulation tools are suitable and convenient for automatic converter parameter design.
- 9 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (2) , 1548-1562
Simple and Effective Adaptive Deadtime Strategies for LLC Resonant Converter: Analysis, Design, and Implementation
Deadtime is a critical design target for soft switching dc/dc converters. On the one hand, the deadtime is necessary to ensure the safety operation of the devices in one switching leg; on the other hand, enough deadtime is required to achieve zero voltage switching (ZVS) operation. Due to the complexity of LLC converters, traditionally, the deadtime selection is either based on engineering experience or inaccurate analysis of the converter, which leads to an unoptimized deadtime. Specifically, a large deadtime will lead to efficiency degradation due to the body diode conduction during deadtime. The ZVS operation cannot be completely achieved with a small deadtime, which will also degrade the converter efficiency. Therefore, there is a demand for an accurate analysis of the deadtime effect on LLC converters. In this article, an accurate and in-depth analysis of the deadtime effect on the LLC converter is performed with the aid of the time-domain analysis (TDA). However, the proposed adaptive deadtime strategies can also be implemented based on the experiment or simulation results for those who do not have access to the TDA of LLC converters. Based on the analysis, novel adaptive deadtime strategies are proposed for the LLC converter. Compared with the traditional fixed deadtime strategy, around 1% efficiency improvement is achieved for a 125-W experimental prototype during the whole operating range.
- 9 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (2) , 1548-1562
Simple and Effective Adaptive Deadtime Strategies for LLC Resonant Converter: Analysis, Design, and Implementation
Deadtime is a critical design target for soft switching dc/dc converters. On the one hand, the deadtime is necessary to ensure the safety operation of the devices in one switching leg; on the other hand, enough deadtime is required to achieve zero voltage switching (ZVS) operation. Due to the complexity of LLC converters, traditionally, the deadtime selection is either based on engineering experience or inaccurate analysis of the converter, which leads to an unoptimized deadtime. Specifically, a large deadtime will lead to efficiency degradation due to the body diode conduction during deadtime. The ZVS operation cannot be completely achieved with a small deadtime, which will also degrade the converter efficiency. Therefore, there is a demand for an accurate analysis of the deadtime effect on LLC converters. In this article, an accurate and in-depth analysis of the deadtime effect on the LLC converter is performed with the aid of the time-domain analysis (TDA). However, the proposed adaptive deadtime strategies can also be implemented based on the experiment or simulation results for those who do not have access to the TDA of LLC converters. Based on the analysis, novel adaptive deadtime strategies are proposed for the LLC converter. Compared with the traditional fixed deadtime strategy, around 1% efficiency improvement is achieved for a 125-W experimental prototype during the whole operating range.
- 18 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4572-4584
Optimal Asymmetric Duty Modulation to Minimize Inductor Peak-to-Peak Current for Dual Active Bridge DC–DC Converter
Asymmetric duty modulation (ADM), as a recently proposed modulation scheme, provides new chance to improve the performance of dual active bridge (DAB) converter. On this basis, an optimal asymmetric duty modulation (OADM) scheme is proposed in this paper to minimize the inductor peak-to-peak current over the whole voltage and power range. Firstly, the DAB converter adopting ADM scheme is analyzed in frequency-domain and time-domain, and four operating modes are established. Then, the minimum peak-to-peak inductor current for each operating mode is obtained under Karush—Kuhn—Tucker (KKT) condition, and the corresponding optimal closed-loop control with low calculation complexity is derived. Then, the key values and features of the OADM scheme are compared with recent state-of-the-art, mainly including the inductor root mean square (RMS) current and soft-switching performance. Finally, an experimental prototype was built to validate the efficiency enhancement of the converter by adopting the proposed OADM scheme.
- 18 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4572-4584
Optimal Asymmetric Duty Modulation to Minimize Inductor Peak-to-Peak Current for Dual Active Bridge DC–DC Converter
Asymmetric duty modulation (ADM), as a recently proposed modulation scheme, provides new chance to improve the performance of dual active bridge (DAB) converter. On this basis, an optimal asymmetric duty modulation (OADM) scheme is proposed in this paper to minimize the inductor peak-to-peak current over the whole voltage and power range. Firstly, the DAB converter adopting ADM scheme is analyzed in frequency-domain and time-domain, and four operating modes are established. Then, the minimum peak-to-peak inductor current for each operating mode is obtained under Karush—Kuhn—Tucker (KKT) condition, and the corresponding optimal closed-loop control with low calculation complexity is derived. Then, the key values and features of the OADM scheme are compared with recent state-of-the-art, mainly including the inductor root mean square (RMS) current and soft-switching performance. Finally, an experimental prototype was built to validate the efficiency enhancement of the converter by adopting the proposed OADM scheme.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4738-4751
Hybrid Duty Modulation for Dual Active Bridge Converter to Minimize RMS Current and Extend Soft-Switching Range Using the Frequency Domain Analysis
In this paper, an efficiency-oriented hybrid duty modulation (HDM) scheme is proposed for the dual active bridge (DAB) converter that can reduce the inductor root-mean-square (RMS) current and extend the switch soft-switching range. Firstly, a complete description of the combination forms of different modulation schemes is presented with the consideration of the allocation of the zero-voltage portion. A unified description for these combination forms is obtained in the frequency domain. Secondly, the symmetric-symmetric duty modulation (SSDM) scheme and asymmetric-symmetric duty modulation (A2SDM) scheme are established to minimize the inductor RMS current by considering its fundamental component. Thirdly, the characteristi-cs of SSDM, A2SDM and the traditional phase shift modulation (PSM) schemes are compared from several aspects, mainly including the inductor RMS current and the soft-switching performance. Furthermore, the loss breakdown analysis results for the three modulation schemes are presented and compared. According to these results, the HDM scheme is proposed to improve the overall efficiency of the DAB converter. Finally, an experimental prototype was built with a peak efficiency of 97%, which validates and effectiveness of the proposed modulation scheme.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4738-4751
Hybrid Duty Modulation for Dual Active Bridge Converter to Minimize RMS Current and Extend Soft-Switching Range Using the Frequency Domain Analysis
In this paper, an efficiency-oriented hybrid duty modulation (HDM) scheme is proposed for the dual active bridge (DAB) converter that can reduce the inductor root-mean-square (RMS) current and extend the switch soft-switching range. Firstly, a complete description of the combination forms of different modulation schemes is presented with the consideration of the allocation of the zero-voltage portion. A unified description for these combination forms is obtained in the frequency domain. Secondly, the symmetric-symmetric duty modulation (SSDM) scheme and asymmetric-symmetric duty modulation (A2SDM) scheme are established to minimize the inductor RMS current by considering its fundamental component. Thirdly, the characteristi-cs of SSDM, A2SDM and the traditional phase shift modulation (PSM) schemes are compared from several aspects, mainly including the inductor RMS current and the soft-switching performance. Furthermore, the loss breakdown analysis results for the three modulation schemes are presented and compared. According to these results, the HDM scheme is proposed to improve the overall efficiency of the DAB converter. Finally, an experimental prototype was built with a peak efficiency of 97%, which validates and effectiveness of the proposed modulation scheme.
- 7 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 3674-3691
A Complete Step-by-Step Optimal Design for LLC Resonant Converter
LLC resonant converters have been widely used in many different industrial applications. Analysis and design methodologies have great effect on the converter performance. Accordingly, a complete step by step optimal design methodology based on time domain analysis has been proposed for LLC resonant converter in this paper. The proposed design methodology is implemented under the worst operation condition, and the following considerations are included to obtain the suitable design area: 1) operation mode; 2) voltage stress for resonant capacitor; 3) zero voltage switching (ZVS) operation for primary switches; 4) resonant tank root-mean-square (RMS) current. Then, by finding all possible design candidates and comparing among them based on the power loss model, the optimized design candidate can be found. Compared with the existing design methodologies, the proposed one has the advantages of high accuracy and small computation requirement, which makes it application in industry possible. Finally, a 192 W experimental prototype was built to validate the effectiveness of the proposed design methodology. In addition, a MATLAB graphical user interference (GUI) program was built based on the proposed design methodology to visualize and facilitate the design process for engineers.
- 7 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 3674-3691
A Complete Step-by-Step Optimal Design for LLC Resonant Converter
LLC resonant converters have been widely used in many different industrial applications. Analysis and design methodologies have great effect on the converter performance. Accordingly, a complete step by step optimal design methodology based on time domain analysis has been proposed for LLC resonant converter in this paper. The proposed design methodology is implemented under the worst operation condition, and the following considerations are included to obtain the suitable design area: 1) operation mode; 2) voltage stress for resonant capacitor; 3) zero voltage switching (ZVS) operation for primary switches; 4) resonant tank root-mean-square (RMS) current. Then, by finding all possible design candidates and comparing among them based on the power loss model, the optimized design candidate can be found. Compared with the existing design methodologies, the proposed one has the advantages of high accuracy and small computation requirement, which makes it application in industry possible. Finally, a 192 W experimental prototype was built to validate the effectiveness of the proposed design methodology. In addition, a MATLAB graphical user interference (GUI) program was built based on the proposed design methodology to visualize and facilitate the design process for engineers.
- Top Cited Papers
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (11) , 11783-11800
Topology Analysis and Review of Three-Port DC–DC Converters
In order to realize power flow control among photovoltaic (PV) panel port, battery port, and load port in the distributed photovoltaic power generation system, integrated three-port DC/DC converters (TPCs) are widely adopted. The objective of this paper is to provide a comprehensive, comparative, and insightful analysis and overview of these TPCs. Firstly, based on the power transmission and control requirements of the system, five topological structures of a three-port DC/DC conversion system (TPCS) composed of two or three two-port DC/DC converters are presented. And the five structures are comparatively analyzed. Secondly, based on these topological structures, and combing with the basic two-port DC/DC converters, three groups of typical TPCs with different galvanic isolation requirements are derived respectively by sharing switches, combining branches, etc. And comprehensive analysis, comparisons, and reviews of these TPCs with different structures of each isolation type are presented with tables and figures. Finally, the comparison results of the three isolation groups are summarized, which leads to a guidance for the selection of TPCs in different applications, and then some suggestions for the future research on TPCs are given.
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (11) , 11783-11800
Top Cited PapersTopology Analysis and Review of Three-Port DC–DC Converters
In order to realize power flow control among photovoltaic (PV) panel port, battery port, and load port in the distributed photovoltaic power generation system, integrated three-port DC/DC converters (TPCs) are widely adopted. The objective of this paper is to provide a comprehensive, comparative, and insightful analysis and overview of these TPCs. Firstly, based on the power transmission and control requirements of the system, five topological structures of a three-port DC/DC conversion system (TPCS) composed of two or three two-port DC/DC converters are presented. And the five structures are comparatively analyzed. Secondly, based on these topological structures, and combing with the basic two-port DC/DC converters, three groups of typical TPCs with different galvanic isolation requirements are derived respectively by sharing switches, combining branches, etc. And comprehensive analysis, comparisons, and reviews of these TPCs with different structures of each isolation type are presented with tables and figures. Finally, the comparison results of the three isolation groups are summarized, which leads to a guidance for the selection of TPCs in different applications, and then some suggestions for the future research on TPCs are given.