OSOmar Siddiqi

Omar Siddiqi

*This is an algorithmically generated author record based on publicly available information.

Omar Siddiqi has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Propofol sedation does not improve measures of colonoscopy quality but increase cost – findings from a large population-based cohort study

    by Sheikh Rahman, Lauren E. Cipriano, Cassandra McDonald, Sarah Cocco, Ziad Hindi, Debarati Chakraborty, Karissa French, Omar Siddiqi, Mayur Brahmania, Aze Wilson, et al.


  • Open Access

    A113 ANNUAL COLONOSCOPY VOLUME IS NOT PREDICTIVE OF COLONOSCOPY QUALITY - FINDINGS FROM THE SOUTHWEST ONTARIO COLONOSCOPY COHORT

    by M Sey, O Siddiqi, C McDonald, S Cocco, Z Hindi, H Rahman, D Chakraborti, K French, M Alsager, M Blier, et al.

    Performing a minimum number of colonoscopies annually has been proposed by some jurisdictions as a requirement for maintaining privileges. However, this practice is supported by limited evidence. The objective of this study was to determine if annual colonoscopy volume was associated with colonoscopy quality metrics. A population-based study was performed using the Southwest Ontario Colonoscopy cohort, which consists of all adult patients who underwent colonoscopy between April 2017 and Oct 2018 at 21 academic and community hospitals within the health region. Data were collected through a mandatory quality assurance form completed after each procedure and pathology reports were manually reviewed. Physician annualized colonoscopy volumes were compared by correlation analysis to each quality-related outcome, by means of the area under the receiver operating characteristics curve (AUROC), and logistic regression. The prognostic value of colonoscopy volume was also adjusted for case-mix and potential confounders in separate regression analyses for each outcome. The primary outcome was ADR. Secondary outcomes were polyp detection rate (PDR), sessile serrated polyp detection rate (SSPDR), and cecal intubation. A total of 47,195 colonoscopies were performed by 75 physicians (37.5% by gastroenterologists, 60% by general surgeons, 2.5% others). There were no clear relationships between annual colonoscopy volumes and study outcomes. Colonoscopy volume was not associated with ADR (OR 1.03, 95% CI 0.96–1.10, p=0.48) and corresponded to an AUROC not significantly different from the null (AUROC 0.52, 95% CI 0.43–0.61, p=0.65). Multi-variable regression adjusting for case-mix also demonstrated no predictive value of annual colonoscopy volume for the primary outcome (OR 1.03, 95% CI 0.94–1.12, p=0.55). Similarly, analyses of secondary outcomes failed to find an association between colonoscopy volume and PDR, SSPDR, or cecal intubation (Table 1). Annual colonoscopy volumes do not predict ADR, PDR, SSPDR, or cecal intubation rate. Results of unconditional and conditional approaches for examining the predictive value of annual colonoscopy volume for quality related outcomes. None

  • A systematic review of metal ion concentrations following instrumented spinal fusion

    by Omar Siddiqi, Jennifer C. Urquhart, Parham Rasoulinejad

    Purpose Metallic spinal implants undergo wear and corrosion which liberates ionic or particulate metal debris. The purpose of this study was to identify and review studies that report the concentration of metal ions following multi-level spinal fusion and to evaluate the impact on clinical outcomes. Methods Databases (PubMed, EBSCO MEDLINE) were searched up to August 2019 for studies in English-language assessing metal ion levels [chromium (Cr), titanium (Ti), nickel (Ni)] in whole blood, serum, or plasma after spinal fusion using a specific search string. Study, patient, and implant characteristics, method of analysis, metal ion concentration, as well as clinical and radiographic results was extracted. Results The systematic search yielded 18 studies encompassing 653 patients. 9 studies reported Ti ions, eight reported Cr, and six reported Ni. Ti levels were elevated compared to controls/reference range/preoperative baseline in seven studies with the other two reporting no difference. Cr levels were elevated compared to controls/reference range in seven studies with one reporting no difference. Ni levels showed no difference from controls/reference range in four studies with one reporting above normal and another elevated compared to controls. Radiographic evidence of corrosion, implant failure, pseudarthrosis, revision surgery and adverse reaction reporting was highly variable. Conclusion Metal ions are elevated after instrumented spinal fusion; notably Cr levels from stainless steel implants and Ti from titanium implants. The association between clinical and radiographic outcomes remain uncertain but is concerning. Further research with standardized reporting over longer follow-up periods is indicated to evaluate the clinical impact and minimizing risk.


  • Sa1051 WHAT IS THE IMPACT OF TRAINEE PARTICIPATION ON COLONOSCOPY QUALITY - FINDINGS FROM THE SOUTHWEST ONTARIO COLONOSCOPY COHORT

    by Michael Sey, Sarah Cocco, Cassandra McDonald, Zaid Hindi, Hasibur S. Rahman, Debarati Chakraborty, Karissa French, Mohammad Alsager, Omar Siddiqi, Marc-André Blier, et al.

  • Open Access

    A276 CLINCAL PREDICTORS FOR SESSILE SERRATED ADENOMA DETECTION: AN ANALYSIS OF 17,524 COLONOSCOPIES

    by M Gandhi, S Cocco, C McDonald, Z Hindi, D Chakraborty, K French, O Siddiqi, M Blier, B Markandey, V Siebring, et al.

    Adenoma detection and removal is crucial to prevent colon cancer. Although adenoma detection rate is the current benchmark, there is increasing interest in sessile serrated adenoma detection rate (SSADR) given sessile serrated adenomas (SSAs) are more difficult to identify endoscopically. To define predictors of SSA detection in a large colonoscopy cohort. We performed a prospective observational study using colonoscopy quality metrics collected by Cancer Care Ontario. All colonoscopies performed for any indication across 20 hospitals in Southwestern Ontario between April 2017 and February 2018 were identified. Data collected included patient demographics, procedural indication, bowel preparation, cecal intubation, endoscopist information, and histology of polyps removed. Cases without histology records were excluded. A multi-variable analysis was conducted to identify factors associated with SSA detection. In total, 17,524 colonoscopies (mean (SD) age = 59.6 (14.4), 53.9% female) were identified. At least one SSA was identified in 910 procedures, corresponding to a SSADR of 5.2%. On multi-variable analysis, variables independently associated with higher SSADR included increasing patient age (OR 1.02, 95% CI 1.02–1.03, p<0.001), cecal intubation (OR 3.80, 95% CI 1.87–7.71, p<0.001), use of split dose bowel preparation (OR 1.33, 95% CI 1.00–1.77, p=0.047), and very good bowel preparation quality (OR 2.48, 95% CI 1.38–4.44, p=0.002). Factors associated with lower SSADRs included non-screening colonoscopies (OR 0.55, 95% CI 0.48–0.63, p<0.001) and non-gastroenterologist endoscopist (general surgery OR 0.50, 95% CI 0.41–0.60, p<0.001; internal medicine OR 0.70, 95% CI 0.51–0.96, p=0.027; general practice OR 0.20, 95% CI 0.06–0.68, p=0.010). Modifiable factors associated with higher SSADRs include use of split dose bowel preparation, better bowel preparation quality, cecal intubation, and specialty of endoscopist. Ongoing initiatives emphasizing the importance of these variables should be encouraged. Clinical Predictors for SSA Detection Clinical Predictors for SSA Detection None