Jens Høvik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jens Høvik has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Astrid Aksnes
Norwegian Univ Sci & Technol, Dept Elect Syst, Trondheim, Norway
3 shared publications- Astrid Aksnes
Department of Electronic Systems, Norwegian University of Science, Technology, Trondheim, Norway
2 shared publications Andrei Avram
National Institute for RD in Microtechnologies - IMT Bucharest,Voluntari,Romania
1 shared publicationCharles De Boer
Kavli Institute of Nanoscience,Delft,Netherlands
1 shared publicationDag Roar Hjelme
Norwegian Univ. of Science and Technology (Norway)
1 shared publication- Daniel Vala
Faculty of Materials Science and Technology VSB – Technical University of Ostrava 17. listopadu 15 708 00 Ostrava Czech Republic
1 shared publication
Latest Publications
- Open Access
- 25 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 18 (3) , 1-9
Dual Phase Match Turning Point Sensor for Ultra-High Sensitivity Over Large Wavelength Ranges
The sensing capabilities of long-period grating assisted coupling between waveguides on the silicon-on-insulator platform are examined both through dispersion- and guided-wave simulations. A novel two phase-match turning point design is identified through dispersion optimization. Utilizing this design, the sensitivity of a long period grating coupler sensor can remain up to 40 $\mu \rm {m}$ / RIU over a wavelength span of 500 nm with a near constant sensitivity over a wavelength span of 300 nm. This design solves some of the more common issues with dispersion engineered refractive index sensors such as sensitivity instability and low fabrication tolerance, while enabling higher sensitivity devices for e.g. biosensing. This simple design is CMOS-compatible and potentially mass producible using standard fabrication lines. The performance of such high-sensitivity devices often varies with small perturbations of sensor geometry, motivating the study of the fabrication tolerance of the device. Assuming the fabrication variance of a standard deep-UV photonics process line, the aformentioned device performance is maintained through careful choice of device geometry.
- 25 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 18 (3) , 1-9
Open AccessDual Phase Match Turning Point Sensor for Ultra-High Sensitivity Over Large Wavelength Ranges
The sensing capabilities of long-period grating assisted coupling between waveguides on the silicon-on-insulator platform are examined both through dispersion- and guided-wave simulations. A novel two phase-match turning point design is identified through dispersion optimization. Utilizing this design, the sensitivity of a long period grating coupler sensor can remain up to 40 $\mu \rm {m}$ / RIU over a wavelength span of 500 nm with a near constant sensitivity over a wavelength span of 300 nm. This design solves some of the more common issues with dispersion engineered refractive index sensors such as sensitivity instability and low fabrication tolerance, while enabling higher sensitivity devices for e.g. biosensing. This simple design is CMOS-compatible and potentially mass producible using standard fabrication lines. The performance of such high-sensitivity devices often varies with small perturbations of sensor geometry, motivating the study of the fabrication tolerance of the device. Assuming the fabrication variance of a standard deep-UV photonics process line, the aformentioned device performance is maintained through careful choice of device geometry.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Method for Comparing Dry Etch Equipment
In this paper, we present a verification method to compare the hardware and etch performance of different Oxford Instruments dry etching systems to facilitate etch recipe transfer. The flow-pressure window and the chemical and physical flux within the same flow-pressure window were determined for each system. The chemical and physical fluxes were matched between the investigated systems to yield similar etch results. The method was tested using a continuous SF 6 /O2 silicon etching recipe.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Method for Comparing Dry Etch Equipment
In this paper, we present a verification method to compare the hardware and etch performance of different Oxford Instruments dry etching systems to facilitate etch recipe transfer. The flow-pressure window and the chemical and physical flux within the same flow-pressure window were determined for each system. The chemical and physical fluxes were matched between the investigated systems to yield similar etch results. The method was tested using a continuous SF 6 /O2 silicon etching recipe.
- Open Access
- 21 December 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (1) , 703-721
Diffractive order Mueller matrix ellipsometry for the design and manufacture of polarization beam splitting metasurfaces
Optical metasurface technology promises an important potential for replacing bulky traditional optical components, in addition to enabling new compact and lightweight metasurface-based devices. Since even subtle imperfections in metasurface design or manufacture strongly affect their performance, there is an urgent need to develop proper and accurate protocols for their characterization, allowing for efficient control of the fabrication. We present non-destructive spectroscopic Mueller matrix ellipsometry in an uncommon off-specular configuration as a powerful tool for the characterization of orthogonal polarization beam-splitters based on a-Si:H nanopillars. Through Mueller matrix analysis, the spectroscopic polarimetric performance of the ±1 diffraction orders is experimentally demonstrated. This reveals a wavelength shift in the maximum efficiency caused by fabrication-induced conical pillars while still maintaining a polarimetric response close to ideal non-depolarizing Mueller matrices. We highlight the advantage of the spectroscopic Mueller matrix approach, which not only allows for monitoring and control of the fabrication process itself, but also verifies the initial design and produces feedback into the computational design.
- 21 December 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (1) , 703-721
Open AccessDiffractive order Mueller matrix ellipsometry for the design and manufacture of polarization beam splitting metasurfaces
Optical metasurface technology promises an important potential for replacing bulky traditional optical components, in addition to enabling new compact and lightweight metasurface-based devices. Since even subtle imperfections in metasurface design or manufacture strongly affect their performance, there is an urgent need to develop proper and accurate protocols for their characterization, allowing for efficient control of the fabrication. We present non-destructive spectroscopic Mueller matrix ellipsometry in an uncommon off-specular configuration as a powerful tool for the characterization of orthogonal polarization beam-splitters based on a-Si:H nanopillars. Through Mueller matrix analysis, the spectroscopic polarimetric performance of the ±1 diffraction orders is experimentally demonstrated. This reveals a wavelength shift in the maximum efficiency caused by fabrication-induced conical pillars while still maintaining a polarimetric response close to ideal non-depolarizing Mueller matrices. We highlight the advantage of the spectroscopic Mueller matrix approach, which not only allows for monitoring and control of the fabrication process itself, but also verifies the initial design and produces feedback into the computational design.
- Open Access
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (1) , 1-6
Inverse Effective Index Method for Two-Dimensional Simulations of Photonic Components
The representation of three-dimensional integrated photonic structures in two-dimensional designs has been investigated through finite element analysis using COMSOL Multiphysics. The accuracy of the effective index method for various waveguide designs is studied. An alternative to the effective index method, here named the inverse effective index method, is derived in this paper. The results indicate that the commonly used effective index method has a deviation in propagation constant up to 17%, where the error is largest for low-confinement factor waveguides. The inverse effective index method vastly reduces this error to $< $ 0.01% for low confinement-factor geometries. This enables an accurate simulation in two-dimensions while retaining the waveguiding properties of the third dimension. As with the effective index method, the inverse effective index method does not require proprietary software.
- 12 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (1) , 1-6
Open AccessInverse Effective Index Method for Two-Dimensional Simulations of Photonic Components
The representation of three-dimensional integrated photonic structures in two-dimensional designs has been investigated through finite element analysis using COMSOL Multiphysics. The accuracy of the effective index method for various waveguide designs is studied. An alternative to the effective index method, here named the inverse effective index method, is derived in this paper. The results indicate that the commonly used effective index method has a deviation in propagation constant up to 17%, where the error is largest for low-confinement factor waveguides. The inverse effective index method vastly reduces this error to $< $ 0.01% for low confinement-factor geometries. This enables an accurate simulation in two-dimensions while retaining the waveguiding properties of the third dimension. As with the effective index method, the inverse effective index method does not require proprietary software.
- 29 July 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (16) , 23936-23949
Waveguide asymmetric long-period grating couplers as refractive index sensors
A highly sensitive integrated photonic transducer is designed by utilizing asymmetric long-period gratings on a silicon waveguide. These gratings are formed by periodic perturbation of the waveguide width, leading to coupling between the fundamental mode and the 1st order asymmetric leaky mode. The coupled modes are studied via finite-element and finite-difference time-domain methods. Only a single fabrication step is required to realize this novel design. The device is utilized as a refractive index sensor in liquid, yielding a sensitivity of 5078 nm/RIU. The design is a unique combination of being highly sensitive, easily fabricated and highly compact.
- 29 July 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (16) , 23936-23949
Waveguide asymmetric long-period grating couplers as refractive index sensors
A highly sensitive integrated photonic transducer is designed by utilizing asymmetric long-period gratings on a silicon waveguide. These gratings are formed by periodic perturbation of the waveguide width, leading to coupling between the fundamental mode and the 1st order asymmetric leaky mode. The coupled modes are studied via finite-element and finite-difference time-domain methods. Only a single fabrication step is required to realize this novel design. The device is utilized as a refractive index sensor in liquid, yielding a sensitivity of 5078 nm/RIU. The design is a unique combination of being highly sensitive, easily fabricated and highly compact.
- 18 September 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10729, 107290N
Sensitivity enhanced biophotonic sensor utilizing sub-wavelength gratings
We present a sensor design based on a Mach-Zehnder interferometer utilizing sub-wavelength gratings (SWGs) that were included in the waveguide to compensate for the short optical path length and to provide phase modulation. According to 2D finite element method simulations, it is possible to achieve 3-fold enhancement in sensitivity and 50% increase in modulation frequency with the inclusion of SWGs in the sensing arm as well as in the reference arm.
- 18 September 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10729, 107290N
Sensitivity enhanced biophotonic sensor utilizing sub-wavelength gratings
We present a sensor design based on a Mach-Zehnder interferometer utilizing sub-wavelength gratings (SWGs) that were included in the waveguide to compensate for the short optical path length and to provide phase modulation. According to 2D finite element method simulations, it is possible to achieve 3-fold enhancement in sensitivity and 50% increase in modulation frequency with the inclusion of SWGs in the sensing arm as well as in the reference arm.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTu5A.19
Loss reduction of electron-beam lithography fabricated strip wire waveguide bends
Electron-beam lithography causes segmentation in curved components due to the fracturing of the mask pattern file. We investigate this effect and optimize the segmentation to achieve low-loss photonic strip-wire waveguide bends.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTu5A.19
Loss reduction of electron-beam lithography fabricated strip wire waveguide bends
Electron-beam lithography causes segmentation in curved components due to the fracturing of the mask pattern file. We investigate this effect and optimize the segmentation to achieve low-loss photonic strip-wire waveguide bends.