Mark A. Sanders
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mark A. Sanders has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Guillermo Marqués
University Imaging Centers, University of Minnesota, Minneapolis, USA
4 shared publications - Lisa A. Cameron
Light Microscopy Core Facility, Duke University 13 , Durham, NC
3 shared publications - Michelle S. Itano
Neuroscience Microscopy Core Facility, Carolina Institute for Developmental Disabilities & Neuroscience Center, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
3 shared publications - Paula Montero Llopis
Department of Microbiology, Blavatnik Institute, Harvard Medical School, Boston, MA, USA
3 shared publications - Thomas Pengo
Minnesota Supercomputing Institute
3 shared publications Alex Rigano
Program in Molecular Medicine, University of Massachusetts Chan Medical School, Worcester, USA
2 shared publications
Latest Publications
- Open Access
HIV-producing resting T cells monopolize virus production, associated PANoptosis, and persistence in lymphoid tissue
Activated CD4+ T cells have long been considered the principal source of HIV production before treatment and reactivated latently infected cells the source of virus rebound on treatment interruption, based largely on studies of peripheral blood T cells. Here we show before ART in the lymphoid tissue reservoir that HIV-producing resting CD4+ T cells are essentially the sole source of virus production in germinal centers. Virus is produced in infection complexes of virus bearing follicular dendritic cells (FDCs) that induce high multiplicity multi-HIV-DNA copy infections in overlying resting T cells. HIV production is associated with destruction by PANoptosis (pyroptosis, necroptosis and apoptosis) of interacting antibody-producing populations of FDCs, T cells and B cells. PANoptosis is mediated by the PANoptosome, visualized and defined here as a cellular structure incorporating cytoplasmic and nuclear contents and programmed cell death pathway components in a nodal latticework that executes cell emptying and disruption. During ART, HIV-producing resting T cells persist in lymphoid tissues when virus is undetectable in peripheral blood. These HIV-producing resting T cells that persist during ART represent an immediate source of virus to reignite infection on treatment interruption and are thus identified as an important new target for functional cure strategies.
Open AccessHIV-producing resting T cells monopolize virus production, associated PANoptosis, and persistence in lymphoid tissue
Activated CD4+ T cells have long been considered the principal source of HIV production before treatment and reactivated latently infected cells the source of virus rebound on treatment interruption, based largely on studies of peripheral blood T cells. Here we show before ART in the lymphoid tissue reservoir that HIV-producing resting CD4+ T cells are essentially the sole source of virus production in germinal centers. Virus is produced in infection complexes of virus bearing follicular dendritic cells (FDCs) that induce high multiplicity multi-HIV-DNA copy infections in overlying resting T cells. HIV production is associated with destruction by PANoptosis (pyroptosis, necroptosis and apoptosis) of interacting antibody-producing populations of FDCs, T cells and B cells. PANoptosis is mediated by the PANoptosome, visualized and defined here as a cellular structure incorporating cytoplasmic and nuclear contents and programmed cell death pathway components in a nodal latticework that executes cell emptying and disruption. During ART, HIV-producing resting T cells persist in lymphoid tissues when virus is undetectable in peripheral blood. These HIV-producing resting T cells that persist during ART represent an immediate source of virus to reignite infection on treatment interruption and are thus identified as an important new target for functional cure strategies.
- Open Access
- 18 March 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (17) , 7249-7263
Vacuum infiltration for priming of soybean seeds: optimization and particle tracking using fluorescent silica nanoparticles
Vacuum infiltration of nanoparticles into soybean seeds can promote crop health and yields while reducing environmental impact.
- 18 March 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (17) , 7249-7263
Open AccessVacuum infiltration for priming of soybean seeds: optimization and particle tracking using fluorescent silica nanoparticles
Vacuum infiltration of nanoparticles into soybean seeds can promote crop health and yields while reducing environmental impact.
- Open Access
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 2094-2095
Considerations for Tissue Clearing Services in a Shared Research Facility
Biological specimens are intrinsically three-dimensional, molecularly complex structures that scatter light, making imaging deep into most every intact tissue volume problematic. Efforts to minimize light scattering by “clearing” the tissue have been ongoing for more than a century, and recent innovations at multiple stages of the process have occurred. Historically, investigators have relied on histological techniques such as embedding, sectioning, and staining to eliminate the need to image through opaque tissues. Immunohistochemistry of sectioned 3D tissue architecture presented as 2D images has been the foundation of biological studies for decades. By taking advantage of tissue clearing advances, one could consider exploiting these tools to provide complex 3D data on a diverse array of biological tissues. Optimizing a service level application could scale and advance discoveries allowed by these methods. Since 2018 the University Imaging Centers at the University of Minnesota has offered such a tissue clearing service pipeline and we would like to share lessons learned. The pipeline (Fig. 1) consists of tissue fixation, delipidation, refractive index matching, imaging, image processing, image visualization, data storage and distribution. This complex pipeline generates terabyte-scale datasets that may bring novel challenges to the unprepared.
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 2094-2095
Open AccessConsiderations for Tissue Clearing Services in a Shared Research Facility
Biological specimens are intrinsically three-dimensional, molecularly complex structures that scatter light, making imaging deep into most every intact tissue volume problematic. Efforts to minimize light scattering by “clearing” the tissue have been ongoing for more than a century, and recent innovations at multiple stages of the process have occurred. Historically, investigators have relied on histological techniques such as embedding, sectioning, and staining to eliminate the need to image through opaque tissues. Immunohistochemistry of sectioned 3D tissue architecture presented as 2D images has been the foundation of biological studies for decades. By taking advantage of tissue clearing advances, one could consider exploiting these tools to provide complex 3D data on a diverse array of biological tissues. Optimizing a service level application could scale and advance discoveries allowed by these methods. Since 2018 the University Imaging Centers at the University of Minnesota has offered such a tissue clearing service pipeline and we would like to share lessons learned. The pipeline (Fig. 1) consists of tissue fixation, delipidation, refractive index matching, imaging, image processing, image visualization, data storage and distribution. This complex pipeline generates terabyte-scale datasets that may bring novel challenges to the unprepared.
- Open Access
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 995-996
An Optimized Optical Clearing Pipeline for Intact 3D Plant Imaging and Visualization of Fluorescent Probes
Here we report an adapted version of the ClearSee1 tissue clearing technique optimized for plant tissues, which enables whole plant imaging to visualize stains and expressed fluorescent proteins. This approach facilitates protein and vascular system localization in intact tissue in 3D, while retaining cellular-level structure, permitting the exploration of plant connectome interactions.
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 995-996
Open AccessAn Optimized Optical Clearing Pipeline for Intact 3D Plant Imaging and Visualization of Fluorescent Probes
Here we report an adapted version of the ClearSee1 tissue clearing technique optimized for plant tissues, which enables whole plant imaging to visualize stains and expressed fluorescent proteins. This approach facilitates protein and vascular system localization in intact tissue in 3D, while retaining cellular-level structure, permitting the exploration of plant connectome interactions.
- Open Access
Detecting sources of immune activation and viral rebound in HIV infection
Antiretroviral therapy (ART) generally suppresses HIV replication to undetectable levels in peripheral blood, but immune activation associated with increased morbidity and mortality is sustained during ART, and infection rebounds when treatment is interrupted. To identify drivers of immune activation and potential sources of viral rebound, we modified RNAscope in situ hybridization to visualize HIV-virus producing cells as a standard to compare the following assays of potential sources of immune activation and virus rebound following treatment interruption: 1) EDITS (envelope detection by induced transcription-based sequencing) assay; 2) HIV-Flow; and 3) Flow-FISH assays that can scan tissues and cell suspensions to detect rare cells expressing env mRNA, gag mRNA/Gag protein and p24 respectively; and 4) an ultrasensitive immunoassay that detects p24 in cell/tissue lysates at subfemtomolar levels. We show that the sensitivity of these assays is sufficient to detect a rare HIV-producing/env mRNA+/p24+ cell in a million uninfected cells. These high-throughput technologies thus provide contemporary tools to detect and characterize rare cells producing virus and viral antigens as potential sources of immune activation and viral rebound. Importance: Anti-retroviral therapy (ART) has greatly improved the quality and length of life for people living with HIV, but immune activation does not normalize during ART, and persistent immune activation has been linked to increased morbidity and mortality. We report a comparison of assays of two potential sources of immune activation during ART: rare cells producing HIV virus or the virus’ major viral protein, p24, benchmarked on a cell model of active and latent infections and a method to visualize HIV-producing cells. We show that assays of HIV Envelope mRNA (EDITS assay) and gag mRNA and p24 (Flow-FISH, HIV-Flow and ultrasensitive p24 immunoassay) detect HIV-producing cells and p24 at sensitivities of one infected cell in a million uninfected cells, thus providing validated tools to explore sources of immune activation during ART in the lymphoid and other tissue reservoirs.
Open AccessDetecting sources of immune activation and viral rebound in HIV infection
Antiretroviral therapy (ART) generally suppresses HIV replication to undetectable levels in peripheral blood, but immune activation associated with increased morbidity and mortality is sustained during ART, and infection rebounds when treatment is interrupted. To identify drivers of immune activation and potential sources of viral rebound, we modified RNAscope in situ hybridization to visualize HIV-virus producing cells as a standard to compare the following assays of potential sources of immune activation and virus rebound following treatment interruption: 1) EDITS (envelope detection by induced transcription-based sequencing) assay; 2) HIV-Flow; and 3) Flow-FISH assays that can scan tissues and cell suspensions to detect rare cells expressing env mRNA, gag mRNA/Gag protein and p24 respectively; and 4) an ultrasensitive immunoassay that detects p24 in cell/tissue lysates at subfemtomolar levels. We show that the sensitivity of these assays is sufficient to detect a rare HIV-producing/env mRNA+/p24+ cell in a million uninfected cells. These high-throughput technologies thus provide contemporary tools to detect and characterize rare cells producing virus and viral antigens as potential sources of immune activation and viral rebound. Importance: Anti-retroviral therapy (ART) has greatly improved the quality and length of life for people living with HIV, but immune activation does not normalize during ART, and persistent immune activation has been linked to increased morbidity and mortality. We report a comparison of assays of two potential sources of immune activation during ART: rare cells producing HIV virus or the virus’ major viral protein, p24, benchmarked on a cell model of active and latent infections and a method to visualize HIV-producing cells. We show that assays of HIV Envelope mRNA (EDITS assay) and gag mRNA and p24 (Flow-FISH, HIV-Flow and ultrasensitive p24 immunoassay) detect HIV-producing cells and p24 at sensitivities of one infected cell in a million uninfected cells, thus providing validated tools to explore sources of immune activation during ART in the lymphoid and other tissue reservoirs.
- 15 October 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (12) , 1414-1416
MethodsJ2: a software tool to capture metadata and generate comprehensive microscopy methods text
- 15 October 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (12) , 1414-1416
MethodsJ2: a software tool to capture metadata and generate comprehensive microscopy methods text
- Open Access
MethodsJ2: A Software Tool to Improve Microscopy Methods Reporting
Proper reporting of metadata is essential to reproduce microscopy experiments, interpret results and share images. Experimental scientists can report details about sample preparation and imaging conditions while imaging scientists have the expertise required to collect and report the image acquisition, hardware and software metadata information. MethodsJ2 is an ImageJ/Fiji based software tool that gathers metadata and automatically generates text for the methods section of publications.
Open AccessMethodsJ2: A Software Tool to Improve Microscopy Methods Reporting
Proper reporting of metadata is essential to reproduce microscopy experiments, interpret results and share images. Experimental scientists can report details about sample preparation and imaging conditions while imaging scientists have the expertise required to collect and report the image acquisition, hardware and software metadata information. MethodsJ2 is an ImageJ/Fiji based software tool that gathers metadata and automatically generates text for the methods section of publications.
- 7 June 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (12) , 1463-1476
Best practices and tools for reporting reproducible fluorescence microscopy methods
Although fluorescence microscopy is ubiquitous in biomedical research, microscopy methods reporting is inconsistent and perhaps undervalued. We emphasize the importance of appropriate microscopy methods reporting and seek to educate researchers about how microscopy metadata impact data interpretation. We provide comprehensive guidelines and resources to enable accurate reporting for the most common fluorescence light microscopy modalities. We aim to improve microscopy reporting, thus improving the quality, rigor and reproducibility of image-based science.
- 7 June 2021
- Published by Springer Nature in Nature Methods
- Vol. 18 (12) , 1463-1476
Best practices and tools for reporting reproducible fluorescence microscopy methods
Although fluorescence microscopy is ubiquitous in biomedical research, microscopy methods reporting is inconsistent and perhaps undervalued. We emphasize the importance of appropriate microscopy methods reporting and seek to educate researchers about how microscopy metadata impact data interpretation. We provide comprehensive guidelines and resources to enable accurate reporting for the most common fluorescence light microscopy modalities. We aim to improve microscopy reporting, thus improving the quality, rigor and reproducibility of image-based science.
- Open Access
- 23 November 2020
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 117 (49) , 31301-31308
Decreased mechanotransduction prevents nuclear collapse in a Caenorhabditis elegans laminopathy
Significance: Nuclear envelopathies are a complex group of human diseases caused by mutations in nuclear envelope proteins, including progeria, myopathy, and dystonia. Here, we used the Caenorhabditis elegans germline as a model system to investigate the function of the OOC-5/torsinA AAA+ ATPase, which localizes to the nuclear envelope and is mutated in early-onset DYT1 dystonia in humans. We show that OOC-5/torsinA promotes the function of the LINC complex, which spans the nuclear envelope and transmits forces to the nuclear lamina. Remarkably, decreasing the function of OOC-5/torsinA or the LINC complex prevents nuclear collapse in the absence of a functional nuclear lamina. Therapeutics targeting torsinA or the LINC complex might prevent nuclear damage from endogenous forces in certain nuclear envelopathies.
- 23 November 2020
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 117 (49) , 31301-31308
Open AccessDecreased mechanotransduction prevents nuclear collapse in a Caenorhabditis elegans laminopathy
Significance: Nuclear envelopathies are a complex group of human diseases caused by mutations in nuclear envelope proteins, including progeria, myopathy, and dystonia. Here, we used the Caenorhabditis elegans germline as a model system to investigate the function of the OOC-5/torsinA AAA+ ATPase, which localizes to the nuclear envelope and is mutated in early-onset DYT1 dystonia in humans. We show that OOC-5/torsinA promotes the function of the LINC complex, which spans the nuclear envelope and transmits forces to the nuclear lamina. Remarkably, decreasing the function of OOC-5/torsinA or the LINC complex prevents nuclear collapse in the absence of a functional nuclear lamina. Therapeutics targeting torsinA or the LINC complex might prevent nuclear damage from endogenous forces in certain nuclear envelopathies.
- Open Access
- 11 August 2020
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 9
Imaging methods are vastly underreported in biomedical research
A variety of microscopy techniques are used by researchers in the life and biomedical sciences. As these techniques become more powerful and more complex, it is vital that scientific articles containing images obtained with advanced microscopes include full details about how each image was obtained. To explore the reporting of such details we examined 240 original research articles published in eight journals. We found that the quality of reporting was poor, with some articles containing no information about how images were obtained, and many articles lacking important basic details. Efforts by researchers, funding agencies, journals, equipment manufacturers and staff at shared imaging facilities are required to improve the reporting of experiments that rely on microscopy techniques.
- 11 August 2020
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 9
Open AccessImaging methods are vastly underreported in biomedical research
A variety of microscopy techniques are used by researchers in the life and biomedical sciences. As these techniques become more powerful and more complex, it is vital that scientific articles containing images obtained with advanced microscopes include full details about how each image was obtained. To explore the reporting of such details we examined 240 original research articles published in eight journals. We found that the quality of reporting was poor, with some articles containing no information about how images were obtained, and many articles lacking important basic details. Efforts by researchers, funding agencies, journals, equipment manufacturers and staff at shared imaging facilities are required to improve the reporting of experiments that rely on microscopy techniques.