Pallab Roy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pallab Roy has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Anindya Sarkar
Department of Geology and Geophysics Indian Institute of Technology Kharagpur India
2 shared publications - Sangbaran Ghoshmaulik
Department of Geology and Geophysics Indian Institute of Technology Kharagpur India
2 shared publications - Sourendra Kumar Bhattacharya
Institute of Earth Sciences Academia Sinica Taipei Taiwan
2 shared publications Alauddin Bhuiyan
Department of Ophthalmology, Icahn School of Medicine at Mount Sinai
1 shared publicationD. Panigrahi
Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
1 shared publication- Deepak Bhasin
2,4,5Department of Pulmonology and Critical Care, Max Super Speciality Hospital, Mohali, Punjab, India
1 shared publication
Latest Publications
- Open Access
A Novel Retinal Vascular Feature and Machine Learning-based Brain White Matter Lesion Prediction Model
White matter lesion (WML) is one of the common cerebral abnormalities, it indicates changes in the white matter of human brain and have shown significant association with stroke, dementia and deaths. Magnetic resonance imaging (MRI) of the brain is frequently used to diagnose white matter lesion (WML) volume. Regular screening can detect WML in early stage and save from severe consequences. Current option of MRI based diagnosis is impractical for regular screening because of its high expense and unavailability. Thus, earlier screening and prediction of the WML volume/load specially in the rural and remote areas becomes extremely difficult. Research has shown that changes in the retinal micro vascular system reflect changes in the cerebral micro vascular system. Using this information, we have proposed a retinal image based WML volume and severity prediction model which is very convenient and easy to operate. Our proposed model can help the physicians to detect the patients who need immediate and further MRI based detail diagnosis of WML. Our model uses quantified measurement of retinal micro-vascular signs (such as arteriovenular nicking (AVN), Opacity (OP) and focal arteriolar narrowing (FAN)) as input and estimate the WML volume/load and classify its severity. We evaluate our proposed model on a dataset of 111 patients taken from the ENVISion study which have retinal and MRI images for each patient. Our model shows high accuracy in estimating the WML volume, mean square error (MSE) between our predicted WML load and manually annotated WML load is 0.15. The proposed model achieves an F1 score of 0.92 in classifying the patients having mild and severe WML load. The preliminary results of our study indicate that quantified measurement of retinal micro-vascular features (AVN, OP and FAN) can more accurately identify the patients who have high risk of cardio-vascular diseases and dementia.
Open AccessA Novel Retinal Vascular Feature and Machine Learning-based Brain White Matter Lesion Prediction Model
White matter lesion (WML) is one of the common cerebral abnormalities, it indicates changes in the white matter of human brain and have shown significant association with stroke, dementia and deaths. Magnetic resonance imaging (MRI) of the brain is frequently used to diagnose white matter lesion (WML) volume. Regular screening can detect WML in early stage and save from severe consequences. Current option of MRI based diagnosis is impractical for regular screening because of its high expense and unavailability. Thus, earlier screening and prediction of the WML volume/load specially in the rural and remote areas becomes extremely difficult. Research has shown that changes in the retinal micro vascular system reflect changes in the cerebral micro vascular system. Using this information, we have proposed a retinal image based WML volume and severity prediction model which is very convenient and easy to operate. Our proposed model can help the physicians to detect the patients who need immediate and further MRI based detail diagnosis of WML. Our model uses quantified measurement of retinal micro-vascular signs (such as arteriovenular nicking (AVN), Opacity (OP) and focal arteriolar narrowing (FAN)) as input and estimate the WML volume/load and classify its severity. We evaluate our proposed model on a dataset of 111 patients taken from the ENVISion study which have retinal and MRI images for each patient. Our model shows high accuracy in estimating the WML volume, mean square error (MSE) between our predicted WML load and manually annotated WML load is 0.15. The proposed model achieves an F1 score of 0.92 in classifying the patients having mild and severe WML load. The preliminary results of our study indicate that quantified measurement of retinal micro-vascular features (AVN, OP and FAN) can more accurately identify the patients who have high risk of cardio-vascular diseases and dementia.
- 19 May 2020
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 34 (18) , e8833
A simple cryogenic method for efficient analysis of triple oxygen isotopes in silicates
Rationale: Oxygen isotopic ratios of silicates are excellent tools to reconstruct paleotemperature and isotopic composition of the precipitating fluid. However, the measurement of 17 O/ 16 O is difficult due to the low abundance of 17 O. The present study reports a simplified high‐precision analytical technique for measuring the two oxygen isotope ratios, 17 O/ 16 O and 18 O/ 16 O, in silicates. Methods: Silicate samples were ablated by a CO 2 laser in a BrF 5 environment. The released oxygen (O 2 ) was then cryogenically trapped in a molecular sieve zeolite (MSZ). Associated contaminants such as BrF 5 , F 2 , NF 3 etc. were cleaned by passing the gas through a NaCl trap followed by a cooled (−25°C) MSZ‐packed U‐tube trap. The purified O 2 was analysed in a MAT 253 isotope ratio mass spectrometer for oxygen isotope ratios. Results: The δδ 17 O and δ 18 O values of the working gas were calibrated by NBS‐28 and crosschecked by inter‐laboratory references UWG‐2, SCO and IMAU‐O 2 . The average analytical precisions (using aliquots of NBS‐28, UWG‐2, SCO, and laboratory internal standards IIT‐KGP‐SQ quartz and IIT‐KGP‐NQ quartz) of the δ 17 O, δ 18 O and ∆′ 17 O values were 0.04‰, 0.08‰ and 4 per meg, respectively. Conclusions: A new cryogenic cleaning technique was developed that does not require GC but efficiently removes NF 3 ‐contaminants from oxygen gas produced by laser fluorination of silicates. The technique is simple, quick and cost‐effective and provides highly precise and accurate δ 17 O, δ 18 O and ∆′ 17 O values.
- 19 May 2020
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 34 (18) , e8833
A simple cryogenic method for efficient analysis of triple oxygen isotopes in silicates
Rationale: Oxygen isotopic ratios of silicates are excellent tools to reconstruct paleotemperature and isotopic composition of the precipitating fluid. However, the measurement of 17 O/ 16 O is difficult due to the low abundance of 17 O. The present study reports a simplified high‐precision analytical technique for measuring the two oxygen isotope ratios, 17 O/ 16 O and 18 O/ 16 O, in silicates. Methods: Silicate samples were ablated by a CO 2 laser in a BrF 5 environment. The released oxygen (O 2 ) was then cryogenically trapped in a molecular sieve zeolite (MSZ). Associated contaminants such as BrF 5 , F 2 , NF 3 etc. were cleaned by passing the gas through a NaCl trap followed by a cooled (−25°C) MSZ‐packed U‐tube trap. The purified O 2 was analysed in a MAT 253 isotope ratio mass spectrometer for oxygen isotope ratios. Results: The δδ 17 O and δ 18 O values of the working gas were calibrated by NBS‐28 and crosschecked by inter‐laboratory references UWG‐2, SCO and IMAU‐O 2 . The average analytical precisions (using aliquots of NBS‐28, UWG‐2, SCO, and laboratory internal standards IIT‐KGP‐SQ quartz and IIT‐KGP‐NQ quartz) of the δ 17 O, δ 18 O and ∆′ 17 O values were 0.04‰, 0.08‰ and 4 per meg, respectively. Conclusions: A new cryogenic cleaning technique was developed that does not require GC but efficiently removes NF 3 ‐contaminants from oxygen gas produced by laser fluorination of silicates. The technique is simple, quick and cost‐effective and provides highly precise and accurate δ 17 O, δ 18 O and ∆′ 17 O values.
- 1 January 1995
- Published by Wiley in American Journal of Hematology
- Vol. 48 (1) , 52-54
Hyperaggregation of platelets in intestinal tuberculosis: Role of platelets in chronic inflammation
Eighty‐eight percent (38/43) patients of intestinal tuberculosis showed significant hyperaggregation of platelets (P < 0.001). Serum and plasma from 15 patients when incubated with normal platelets caused hyperaggregation. Gel filtered platelets from 2 patients suspended in normal plasma showed hyperaggregation of platelets with arachidonic acid. Tubercular protein had no effect on platelet aggregation. A role of hyperactive platelets in chronic inflammatory response is discussed. ©1995 Wiley‐Liss, Inc.
- 1 January 1995
- Published by Wiley in American Journal of Hematology
- Vol. 48 (1) , 52-54
Hyperaggregation of platelets in intestinal tuberculosis: Role of platelets in chronic inflammation
Eighty‐eight percent (38/43) patients of intestinal tuberculosis showed significant hyperaggregation of platelets (P < 0.001). Serum and plasma from 15 patients when incubated with normal platelets caused hyperaggregation. Gel filtered platelets from 2 patients suspended in normal plasma showed hyperaggregation of platelets with arachidonic acid. Tubercular protein had no effect on platelet aggregation. A role of hyperactive platelets in chronic inflammatory response is discussed. ©1995 Wiley‐Liss, Inc.